Yuri A. Kashchuk
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuri A. Kashchuk has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Dmitri V. Portnov
Institution Project Center ITER, Moscow, Russia
4 shared publications N. A. Selyaev
National Research Nuclear University MEPhI, Kashirskoe 31, Moscow, Russia
4 shared publications- Timofey Kormilitsyn
Institution Project Center ITER, Moscow, Russia
4 shared publications V. A. Vorobiev
Institution “Project Center ITER”, Kurchatov 1-3, Moscow, Russia
4 shared publicationsA. V. Batyunin
Institution Project Center ITER, Moscow, Russia
3 shared publications- E. S. Martazov
National Research Nuclear University MEPhI, Kashirskoe 31, Moscow, Russia
3 shared publications
Latest Publications
- Open Access
- 19 June 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (8) , 086049
Features of fusion power measurements in the next generation magnetic plasma confinement experiments
Fusion power measurements provide one of the key benchmarks for every successful reactor-scale magnetic confinement fusion facility. Neutrons carry outside of the plasma volume 4/5 of the produced fusion power in case of deuterium-tritium fuel mix. Thus, measurement of 14-MeV neutron yield is the primary direct measurement of the fusion power of the machine. The challenge of determining the uncertainty of the total neutron yield measurement is solved using several strategies: detailed detector assessment in the metrological neutron laboratory, in-situ calibration using a mobile neutron source (typically - 252Cf) and cross-calibration using a well characterized detector in well-known discharge. Transition to reactor-scale devices such as BEST, ITER, DEMO, etc. will require the use of neutron sources with yields of 1e10-1e11 s-1 and above. Multiple diagnostics systems fall in the scope - neutron counters, neutron activation system and multi-collimator systems. Together they provide fusion power measurement with up to 10% accuracy and 1 ms time resolution for the case of ITER, in a broad dynamic range of fusion power. Two methods for in situ calibration are considered: 1) utilizing multiple NG positions to emulate circular or ‘ring’ source of fusion neutrons for calibration of the permanent detector set, and 2) making use of multiple temporary detectors located in numerous locations inside the vacuum vessel for the period of the calibration, thus allowing to obtain more reference points for further Monte-Carlo model validation with the same (or less) irradiation duration. The work details results of neutron detector characterization activity in laboratory conditions with the use of compact NGs, showing that the use of powerful (up to 1e11 s-1 D-T, 1e9 s-1 D-D) yet compact NGs with sealed tubes raises a challenge of a steady source metrological assurance, especially when considering said sources for the task of in-situ calibration.
- 19 June 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (8) , 086049
Open AccessFeatures of fusion power measurements in the next generation magnetic plasma confinement experiments
Fusion power measurements provide one of the key benchmarks for every successful reactor-scale magnetic confinement fusion facility. Neutrons carry outside of the plasma volume 4/5 of the produced fusion power in case of deuterium-tritium fuel mix. Thus, measurement of 14-MeV neutron yield is the primary direct measurement of the fusion power of the machine. The challenge of determining the uncertainty of the total neutron yield measurement is solved using several strategies: detailed detector assessment in the metrological neutron laboratory, in-situ calibration using a mobile neutron source (typically - 252Cf) and cross-calibration using a well characterized detector in well-known discharge. Transition to reactor-scale devices such as BEST, ITER, DEMO, etc. will require the use of neutron sources with yields of 1e10-1e11 s-1 and above. Multiple diagnostics systems fall in the scope - neutron counters, neutron activation system and multi-collimator systems. Together they provide fusion power measurement with up to 10% accuracy and 1 ms time resolution for the case of ITER, in a broad dynamic range of fusion power. Two methods for in situ calibration are considered: 1) utilizing multiple NG positions to emulate circular or ‘ring’ source of fusion neutrons for calibration of the permanent detector set, and 2) making use of multiple temporary detectors located in numerous locations inside the vacuum vessel for the period of the calibration, thus allowing to obtain more reference points for further Monte-Carlo model validation with the same (or less) irradiation duration. The work details results of neutron detector characterization activity in laboratory conditions with the use of compact NGs, showing that the use of powerful (up to 1e11 s-1 D-T, 1e9 s-1 D-D) yet compact NGs with sealed tubes raises a challenge of a steady source metrological assurance, especially when considering said sources for the task of in-situ calibration.
