Self-Test of Air-Coupled Probe for Sensitivity Map Production Using Parabolic Reflector
Open Access
- 15 July 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (9) , 1132-1140
Abstract
Spatial distribution of a transduction efficiency over the air-coupled probe surface was proposed as a convenient tool for the probe integrity inspection. In this research, a parabolic reflector is used for passive focusing of the acoustic wave on the surface of inspected probe. Therefore, no additional transducer is required for inspection: probe is used for self-inspection. This approach allows to avoid the expensive focused transducer and replaces it by same type air coupled transducers as probe under test. Moreover, use of the parabolic mirror for focusing is frequency-independent, therefore such approach allows to inspect a wide range of the probes. Spread spectrum signals were used for excitation to improve the SNR and bandwidth coverage. Results of the experimental measurements of air-coupled transducer sensitivity map with natural and artificial defects implemented have been presented. Comparison with previously proposed techniques is given. It was found that defects presence distorts the focused beam, creating large sidelobes. Therefore sensitivity map obtained with proposed technique is lower quality than with previously proposed techniques. Beam profile measurements using a miniature microphone have been presented. Aperture-limiting mask has been proposed to reduce the sidelobes arising due to defects presence and resulting measurements quality has been improved.Keywords
Funding Information
- Research Council of Lithuania (S-MIP-23-133)
This publication has 36 references indexed in Scilit:
- Ultrasonic needle hydrophone calibration in air by a parabolic off-axis mirror focused beam using three-transducer reciprocityUltrasonics, 2023
- Acoustic and rheological characterization of hollow glass microsphere composite for development of optimized air-coupled ultrasonic matching layerCeramics International, 2022
- Investigation of an air-coupled transducer with a closed-cell material matching strategy and an optimization design considering the electrical input impedanceUltrasonics, 2021
- High frequency focused imaging for ultrasonic probe integrity inspectionNDT & E International, 2020
- Investigation of a multi-element focused air-coupled transducerAIP Advances, 2018
- Calculation of acoustic field based on laser-measured vibration velocities on ultrasonic transducer surfaceMeasurement Science and Technology, 2018
- Passive focusing techniques for piezoelectric air-coupled ultrasonic transducersUltrasonics, 2016
- Review of air-coupled ultrasonic materials characterizationUltrasonics, 2014
- The development of a shock-tube based characterization technique for air-coupled ultrasonic probesUltrasonics, 2014
- Vibration amplitude and induced temperature limitation of high power air-borne ultrasonic transducersUltrasonics, 2014