Akihiro Ota
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Akihiro Ota has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hideaki Nozato
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
7 shared publications - Wataru Kokuyama
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
7 shared publications Hisayuki Aoyama
Dept. of Mechanical Engineering & Intelligent Systems, University of Electro-Communications (UEC), 1-5-1Chofugaoka, Chofu, Tokyo, Japan
4 shared publications- Takashi Usuda
National Institute of Advanced Industrial Science and Technology (Japan)
4 shared publications - Ohmi Fuchiwaki
Department of Mechanical Engineering Yokohama National University Yokohama Japan
2 shared publications Sojun Sato
National Institute of Advanced Industrial Science and Technology (Japan)
2 shared publications
Latest Publications
- 7 July 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (10) , 109501
Corrigendum: Simple digital phase-measuring algorithm for low-noise heterodyne interferometry (2016 Meas. Sci. Technol. 27 085001)
- 7 July 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (10) , 109501
Corrigendum: Simple digital phase-measuring algorithm for low-noise heterodyne interferometry (2016 Meas. Sci. Technol. 27 085001)
- 1 January 2017
- Published by The Editorial Committee of Synthesiology in Synthesiology English edition
- Vol. 10 (2) , 47-61
Establishing reliability in vibration measurement and its international equivalency
- 1 January 2017
- Published by The Editorial Committee of Synthesiology in Synthesiology English edition
- Vol. 10 (2) , 47-61
Establishing reliability in vibration measurement and its international equivalency
- 1 March 2016
- Published by Elsevier in Measurement
- Vol. 82, 246-253
Angular velocity calibration system with a self-calibratable rotary encoder
- 1 March 2016
- Published by Elsevier in Measurement
- Vol. 82, 246-253
Angular velocity calibration system with a self-calibratable rotary encoder
- 1 January 2016
- Published by Elsevier in Measurement
- Vol. 77, 67-72
Improvement and validity of shock measurements using heterodyne laser interferometer
- 1 January 2016
- Published by Elsevier in Measurement
- Vol. 77, 67-72
Improvement and validity of shock measurements using heterodyne laser interferometer
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Measurement of angle error of gyroscopes using a rotary table enhanced by self-calibratable rotary encoder
This paper reports a novel system to evaluate angle error of rate-integrating gyroscopes. The system equips with a self-calibratable rotary encoder (SelfA) so that it has enough angle accuracy below 10-4-degree level even in rotation at several tens of degrees per second. Angle errors in such a small level cannot be measured with ordinary rotary tables. Therefore, our system can contribute to characterization of high-performance inertial sensors.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Measurement of angle error of gyroscopes using a rotary table enhanced by self-calibratable rotary encoder
This paper reports a novel system to evaluate angle error of rate-integrating gyroscopes. The system equips with a self-calibratable rotary encoder (SelfA) so that it has enough angle accuracy below 10-4-degree level even in rotation at several tens of degrees per second. Angle errors in such a small level cannot be measured with ordinary rotary tables. Therefore, our system can contribute to characterization of high-performance inertial sensors.
- 1 January 2015
- Published by Springer Nature
- p. 169-173
Shock Calibration with Zero Shift Using a Digital Filter Technique
- 1 January 2015
- Published by Springer Nature
- p. 169-173
Shock Calibration with Zero Shift Using a Digital Filter Technique
- Open Access
- 15 January 2014
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 2 (2) , 61-66
Digital demodulator unit of laser vibrometer standard for in situ measurement
To establish an easy-to-use traceability system for laser vibrometers in vibration acceleration standard, a highly accurate reference standard is required. In this study, we investigated the measurement reliability of a commercial laser vibrometer with an analog demodulator. The results confirmed a large measurement deviation from nominal sensitivity values due to characteristics of the analog demodulator. To reduce such deviation, a high-accuracy digital demodulator, which can be utilized as a reference standard, was developed. The experimental results confirmed the improved measurement accuracy of the developed digital demodulator.