- 1 December 2025
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 88 (7) , 1302-1310
Analysis of Radiation Conditions on a Tokamak with Reactor Technologies
The tokamak with reactor technologies (TRT) is intended for experiments with powerful auxiliary heating of deuterium plasma (up to 40 MW) during a long pulse (100 s) with a neutron output of 1017 neutrons/s. Analysis of the radiation environment arising during the execution of the experimental program on the thermonuclear facility is required at an early stage of tokamak design to make engineering decisions that ensure safe operation of the facility, taking into account all radiation-related aspects such as possible heating of the superconducting magnet system, levels of radiation damage and neutron shielding, activation of structural materials, dose rates, and the safety of maintenance personnel. This paper presents results of simulation of the transport of neutron and gamma (photon) radiation for the experiments planned on the TRT. Spatial distributions of neutron and photon radiation fields are determined, and neutron fluxes and spectra are calculated in key structures and components of the tokamak—the vacuum vessel, HTS cables, toroidal field coils, and elements of diagnostic systems. An assessment of activation of the vacuum vessel is performed and the time evolution of dose-rate decay is shown.
- 1 December 2025
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 88 (7) , 1302-1310
Analysis of Radiation Conditions on a Tokamak with Reactor Technologies
The tokamak with reactor technologies (TRT) is intended for experiments with powerful auxiliary heating of deuterium plasma (up to 40 MW) during a long pulse (100 s) with a neutron output of 1017 neutrons/s. Analysis of the radiation environment arising during the execution of the experimental program on the thermonuclear facility is required at an early stage of tokamak design to make engineering decisions that ensure safe operation of the facility, taking into account all radiation-related aspects such as possible heating of the superconducting magnet system, levels of radiation damage and neutron shielding, activation of structural materials, dose rates, and the safety of maintenance personnel. This paper presents results of simulation of the transport of neutron and gamma (photon) radiation for the experiments planned on the TRT. Spatial distributions of neutron and photon radiation fields are determined, and neutron fluxes and spectra are calculated in key structures and components of the tokamak—the vacuum vessel, HTS cables, toroidal field coils, and elements of diagnostic systems. An assessment of activation of the vacuum vessel is performed and the time evolution of dose-rate decay is shown.
- 17 April 2025
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 82 (4) , 805-813
Synchronization of the OpenMC and MCNP Models for ITER Neutronics
- 17 April 2025
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 82 (4) , 805-813
Synchronization of the OpenMC and MCNP Models for ITER Neutronics
- 1 December 2023
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 86 (S2) , S218-S224
On the Feasibility of Calibrating the Fluctuation Channel for Neutron Diagnostics of Plasma
A relatively simple option of calibrating a fluctuation measurement channel by processing a series of pulses from ionization fission chambers obtained using a low-intensity neutron source is substantiated. The fluctuation channel for measuring the pulse counting rate is an integral part of the ITER Divertor Neutron Flux Monitor, a neutron diagnostics measurement system. The fluctuation measurement method is widely used in control systems for nuclear reactors and has also been repeatedly applied in measuring neutron fluxes at fusion installations with a large neutron yield, TFTR, JET, and JT-60U. The method is based on measuring the dispersion of the signal generated at the output of the signal amplifier of ionization fission chambers. The theoretical basis of the method is Campbell’s second theorem. Regarding the application of the theorem to ionization fission chambers, the signal dispersion is proportional to the repetition rate (counting rate) of the neutron detector pulses, which, in turn, is proportional to the neutron flux. The method is also referred as MSV, which is an abbreviation for mean square value. Calibration of the fluctuation channel consists in determining the proportionality coefficient, which relates the actually measured signal dispersion of the ionization fission chamber and the desired value of the pulse counting rate. The proportionality coefficient depends both on the characteristics of the detector (amplitude distribution of current pulses, collection time, electrical capacitance) and on the parameters of the fluctuation channel measurement