Makito Haruta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Makito Haruta has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Jun Ohta
Nara Institute of Science and Technology
30 shared publications - Kiyotaka Sasagawa
Division of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Nara, Japan
29 shared publications - Hiroaki Takehara
Division of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Nara, Japan
25 shared publications - Hiroyuki Tashiro
Division of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Nara, Japan
21 shared publications - Ryoma Okada
Division of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Nara, Japan
9 shared publications - Yasumi Ohta
Division of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, Ikoma 630-0101, Japan
7 shared publications
Latest Publications
- Open Access
Dual-Readout Self-Resetting CMOS Image Sensor for Resolving Sub-Percent Optical Contrast in Biomedical Imaging
We report a dual-readout self-resetting CMOS image sensor that achieves a signal-to-noise ratio (SNR) exceeding 70 dB and resolves sub-percent optical contrast variations by effectivly suppressing reset artifacts. The proposed sensor employs a Dual-Readout architecture with two independent scanners operating with a temporal offset; while one readout system is in the self-reset “dead time”, the other remains active, thereby physically ensuring continuous data acquisition. To minimize pixel area while achieving high reconstruction accuracy, a minimum frame-to-frame difference algorithm is utilized for signal restoration without requiring in-pixel counters. A prototype chip fabricated in a 0.35-m process demonstrated SNR characteristics near the shot-noise limit, with a peak SNR exceeding 70 dB. Vascular phantom experiments using a carbon black suspension successfully visualized ±0.25% contrast fluctuations—dynamic signals previously undetectable by conventional sensors. This device provides a powerful platform for high-precision bio-imaging applications, including brain surface blood flow monitoring, where both wide dynamic range and high SNR are essential.Open AccessDual-Readout Self-Resetting CMOS Image Sensor for Resolving Sub-Percent Optical Contrast in Biomedical Imaging
We report a dual-readout self-resetting CMOS image sensor that achieves a signal-to-noise ratio (SNR) exceeding 70 dB and resolves sub-percent optical contrast variations by effectivly suppressing reset artifacts. The proposed sensor employs a Dual-Readout architecture with two independent scanners operating with a temporal offset; while one readout system is in the self-reset “dead time”, the other remains active, thereby physically ensuring continuous data acquisition. To minimize pixel area while achieving high reconstruction accuracy, a minimum frame-to-frame difference algorithm is utilized for signal restoration without requiring in-pixel counters. A prototype chip fabricated in a 0.35-m process demonstrated SNR characteristics near the shot-noise limit, with a peak SNR exceeding 70 dB. Vascular phantom experiments using a carbon black suspension successfully visualized ±0.25% contrast fluctuations—dynamic signals previously undetectable by conventional sensors. This device provides a powerful platform for high-precision bio-imaging applications, including brain surface blood flow monitoring, where both wide dynamic range and high SNR are essential. - Open Access
- 14 October 2025
- Published by MDPI AG in Electronics
- Vol. 14 (20) , 4026
Performance Improvement of Polarization Image Sensor with Multilayer On-Pixel Polarizer Structure for High-Sensitivity Millimeter-Wave Electro-Optic Imaging
In this paper, we demonstrated a high-sensitivity polarization image sensor for millimeter-wave electric field imaging using electro-optic crystals. We developed a three-layer on-pixel polarizer structure fabricated with a 0.35-µm standard CMOS process, achieving an extinction ratio of 5.7, which corresponds to a 73% improvement over previous two-layer structure. Crosstalk reduction was implemented by applying a bias voltage to the n-well pixel separation, and extinction ratio was further improved. By using an improved sensor, it demonstrated a 7.6 dB SNR improvement in 30 GHz electric field imaging compared to previous sensors, despite 30% transmittance reduction. Angular dependence analysis confirmed adequate performance within the optical system’s constraints. These results enable high-speed and high-sensitivity millimeter-wave imaging applications.
