Mahdi Eshghi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mahdi Eshghi has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Sameer M. Ikhdair
9 shared publicationsH. Mehraban
Semnan University
8 shared publicationsS. M. Ikhdair
Department of Physics Faculty of Science An-Najah National University Nablus Palestine
7 shared publications- Mohammadreza Alipoor
Faculty of Basic Sciences, Imam Hossein University, Tehran, Iran
6 shared publications M. Hamzavi
Department of Physics University of Zanjan Zanjan Iran
4 shared publicationsHossein Mehraban
University of Semnan
3 shared publications
Latest Publications
- Open Access
- 26 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Assessing gamma-ray shielding effectiveness in alloy europium-modified Zintl-phase
- 26 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessAssessing gamma-ray shielding effectiveness in alloy europium-modified Zintl-phase
- Open Access
- 10 July 2026
- Published by Springer Nature in Journal of Materials Science: Materials in Engineering
- Vol. 21 (1)
Geant4 simulation-based evaluation of gamma and neutron shielding properties of BaTiO₃/CaWO₄-reinforced polymer composites
The demand for lightweight, efficient, and eco-friendly radiation shielding has driven the development of advanced polymer composites. This study evaluates the gamma-ray and neutron attenuation properties of BaTiO₃- and CaWO₄-filled ternary polymer composites (5–20 wt%) using validated Geant4 Monte Carlo simulations (relative discrepancy ≤ 2% vs. experimental benchmarks). Key shielding metrics—linear and mass attenuation coefficients, half- and tenth-value layers, effective atomic number, effective electron density and energy buildup factors—were analyzed over 15 keV–1.5 MeV, complemented by neutron cross-section data at 4.5 MeV. Gamma attenuation improves monotonically with filler content. BaTiO₃ (20%) excels near 60 keV, while CaWO₄ (20%) performs optimally at the W K-edge (69.5 keV). In the photoelectric-dominated range (< 100 keV), CaWO₄ composites reduce HVL by 35–40% relative to BaTiO₃; differences shrink to < 15% in the Compton range (0.2–1 MeV) and vanish above 1 MeV, where HVL exceeds 8 cm for all samples. EBF decreases with higher filler loading, with CaWO₄ showing lower secondary radiation buildup than BaTiO₃. For fast neutrons (4.5 MeV), elastic scattering dominates (28–31%) due to the hydrogen-rich matrix. CaWO₄ (20%) exhibits the lowest transport fraction (69.11%) and shortest mean free path. However, neutron capture probabilities in oxide-doped composites remain negligible (< 0.0015%), highlighting the necessity of hybrid designs incorporating high-capture isotopes (e.g., Gd) for thermal neutron absorption. These results support an energy-specific material selection framework: CaWO₄ (20%) is preferred for low-energy gamma shielding (< 100 keV) and minimal secondary radiation, whereas BaTiO₃ (20%) offers competitive broadband performance. With low density and mechanical flexibility, these composites are suitable for medical radiology, nuclear facility linings, and aerospace applications.
- 10 July 2026
- Published by Springer Nature in Journal of Materials Science: Materials in Engineering
- Vol. 21 (1)
Open AccessGeant4 simulation-based evaluation of gamma and neutron shielding properties of BaTiO₃/CaWO₄-reinforced polymer composites
The demand for lightweight, efficient, and eco-friendly radiation shielding has driven the development of advanced polymer composites. This study evaluates the gamma-ray and neutron attenuation properties of BaTiO₃- and CaWO₄-filled ternary polymer composites (5–20 wt%) using validated Geant4 Monte Carlo simulations (relative discrepancy ≤ 2% vs. experimental benchmarks). Key shielding metrics—linear and mass attenuation coefficients, half- and tenth-value layers, effective atomic number, effective electron density and energy buildup factors—were analyzed over 15 keV–1.5 MeV, complemented by neutron cross-section data at 4.5 MeV. Gamma attenuation improves monotonically with filler content. BaTiO₃ (20%) excels near 60 keV, while CaWO₄ (20%) performs optimally at the W K-edge (69.5 keV). In the photoelectric-dominated range (< 100 keV), CaWO₄ composites reduce HVL by 35–40% relative to BaTiO₃; differences shrink to < 15% in the Compton range (0.2–1 MeV) and vanish above 1 MeV, where HVL exceeds 8 cm for all samples. EBF decreases with higher filler loading, with CaWO₄ showing lower secondary radiation buildup than BaTiO₃. For fast neutrons (4.5 MeV), elastic scattering dominates (28–31%) due to the hydrogen-rich matrix. CaWO₄ (20%) exhibits the lowest transport fraction (69.11%) and shortest mean free path. However, neutron capture probabilities in oxide-doped composites remain negligible (< 0.0015%), highlighting the necessity of hybrid designs incorporating high-capture isotopes (e.g., Gd) for thermal neutron absorption. These results support an energy-specific material selection framework: CaWO₄ (20%) is preferred for low-energy gamma shielding (< 100 keV) and minimal secondary radiation, whereas BaTiO₃ (20%) offers competitive broadband performance. With low density and mechanical flexibility, these composites are suitable for medical radiology, nuclear facility linings, and aerospace applications.
