Tatsuji Yamada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tatsuji Yamada has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Seitaro Kon
National Institute of Advanced Industrial Science and Technology
11 shared publications Saytaro Kon
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
7 shared publications- Norihiko Sakamoto
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
4 shared publications H. Okubo
Nagoya University
3 shared publicationsN. Hayakawa
Nagoya University
3 shared publications- Katsuya Tachibana
Yokogawa Electric Corporation, Kofu, Japan
2 shared publications
Latest Publications
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-7
A Flexible Evaluation System for the Complex Calibration of Inductive and Resistive Voltage Dividers up to 100 kHz
Toward calibration of wideband resistive voltage dividers (WRVDs), a new evaluation system has been developed, and its validation has been made by employing standard inductive voltage dividers (IVDs) calibrated by Thompson’s method. The evaluation system, designed within 120-V and 100-kHz ranges, introduced a wideband phase standard as a two-phase signal generator, allowing the phase errors of the phase meters in the system to be measured preliminarily. An error correction for the digital lock-in amplifier has also been applied. Those corrections attained a great evaluation performance. Furthermore, the uncertainty of the evaluation system has been estimated by considering some correlations between the uncertainty contributions factors.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-7
A Flexible Evaluation System for the Complex Calibration of Inductive and Resistive Voltage Dividers up to 100 kHz
Toward calibration of wideband resistive voltage dividers (WRVDs), a new evaluation system has been developed, and its validation has been made by employing standard inductive voltage dividers (IVDs) calibrated by Thompson’s method. The evaluation system, designed within 120-V and 100-kHz ranges, introduced a wideband phase standard as a two-phase signal generator, allowing the phase errors of the phase meters in the system to be measured preliminarily. An error correction for the digital lock-in amplifier has also been applied. Those corrections attained a great evaluation performance. Furthermore, the uncertainty of the evaluation system has been estimated by considering some correlations between the uncertainty contributions factors.
- 17 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-6
Multiusing a TVC Toward Development of TVM-Based Phase Measurement System up to 1 MHz
We had previously proposed a wideband phase measurement system based on the three-voltmeter method by using a normal thermal voltage converter (TVC) for measuring the differential AC voltage between two AC voltage signals. Several problems were recorded in our previous system, especially for operations in the wideband frequency range. We have investigated their causes and proposed a few solutions. To overcome these problems, we have proposed an additive calibration for the voltmeters by switching the TVC from the differential input mode into a reversible single-ended input mode. The large error peak problem at higher frequencies has been addressed. We compared our proposed system to the new commercial phase standards up to 1 MHz and confirmed the effectiveness of the additive calibration by using the TVC for multiple purposes.
- 17 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-6
Multiusing a TVC Toward Development of TVM-Based Phase Measurement System up to 1 MHz
We had previously proposed a wideband phase measurement system based on the three-voltmeter method by using a normal thermal voltage converter (TVC) for measuring the differential AC voltage between two AC voltage signals. Several problems were recorded in our previous system, especially for operations in the wideband frequency range. We have investigated their causes and proposed a few solutions. To overcome these problems, we have proposed an additive calibration for the voltmeters by switching the TVC from the differential input mode into a reversible single-ended input mode. The large error peak problem at higher frequencies has been addressed. We compared our proposed system to the new commercial phase standards up to 1 MHz and confirmed the effectiveness of the additive calibration by using the TVC for multiple purposes.
- 3 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-7
Design Method for a Wideband Resistive Voltage Divider Based on Average Impedance Matching With Optimal Solution Methods
This paper proposes a design method for wideband resistive voltage dividers (WRVDs), working in the range of power frequencies to a few MHz, with serial-parallel construction. It introduces an extended concept of the Hamon method into the WRVDs, not in a conventional way like balancing a bridge, but in a new way that involves impedance matching with optimal solution methods. With this method, average resistance matching and stray capacitance matching are simultaneously realized by an optimal arrangement of two element resistor groups as the input and output resistors. The surrounding stray capacitances between the resistors and chassis are also considered. The performance has been confirmed to improve by about 50 times, compared to that without the method.
- 3 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-7
Design Method for a Wideband Resistive Voltage Divider Based on Average Impedance Matching With Optimal Solution Methods
This paper proposes a design method for wideband resistive voltage dividers (WRVDs), working in the range of power frequencies to a few MHz, with serial-parallel construction. It introduces an extended concept of the Hamon method into the WRVDs, not in a conventional way like balancing a bridge, but in a new way that involves impedance matching with optimal solution methods. With this method, average resistance matching and stray capacitance matching are simultaneously realized by an optimal arrangement of two element resistor groups as the input and output resistors. The surrounding stray capacitances between the resistors and chassis are also considered. The performance has been confirmed to improve by about 50 times, compared to that without the method.
