Development of a model for design radiation shielding composite aprons using machine learning
Open Access
- 25 May 2026
- journal article
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Abstract
This study presents the development and evaluation of a novel lead-free composite for radiation shielding, designed using an artificial neural network (ANN). The ANN model achieved a high predictive accuracy for the mass attenuation coefficient, with a correlation coefficient of R = 0.997 and a mean absolute percentage error of 0.9-1.8%, closely matching benchmark Geant4 Monte Carlo simulations. The optimized Ba-Gd-I-Sb composite (73.9% Ba, 18.2% Gd, 7.65% I) exhibits superior shielding by exploiting synergistic multi-edge absorption. Key quantitative results show that a 1-mm thickness provides > 10⁵ attenuation at 50 keV, > 95% absorption at 1.0 mm thickness, and a favorable weight-to-performance ratio (1.08 kg for a 0.5 mm shield). The composite's attenuation of 99% at 80 keV exceeds that of commercial non-lead alternatives (97-98%), while its transmission matches that of lead at lower energies. These findings demonstrate the composite's high performance and potential as a sustainable, efficient solution for medical and industrial radiation protection.Keywords
This publication has 45 references indexed in Scilit:
- Enhancing predictive accuracy of nano-additive concrete gamma ray attenuation at high temperatures using AI-based modelsNeural Computing and Applications, 2025
- Multi-nanoparticle-based composite for diagnostic X-ray shielding in computed tomography applications: a Monte Carlo studyRadiation and Environmental Biophysics, 2025
- The Role of Ytterbium (Yb2O3) in the Radiation Shielding Properties of Barium Titanium Borate Glasses (B2O3-TiO2-BaO) in Terms of γ and β RadiationsJournal of Electronic Materials, 2024
- A Comprehensive Investigation of the Impact of NiO on the Radiation Attenuation Characteristics of (CaO-Li2O-NiO-SiO2) Glass StructureJournal of Electronic Materials, 2023
- Impact of four kVp combinations available in a dual‐source CT on the spectral performance of abdominal imaging: A task‐based image quality assessment on phantom dataJournal of Applied Clinical Medical Physics, 2021
- Keras and TensorFlow: A Hands-On Experience2021
- Get Protected! Recommendations for Staff in IRCardioVascular and Interventional Radiology, 2021
- Trends in reinforced composite design for ionizing radiation shielding applications: a reviewJournal of Materials Science, 2021
- Hebbian Learning Rule2019
- Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVpPediatric Radiology, 2017