- 14 October 2025
- Published by MDPI AG in Electronics
- Vol. 14 (20) , 4026
Open AccessPerformance Improvement of Polarization Image Sensor with Multilayer On-Pixel Polarizer Structure for High-Sensitivity Millimeter-Wave Electro-Optic Imaging
In this paper, we demonstrated a high-sensitivity polarization image sensor for millimeter-wave electric field imaging using electro-optic crystals. We developed a three-layer on-pixel polarizer structure fabricated with a 0.35-µm standard CMOS process, achieving an extinction ratio of 5.7, which corresponds to a 73% improvement over previous two-layer structure. Crosstalk reduction was implemented by applying a bias voltage to the n-well pixel separation, and extinction ratio was further improved. By using an improved sensor, it demonstrated a 7.6 dB SNR improvement in 30 GHz electric field imaging compared to previous sensors, despite 30% transmittance reduction. Angular dependence analysis confirmed adequate performance within the optical system’s constraints. These results enable high-speed and high-sensitivity millimeter-wave imaging applications.
- Open Access
- 15 May 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (5) , 580
Development and Evaluation of Multi-Module Retinal Devices for Artificial Vision Applications
Artificial retinal devices require a high-density electrode array and mechanical flexibility to effectively stimulate retinal cells. However, designing such devices presents significant challenges, including the need to conform to the curvature of the eyeball and cover a large area using a single platform. To address these issues, we developed a parylene-based multi-module retinal device (MMRD) integrating a complementary metal-oxide semiconductor (CMOS) system. The proposed device is designed for suprachoroidal transretinal stimulation, with each module comprising a parylene-C thin-film substrate, a CMOS chip, and a ceramic substrate housing seven platinum electrodes. The smart CMOS system significantly reduces wiring complexity, enhancing the device’s practicality. To improve fabrication reliability, we optimized the encapsulation process, introduced multiple silane coupling modifications, and utilized polyvinyl alcohol (PVA) for easier detachment in flip-chip bonding. This study demonstrates the fabrication and evaluation of the MMRD through in vitro and in vivo experiments. The device successfully generated the expected current stimulation waveforms in both settings, highlighting its potential as a promising candidate for future artificial vision applications.
- 15 May 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (5) , 580
Open AccessDevelopment and Evaluation of Multi-Module Retinal Devices for Artificial Vision Applications
Artificial retinal devices require a high-density electrode array and mechanical flexibility to effectively stimulate retinal cells. However, designing such devices presents significant challenges, including the need to conform to the curvature of the eyeball and cover a large area using a single platform. To address these issues, we developed a parylene-based multi-module retinal device (MMRD) integrating a complementary metal-oxide semiconductor (CMOS) system. The proposed device is designed for suprachoroidal transretinal stimulation, with each module comprising a parylene-C thin-film substrate, a CMOS chip, and a ceramic substrate housing seven platinum electrodes. The smart CMOS system significantly reduces wiring complexity, enhancing the device’s practicality. To improve fabrication reliability, we optimized the encapsulation process, introduced multiple silane coupling modifications, and utilized polyvinyl alcohol (PVA) for easier detachment in flip-chip bonding. This study demonstrates the fabrication and evaluation of the MMRD through in vitro and in vivo experiments. The device successfully generated the expected current stimulation waveforms in both settings, highlighting its potential as a promising candidate for future artificial vision applications.
- Open Access
- 10 March 2025
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Electronics Express
- Vol. 22 (5) , 20240742
Microwave electro-optical imaging system using a frequency tracking optical local oscillator source with a polarization CMOS image sensor
In this study, we developed a high-frequency electric field imaging system based on the first-order electro-optic effect for the detection of time-varying frequency wave sources. The proposed system utilizes the optical heterodyne technique. The process begins with an antenna that detects the frequency of the electric field of interest, which is then fed into the optical local oscillator (LO) signal generation system. This optical LO signal tracks the frequency of the electric field being observed while maintaining a constant intermediate frequency. This configuration enables the visualization of dynamic electric fields, including asynchronous wave sources and frequency-modulated signals, without requiring a direct physical connection to the wave source. In this study, we present the development of a high-frequency electric field imaging system based on the first-order electro-optic effect for the detection of time-varying frequency wave sources. The proposed system utilizes the optical heterodyne technique. The process begins with an antenna that detects the frequency of the electric field of interest, which is then fed into the optical local oscillator (LO) signal generation system. This optical LO signal is designed to follow the frequency of the electric field being observed while maintaining a constant intermediate frequency. This configuration facilitates accurate electric field imaging and enables the visualization of dynamic electric fields, including asynchronous wave sources and frequency-modulated signals, without requiring a direct physical connection to the wave source.