- 27 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (6) , 2021-2026
A New Phase Difference Measurement System With Differential AC/Single-Ended DC Switching for One TVC
This paper describes a new phase difference measurement system based on the three-voltmeter method (3VM) by introducing differential AC/single-ended DC switching for a thermal voltage converter (TVC). The 3VM-based phase difference measurement system has been developed in consideration of the simulation results and the loading effects derived from the TVC. The expanded uncertainties of differential voltage and phase difference measurements have been estimated (e.g. 80 μV and 0.0073° at 10 V / 1V, 1 kHz and 60°). The phase difference measurement uncertainties of two voltage conditions (V1 > V2 and V1 = V2) have been focused and theoretically formulated. The phase difference measurements by the system have been made in the voltage range of 1 V to 10 V at 1 kHz and 60°. The measurement results agree well with those obtained by a phase standard.
- 27 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (6) , 2021-2026
A New Phase Difference Measurement System With Differential AC/Single-Ended DC Switching for One TVC
This paper describes a new phase difference measurement system based on the three-voltmeter method (3VM) by introducing differential AC/single-ended DC switching for a thermal voltage converter (TVC). The 3VM-based phase difference measurement system has been developed in consideration of the simulation results and the loading effects derived from the TVC. The expanded uncertainties of differential voltage and phase difference measurements have been estimated (e.g. 80 μV and 0.0073° at 10 V / 1V, 1 kHz and 60°). The phase difference measurement uncertainties of two voltage conditions (V1 > V2 and V1 = V2) have been focused and theoretically formulated. The phase difference measurements by the system have been made in the voltage range of 1 V to 10 V at 1 kHz and 60°. The measurement results agree well with those obtained by a phase standard.
- 13 April 2017
- Published by Wiley in Electronics and Communications in Japan
- Vol. 100 (5) , 26-33
Error Analysis of Improved Current-Bridge Method for Accurate Low-Impedance Measurement
- 13 April 2017
- Published by Wiley in Electronics and Communications in Japan
- Vol. 100 (5) , 26-33
Error Analysis of Improved Current-Bridge Method for Accurate Low-Impedance Measurement
- 7 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 66 (6) , 1524-1530
Evaluation of Atypical-Ratio Wideband Voltage Dividers With Consideration for Impedance Mismatches
This paper proposes a novel method that uses two phase-locked signal generators to evaluate wideband voltage dividers that have wide voltage ratio ranges, including atypical ratios like 1/101. These voltage dividers are intended to be fabricated by applying the Hamon principle. Verification of the proposed method was carried out using standard inductive voltage dividers calibrated using Thompson's method. In this paper, we also consider impedance mismatch effects on the phase measurements taken during the evaluation.
- 7 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 66 (6) , 1524-1530
Evaluation of Atypical-Ratio Wideband Voltage Dividers With Consideration for Impedance Mismatches
This paper proposes a novel method that uses two phase-locked signal generators to evaluate wideband voltage dividers that have wide voltage ratio ranges, including atypical ratios like 1/101. These voltage dividers are intended to be fabricated by applying the Hamon principle. Verification of the proposed method was carried out using standard inductive voltage dividers calibrated using Thompson's method. In this paper, we also consider impedance mismatch effects on the phase measurements taken during the evaluation.
- 6 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 66 (6) , 1254-1259
Expansion of the Impedance and Frequency Measurement Ranges of AC Shunt Resistors
For expanding the impedance and frequency ranges of a calibration system for ac shunt resistors, a current bridge method with cascaded current transformers (CTs) has been developed. An ac shunt resistor with a nominal value of 10 mΩ is evaluated by the current bridge method using cascaded CTs and the results of the calibration system using this method are validated. It is demonstrated that the calibration system for ac shunt resistors using the current-bridge method with the cascaded CTs can be used successfully for both in-phase and quadrature components up to 3 kHz. Further, for expanding the frequency range, a voltage difference method is proposed. The measurement results obtained by the current-bridge method and the proposed method are consistent with each other within the measurement uncertainties. In addition, for expanding the impedance range at higher frequencies, a combination method with an inductive voltage divider and a current transformer is proposed. The measurement results using the combination method are consistent with the results of the current-bridge method within the measurement uncertainties. The test current in this paper was limited up to 10 A because of the specification of shunt resistors.
