WKWataru Kokuyama

Wataru Kokuyama

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wataru Kokuyama has a total of 328 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Temperature Dependence of Broadband Seismometer Sensitivity

    by Tomofumi Shimoda, Wataru Kokuyama, Hideaki Nozato

    Broadband seismometers are widely used in global observation networks deployed for geophysics research. Recently, the calibration of their sensitivity has become an important factor for ensuring observation accuracy. One of the limiting factors of calibration uncertainty is the temperature dependence of the sensitivity because seismometers operate in a wide range of temperatures. However, systems that accurately measure the temperature coefficient of sensitivity in seismometers have not been established. Herein, we develop such a system using a triaxial vibration exciter combined with a thermostatic chamber. Using this system, we calibrated several broadband seismometers (Trillium Compact 120s, Trillium Horizon 360, and CMG-3T-360) at various temperatures, ranging from −15°C to + 45°C. The power supply and digitizer were kept at room temperature (23°C) so that only the sensor itself was investigated. We found that the temperature coefficient of the midband sensitivity was (0.11 ± 0.01) %/°C, which can be attributed to the internal magnet of the seismometers. The variation of the phase delay corresponded to a change of less than 2 ms in output time delay. In addition, we found that the relative frequency response below 1 Hz was stable against temperature variations. These values are useful for evaluating the measurement accuracy of seismometer observation networks.

  • Open Access

    Phase noise suppression in an optical-fiber-based interferometer using ultralow-noise lasers for quantum communication

    by Tsubasa Kashimura, Yuto Shitaka, Yohei Sugiyama, Wataru Kokuyama, Kanta Asakawa, Daisuke Akamatsu, Feng-Lei Hong

    The frequency noise of an external-cavity diode laser locked to an ultralow-expansion cavity (cavity-stabilized laser) and a whispering-gallery-mode (WGM) cavity optical-feedback semiconductor laser (WGM laser) was evaluated. The frequency noise of the WGM laser was approximately two orders of magnitude smaller than that of the cavity-stabilized laser at high Fourier frequencies. Using the WGM laser, phase noise reduction of approximately two orders of magnitude was observed in the dual-band stabilization of an optical-fiber-based interferometer at high Fourier frequencies. This noise reduction should improve the measurement fidelity in quantum key and entanglement distributions in long-distance quantum communication.

  • On-Site Comparison Calibration of Broadband Seismometers with Temperature Correction

    by Tomofumi Shimoda, Akito Araya, Wataru Kokuyama, Hideaki Nozato

    Calibration of seismometer sensitivity in observational networks is essential to ensure measurement accuracy. One of the most accurate calibration methods is on-site comparison calibration, an approach developed over the past decade. In this approach, a calibrated seismometer is installed near the target seismometer, and their local vibration signals are compared to calculate the target sensitivity. However, changes in the reference seismometer sensitivity due to temperature dependence degrade comparison calibration accuracy. This study proposes a comparison calibration system incorporating temperature correction. The accuracy of the reference sensitivity was improved by applying correction based on temperature monitoring. Using the proposed system, STS-1 seismometers were calibrated in their operational state. The midband sensitivity around 0.5 Hz was determined with uncertainties of 0.3%–0.5%, which satisfies the requirement of the observational networks. An unidentified delay of 28 ms was also found in the seismometer or the data logger. Furthermore, the relative frequency response down to 0.02 Hz was determined, and the shift of the cutoff frequency was identified. These results will help establish an on-site comparison calibration process.


  • Open Access

    Accurate laboratory testing of low-frequency triaxial vibration sensors under various temperature conditions

    by Tomofumi Shimoda, Wataru Kokuyama, Hideaki Nozato

    Triaxial vibration sensors are widely used in various application. Recently, low-cost sensors based on micro electro mechanical system (MEMS) technology are also becoming more widely adopted. However, their measurement accuracy can be affected by environmental factors such as temperature. In this study, we developed an environmental testing system integrated with a triaxial vibration exciter. The system can reproduce long-stroke, low-frequency triaxial vibrations—such as those caused by huge earthquakes—under temperatures ranging from − 30 ∘ C to + 80 ∘ C . Using this system, the measurement accuracy of vibration sensors can be evaluated under different environmental conditions. The system provides highly accurate reference measurements using a laser interferometer and reference accelerometers that are primarily calibrated within the system. The overall accuracy of the reference vibration measurement is estimated to be approximately 1.1% below 10 Hz. Based on these reference measurements, we investigated the accuracy of earthquake observations using a MEMS accelerometer as a demonstration. The system configuration and testing procedures are presented in this paper.


