Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jan Bauer has a total of 38 co-authors. Here are the top co-authors by number of shared publications:

  • Ondrej Lipcak

    Department of Electric Drives and Traction, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic

    13 shared publications
  • Filip Baum

    Department of Electric Drives and Traction, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic

    4 shared publications
  • Jakub Kucera

    Department of Electric Drives and Traction, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic

    3 shared publications
  • Lettl Jiri

    Department of Electric Drives and Traction, Faculty of Electrical Engineering, Czech Technical University in Prague, Czech Republic

    3 shared publications
  • Pavel Karlovsky

    Czech Technical University in Prague

    3 shared publications
  • S. Fligl

    Faculty of Electrical Engineering, Department of Electric Drives and Traction, Czech Technical University in Prague, Technicka 2, Czech Republic

    3 shared publications

Latest Publications

  • Open Access

    Control Strategy of Matrix Converter Using Different Algorithms with MATLAB Simulink and PLECS

    by Kusuma Priya Krovi, Jan Bauer

    This paper presents a perturb-and-observe-based optimization approach for efficiency maximization and total harmonic distortion (THD) minimization in a 3 × 3 matrix converter under varying D-axis current references (Idref). In matrix converters, the phase shift and modulation index significantly influence power transfer characteristics, harmonic performance, and conversion efficiency. However, fixed-parameter control strategies often fail to maintain optimal performance over varying operating conditions. To address this limitation, two independent perturb-and-observe-based optimization strategies are developed for adaptive phase-shift tuning in efficiency and THD optimization. In both approaches, the modulation index is regulated using a PI controller to maintain stable current regulation and proper voltage utilization. The proposed methods rely only on AC-side measurements, avoiding explicit analytical optimization and enabling simplified implementation within existing converter control frameworks. The effectiveness of the proposed strategies is validated through MATLAB/PLECS simulations of a 3 × 3 matrix converter under multiple operating conditions (Idref=10, 20, and 30 A). The semiconductor switching and conduction losses are included using the Infineon FS13MR12W2M1H device loss model available in the PLECS semiconductor library. The results demonstrate that the adaptive phase-shift adjustment successfully converges toward operating points with improved efficiency and reduced THD compared with conventional fixed-step methods. Furthermore, the proposed perturb-and-observe-based strategy demonstrates good adaptability across varying operating conditions while maintaining relatively low computational complexity, making it suitable for practical real-time implementation in matrix converter applications.

  • Open Access

    Model-Based Mitigation of Low-Order Harmonics in Overmodulated SynRM Drives Considering Cross-Saturation

    by Petr Zakopal, Ondrej Lipcak, Jan Bauer

    Operation of electric drives in the overmodulation region and six-step can optimize switching losses and increase the utilization of the dc-link voltage, but inevitably introduces low-order voltage harmonics that appear as current distortions in the stator winding. These harmonics adversely affect the field-oriented control loops, which in theory operate on fundamental components only. This paper presents an analytical method for mitigating low-order current harmonics in a feedback path of overmodulated Synchronous Reluctance Machine (SynRM) drives controlled under a combined Maximum Torque Per Ampere (MTPA) and Field-Weakening (FW) strategy. The proposed algorithm analytically estimates the 5th, 7th, 11th, and 13th harmonic components using explicit equations and synthesizes compensating current vectors using a machine model with differential inductances that accurately capture magnetic saturation and cross-saturation. Simulation and experimental results obtained on an 11kW SynRM drive confirm a substantial reduction in the $d$ - and $q$ -axis current ripple in the feedback path without deteriorating dynamic performance. The proposed approach enables smooth operation up to the six-step mode and provides a robust foundation for future observer-based or sensorless control schemes that rely chiefly on fundamental current and voltage components.


