Mohammad Hadi Shahrokh Abadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohammad Hadi Shahrokh Abadi has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Mohd Nizar Hamidon
Universiti Putra Malaysia
4 shared publications - Abdul Halim Shaari
Superconductor and Thin Film Laboratory, Department of Physics, Faculty of Science, Universiti Putra Malaysia, UPM, Serdang 43400, Selangor Darul Ehsan, Malaysia
3 shared publications Majid Toghyani Rizi
Faculty of Electrical and Computer Engineering, Hakim Sabzevari University, Sabzevar, 9617976487, Iran
3 shared publicationsMina Malekzadeh
3 shared publications- Norhafizah Abdullah
Universiti Putra Malaysia
3 shared publications - Rahman Wagiran
Department of Electrical and Electronic Engineering, Faculty of Engineering, University Putra Malaysia, UPM, Serdang, Selangor 43400, Malaysia
3 shared publications
Latest Publications
- Open Access
- 25 July 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (8) , 858
A Monolithic, Thiol-Functionalized Au-Based Bio-CMOS Aptasensor for Rapid, Label-Free Detection of Escherichia coli O157:H7 in Patient-Derived and Hospital-Acquired Specimens
Rapid, point-of-care detection of Escherichia coli O157:H7 remains an unmet clinical need, as culture and molecular methods are slow and poorly suited to decentralized or emergency settings. A label-free, monolithic aptasensor biochip was fabricated in a standard 65 nm CMOS process, featuring three aptamer-functionalized gold sensing pads with matched reference pads for differential readout. A 37-mer DNA aptamer targeting the E. coli O157:H7 lipopolysaccharide was immobilized via thiol–gold self-assembled monolayer chemistry. Binding events were transduced into surface-potential shifts, amplified by an on-chip analog front-end (~100 V/V gain, 101.5 µW), and evaluated using calibration standards, patient specimens, and hospital environmental samples, with fluorescence microscopy for validation. The sensor achieved 47.42 mV/decade sensitivity across 1–10,000 CFU/mL, an IUPAC detection limit near 3.74 CFU/mL, and an empirical LOD of about 11 CFU/mL, with outputs tracking bacterial load and ~5.7% matrix-related deviation. Hospital samples were detectable to 28 CFU/mL. Because the patient-derived and hospital-acquired cohorts (n = 10 and n = 6, respectively) were assembled for pilot analytical and matrix-tolerance characterization rather than for diagnostic-accuracy determination, these results establish detectability and matrix robustness in real clinical and environmental specimens rather than clinical diagnostic sensitivity or specificity, which will require a larger, prospectively enrolled cohort in future work. Sensor kinetics followed Langmuir-type adsorption, saturating within 16–25 min for target pathogens versus slower responses for non-target strains. Selectivity tests against six bacterial species showed discrimination, with cross-reactivity decreasing from related E. coli pathotypes to Enterobacteriaceae to Gram-positive species. Inter-pad variability stayed below 1.5 mV, supporting this compact, low-power platform for scalable, enrichment-free point-of-care pathogen detection.
- 25 July 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (8) , 858
Open AccessA Monolithic, Thiol-Functionalized Au-Based Bio-CMOS Aptasensor for Rapid, Label-Free Detection of Escherichia coli O157:H7 in Patient-Derived and Hospital-Acquired Specimens
Rapid, point-of-care detection of Escherichia coli O157:H7 remains an unmet clinical need, as culture and molecular methods are slow and poorly suited to decentralized or emergency settings. A label-free, monolithic aptasensor biochip was fabricated in a standard 65 nm CMOS process, featuring three aptamer-functionalized gold sensing pads with matched reference pads for differential readout. A 37-mer DNA aptamer targeting the E. coli O157:H7 lipopolysaccharide was immobilized via thiol–gold self-assembled monolayer chemistry. Binding events were transduced into surface-potential shifts, amplified by an on-chip analog front-end (~100 V/V gain, 101.5 µW), and evaluated using calibration standards, patient specimens, and hospital environmental samples, with fluorescence microscopy for validation. The sensor achieved 47.42 mV/decade sensitivity across 1–10,000 CFU/mL, an IUPAC detection limit near 3.74 CFU/mL, and an empirical LOD of about 11 CFU/mL, with outputs tracking bacterial load and ~5.7% matrix-related deviation. Hospital samples were detectable to 28 CFU/mL. Because the patient-derived and hospital-acquired cohorts (n = 10 and n = 6, respectively) were assembled for pilot analytical and matrix-tolerance characterization rather than for diagnostic-accuracy determination, these results establish detectability and matrix robustness in real clinical and environmental specimens rather than clinical diagnostic sensitivity or specificity, which will require a larger, prospectively enrolled cohort in future work. Sensor kinetics followed Langmuir-type adsorption, saturating within 16–25 min for target pathogens versus slower responses for non-target strains. Selectivity tests against six bacterial species showed discrimination, with cross-reactivity decreasing from related E. coli pathotypes to Enterobacteriaceae to Gram-positive species. Inter-pad variability stayed below 1.5 mV, supporting this compact, low-power platform for scalable, enrichment-free point-of-care pathogen detection.