- 6 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 66 (6) , 1254-1259
Expansion of the Impedance and Frequency Measurement Ranges of AC Shunt Resistors
For expanding the impedance and frequency ranges of a calibration system for ac shunt resistors, a current bridge method with cascaded current transformers (CTs) has been developed. An ac shunt resistor with a nominal value of 10 mΩ is evaluated by the current bridge method using cascaded CTs and the results of the calibration system using this method are validated. It is demonstrated that the calibration system for ac shunt resistors using the current-bridge method with the cascaded CTs can be used successfully for both in-phase and quadrature components up to 3 kHz. Further, for expanding the frequency range, a voltage difference method is proposed. The measurement results obtained by the current-bridge method and the proposed method are consistent with each other within the measurement uncertainties. In addition, for expanding the impedance range at higher frequencies, a combination method with an inductive voltage divider and a current transformer is proposed. The measurement results using the combination method are consistent with the results of the current-bridge method within the measurement uncertainties. The test current in this paper was limited up to 10 A because of the specification of shunt resistors.
- 11 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
An evaluation method for wideband voltage dividers using two phase-locked signal generators
This paper describes a proposed evaluation method of a wideband voltage divider of wide voltage and ratio ranges. An evaluation system developed to realize the proposed method is introduced. To ensure the validity of the system, the results by the proposed method have been compared with those by a conventional method using standard IVDs. A large departure between them is observed as higher frequencies around 100 kHz.
- 11 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
An evaluation method for wideband voltage dividers using two phase-locked signal generators
This paper describes a proposed evaluation method of a wideband voltage divider of wide voltage and ratio ranges. An evaluation system developed to realize the proposed method is introduced. To ensure the validity of the system, the results by the proposed method have been compared with those by a conventional method using standard IVDs. A large departure between them is observed as higher frequencies around 100 kHz.
- 11 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Expansion of the measurement range of AC shunt resistor standard
There has been a demand for accurate measurements of ac shunt resistors with a nominal value of 1 mS or less for both in-phase and quadrature components. Thus, to expand the ranges of impedance and frequency of the calibration system for ac shunt resistors, a current bridge method with cascaded current transformers (CTs) has been developed. An ac shunt resistor with nominal value of 10 mS was evaluated by a current bridge method using cascaded CTs, and the results of the calibration system using this method were validated. It was found that the calibration system for ac shunt resistors using the current-bridge method with cascaded CTs can be used successfully for both in-phase and quadrature components up to 3 kHz.
- 11 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Expansion of the measurement range of AC shunt resistor standard
There has been a demand for accurate measurements of ac shunt resistors with a nominal value of 1 mS or less for both in-phase and quadrature components. Thus, to expand the ranges of impedance and frequency of the calibration system for ac shunt resistors, a current bridge method with cascaded current transformers (CTs) has been developed. An ac shunt resistor with nominal value of 10 mS was evaluated by a current bridge method using cascaded CTs, and the results of the calibration system using this method were validated. It was found that the calibration system for ac shunt resistors using the current-bridge method with cascaded CTs can be used successfully for both in-phase and quadrature components up to 3 kHz.
- 19 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 64 (6) , 1546-1552
Error and Uncertainty Estimations for A Passive-CC-Based AC Current Ratio Standard at High Audio Frequencies
This paper describes a development framework for alternating current ratio standard working at high audio frequencies. To realize this, first, a calibration method for frequency-dependent balancing current generators (BCGs) producing error currents to balance current comparators (CCs) is proposed. Second, the BCG error correction is made not only for the current transformer (CT) calibration but also for the CC self-calibration. Third, practical capacitive error corrections are also proposed to be introduced for the CT and CC calibrations. Finally, in consideration of the BCG error, capacitive error, and compensated CC error, a proposed way of calculating CT error and estimating its uncertainty is described.
- 19 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 64 (6) , 1546-1552
Error and Uncertainty Estimations for A Passive-CC-Based AC Current Ratio Standard at High Audio Frequencies
This paper describes a development framework for alternating current ratio standard working at high audio frequencies. To realize this, first, a calibration method for frequency-dependent balancing current generators (BCGs) producing error currents to balance current comparators (CCs) is proposed. Second, the BCG error correction is made not only for the current transformer (CT) calibration but also for the CC self-calibration. Third, practical capacitive error corrections are also proposed to be introduced for the CT and CC calibrations. Finally, in consideration of the BCG error, capacitive error, and compensated CC error, a proposed way of calculating CT error and estimating its uncertainty is described.