- Open Access
- 25 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Development of a model for design radiation shielding composite aprons using machine learning
This study presents the development and evaluation of a novel lead-free composite for radiation shielding, designed using an artificial neural network (ANN). The ANN model achieved a high predictive accuracy for the mass attenuation coefficient, with a correlation coefficient of R = 0.997 and a mean absolute percentage error of 0.9-1.8%, closely matching benchmark Geant4 Monte Carlo simulations. The optimized Ba-Gd-I-Sb composite (73.9% Ba, 18.2% Gd, 7.65% I) exhibits superior shielding by exploiting synergistic multi-edge absorption. Key quantitative results show that a 1-mm thickness provides > 10⁵ attenuation at 50 keV, > 95% absorption at 1.0 mm thickness, and a favorable weight-to-performance ratio (1.08 kg for a 0.5 mm shield). The composite's attenuation of 99% at 80 keV exceeds that of commercial non-lead alternatives (97-98%), while its transmission matches that of lead at lower energies. These findings demonstrate the composite's high performance and potential as a sustainable, efficient solution for medical and industrial radiation protection.
- 25 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessDevelopment of a model for design radiation shielding composite aprons using machine learning
This study presents the development and evaluation of a novel lead-free composite for radiation shielding, designed using an artificial neural network (ANN). The ANN model achieved a high predictive accuracy for the mass attenuation coefficient, with a correlation coefficient of R = 0.997 and a mean absolute percentage error of 0.9-1.8%, closely matching benchmark Geant4 Monte Carlo simulations. The optimized Ba-Gd-I-Sb composite (73.9% Ba, 18.2% Gd, 7.65% I) exhibits superior shielding by exploiting synergistic multi-edge absorption. Key quantitative results show that a 1-mm thickness provides > 10⁵ attenuation at 50 keV, > 95% absorption at 1.0 mm thickness, and a favorable weight-to-performance ratio (1.08 kg for a 0.5 mm shield). The composite's attenuation of 99% at 80 keV exceeds that of commercial non-lead alternatives (97-98%), while its transmission matches that of lead at lower energies. These findings demonstrate the composite's high performance and potential as a sustainable, efficient solution for medical and industrial radiation protection.
- 22 October 2025
- Published by Springer Nature in Iranian Polymer Journal
- Vol. 35 (5) , 1055-1069
Gamma shielding performance of polyolefin elastomer composites: a theoretical and simulation-based study on bismuth oxide and lead oxide reinforcements
- 22 October 2025
- Published by Springer Nature in Iranian Polymer Journal
- Vol. 35 (5) , 1055-1069
Gamma shielding performance of polyolefin elastomer composites: a theoretical and simulation-based study on bismuth oxide and lead oxide reinforcements
- Open Access
- 12 August 2025
- Published by Lithuanian Academy of Sciences in Lithuanian Journal of Physics
- Vol. 65 (2)
Radiography and radiotherapy of the simulated human tissue environment with high-energy protons: A theoretical study
In this research, the diagnostic imaging and therapy of the environment of selected human tissues by the produced protons from fusion reactions have been simulated by using the Geant4 tool. As a result, the stopping power and range of protons with different energies in these tissues have been obtained. As an example, Bragg peaks caused by protons with energies of 60 to 150 MeV have been shown in breast tissue. Further, the penetration depth of protons, proton flux, and the secondary particle flux of neutrons and gamma with energies of 20 to 70 MeV (in the therapeutic energy range) have been investigated in the breast tissue. Finally, a comparison of the residual dose in breast tissue without a tumour and with a tumour at 60 MeV energy has been done. Therefore, with such simulations, calculations, and creative approaches, effective measures can be taken in the fields of proton imaging and proton therapy because proton radiography is a method that can be used to extract the maximum required information from different human tissues. Also, tumours located in different human tissues can be targeted and destroyed by using different energies of protons.