- Open Access
- 9 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Reviews
- Vol. 3, 117-135
Advancements in Detection of Vibrio Cholerae-Based Optical Biosensors
The COVID-19 pandemic has demonstrated the critical value of rapid, sensitive, and field-deployable pathogen detection, highlighting strategies that can be applied to other infectious agents, including Vibrio cholerae (VC). Lessons from COVID-19 diagnostics, such as the use of portable biosensors, signal amplification, and point-of-care testing, directly inform the development of rapid VC detection tools. Cholera, a severe diarrheal disease caused by VC, remains a major global health threat, especially in regions with poor sanitation. Conventional methods, including bacterial culture and polymerase chain reaction (PCR), are often slow and resource-intensive, limiting their suitability for field deployment. Optical biosensors have emerged as a promising alternative, offering rapid, sensitive, and portable detection. This review critically examines recent progress in optical biosensor technologies for VC, focusing on transducer types, biorecognition elements, and signal amplification strategies. Notably, we highlight trends such as the development of aptamer-based lateral flow assays, integration of quantum dots, and the application of optical fibers and photonic crystals for ultra-sensitive detection. We evaluate these technologies in terms of analytical performance, including limit of detection (LoD), linear range, and sensitivity, and compare them with alternative biosensing modalities, such as microfluidic platforms and conventional LFAs. Finally, we discuss remaining challenges, identify gaps in current approaches, and propose strategic directions for advancing portable, point-of-care VC diagnostics that can bridge the gap between laboratory research and real-world outbreak management.
- 9 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Reviews
- Vol. 3, 117-135
Open AccessAdvancements in Detection of Vibrio Cholerae-Based Optical Biosensors
The COVID-19 pandemic has demonstrated the critical value of rapid, sensitive, and field-deployable pathogen detection, highlighting strategies that can be applied to other infectious agents, including Vibrio cholerae (VC). Lessons from COVID-19 diagnostics, such as the use of portable biosensors, signal amplification, and point-of-care testing, directly inform the development of rapid VC detection tools. Cholera, a severe diarrheal disease caused by VC, remains a major global health threat, especially in regions with poor sanitation. Conventional methods, including bacterial culture and polymerase chain reaction (PCR), are often slow and resource-intensive, limiting their suitability for field deployment. Optical biosensors have emerged as a promising alternative, offering rapid, sensitive, and portable detection. This review critically examines recent progress in optical biosensor technologies for VC, focusing on transducer types, biorecognition elements, and signal amplification strategies. Notably, we highlight trends such as the development of aptamer-based lateral flow assays, integration of quantum dots, and the application of optical fibers and photonic crystals for ultra-sensitive detection. We evaluate these technologies in terms of analytical performance, including limit of detection (LoD), linear range, and sensitivity, and compare them with alternative biosensing modalities, such as microfluidic platforms and conventional LFAs. Finally, we discuss remaining challenges, identify gaps in current approaches, and propose strategic directions for advancing portable, point-of-care VC diagnostics that can bridge the gap between laboratory research and real-world outbreak management.