- 15 January 2014
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 2 (2) , 61-66
Open AccessDigital demodulator unit of laser vibrometer standard for in situ measurement
To establish an easy-to-use traceability system for laser vibrometers in vibration acceleration standard, a highly accurate reference standard is required. In this study, we investigated the measurement reliability of a commercial laser vibrometer with an analog demodulator. The results confirmed a large measurement deviation from nominal sensitivity values due to characteristics of the analog demodulator. To reduce such deviation, a high-accuracy digital demodulator, which can be utilized as a reference standard, was developed. The experimental results confirmed the improved measurement accuracy of the developed digital demodulator.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 83-88
Development of a positioning & compensation device for a versatile micro robot
In this paper, we describe the design and development of a positioning and compensation device for a versatile micro robot. To provide microscopic operations, the versatile micro robot has developed. The robot can move in any direction in the manner of an inchworm. However many positioning errors exist because of an assembling error in the four piezoelectric actuators and two electromagnets. We need an automatic positioning device for more accurate work. Motion compensation is also highly required for more effective work. This robot is very small, so it can easily be set to work with the various devices. The positing device should also be small so that we can carry the device easily and set it up in a narrow working area. In this report, we propose a USB camera based positioning device with special compensation function. In experiments, we succeeded in controlling the robot on an octagonal path with controlling the posture angle freely. When we compensate for the motion, the positioning time becomes 60 % compared to that of no compensation. The design procedure, basic performance and biomedical application are also discussed as an advance in the new field of micro-robotics used in precision regions.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 83-88
Development of a positioning & compensation device for a versatile micro robot
In this paper, we describe the design and development of a positioning and compensation device for a versatile micro robot. To provide microscopic operations, the versatile micro robot has developed. The robot can move in any direction in the manner of an inchworm. However many positioning errors exist because of an assembling error in the four piezoelectric actuators and two electromagnets. We need an automatic positioning device for more accurate work. Motion compensation is also highly required for more effective work. This robot is very small, so it can easily be set to work with the various devices. The positing device should also be small so that we can carry the device easily and set it up in a narrow working area. In this report, we propose a USB camera based positioning device with special compensation function. In experiments, we succeeded in controlling the robot on an octagonal path with controlling the posture angle freely. When we compensate for the motion, the positioning time becomes 60 % compared to that of no compensation. The design procedure, basic performance and biomedical application are also discussed as an advance in the new field of micro-robotics used in precision regions.
- Open Access
- 1 January 2007
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 73 (10) , 1164-1168
Development of Versatile Micro Robot for Microscopic Operation (5th report)
- 1 January 2007
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 73 (10) , 1164-1168
Open AccessDevelopment of Versatile Micro Robot for Microscopic Operation (5th report)
- 19 June 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6345, 634503
Preliminary implementation of primary calibration system for laser vibrometer
In this paper, we outline a preliminary implementation of primary calibration for a laser vibrometer (LV) on the basis of newly proposed first ISO draft. The sine approximation method is applied to our calibration system. Under some different measurement conditions, primary calibration is preliminarily carried out for achieving reliable measurements. From these results, the effects of acceleration amplitude stability, mechanical distortion, position of measuring beam, and spot diameter of measuring beam have been discussed. Some conditions required for achieving the reliable calibration is indicated on the basis of the discussion. Additionally, the strict regulations of the distance between spots and such amount of mechanical distortion would be indispensable for guaranteeing a higher reliability of such calibration within an expanded uncertainty (k = 2) of less than 0.5 %.
- 19 June 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6345, 634503
Preliminary implementation of primary calibration system for laser vibrometer
In this paper, we outline a preliminary implementation of primary calibration for a laser vibrometer (LV) on the basis of newly proposed first ISO draft. The sine approximation method is applied to our calibration system. Under some different measurement conditions, primary calibration is preliminarily carried out for achieving reliable measurements. From these results, the effects of acceleration amplitude stability, mechanical distortion, position of measuring beam, and spot diameter of measuring beam have been discussed. Some conditions required for achieving the reliable calibration is indicated on the basis of the discussion. Additionally, the strict regulations of the distance between spots and such amount of mechanical distortion would be indispensable for guaranteeing a higher reliability of such calibration within an expanded uncertainty (k = 2) of less than 0.5 %.