  • Torque Preservation in DFIG Systems During Voltage Dips With Modulated Stator-Connected Dynamic Braking Resistor

    by Filip Baum, Jesus Lopez, Javier Samanes, Jan Bauer

    This article proposes a novel approach to enhancing the low-voltage ride-through capability of doubly-fed induction generator wind turbines using a dynamically modulated braking resistor (DBR) connected in series with the stator windings. Unlike conventional DBR-based methods that focus primarily on mitigating electrical transients, the proposed approach emphasizes maintaining the generator’s electromagnetic torque at its prefault level during grid voltage dips. The DBR resistance is calculated in real time based on analytical expressions derived from the system’s model. By properly selecting the DBR resistance during the fault, the excess mechanical power that cannot be transferred to the grid is dissipated within the resistor, allowing the generator torque to remain constant during the fault, which helps maintain rotor speed and mitigate electrical transients. The proposed strategy is validated through both simulation and experimental results under symmetrical fault conditions, demonstrating superior torque stability, reduced current transients, and improved postfault recovery compared to fixed-resistance DBR schemes.


  • Efficient Modulation Strategies to Minimize Switching Losses in Dual-Inverter Systems

    by Jakub Kucera, Ondrej Lipcak, Jan Bauer

    The dual-inverter (DI) with galvanically isolated dc supplies offers advantages such as multilevel and fault-tolerant operation, superior dc voltage utilization, and simple control, making it particularly attractive for traction applications. The DI provides significant flexibility in output voltage synthesis by utilizing two conventional voltage-source inverters (VSIs) to supply each end of the load. This article leverages that flexibility by proposing several modulation strategies, where one inverter operates in a six-step (square-wave) mode, and the other utilizes a modified space vector pulse width modulation (SVPWM) or discontinuous pulse width modulation (DPWM). These strategies efficiently reduce switching losses while maintaining low implementation complexity through the reference signal deformation approach. The proposed modulations are theoretically analyzed for switching loss reduction and experimentally validated on an induction machine under closed-loop field-oriented control to confirm their effectiveness compared to conventional approaches.


  • Digital Implementation of Discontinuous PWMs: Mitigating Parasitic Active Vectors for Improved Load Current Quality in Inverter Systems

    by Filip Baum, Ondrej Lipcak, Jakub Kucera, Jan Bauer

    Discontinuous PWM (DPWM) strategies are widely used in Voltage-Source Inverters (VSIs) due to reduced switching losses and improved harmonic performance at higher modulation indexes. However, DPWMs with discontinuous Zero-Sequence Signals (ZSS) can cause current spikes at clamping instants, which depend on the modulation index and load parameters. In the literature, this behavior is often attributed to the rapid changes in ZSS. This paper demonstrates that the current spikes are primarily caused by improper modulator implementation on Digital Signal Processors (DSPs), which introduces an unintended active vector instead of a zero vector at the end of a positive bus clamp for a given phase. The issue arises because PWM modules operate as set-reset units based on a timer and compare values, unlike analog comparators, which react instantaneously. We propose a simple solution using an auxiliary compare register, which is effective for most DSPs. The solution's effectiveness is demonstrated on a VSI-fed 12-kW induction machine controlled by a C2000 Texas Instruments DSP.


  • Hybrid Overmodulation Strategy for Dual Two-Level Inverter With Arbitrary DC-Bus Voltage Distribution

    by Filip Baum, Ondrej Lipcak, Jan Bauer

    This article introduces an innovative overmodulation strategy for a dual two-level inverter topology featuring galvanically isolated dc-links and accommodating arbitrary distribution of dc-bus voltages. In such a configuration, the uneven distribution of dc voltages gives rise to 12 additional fundamental voltage vectors compared with the conventional two-level inverter, effectively enabling the topology to function as a five-level inverter. The primary innovation of our proposed method lies in its ability to transition from linear modulation to what we term an 18-step operation—an improved multilevel square-wave operation of the inverter. This extended operational range is achieved through a hybrid space vector pulsewidth modulation approach, a well-established technique in the context of two-level inverters. Moreover, this article presents a crucial nonlinear gain compensation characteristic essential for real-time control applications. To validate the effectiveness of our approach, we conducted experiments using a custom 15-kW GaN dual inverter. These experiments included the implementation of a straightforward V/Hz control of a 12-kW induction motor supplied by the dual inverter. The results of our experiments confirm the strategy's effectiveness, demonstrating superior current waveform quality and a seamless transition from linear modulation mode to the 18-step operation.