system (bandwidth, quality of cable communication lines, amplifiers, filters, etc.). Under the conditions of a real physical experiment, calibration requires an analytical and experimental study of two components of neutron detector signals: the distribution of squared pulse amplitudes to determine the mean square of the amplitude and the type of function describing the “averaged” shape of the signals. The correctness of calculations and estimates is verified using the output values of the reference measurement channel (usually this is a channel for measuring the pulse counting rate). To implement calibration, measurements using intense sources of neutron radiation should be carried out. The feasibility of calibrating a fluctuation measurement channel by recording and processing a series of fission chamber signals from a low-intensity neutron source is substantiated. Analytical expressions are derived for calculating the calibration coefficient of the fluctuation measurement channel. An experimental verification of the method was carried out in measurements of the neutron flux from a neutron generator with an output of 1011 neutron/s. The possibility of calibrating the fluctuation measurement channel of neutron plasma diagnostics at the ITER site using low-intensity neutron sources is discussed.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 86 (S2) , S218-S224
On the Feasibility of Calibrating the Fluctuation Channel for Neutron Diagnostics of Plasma
A relatively simple option of calibrating a fluctuation measurement channel by processing a series of pulses from ionization fission chambers obtained using a low-intensity neutron source is substantiated. The fluctuation channel for measuring the pulse counting rate is an integral part of the ITER Divertor Neutron Flux Monitor, a neutron diagnostics measurement system. The fluctuation measurement method is widely used in control systems for nuclear reactors and has also been repeatedly applied in measuring neutron fluxes at fusion installations with a large neutron yield, TFTR, JET, and JT-60U. The method is based on measuring the dispersion of the signal generated at the output of the signal amplifier of ionization fission chambers. The theoretical basis of the method is Campbell’s second theorem. Regarding the application of the theorem to ionization fission chambers, the signal dispersion is proportional to the repetition rate (counting rate) of the neutron detector pulses, which, in turn, is proportional to the neutron flux. The method is also referred as MSV, which is an abbreviation for mean square value. Calibration of the fluctuation channel consists in determining the proportionality coefficient, which relates the actually measured signal dispersion of the ionization fission chamber and the desired value of the pulse counting rate. The proportionality coefficient depends both on the characteristics of the detector (amplitude distribution of current pulses, collection time, electrical capacitance) and on the parameters of the fluctuation channel measurement system (bandwidth, quality of cable communication lines, amplifiers, filters, etc.). Under the conditions of a real physical experiment, calibration requires an analytical and experimental study of two components of neutron detector signals: the distribution of squared pulse amplitudes to determine the mean square of the amplitude and the type of function describing the “averaged” shape of the signals. The correctness of calculations and estimates is verified using the output values of the reference measurement channel (usually this is a channel for measuring the pulse counting rate). To implement calibration, measurements using intense sources of neutron radiation should be carried out. The feasibility of calibrating a fluctuation measurement channel by recording and processing a series of fission chamber signals from a low-intensity neutron source is substantiated. Analytical expressions are derived for calculating the calibration coefficient of the fluctuation measurement channel. An experimental verification of the method was carried out in measurements of the neutron flux from a neutron generator with an output of 1011 neutron/s. The possibility of calibrating the fluctuation measurement channel of neutron plasma diagnostics at the ITER site using low-intensity neutron sources is discussed.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 86 (S2) , S187-S197
Measurements of ITER Fusion Power by Neutron Flux Monitors