- Open Access
- 24 November 2024
- Published by Springer Nature in Optical Review
- Vol. 31 (6) , 625
Correction to: Effect of MoS2 and (phosphorene, germanene, borophene) hybrid structure on the performance of an SPR biosensor for detection of bacteria
- 24 November 2024
- Published by Springer Nature in Optical Review
- Vol. 31 (6) , 625
Open AccessCorrection to: Effect of MoS2 and (phosphorene, germanene, borophene) hybrid structure on the performance of an SPR biosensor for detection of bacteria
- 11 March 2024
- Published by Springer Nature in Optical Review
- Vol. 31 (6) , 615-624
Effect of MoS2 and (phosphorene, germanene, borophene) hybrid structure on the performance of an SPR biosensor for detection of bacteria
- 11 March 2024
- Published by Springer Nature in Optical Review
- Vol. 31 (6) , 615-624
Effect of MoS2 and (phosphorene, germanene, borophene) hybrid structure on the performance of an SPR biosensor for detection of bacteria
- 27 February 2023
- Published by Springer Nature in Sensing and Imaging
- Vol. 24 (1) , 1-15
A Simple and Feasible Detection of Pipe/Tank-Wall Thinning and Corrosion Using Piezoceramic Transducers
- 27 February 2023
- Published by Springer Nature in Sensing and Imaging
- Vol. 24 (1) , 1-15
A Simple and Feasible Detection of Pipe/Tank-Wall Thinning and Corrosion Using Piezoceramic Transducers
- Open Access
- 17 November 2022
- Published by Springer Nature in Research Square
A Simple and Feasible Wall Pipe and Tank Thinning and Corrosion Detection Using Piezoceramic Transducers
Pipe wall thinning and leakage due to corrosion, caused by process restrictions or extensive usage, are significant safety concerns for pipes used in oil, petrochemical, and power plant industries. This paper introduces the feasibility of detecting pipelines and tank thinning damage using piezo-ceramic transducers resonating at 2MHz. Time and frequency processing was used in combination with the Empirical Mode Decomposition (EMD) as a signal processing method in different conditions. A steel box and pipe, as items under test, were used to imitate the real industrial tanks and pipes used in the petroleum industries. The box was exposed to sulfuric acid as a corrosive substance and parts of the steel pipe were shaved from the inside to simulate the corroded areas. The PZCs were installed on the right parts of the IUTs and thickness measurements were performed and compared with the results obtained from a standard commercial thickness gauge. The results show less than a 1% error in thickness compared with the standard equipment when a frequency domain is combined with EMD. Furthermore, the proposed system offers much more simplicity and cost-effectiveness than the standard one.
- 17 November 2022
- Published by Springer Nature in Research Square
Open AccessA Simple and Feasible Wall Pipe and Tank Thinning and Corrosion Detection Using Piezoceramic Transducers
Pipe wall thinning and leakage due to corrosion, caused by process restrictions or extensive usage, are significant safety concerns for pipes used in oil, petrochemical, and power plant industries. This paper introduces the feasibility of detecting pipelines and tank thinning damage using piezo-ceramic transducers resonating at 2MHz. Time and frequency processing was used in combination with the Empirical Mode Decomposition (EMD) as a signal processing method in different conditions. A steel box and pipe, as items under test, were used to imitate the real industrial tanks and pipes used in the petroleum industries. The box was exposed to sulfuric acid as a corrosive substance and parts of the steel pipe were shaved from the inside to simulate the corroded areas. The PZCs were installed on the right parts of the IUTs and thickness measurements were performed and compared with the results obtained from a standard commercial thickness gauge. The results show less than a 1% error in thickness compared with the standard equipment when a frequency domain is combined with EMD. Furthermore, the proposed system offers much more simplicity and cost-effectiveness than the standard one.
- 28 March 2019
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 36 (4) , 1155-1165
Numerical investigation on efficiency improvement of double layer antireflection coating AZO/buffer/Cu2O/CuO on back-surface fluorine-doped tin oxide heterostructure solar cells
Optical and electrical features of solar cells from simple primitive bufferless to complex single/double layer-antireflection coating (S/DLARC) on back-surface fluorine-doped tin oxide (BSF/FTO), were numerically studied. The simulated cells were optimized using a low-conduction band offset buffer, controlled-defect BSF, and antireflection coating layers under a compatible fabrication process. By considering the interlayer defects, the optimized on BSF/FTO exhibits an improved efficiency of 9.17%, with a , a , and a fill factor of 67.22% under simulated illumination (AM 1.5G, ). Finally, the cell underwent simulated moisturized conditions ( at ), where its performance dramatically declined with the exposure time. The results show that the models can be adapted for prediction of the -based-cell behavior prior to fabricating.- 28 March 2019
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 36 (4) , 1155-1165
Numerical investigation on efficiency improvement of double layer antireflection coating AZO/buffer/Cu2O/CuO on back-surface fluorine-doped tin oxide heterostructure solar cells