  • Open Access

    MRAS-Based Induction Machine Magnetizing Inductance Estimator With Included Effect of Iron Losses and Load

    by Ondrej Lipcak, Jan Bauer

    Although still widely used due to its robustness, reliability, and low cost, induction motor (IM) has a disadvantage of more complicated mathematical description than permanent magnet AC machines. In high-demanding applications, the decoupled control of the machine’s flux and torque along with the proper function of selected efficiency-improving and flux-weakening algorithms can be achieved only if the IM parameters are known with sufficient accuracy. For parameter estimation, many algorithms have been proposed in the literature so far. Due to its simple and straightforward implementation, one of the popular estimation strategies is the model reference adaptive system (MRAS). However, MRAS-based algorithms for a specific parameter estimation tend to be sensitive to other machine parameters. For instance, most of the proposed MRAS algorithms do not consider the influence of the phenomena such as iron losses and load-dependent saturation. Since one of the most performance-decisive parameters of the popular rotor flux-oriented control (RFOC) are the magnetizing inductance and the rotor resistance, this paper aims to present a novel MRAS-based magnetizing inductance estimator (Lm-MRAS) with the included effect of iron losses. Furthermore, to enable the identification of the load-dependent saturation, another MRAS with included iron losses based on reactive power is proposed to work parallelly with Lm-MRAS, since under load conditions, the rotor resistance mismatch causes RFOC detuning. The adaptation law of the Lm-MRAS is obtained using the Lyapunov function approach and further examined using small-signal analysis. The proposed algorithms are verified on a 3.6 kW IM drive both in simulations and experiments.


  • Open Access

    Influence of Selected Non-Ideal Aspects on Active and Reactive Power MRAS for Stator and Rotor Resistance Estimation

    by Ondrej Lipcak, Filip Baum, Jan Bauer

    Mathematical models of induction motor (IM) used in direct field-oriented control (DFOC) strategies are characterized by parametrization resulting from the IM equivalent circuit and model-type selection. The parameter inaccuracy causes DFOC detuning, which deteriorates the drive performance. Therefore, many methods for parameter adaptation were developed in the literature. One class of algorithms, popular due to their simplicity, includes estimators based on the model reference adaptive system (MRAS). Their main disadvantage is the dependence on other machines’ parameters. However, although typically not considered in the respective literature, there are other aspects that impair the performance of the MRAS estimators. These include, but are not limited to, the nonlinear phenomenon of iron losses, the effect of necessary discretization of the algorithms and selection of the sampling time, and the influence of the supply inverter nonlinear behavior. Therefore, this paper aims to study the effect of the above-mentioned negative aspects on the performance of selected MRAS estimators: active and reactive power MRAS for the stator and rotor resistance estimation. Furthermore, improved reduced-order models and MRAS estimators that consider the iron loss phenomenon are also presented to examine the iron loss influence. Another merit of this paper is that it shows clearly and in one place how DFOC, with the included effect of iron losses and inverter nonlinearities, can be modeled using simulation tools. The modeling of the IM and DFOC takes place in MATLAB/Simulink environment.


  • Adhesion Characteristic Slope Estimation for Wheel Slip Control Purpose Based on UKF

    by Petr Pichlik, Jan Bauer

    Slip controllers are crucial for railway vehicle operation when a high tractive effort is required. The slip controllers have been developed for decades, and their developments continue. The developed slip controllers are based on many more or less effective principles. One of the perspective slip controllers determines a phase shift between an injected excitation signal to the required torque of the electric drive and the signal representation in a measured wheel angular velocity. The slip controllers that are based on the principle can effectively work with any adhesion conditions. However, the slip controller principle has some drawbacks like high filtration requirements, possible failure due to mechanical shock in the wheel-rail contact and long response time. The paper proposes a novel phase shift detection method for the slip controller based on an unscented Kalman filter that can cope with the known disadvantages of the original slip controller. When the proper output of the UKF is used, the slip controller becomes faster, more reliable and can work when the original slip controller fails. The proposed slip controller was verified on the measured data in an open-loop calculation and the mathematical model in the closed-loop simulation.