HTHiroaki Takehara

Hiroaki Takehara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hiroaki Takehara has a total of 156 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dual-Readout Self-Resetting CMOS Image Sensor for Resolving Sub-Percent Optical Contrast in Biomedical Imaging

    by Kiyotaka Sasagawa, Subaru Iwaki, Kenji Morimoto, Ryoma Okada, Hironari Takehara, Makito Haruta, Hiroyuki Tashiro, Jun Ohta

    We report a dual-readout self-resetting CMOS image sensor that achieves a signal-to-noise ratio (SNR) exceeding 70 dB and resolves sub-percent optical contrast variations by effectivly suppressing reset artifacts. The proposed sensor employs a Dual-Readout architecture with two independent scanners operating with a temporal offset; while one readout system is in the self-reset “dead time”, the other remains active, thereby physically ensuring continuous data acquisition. To minimize pixel area while achieving high reconstruction accuracy, a minimum frame-to-frame difference algorithm is utilized for signal restoration without requiring in-pixel counters. A prototype chip fabricated in a 0.35-μm process demonstrated SNR characteristics near the shot-noise limit, with a peak SNR exceeding 70 dB. Vascular phantom experiments using a carbon black suspension successfully visualized ±0.25% contrast fluctuations—dynamic signals previously undetectable by conventional sensors. This device provides a powerful platform for high-precision bio-imaging applications, including brain surface blood flow monitoring, where both wide dynamic range and high SNR are essential.

  • Open Access

    Development of an optical microneedle device embedding sub-nanoliter volumes of boronic acid-based fluorescent hydrogel

    by Masahiro Fukuhara, Hiroaki Takehara, Kevin Barthelmes, Benjamin Kersch-Hunt, Jordan E. Gardiner, Yukihiro Kanda, Akira Matsumoto, Tony D. James, Takanori Ichiki

    Fluorescence-based optical microneedles enable non-consumptive molecular sensing within a small volume (0.79 nL) at the tip, showing an average measurement error of 5.6% for d -glucose concentrations (6.1–37.5 mM).


  • Open Access

    Performance Improvement of Polarization Image Sensor with Multilayer On-Pixel Polarizer Structure for High-Sensitivity Millimeter-Wave Electro-Optic Imaging

    by Ryoma Okada, Maya Mizuno, Hironari Takehara, Makito Haruta, Hiroyuki Tashiro, Jun Ohta, Kiyotaka Sasagawa

    In this paper, we demonstrated a high-sensitivity polarization image sensor for millimeter-wave electric field imaging using electro-optic crystals. We developed a three-layer on-pixel polarizer structure fabricated with a 0.35-µm standard CMOS process, achieving an extinction ratio of 5.7, which corresponds to a 73% improvement over previous two-layer structure. Crosstalk reduction was implemented by applying a bias voltage to the n-well pixel separation, and extinction ratio was further improved. By using an improved sensor, it demonstrated a 7.6 dB SNR improvement in 30 GHz electric field imaging compared to previous sensors, despite 30% transmittance reduction. Angular dependence analysis confirmed adequate performance within the optical system’s constraints. These results enable high-speed and high-sensitivity millimeter-wave imaging applications.

  • Open Access

    Microfabrication of Mo Electrodes on Bioabsorbable Polymer Substrates and Its Application to a Needle-Type Electrode Formation

    by Hiroaki Takehara, Kazuki Shimada, Kota Naito, Takanori Ichiki

    Bioabsorbable polymers are highly attractive as safe and minimally invasive materials for constructing implantable and semi-implantable medical devices used in/on the human body. Currently, microfabrication for device miniaturization is under investigation. This study proposes the use of bioabsorbable polymers including poly(L-lactic acid) (PLLA) as substrate materials for highly safe and minimally invasive biomedical sensors. The aim is to design a fabrication technique for forming metal wires and electrodes on PLLA substrates, which are the most commonly used bioabsorbable materials, for future applications as minimally invasive biomedical devices including microneedles. PLLA substrates are subjected to industrially feasible fabrications including molding, O2 plasma treatment, sputtering, and laser ablation. Then, the substrates are characterized by atomic force microscopy, contact angle measurements, X-ray photoelectron spectroscopy, scanning electron microscopy, and energy-dispersive X-ray spectroscopy. Adhesion at the metal/polymer interface is enhanced through a combination of physical and chemical effects to improve the quality of metal wires formed on the substrate. Finally, microneedle-type electrodes are fabricated using the developed microfabrication technique are demonstrated. The microfabrication of bioabsorbable polymers and metals is anticipated to contribute to the development of highly safe and minimally invasive medical devices used in/on the human body. The novel microfabrication technique developed in this study is applicable to (i) bioabsorbable polymer/metal materials without the use of chemical solvents and harsh conditions, and (ii) the formation of metal electrodes on both two- and three-dimensional microstructures. Graphical Abstract