Optical and electrical features of solar cells from simple primitive bufferless to complex single/double layer-antireflection coating (S/DLARC) on back-surface fluorine-doped tin oxide (BSF/FTO), were numerically studied. The simulated cells were optimized using a low-conduction band offset buffer, controlled-defect BSF, and antireflection coating layers under a compatible fabrication process. By considering the interlayer defects, the optimized on BSF/FTO exhibits an improved efficiency of 9.17%, with a , a , and a fill factor of 67.22% under simulated illumination (AM 1.5G, ). Finally, the cell underwent simulated moisturized conditions ( at ), where its performance dramatically declined with the exposure time. The results show that the models can be adapted for prediction of the -based-cell behavior prior to fabricating.- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 81-84
Aptamers-Based Gold-Micro-Array for High-Selective Detection of Bacteria Using Fluorescence Microscopy
The monitoring of Escherichia coli (E. coli) bacteria in food and water is an effective preventive measure in controlling the outbreaks of serious food-related diseases. Moreover, the accurate detection of its early stage of the bacteria can ensure the public health and safety. In this study, a target-selective aptamer-based platform is proposed as a reliable procedure for the detection of the E. coli in Phosphate-buffered saline (PBS) using fluorescent microscopy. The results show that the aptamer sequences, immobilized on an array of Au-micro-squares, are very high selective towards the target bacteria cells. This platform, presented for the first time, can be potentially used to detect different kinds of cells simultaneously. Also, an important cell-counting application, based on Neubauer Lam high accuracy method, is proposed and implemented and validated by experimental results.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 81-84
Aptamers-Based Gold-Micro-Array for High-Selective Detection of Bacteria Using Fluorescence Microscopy
The monitoring of Escherichia coli (E. coli) bacteria in food and water is an effective preventive measure in controlling the outbreaks of serious food-related diseases. Moreover, the accurate detection of its early stage of the bacteria can ensure the public health and safety. In this study, a target-selective aptamer-based platform is proposed as a reliable procedure for the detection of the E. coli in Phosphate-buffered saline (PBS) using fluorescent microscopy. The results show that the aptamer sequences, immobilized on an array of Au-micro-squares, are very high selective towards the target bacteria cells. This platform, presented for the first time, can be potentially used to detect different kinds of cells simultaneously. Also, an important cell-counting application, based on Neubauer Lam high accuracy method, is proposed and implemented and validated by experimental results.
- Open Access
- 1 February 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-12
COMSOL-Based Modeling and Simulation of SnO2/rGO Gas Sensor for Detection of NO2
Despite SIESTA and COMSOL being increasingly used for the simulation of the sensing mechanism in the gas sensors, there are no modeling and simulation reports in literature for detection of NO2 based rGO/SnO2 sensors. In the present study, we model, simulate, and characterize an NO2 based rGO/SnO2 gas sensor using COMSOL by solving the Poisson’s equations under associated boundary conditions of mass, heat and electrical transitions. To perform the simulation, we use an exposure model for presenting the required NO2, a heat transfer model to obtain a reaction temperature, and an electrical model to characterize the sensor’s response in the presence of the gas. We characterize the sensor’s response in the presence of different concentrations of NO2 at different working temperatures and compare the results with the experimental data, reported by Zhang et al. The results from the simulated sensor show a good agreement with the real sensor with some inconsistencies due to differences between the practical conditions in the real chamber and applied conditions to the analytical equations. The results also show that the method can be used to define and predict the behavior of the rGO-based gas sensors before undergoing the fabrication process.
- 1 February 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-12
Open AccessCOMSOL-Based Modeling and Simulation of SnO2/rGO Gas Sensor for Detection of NO2
Despite SIESTA and COMSOL being increasingly used for the simulation of the sensing mechanism in the gas sensors, there are no modeling and simulation reports in literature for detection of NO2 based rGO/SnO2 sensors. In the present study, we model, simulate, and characterize an NO2 based rGO/SnO2 gas sensor using COMSOL by solving the Poisson’s equations under associated boundary conditions of mass, heat and electrical transitions. To perform the simulation, we use an exposure model for presenting the required NO2, a heat transfer model to obtain a reaction temperature, and an electrical model to characterize the sensor’s response in the presence of the gas. We characterize the sensor’s response in the presence of different concentrations of NO2 at different working temperatures and compare the results with the experimental data, reported by Zhang et al. The results from the simulated sensor show a good agreement with the real sensor with some inconsistencies due to differences between the practical conditions in the real chamber and applied conditions to the analytical equations. The results also show that the method can be used to define and predict the behavior of the rGO-based gas sensors before undergoing the fabrication process.