  • Open Access

    FMCW LiDAR with a GaN-based distributed feedback laser diode at 466 nm

    by Wataru Kokuyama, Hidemi Tsuchida, Yoshiaki Nakajima

    Frequency-modulated continuous-wave (FMCW) LiDAR requires a visible narrow-linewidth laser capable of a wide linear chirp for operations in underwater environments. To this end, we evaluated a GaN-based 466 nm distributed feedback laser diode (DFB-LD) using a delayed self-heterodyne interferometer, measuring its modulation waveform. The chirp span reached a 12.2 GHz peak-to-peak value (Fourier-limited theoretical resolution: 0.92 cm in the water). The modulation nonlinearity was 9% full scale, and the coherence length was 14 m (β-separation linewidth: 1.9 MHz). Using the proposed LD, we demonstrated free-space FMCW LiDAR at ∼3 m without predistortion. Although the resolution degraded to ∼2 m due to nonlinearity and frequency noise, this work represents, to our knowledge, the first experimental demonstration of FMCW LiDAR using a visible DFB-LD, showing its potential for visible coherent sensing.


  • Phase stabilization with triple wavelength bands for single-photon interference in quantum communication

    by Yohei Sugiyama, Akito Ozawa, Wataru Kokuyama, Tomoyuki Horikiri, Daisuke Akamatsu, Feng-Lei Hong

    Optical interferometers are crucial for long-distance quantum communications. We propose a novel phase stabilization method employing triple wavelength bands for single-photon interference in optical fiber-based interferometers, incorporating a simplified laser frequency stabilization technique that utilizes a single nonlinear crystal. After stabilization, the residual phase noise of the fiber interferometer was 20 mrad for differential arm lengths (Δ L ) of 0 and 10 m. This represents a 9-fold and 7.5-fold improvement for Δ L = 0 and 10 m, respectively, compared with those observed in previous double-wavelength methods. These findings enhance the visibility and simplicity of quantum key and entanglement distributions in long-distance quantum communication.


  • Optical sound pressure measurement using Fabry-Pérot cavity for primary acoustic standards

    by Koto Hirano, Wataru Kokuyama, Hajime Inaba, Sho Okubo, Tomofumi Shimoda, Hironobu Takahashi, Keisuke Yamada, Hideaki Nozato

    Optical sound pressure measurement is a promising technology to establish primary acoustic standards without reliance on specific types of microphones. We developed a precision optical sound pressure measurement system by combining a Fabry–Pérot optical cavity, a phase-stabilized optical frequency comb, and a custom-made phasemeter. The optical cavity detects changes in the air's refractive index induced by sound waves as changes in its resonance frequency. A continuous-wave laser frequency is stabilized at the resonance, and the frequency comb detects the changes in the laser frequency. The frequency changes are measured with high sensitivity and accuracy using a phasemeter that we developed. The sound pressures measured by this system agreed with the measurement value obtained using a reference microphone within 5% at sound pressure levels of 78 and 84 dB, within a frequency range of 100 Hz to 1 kHz. A systematic deviation of 2.6% was observed, with the optical system yielding higher values than the microphone. To identify the cause of this deviation, we performed vibration displacement measurements of the cavity mirrors and finite element analysis, which revealed that fluctuations in the optical path length due to insufficient fixation of the mirrors were responsible.


  • Open Access

    FMCW LiDAR with a GaN-based distributed feedback laser diode at 466 nm

    by Wataru Kokuyama, Hidemi Tsuchida, Yoshiaki Nakajima

    Frequency-modulated continuous-wave (FMCW) LiDAR requires a visible narrow-linewidth laser capable of a wide linear chirp for operations in underwater environments. To this end, we evaluated a GaN-based 466 nm distributed feedback laser diode using a delayed self-heterodyne interferometer, measuring its modulation waveform. The chirp span reached a 12.2 GHz peak-to-peak value (Fourier-limited resolution: 0.92 cm in the water). The modulation nonlinearity was 9% full scale, and the coherence length was 14 m (β-separation linewidth: 1.9 MHz). Using the proposed LD, we demonstrated free-space FMCW LiDAR at ~3 m without predistortion, which is, to our knowledge, the first experimental demonstration of FMCW LiDAR using a visible DFB-LD, showing its potential for visible coherent sensing.

  • Open Access

    FMCW LiDAR with a GaN-based distributed feedback laser diode at 466 nm

    by Wataru Kokuyama, Hidemi Tsuchida, Yoshiaki Nakajima

    Frequency-modulated continuous-wave (FMCW) LiDAR requires a visible narrow-linewidth laser capable of a wide linear chirp for operations in underwater environments. To this end, we evaluated a GaN-based 466 nm distributed feedback laser diode using a delayed self-heterodyne interferometer, measuring its modulation waveform. The chirp span reached a 12.2 GHz peak-to-peak value (Fourier-limited resolution: 0.92 cm in the water). The modulation nonlinearity was 9% full scale, and the coherence length was 14 m (β-separation linewidth: 1.9 MHz). Using the proposed LD, we demonstrated free-space FMCW LiDAR at ~3 m without predistortion, which is, to our knowledge, the first experimental demonstration of FMCW LiDAR using a visible DFB-LD, showing its potential for visible coherent sensing.