- 12 August 2025
- Published by Lithuanian Academy of Sciences in Lithuanian Journal of Physics
- Vol. 65 (2)
Open AccessRadiography and radiotherapy of the simulated human tissue environment with high-energy protons: A theoretical study
In this research, the diagnostic imaging and therapy of the environment of selected human tissues by the produced protons from fusion reactions have been simulated by using the Geant4 tool. As a result, the stopping power and range of protons with different energies in these tissues have been obtained. As an example, Bragg peaks caused by protons with energies of 60 to 150 MeV have been shown in breast tissue. Further, the penetration depth of protons, proton flux, and the secondary particle flux of neutrons and gamma with energies of 20 to 70 MeV (in the therapeutic energy range) have been investigated in the breast tissue. Finally, a comparison of the residual dose in breast tissue without a tumour and with a tumour at 60 MeV energy has been done. Therefore, with such simulations, calculations, and creative approaches, effective measures can be taken in the fields of proton imaging and proton therapy because proton radiography is a method that can be used to extract the maximum required information from different human tissues. Also, tumours located in different human tissues can be targeted and destroyed by using different energies of protons.
- 27 July 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (7) , 1-14
Enhancing gamma-ray and neutron shielding properties of borate glasses through the addition of heavy metals oxide
- 27 July 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (7) , 1-14
Enhancing gamma-ray and neutron shielding properties of borate glasses through the addition of heavy metals oxide
- 1 December 2024
- Published by Academic World Research in Journal of Advanced Materials In Engineering
- Vol. 43 (4)
Investigating the Role of Bismuth Oxide and Gadolinium Oxide as an Enhancer of the Gamma Shielding Ability of Polymer Compounds Based on Unsaturated Resin Using the Monte Carlo Simulation Geant4 Tool
- 1 December 2024
- Published by Academic World Research in Journal of Advanced Materials In Engineering
- Vol. 43 (4)
Investigating the Role of Bismuth Oxide and Gadolinium Oxide as an Enhancer of the Gamma Shielding Ability of Polymer Compounds Based on Unsaturated Resin Using the Monte Carlo Simulation Geant4 Tool
- Open Access
- 1 October 2024
- Published by Wolters Kluwer Health in Journal of Medical Physics
- Vol. 49 (4) , 661-672
Monte Carlo Simulation of Gamma and Neutron Shielding with High-performance Ultra-heavy Cement Composite
Purpose: As the applications of nuclear technology increase in today’s world, radiation protection becomes even more important. Radiation protection is important in medical imaging applications and radiotherapy rooms. Therefore, in this research, we have investigated features of the ionizing radiation shielding of the modified cement composite with iron, strontium, zinc, and zirconium elements in the photon energy range of 15 keV to 10 MeV. Materials and Methods: To extract such features, it is necessary to use a computational method. In this research, we have done all our calculations based on the Geant4 tool based on the Monte Carlo method. This tool is a multipurpose tool that can be used for particle transport calculations such as electrons, protons, neutrons, heavy charged particles, and photons in different environments such as human tissues. Results: The mass attenuation coefficient of the samples was calculated using the Geant4 Monte Carlo simulation tool and compared with the results of the Phy-X program, which was in good agreement. To evaluate the radiation shielding capabilities, other quantities such as the linear attenuation coefficient, the thickness of the tenth value layer, the thermal neutron cross-section, absorption rate of thermal neutrons, and the cross-section of the fast neutron removal are determined. Conclusions: According to the quantitative results, cement composite is more effective in absorbing and weakening gamma and neutrons. Calculations of radiation shielding quantities show that cement composites containing tungsten carbide and thallium oxide waste powder are a suitable combination and a practical material for radiation control. In addition, by returning industrial waste to the production sector, they will also be effective in reducing environmental pollution. In general, the cement composite sample containing iron, thallium, zinc, zirconium, tungsten, and carbon elements shows a high potential for radiation protection applications. This study highlights the effective radiation shielding potential of cementitious composites and demonstrates the importance of advancing safety measures in medical and industrial radiation applications.