The results of the analysis of the uncertainty in measurements of fusion power of the DD and DT plasma scenarios of the ITER tokamak reactor by means of neutron flux monitors are presented. The measurement by three ITER neutron flux monitor systems–Divertor Neutron Flux Monitor (DNFM), Neutron Flux Monitor (NFM), and Micro-Fission Chamber (MFC)–has been simulated. The diagnostic systems considered are designed to measure the total neutron flux and fusion power of ITER plasma. The sources and magnitude of uncertainty in measurements of fusion power and the total neutron flux for various ITER plasma scenarios are examined. The magnitude of the required error in the calibration of the diagnostic detectors is estimated. On the basis of the results of the neutronic analysis and the requirements for the diagnostics set by the International Organization ITER, the expected performance characteristics of diagnostic systems are confirmed. A method to compensate the systematic measurement error of the DNFM due to the vertical displacement of the plasma is proposed.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 86 (S2) , S187-S197
Measurements of ITER Fusion Power by Neutron Flux Monitors
The results of the analysis of the uncertainty in measurements of fusion power of the DD and DT plasma scenarios of the ITER tokamak reactor by means of neutron flux monitors are presented. The measurement by three ITER neutron flux monitor systems–Divertor Neutron Flux Monitor (DNFM), Neutron Flux Monitor (NFM), and Micro-Fission Chamber (MFC)–has been simulated. The diagnostic systems considered are designed to measure the total neutron flux and fusion power of ITER plasma. The sources and magnitude of uncertainty in measurements of fusion power and the total neutron flux for various ITER plasma scenarios are examined. The magnitude of the required error in the calibration of the diagnostic detectors is estimated. On the basis of the results of the neutronic analysis and the requirements for the diagnostics set by the International Organization ITER, the expected performance characteristics of diagnostic systems are confirmed. A method to compensate the systematic measurement error of the DNFM due to the vertical displacement of the plasma is proposed.
- 1 December 2022
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 48 (12) , 1339-1344
Requirements for the Measurements of Plasma Characteristics at the Tokamak with Reactor Technologies (TRT)
A list of requirements for the measurements of characteristics of high-temperature plasma that ensure safe operation and protection of the tokamak with reactor technologies, along with control of the plasma column and investigation into fusion-plasma physics, is formulated. Special attention is paid to measurements the results of which are needed for the development of plasma technologies of future quasi-stationary fusion reactors. Plasma parameter ranges, including the requirement for the resolution with which these parameters must be measurement, are defined. These requirements represent the initial data for choosing the systems of measurements, development of construction, and subsequent integration of diagnostics in the system. Classification of diagnostics depending on the problems to be solved and the stages of diagnostic complex development of the tokamak with reactor technologies is proposed.
- 1 December 2022
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 48 (12) , 1339-1344
Requirements for the Measurements of Plasma Characteristics at the Tokamak with Reactor Technologies (TRT)
A list of requirements for the measurements of characteristics of high-temperature plasma that ensure safe operation and protection of the tokamak with reactor technologies, along with control of the plasma column and investigation into fusion-plasma physics, is formulated. Special attention is paid to measurements the results of which are needed for the development of plasma technologies of future quasi-stationary fusion reactors. Plasma parameter ranges, including the requirement for the resolution with which these parameters must be measurement, are defined. These requirements represent the initial data for choosing the systems of measurements, development of construction, and subsequent integration of diagnostics in the system. Classification of diagnostics depending on the problems to be solved and the stages of diagnostic complex development of the tokamak with reactor technologies is proposed.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043528
Novel LaCl3(Ce)-based spectrometer for deuterium plasma neutron diagnostics
This work studies in detail the application possibility of a chlorine-based cerium-doped scintillator crystal [LaCl3(Ce)] to the task of D–D neutron spectrometry. We conducted an experimental campaign aimed at deriving the optimal setup parameters and energy calibration using a variety of available neutrons and γ-sources. The GEANT4 code was used for modeling the detector response to γ-ray irradiation. By observing the intrinsic background α-activity of the crystal, we were able to fine-tune the pulse-shape discrimination parameters, achieving a satisfactory α/n/γ pulse selection. We also investigated the LaCl3(Ce)-based spectrometer response under D–D-neutron irradiation by means of the ING-07D neutron generator with the yield of 1 × 107 n/s. The GEANT4 simulation provided us with the comprehensive overview of detector performance. The acquired results demonstrate the possibility of using the LaCl3(Ce) scintillation spectrometer for the purposes of deuterium plasma neutron diagnostics.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043528