- 10 March 2025
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Electronics Express
- Vol. 22 (5) , 20240742
Open AccessMicrowave electro-optical imaging system using a frequency tracking optical local oscillator source with a polarization CMOS image sensor
In this study, we developed a high-frequency electric field imaging system based on the first-order electro-optic effect for the detection of time-varying frequency wave sources. The proposed system utilizes the optical heterodyne technique. The process begins with an antenna that detects the frequency of the electric field of interest, which is then fed into the optical local oscillator (LO) signal generation system. This optical LO signal tracks the frequency of the electric field being observed while maintaining a constant intermediate frequency. This configuration enables the visualization of dynamic electric fields, including asynchronous wave sources and frequency-modulated signals, without requiring a direct physical connection to the wave source. In this study, we present the development of a high-frequency electric field imaging system based on the first-order electro-optic effect for the detection of time-varying frequency wave sources. The proposed system utilizes the optical heterodyne technique. The process begins with an antenna that detects the frequency of the electric field of interest, which is then fed into the optical local oscillator (LO) signal generation system. This optical LO signal is designed to follow the frequency of the electric field being observed while maintaining a constant intermediate frequency. This configuration facilitates accurate electric field imaging and enables the visualization of dynamic electric fields, including asynchronous wave sources and frequency-modulated signals, without requiring a direct physical connection to the wave source.
- Open Access
Enhancing Image Reconstruction Method in High-Frequency Electric Field Visualization Systems Using a Polarized Light Image Sensor
This paper introduces an image processing method, used to achieve uniform sensitivity across the imaging plane in a high-frequency electric field imaging system, that employs an electro-optical crystal and a polarization image sensor. The polarization pixels have two polarization directions, 0° and 90°, in pairs, and, conventionally, their difference is computed first. In contrast, this study proposes a method to separate each polarization image, perform pixel completion, and subsequently perform intensity correction. The proposed method was demonstrated to improve field distribution images acquired using 36 GHz and 30 GHz input signals for a microstrip line and patch antenna, respectively. From the measurement results of the microstrip line, the application of the proposed method reduced the electric field fluctuations on the line from 3.1 dB to 1.5 dB. This image-processing method can be applied sequentially during image acquisition, making it suitable for the real-time imaging of electric fields.
Open AccessEnhancing Image Reconstruction Method in High-Frequency Electric Field Visualization Systems Using a Polarized Light Image Sensor
This paper introduces an image processing method, used to achieve uniform sensitivity across the imaging plane in a high-frequency electric field imaging system, that employs an electro-optical crystal and a polarization image sensor. The polarization pixels have two polarization directions, 0° and 90°, in pairs, and, conventionally, their difference is computed first. In contrast, this study proposes a method to separate each polarization image, perform pixel completion, and subsequently perform intensity correction. The proposed method was demonstrated to improve field distribution images acquired using 36 GHz and 30 GHz input signals for a microstrip line and patch antenna, respectively. From the measurement results of the microstrip line, the application of the proposed method reduced the electric field fluctuations on the line from 3.1 dB to 1.5 dB. This image-processing method can be applied sequentially during image acquisition, making it suitable for the real-time imaging of electric fields.
- 1 January 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (1) , 01SP08
Design of CMOS chip for retinal prosthesis with power supply voltage monitoring circuit for stabilizing constant-current stimulation
To advance the practical application of retinal prostheses with high spatial resolution through parallel stimulation, we developed a dynamic power supply voltage control system designed to enable stable constant-current stimulation in vivo, regardless of the number of active stimulation points. The proposed retinal prosthesis integrates a CMOS chip, containing current sources and electrode selection circuits, into a stimulation electrode array implanted in the eye. This configuration facilitates individual control of over 1000 electrodes with minimal wiring. In this study, we designed and integrated a power supply voltage monitoring circuit into the chip, allowing for real-time control of an external power generation circuit through feedback from the intraocular monitoring circuit. We demonstrated that the proposed system rapidly restored the power supply voltage when a voltage drop of 1 V occurred in the Pt wiring between the power supply unit and the chip, even while delivering a stimulation current of 1.5 mA in parallel across more than 100 electrodes.
