E. S. Martazov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
E. S. Martazov has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
N. A. Selyaev
National Research Nuclear University MEPhI, Kashirskoe 31, Moscow, Russia
3 shared publications- V. A. Fedorov
National Research Nuclear University MEPhI, Kashirskoe 31, Moscow, Russia
3 shared publications V. A. Vorobiev
Institution “Project Center ITER”, Kurchatov 1-3, Moscow, Russia
3 shared publications- Yuri A. Kashchuk
Institution Project Center ITER, Moscow, Russia
3 shared publications Yu. A. Parishkin
National Research Nuclear University MEPhI, Kashirskoe 31, Moscow, Russia
2 shared publicationsA. V. Batyunin
Institution Project Center ITER, Moscow, Russia
1 shared publication
Latest Publications
- 24 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (4) , 688-693
Study of the Data Acquisition System for ITER Divertor Neutron Flux Monitor Diagnostic
Diagnostic "Divertor Neutron Flux Monitor" is one of the diagnostics to determine the neutron yield and the thermonuclear power of the ITER facility. To detect neutrons this diagnostic uses three detector modules. The expected neutron flux in the detector modules location is 10 6 to 10 13 n·cm-27s -1. The neuron flux and the neutron yield should be measured with 1 ms time resolution and 10 % maximum relative error. The detector module consisting of six fission chambers is used to meet these requirements and each fission chamber signal is processed by pulse-counting, Campbell and current measurement methods simultaneously. According to the data of the each measurement method the normalized count rates of the fission chambers and the detector module and the neutron flux at its location are calculated. The data acquisition system processes the signals of the single detector module and transmits data of the normalized count rate and the neutron flux of each detector and the entire detector module to the upper level system. To verify the techniques solutions the data acquisition system prototype was manufactured. To study the characteristics of this prototype a set of laboratory tests were carried out. This paper illustrates the structure of the data acquisition system and the implementation of the fission chamber signals processing methods. The results of the study of the data acquisition system prototype for single detector module are given.
- 24 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (4) , 688-693
Study of the Data Acquisition System for ITER Divertor Neutron Flux Monitor Diagnostic
Diagnostic "Divertor Neutron Flux Monitor" is one of the diagnostics to determine the neutron yield and the thermonuclear power of the ITER facility. To detect neutrons this diagnostic uses three detector modules. The expected neutron flux in the detector modules location is 10 6 to 10 13 n·cm-27s -1. The neuron flux and the neutron yield should be measured with 1 ms time resolution and 10 % maximum relative error. The detector module consisting of six fission chambers is used to meet these requirements and each fission chamber signal is processed by pulse-counting, Campbell and current measurement methods simultaneously. According to the data of the each measurement method the normalized count rates of the fission chambers and the detector module and the neutron flux at its location are calculated. The data acquisition system processes the signals of the single detector module and transmits data of the normalized count rate and the neutron flux of each detector and the entire detector module to the upper level system. To verify the techniques solutions the data acquisition system prototype was manufactured. To study the characteristics of this prototype a set of laboratory tests were carried out. This paper illustrates the structure of the data acquisition system and the implementation of the fission chamber signals processing methods. The results of the study of the data acquisition system prototype for single detector module are given.
- 31 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2421-2425
Fission Chambers Detector Unit Mockup Testing at Research Reactors
This paper presents the results of the fission chambers (FC) behavior under intensive neutron and gamma radiation at the research reactors. The FC detector unit (DU) was designed for the International Experimental Thermonuclear Reactor neutron diagnostic “divertor neutron flux monitor.” Two mockups of the DU with FCs containing 1 g and 100 mg of 235 U were tested. The test complex is based on the FC signal processing unit and the FC parameters' monitoring system. The processing unit contains several measuring chains and acquire FC signal over a wide range of neutron flux variation. The FC parameters' monitoring system records signal shapes, acquires pulse-height amplitude spectra, and checks electrical parameters of the neutron detector. The radiation tests were carried out at the research reactors IRT MEPhI and VVR-c. The structure and characteristics of the test complex as well measurement techniques and tools for FC characterization are discussed. The results of reactor experiments to determine characteristics of the DU mockup and wide-range neutron flux monitoring channels are presented.
- 31 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2421-2425
Fission Chambers Detector Unit Mockup Testing at Research Reactors
This paper presents the results of the fission chambers (FC) behavior under intensive neutron and gamma radiation at the research reactors. The FC detector unit (DU) was designed for the International Experimental Thermonuclear Reactor neutron diagnostic “divertor neutron flux monitor.” Two mockups of the DU with FCs containing 1 g and 100 mg of 235 U were tested. The test complex is based on the FC signal processing unit and the FC parameters' monitoring system. The processing unit contains several measuring chains and acquire FC signal over a wide range of neutron flux variation. The FC parameters' monitoring system records signal shapes, acquires pulse-height amplitude spectra, and checks electrical parameters of the neutron detector. The radiation tests were carried out at the research reactors IRT MEPhI and VVR-c. The structure and characteristics of the test complex as well measurement techniques and tools for FC characterization are discussed. The results of reactor experiments to determine characteristics of the DU mockup and wide-range neutron flux monitoring channels are presented.
- 16 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2392-2397
Data Acquisition System for ITER Neutron Diagnostic Divertor Neutron Flux Monitor
Neutron diagnostic "Divertor Neutron Flux Monitor" is being under development for the ITER project. This diagnostic is a primary tool for total neutron yield and fusion power measurements. Diagnostic consists of the three detector modules and the enhanced data acquisition systems. Each module contains three fission chambers with 235U and three with 238U. The choice of the fission chambers types and sensitivities is determined by the project requirements for the neutron flux measurement range, error and time resolution. The data acquisition system performs preliminary amplification and processing of the fission chamber signals, calculation of the neutron flux at the module location to calculate the total neutron yield and fusion power. The data acquisition system transfers measured data to the upper-level of the control system with a time resolution of 1 ms and provides raw data archiving. The hardware and software of the data acquisition system was developed taking into account the requirements of the ITER project. The data processing system mockup of a single detection module was manufactured. This mockup passed laboratory and reactor tests. The system has passed the preliminary design approval. Preparation for the manufacturing of the system prototype is carried out at this moment. The architecture of the data acquisition system and its components are shown in the report and the test results of the system mockup are discussed.
- 16 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2392-2397
Data Acquisition System for ITER Neutron Diagnostic Divertor Neutron Flux Monitor
Neutron diagnostic "Divertor Neutron Flux Monitor" is being under development for the ITER project. This diagnostic is a primary tool for total neutron yield and fusion power measurements. Diagnostic consists of the three detector modules and the enhanced data acquisition systems. Each module contains three fission chambers with 235U and three with 238U. The choice of the fission chambers types and sensitivities is determined by the project requirements for the neutron flux measurement range, error and time resolution. The data acquisition system performs preliminary amplification and processing of the fission chamber signals, calculation of the neutron flux at the module location to calculate the total neutron yield and fusion power. The data acquisition system transfers measured data to the upper-level of the control system with a time resolution of 1 ms and provides raw data archiving. The hardware and software of the data acquisition system was developed taking into account the requirements of the ITER project. The data processing system mockup of a single detection module was manufactured. This mockup passed laboratory and reactor tests. The system has passed the preliminary design approval. Preparation for the manufacturing of the system prototype is carried out at this moment. The architecture of the data acquisition system and its components are shown in the report and the test results of the system mockup are discussed.