FBFilip Baum

Filip Baum

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Filip Baum has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Ondrej Lipcak

    Department of Electric Drives and Traction, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic

    5 shared publications
  • Jan Bauer

    Department of Electric Drives and Traction, Czech Technical University in Prague, 160 00 Prague, Czech Republic

    4 shared publications
  • Jakub Kucera

    Department of Electric Drives and Traction, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic

    2 shared publications
  • Javier Samanes

    Department of Electrical, Electronic and Communications Engineering, Institute of Smart Cities, Public University of Navarre, Pamplona, Spain

    1 shared publication
  • Jesus Lopez

    School of Industrial and Telecommunications Engineering, Public University of Navarre, 31006 Pamplona, Spain

    1 shared publication
  • Petr Zakopal

    Department of Electric Drives and Traction, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic

    1 shared publication

Latest Publications

  • Torque Preservation in DFIG Systems During Voltage Dips With Modulated Stator-Connected Dynamic Braking Resistor

    by Filip Baum, Jesus Lopez, Javier Samanes, Jan Bauer

    This article proposes a novel approach to enhancing the low-voltage ride-through capability of doubly-fed induction generator wind turbines using a dynamically modulated braking resistor (DBR) connected in series with the stator windings. Unlike conventional DBR-based methods that focus primarily on mitigating electrical transients, the proposed approach emphasizes maintaining the generator’s electromagnetic torque at its prefault level during grid voltage dips. The DBR resistance is calculated in real time based on analytical expressions derived from the system’s model. By properly selecting the DBR resistance during the fault, the excess mechanical power that cannot be transferred to the grid is dissipated within the resistor, allowing the generator torque to remain constant during the fault, which helps maintain rotor speed and mitigate electrical transients. The proposed strategy is validated through both simulation and experimental results under symmetrical fault conditions, demonstrating superior torque stability, reduced current transients, and improved postfault recovery compared to fixed-resistance DBR schemes.


  • Digital Implementation of Discontinuous PWMs: Mitigating Parasitic Active Vectors for Improved Load Current Quality in Inverter Systems

    by Filip Baum, Ondrej Lipcak, Jakub Kucera, Jan Bauer

    Discontinuous PWM (DPWM) strategies are widely used in Voltage-Source Inverters (VSIs) due to reduced switching losses and improved harmonic performance at higher modulation indexes. However, DPWMs with discontinuous Zero-Sequence Signals (ZSS) can cause current spikes at clamping instants, which depend on the modulation index and load parameters. In the literature, this behavior is often attributed to the rapid changes in ZSS. This paper demonstrates that the current spikes are primarily caused by improper modulator implementation on Digital Signal Processors (DSPs), which introduces an unintended active vector instead of a zero vector at the end of a positive bus clamp for a given phase. The issue arises because PWM modules operate as set-reset units based on a timer and compare values, unlike analog comparators, which react instantaneously. We propose a simple solution using an auxiliary compare register, which is effective for most DSPs. The solution's effectiveness is demonstrated on a VSI-fed 12-kW induction machine controlled by a C2000 Texas Instruments DSP.


  • Hybrid Overmodulation Strategy for Dual Two-Level Inverter With Arbitrary DC-Bus Voltage Distribution

    by Filip Baum, Ondrej Lipcak, Jan Bauer

    This article introduces an innovative overmodulation strategy for a dual two-level inverter topology featuring galvanically isolated dc-links and accommodating arbitrary distribution of dc-bus voltages. In such a configuration, the uneven distribution of dc voltages gives rise to 12 additional fundamental voltage vectors compared with the conventional two-level inverter, effectively enabling the topology to function as a five-level inverter. The primary innovation of our proposed method lies in its ability to transition from linear modulation to what we term an 18-step operation—an improved multilevel square-wave operation of the inverter. This extended operational range is achieved through a hybrid space vector pulsewidth modulation approach, a well-established technique in the context of two-level inverters. Moreover, this article presents a crucial nonlinear gain compensation characteristic essential for real-time control applications. To validate the effectiveness of our approach, we conducted experiments using a custom 15-kW GaN dual inverter. These experiments included the implementation of a straightforward V/Hz control of a 12-kW induction motor supplied by the dual inverter. The results of our experiments confirm the strategy's effectiveness, demonstrating superior current waveform quality and a seamless transition from linear modulation mode to the 18-step operation.