- 1 January 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (1) , 01SP08
Design of CMOS chip for retinal prosthesis with power supply voltage monitoring circuit for stabilizing constant-current stimulation
To advance the practical application of retinal prostheses with high spatial resolution through parallel stimulation, we developed a dynamic power supply voltage control system designed to enable stable constant-current stimulation in vivo, regardless of the number of active stimulation points. The proposed retinal prosthesis integrates a CMOS chip, containing current sources and electrode selection circuits, into a stimulation electrode array implanted in the eye. This configuration facilitates individual control of over 1000 electrodes with minimal wiring. In this study, we designed and integrated a power supply voltage monitoring circuit into the chip, allowing for real-time control of an external power generation circuit through feedback from the intraocular monitoring circuit. We demonstrated that the proposed system rapidly restored the power supply voltage when a voltage drop of 1 V occurred in the Pt wiring between the power supply unit and the chip, even while delivering a stimulation current of 1.5 mA in parallel across more than 100 electrodes.
- Open Access
Millimeter-Wave Band Electro-Optical Imaging System Using Polarization CMOS Image Sensor and Amplified Optical Local Oscillator Source
In this study, we developed and demonstrated a millimeter-wave electric field imaging system using an electro-optic crystal and a highly sensitive polarization measurement technique using a polarization image sensor, which was fabricated using a 0.35-µm standard CMOS process. The polarization image sensor was equipped with differential amplifiers that amplified the difference between the 0° and 90° pixels. With the amplifier, the signal-to-noise ratio at low incident light levels was improved. Also, an optical modulator and a semiconductor optical amplifier were used to generate an optical local oscillator (LO) signal with a high modulation accuracy and sufficient optical intensity. By combining the amplified LO signal and a highly sensitive polarization imaging system, we successfully performed millimeter-wave electric field imaging with a spatial resolution of µm at a rate of 1 FPS, corresponding to 2400 pixels/s.Open AccessMillimeter-Wave Band Electro-Optical Imaging System Using Polarization CMOS Image Sensor and Amplified Optical Local Oscillator Source
In this study, we developed and demonstrated a millimeter-wave electric field imaging system using an electro-optic crystal and a highly sensitive polarization measurement technique using a polarization image sensor, which was fabricated using a 0.35-µm standard CMOS process. The polarization image sensor was equipped with differential amplifiers that amplified the difference between the 0° and 90° pixels. With the amplifier, the signal-to-noise ratio at low incident light levels was improved. Also, an optical modulator and a semiconductor optical amplifier were used to generate an optical local oscillator (LO) signal with a high modulation accuracy and sufficient optical intensity. By combining the amplified LO signal and a highly sensitive polarization imaging system, we successfully performed millimeter-wave electric field imaging with a spatial resolution of µm at a rate of 1 FPS, corresponding to 2400 pixels/s. - 1 March 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (3) , 03SP66
THz near-field intensity distribution imaging in the 0.3 THz band using a highly sensitive polarization CMOS image sensor using a 0.35 μm CMOS process
In this paper, we propose a low-disturbance and fast terahertz (THz) near-field intensity distribution imaging method. The THz detector is fabricated using an oriented multiwalled carbon nanotube (CNT) thin film and a LiNbO3(LN) crystal to the thin film is attached. The CNT absorbs and converts THz waves into heat, and the birefringence change of the LN crystal owing to the heat is used. The birefringence change was measured with high sensitivity using a dual-polarizer configuration of a uniform polarizer and a polarization CMOS image sensor. The fabricated THz detector is a low-disturbance method because it does not use metal, and it can measure the THz distribution in the plane all at once, which is faster than the antenna scanning method. Using the proposed method, we have successfully imaged the THz near-field intensity distribution emitted from an impact avalanche and transit time diode oscillating at 0.278 THz.