Novel LaCl3(Ce)-based spectrometer for deuterium plasma neutron diagnostics
This work studies in detail the application possibility of a chlorine-based cerium-doped scintillator crystal [LaCl3(Ce)] to the task of D–D neutron spectrometry. We conducted an experimental campaign aimed at deriving the optimal setup parameters and energy calibration using a variety of available neutrons and γ-sources. The GEANT4 code was used for modeling the detector response to γ-ray irradiation. By observing the intrinsic background α-activity of the crystal, we were able to fine-tune the pulse-shape discrimination parameters, achieving a satisfactory α/n/γ pulse selection. We also investigated the LaCl3(Ce)-based spectrometer response under D–D-neutron irradiation by means of the ING-07D neutron generator with the yield of 1 × 107 n/s. The GEANT4 simulation provided us with the comprehensive overview of detector performance. The acquired results demonstrate the possibility of using the LaCl3(Ce) scintillation spectrometer for the purposes of deuterium plasma neutron diagnostics.
- 24 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (4) , 688-693
Study of the Data Acquisition System for ITER Divertor Neutron Flux Monitor Diagnostic
Diagnostic "Divertor Neutron Flux Monitor" is one of the diagnostics to determine the neutron yield and the thermonuclear power of the ITER facility. To detect neutrons this diagnostic uses three detector modules. The expected neutron flux in the detector modules location is 10 6 to 10 13 n·cm-27s -1. The neuron flux and the neutron yield should be measured with 1 ms time resolution and 10 % maximum relative error. The detector module consisting of six fission chambers is used to meet these requirements and each fission chamber signal is processed by pulse-counting, Campbell and current measurement methods simultaneously. According to the data of the each measurement method the normalized count rates of the fission chambers and the detector module and the neutron flux at its location are calculated. The data acquisition system processes the signals of the single detector module and transmits data of the normalized count rate and the neutron flux of each detector and the entire detector module to the upper level system. To verify the techniques solutions the data acquisition system prototype was manufactured. To study the characteristics of this prototype a set of laboratory tests were carried out. This paper illustrates the structure of the data acquisition system and the implementation of the fission chamber signals processing methods. The results of the study of the data acquisition system prototype for single detector module are given.
- 24 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (4) , 688-693
Study of the Data Acquisition System for ITER Divertor Neutron Flux Monitor Diagnostic
Diagnostic "Divertor Neutron Flux Monitor" is one of the diagnostics to determine the neutron yield and the thermonuclear power of the ITER facility. To detect neutrons this diagnostic uses three detector modules. The expected neutron flux in the detector modules location is 10 6 to 10 13 n·cm-27s -1. The neuron flux and the neutron yield should be measured with 1 ms time resolution and 10 % maximum relative error. The detector module consisting of six fission chambers is used to meet these requirements and each fission chamber signal is processed by pulse-counting, Campbell and current measurement methods simultaneously. According to the data of the each measurement method the normalized count rates of the fission chambers and the detector module and the neutron flux at its location are calculated. The data acquisition system processes the signals of the single detector module and transmits data of the normalized count rate and the neutron flux of each detector and the entire detector module to the upper level system. To verify the techniques solutions the data acquisition system prototype was manufactured. To study the characteristics of this prototype a set of laboratory tests were carried out. This paper illustrates the structure of the data acquisition system and the implementation of the fission chamber signals processing methods. The results of the study of the data acquisition system prototype for single detector module are given.