  • Open Access

    Modulation Techniques and Coordinated Voltage Vector Distribution: Effects on Efficiency in Dual-Inverter Topology-Based Electric Drives

    by Jakub Kucera, Petr Zakopal, Filip Baum, Ondrej Lipcak

    The increasing popularity of electric drives employing an isolated dual-inverter (DI) topology is motivated by their superior DC-link voltage and power utilization, fault-tolerant operation, and potential for multilevel operation. These attributes are significant in battery-powered transportation, such as electric vehicles and aviation. Given the considerable freedom in modulation and control of the DI topology, this paper researches the impact of reference voltage vector distribution between the two individual inverters. The study also evaluates the influence of two well-established asynchronous modulation strategies—Space Vector PWM (SVPWM) and Depenbrock’s Discontinuous Modulation (DPWM1). Since simulation tools nowadays play a crucial role in power electronics design and concept verification, the results are based on extensive and detailed models in Matlab/Simulink. Employing the basic field-oriented control of a 12 kW induction motor with precisely parameterized SiC switching devices for accurate loss calculation, this research reveals the possibility of significant energy savings at multiple operating points. Notably, optimal efficiency is achieved when one inverter operates up to half of the nominal speed while the other solely establishes a neutral point for the winding. Moreover, the results highlight DPWM1 as a superior strategy for the DI topology, showcasing reduced converter losses. Overall, it is shown that the system’s losses can be significantly reduced just by the design of the voltage vector distribution in the drive’s operating range and the modulation strategy selection.


  • Hybrid Overmodulation Strategy of Dual Two-Level Inverter Topology Enabling 12-Step Operation

    by Filip Baum, Ondrej Lipcak

    This paper introduces a novel overmodulation strategy tailored for dual-inverter topologies with galvanically isolated DC-links and evenly distributed DC-link voltage. The core contribution of the paper is the utilization of the multilevel capabilities of the dual-inverter topology. At the maximum modulation index, the presented overmodulation method achieves what is referred to as a 12-step operation. The 12-step operation improves the voltage waveform and offers superior harmonic performance compared to the conventional 6-step operation. The utilized approach leverages a hybrid Space Vector Pulse Width Modulation (SVPWM) method, a well-established technique in two-level inverters, to achieve this extended operation range. Furthermore, the paper presents a nonlinear gain compensation characteristic vital for real-time motor control applications and provides a comparative analysis of the modulation's harmonic performance. The proposed approach is validated through simulations and experiments. The experiments were conducted using a custom inverter based on Gallium-Nitride (GaN) transistors where simple volt/hertz control of an induction motor was programmed. The results of these experiments affirm the strategy's effectiveness, showcasing superior current waveform quality and a smooth transition from linear mode to 12-step operation while keeping a simple implementation of the algorithm.


  • Open Access

    Influence of Selected Non-Ideal Aspects on Active and Reactive Power MRAS for Stator and Rotor Resistance Estimation

    by Ondrej Lipcak, Filip Baum, Jan Bauer

    Mathematical models of induction motor (IM) used in direct field-oriented control (DFOC) strategies are characterized by parametrization resulting from the IM equivalent circuit and model-type selection. The parameter inaccuracy causes DFOC detuning, which deteriorates the drive performance. Therefore, many methods for parameter adaptation were developed in the literature. One class of algorithms, popular due to their simplicity, includes estimators based on the model reference adaptive system (MRAS). Their main disadvantage is the dependence on other machines’ parameters. However, although typically not considered in the respective literature, there are other aspects that impair the performance of the MRAS estimators. These include, but are not limited to, the nonlinear phenomenon of iron losses, the effect of necessary discretization of the algorithms and selection of the sampling time, and the influence of the supply inverter nonlinear behavior. Therefore, this paper aims to study the effect of the above-mentioned negative aspects on the performance of selected MRAS estimators: active and reactive power MRAS for the stator and rotor resistance estimation. Furthermore, improved reduced-order models and MRAS estimators that consider the iron loss phenomenon are also presented to examine the iron loss influence. Another merit of this paper is that it shows clearly and in one place how DFOC, with the included effect of iron losses and inverter nonlinearities, can be modeled using simulation tools. The modeling of the IM and DFOC takes place in MATLAB/Simulink environment.