- 1 March 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (3) , 03SP66
THz near-field intensity distribution imaging in the 0.3 THz band using a highly sensitive polarization CMOS image sensor using a 0.35 μm CMOS process
In this paper, we propose a low-disturbance and fast terahertz (THz) near-field intensity distribution imaging method. The THz detector is fabricated using an oriented multiwalled carbon nanotube (CNT) thin film and a LiNbO3(LN) crystal to the thin film is attached. The CNT absorbs and converts THz waves into heat, and the birefringence change of the LN crystal owing to the heat is used. The birefringence change was measured with high sensitivity using a dual-polarizer configuration of a uniform polarizer and a polarization CMOS image sensor. The fabricated THz detector is a low-disturbance method because it does not use metal, and it can measure the THz distribution in the plane all at once, which is faster than the antenna scanning method. Using the proposed method, we have successfully imaged the THz near-field intensity distribution emitted from an impact avalanche and transit time diode oscillating at 0.278 THz.
- Open Access
Exposure Time Control Method for Higher Intermediate Frequency in Optical Heterodyne Imaging and Its Application to Electric-Field Imaging Based on Electro-Optic Effect
We propose and demonstrate a method for equivalent time sampling using image sensors to selectively detect only the target frequency. Shortening the exposure time of the image sensor and using equivalent time sampling allows for the detection of frequency components that are higher than the frame rate. However, the imaging system in our previous work was also sensitive to the frequency component at 1/4 of the frame rate. In this study, we control the phase relationship between the exposure time and observed signal by inserting an additional interval once every four frames to detect the target frequency selectively. With this technique, we conducted electric field imaging based on the electro-optic effect under high noise conditions in the low-frequency band to which the conventional method is sensitive. The results demonstrated that the proposed method improved the signal-to-noise ratio.
Open AccessExposure Time Control Method for Higher Intermediate Frequency in Optical Heterodyne Imaging and Its Application to Electric-Field Imaging Based on Electro-Optic Effect
We propose and demonstrate a method for equivalent time sampling using image sensors to selectively detect only the target frequency. Shortening the exposure time of the image sensor and using equivalent time sampling allows for the detection of frequency components that are higher than the frame rate. However, the imaging system in our previous work was also sensitive to the frequency component at 1/4 of the frame rate. In this study, we control the phase relationship between the exposure time and observed signal by inserting an additional interval once every four frames to detect the target frequency selectively. With this technique, we conducted electric field imaging based on the electro-optic effect under high noise conditions in the low-frequency band to which the conventional method is sensitive. The results demonstrated that the proposed method improved the signal-to-noise ratio.
- 14 February 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (3) , 03SP22
Demonstration of multi-point stimulation with AC-driven CMOS chips for retinal prosthesis
We demonstrated a multi-point stimulation system using CMOS chips designed for distributed implantable retinal prostheses. The CMOS chip integrates current sources and electrode selection circuits. This integration enables stimulation current control from multiple electrodes with minimal wires. In this study, we constructed a validation system with 49 electrodes capable of visually observing stimulation current outputs. The validation results show that it is possible to configure stimulation conditions in approximately 9.3 μs per electrode, and we demonstrated the ability to complete one frame, including the stimulation time, within approximately 11 ms. We also demonstrated parallel current stimulation from multiple electrodes using an in vitro experiment.
- 14 February 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (3) , 03SP22
Demonstration of multi-point stimulation with AC-driven CMOS chips for retinal prosthesis
We demonstrated a multi-point stimulation system using CMOS chips designed for distributed implantable retinal prostheses. The CMOS chip integrates current sources and electrode selection circuits. This integration enables stimulation current control from multiple electrodes with minimal wires. In this study, we constructed a validation system with 49 electrodes capable of visually observing stimulation current outputs. The validation results show that it is possible to configure stimulation conditions in approximately 9.3 μs per electrode, and we demonstrated the ability to complete one frame, including the stimulation time, within approximately 11 ms. We also demonstrated parallel current stimulation from multiple electrodes using an in vitro experiment.