- 31 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2421-2425
Fission Chambers Detector Unit Mockup Testing at Research Reactors
This paper presents the results of the fission chambers (FC) behavior under intensive neutron and gamma radiation at the research reactors. The FC detector unit (DU) was designed for the International Experimental Thermonuclear Reactor neutron diagnostic “divertor neutron flux monitor.” Two mockups of the DU with FCs containing 1 g and 100 mg of 235 U were tested. The test complex is based on the FC signal processing unit and the FC parameters' monitoring system. The processing unit contains several measuring chains and acquire FC signal over a wide range of neutron flux variation. The FC parameters' monitoring system records signal shapes, acquires pulse-height amplitude spectra, and checks electrical parameters of the neutron detector. The radiation tests were carried out at the research reactors IRT MEPhI and VVR-c. The structure and characteristics of the test complex as well measurement techniques and tools for FC characterization are discussed. The results of reactor experiments to determine characteristics of the DU mockup and wide-range neutron flux monitoring channels are presented.
- 31 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2421-2425
Fission Chambers Detector Unit Mockup Testing at Research Reactors
This paper presents the results of the fission chambers (FC) behavior under intensive neutron and gamma radiation at the research reactors. The FC detector unit (DU) was designed for the International Experimental Thermonuclear Reactor neutron diagnostic “divertor neutron flux monitor.” Two mockups of the DU with FCs containing 1 g and 100 mg of 235 U were tested. The test complex is based on the FC signal processing unit and the FC parameters' monitoring system. The processing unit contains several measuring chains and acquire FC signal over a wide range of neutron flux variation. The FC parameters' monitoring system records signal shapes, acquires pulse-height amplitude spectra, and checks electrical parameters of the neutron detector. The radiation tests were carried out at the research reactors IRT MEPhI and VVR-c. The structure and characteristics of the test complex as well measurement techniques and tools for FC characterization are discussed. The results of reactor experiments to determine characteristics of the DU mockup and wide-range neutron flux monitoring channels are presented.
- 16 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2392-2397
Data Acquisition System for ITER Neutron Diagnostic Divertor Neutron Flux Monitor
Neutron diagnostic "Divertor Neutron Flux Monitor" is being under development for the ITER project. This diagnostic is a primary tool for total neutron yield and fusion power measurements. Diagnostic consists of the three detector modules and the enhanced data acquisition systems. Each module contains three fission chambers with 235U and three with 238U. The choice of the fission chambers types and sensitivities is determined by the project requirements for the neutron flux measurement range, error and time resolution. The data acquisition system performs preliminary amplification and processing of the fission chamber signals, calculation of the neutron flux at the module location to calculate the total neutron yield and fusion power. The data acquisition system transfers measured data to the upper-level of the control system with a time resolution of 1 ms and provides raw data archiving. The hardware and software of the data acquisition system was developed taking into account the requirements of the ITER project. The data processing system mockup of a single detection module was manufactured. This mockup passed laboratory and reactor tests. The system has passed the preliminary design approval. Preparation for the manufacturing of the system prototype is carried out at this moment. The architecture of the data acquisition system and its components are shown in the report and the test results of the system mockup are discussed.
- 16 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2392-2397
Data Acquisition System for ITER Neutron Diagnostic Divertor Neutron Flux Monitor
Neutron diagnostic "Divertor Neutron Flux Monitor" is being under development for the ITER project. This diagnostic is a primary tool for total neutron yield and fusion power measurements. Diagnostic consists of the three detector modules and the enhanced data acquisition systems. Each module contains three fission chambers with 235U and three with 238U. The choice of the fission chambers types and sensitivities is determined by the project requirements for the neutron flux measurement range, error and time resolution. The data acquisition system performs preliminary amplification and processing of the fission chamber signals, calculation of the neutron flux at the module location to calculate the total neutron yield and fusion power. The data acquisition system transfers measured data to the upper-level of the control system with a time resolution of 1 ms and provides raw data archiving. The hardware and software of the data acquisition system was developed taking into account the requirements of the ITER project. The data processing system mockup of a single detection module was manufactured. This mockup passed laboratory and reactor tests. The system has passed the preliminary design approval. Preparation for the manufacturing of the system prototype is carried out at this moment. The architecture of the data acquisition system and its components are shown in the report and the test results of the system mockup are discussed.