- 1 October 2024
- Published by Wolters Kluwer Health in Journal of Medical Physics
- Vol. 49 (4) , 661-672
Open AccessMonte Carlo Simulation of Gamma and Neutron Shielding with High-performance Ultra-heavy Cement Composite
Purpose: As the applications of nuclear technology increase in today’s world, radiation protection becomes even more important. Radiation protection is important in medical imaging applications and radiotherapy rooms. Therefore, in this research, we have investigated features of the ionizing radiation shielding of the modified cement composite with iron, strontium, zinc, and zirconium elements in the photon energy range of 15 keV to 10 MeV. Materials and Methods: To extract such features, it is necessary to use a computational method. In this research, we have done all our calculations based on the Geant4 tool based on the Monte Carlo method. This tool is a multipurpose tool that can be used for particle transport calculations such as electrons, protons, neutrons, heavy charged particles, and photons in different environments such as human tissues. Results: The mass attenuation coefficient of the samples was calculated using the Geant4 Monte Carlo simulation tool and compared with the results of the Phy-X program, which was in good agreement. To evaluate the radiation shielding capabilities, other quantities such as the linear attenuation coefficient, the thickness of the tenth value layer, the thermal neutron cross-section, absorption rate of thermal neutrons, and the cross-section of the fast neutron removal are determined. Conclusions: According to the quantitative results, cement composite is more effective in absorbing and weakening gamma and neutrons. Calculations of radiation shielding quantities show that cement composites containing tungsten carbide and thallium oxide waste powder are a suitable combination and a practical material for radiation control. In addition, by returning industrial waste to the production sector, they will also be effective in reducing environmental pollution. In general, the cement composite sample containing iron, thallium, zinc, zirconium, tungsten, and carbon elements shows a high potential for radiation protection applications. This study highlights the effective radiation shielding potential of cementitious composites and demonstrates the importance of advancing safety measures in medical and industrial radiation applications.
- 21 May 2024
- Published by World Scientific Pub Co Pte Ltd in Nano
- Vol. 19 (06)
Nickel/Multiwalled Carbon Nanotube Composites as Gamma-Ray Shielding
In this study, a group of nickel/multi-walled carbon nanotube composites has been investigated in terms of nuclear radiation shielding properties. These nickel-containing nanotubes were considered to achieve valuable results regarding radiation protection, so a detailed investigation was carried out. We have calculated mass attenuation coefficient (MAC), linear attenuation coefficient (LAC), half value layer (HVL), tenth value layer (TVL), mean free path (MFP), equivalent atomic number ([ ], effective atomic number ([ ], effective electron density ([ ], ratio ([ ] and exposure buildup factor (EBF). The obtained results are compared with the values obtained from the XMuDat program, which are in good agreement with each other. We have also analyzed them. Finally, the results obtained for nanotubes are shown in appropriate figures.
- 21 May 2024
- Published by World Scientific Pub Co Pte Ltd in Nano
- Vol. 19 (06)
Nickel/Multiwalled Carbon Nanotube Composites as Gamma-Ray Shielding
In this study, a group of nickel/multi-walled carbon nanotube composites has been investigated in terms of nuclear radiation shielding properties. These nickel-containing nanotubes were considered to achieve valuable results regarding radiation protection, so a detailed investigation was carried out. We have calculated mass attenuation coefficient (MAC), linear attenuation coefficient (LAC), half value layer (HVL), tenth value layer (TVL), mean free path (MFP), equivalent atomic number ([ ], effective atomic number ([ ], effective electron density ([ ], ratio ([ ] and exposure buildup factor (EBF). The obtained results are compared with the values obtained from the XMuDat program, which are in good agreement with each other. We have also analyzed them. Finally, the results obtained for nanotubes are shown in appropriate figures.