  • Open Access

    Microwave electro-optical imaging system using a frequency tracking optical local oscillator source with a polarization CMOS image sensor

    by Ryoma Okada, Maya Mizuno, Hironari Takehara, Makito Haruta, Hiroyuki Tashiro, Jun Ohta, Kiyotaka Sasagawa

    In this study, we developed a high-frequency electric field imaging system based on the first-order electro-optic effect for the detection of time-varying frequency wave sources. The proposed system utilizes the optical heterodyne technique. The process begins with an antenna that detects the frequency of the electric field of interest, which is then fed into the optical local oscillator (LO) signal generation system. This optical LO signal tracks the frequency of the electric field being observed while maintaining a constant intermediate frequency. This configuration enables the visualization of dynamic electric fields, including asynchronous wave sources and frequency-modulated signals, without requiring a direct physical connection to the wave source. In this study, we present the development of a high-frequency electric field imaging system based on the first-order electro-optic effect for the detection of time-varying frequency wave sources. The proposed system utilizes the optical heterodyne technique. The process begins with an antenna that detects the frequency of the electric field of interest, which is then fed into the optical local oscillator (LO) signal generation system. This optical LO signal is designed to follow the frequency of the electric field being observed while maintaining a constant intermediate frequency. This configuration facilitates accurate electric field imaging and enables the visualization of dynamic electric fields, including asynchronous wave sources and frequency-modulated signals, without requiring a direct physical connection to the wave source.


  • Open Access

    Enhancing Image Reconstruction Method in High-Frequency Electric Field Visualization Systems Using a Polarized Light Image Sensor

    by Kiyotaka Sasagawa, Ryoma Okada, Maya Mizuno, Hironari Takehara, Makito Haruta, Hiroyuki Tashiro, Jun Ohta

    This paper introduces an image processing method, used to achieve uniform sensitivity across the imaging plane in a high-frequency electric field imaging system, that employs an electro-optical crystal and a polarization image sensor. The polarization pixels have two polarization directions, 0° and 90°, in pairs, and, conventionally, their difference is computed first. In contrast, this study proposes a method to separate each polarization image, perform pixel completion, and subsequently perform intensity correction. The proposed method was demonstrated to improve field distribution images acquired using 36 GHz and 30 GHz input signals for a microstrip line and patch antenna, respectively. From the measurement results of the microstrip line, the application of the proposed method reduced the electric field fluctuations on the line from 3.1 dB to 1.5 dB. This image-processing method can be applied sequentially during image acquisition, making it suitable for the real-time imaging of electric fields.


  • Design of CMOS chip for retinal prosthesis with power supply voltage monitoring circuit for stabilizing constant-current stimulation

    by Yuki Nakanishi, Takaya Hattori, Wisaroot Sriitsaranusorn, Kuang-Chih Tso, Kenzo Shodo, Hironari Takehara, Yoshinori Sunaga, Makito Haruta, Hiroyuki Tashiro, Yasuo Terasawa, et al.

    To advance the practical application of retinal prostheses with high spatial resolution through parallel stimulation, we developed a dynamic power supply voltage control system designed to enable stable constant-current stimulation in vivo, regardless of the number of active stimulation points. The proposed retinal prosthesis integrates a CMOS chip, containing current sources and electrode selection circuits, into a stimulation electrode array implanted in the eye. This configuration facilitates individual control of over 1000 electrodes with minimal wiring. In this study, we designed and integrated a power supply voltage monitoring circuit into the chip, allowing for real-time control of an external power generation circuit through feedback from the intraocular monitoring circuit. We demonstrated that the proposed system rapidly restored the power supply voltage when a voltage drop of 1 V occurred in the Pt wiring between the power supply unit and the chip, even while delivering a stimulation current of 1.5 mA in parallel across more than 100 electrodes.

  • Open Access

    Millimeter-Wave Band Electro-Optical Imaging System Using Polarization CMOS Image Sensor and Amplified Optical Local Oscillator Source

    by Ryoma Okada, Maya Mizuno, Tomoaki Nagaoka, Hironari Takehara, Makito Haruta, Hiroyuki Tashiro, Jun Ohta, Kiyotaka Sasagawa

    In this study, we developed and demonstrated a millimeter-wave electric field imaging system using an electro-optic crystal and a highly sensitive polarization measurement technique using a polarization image sensor, which was fabricated using a 0.35-µm standard CMOS process. The polarization image sensor was equipped with differential amplifiers that amplified the difference between the 0° and 90° pixels. With the amplifier, the signal-to-noise ratio at low incident light levels was improved. Also, an optical modulator and a semiconductor optical amplifier were used to generate an optical local oscillator (LO) signal with a high modulation accuracy and sufficient optical intensity. By combining the amplified LO signal and a highly sensitive polarization imaging system, we successfully performed millimeter-wave electric field imaging with a spatial resolution of 30×60 µm at a rate of 1 FPS, corresponding to 2400 pixels/s.