Ali Elrayyah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ali Elrayyah has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Yilmaz Sozer
Electrical and Computer Engineering Department, University of Akron, Akron, OH, USA
6 shared publications Fatih Cingoz
The University of Akron, Akron, OH, USA
3 shared publications- Tausif Husain
Power Drive Systems, BorgWarner Inc, 355346 Pendleton, Indiana United States 46064
2 shared publications A. Bouselham
Environment and Energy Research Institute, Doha, Qatar
1 shared publication- Hassan Abdelgabir
University of Akron, Akron, OH, USA
1 shared publication - Iqbal Husain
Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
1 shared publication
Latest Publications
- 17 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (6) , 7620-7633
A Complete Small-Signal Modelling and Adaptive Stability Analysis of Nonlinear Droop-Controlled Microgrids
Nonlinear droop control has been introduced to establish an effective power-sharing between distributed generators without the need for communication links in microgrids (MGs). However, one of the missing studies in the literature is the effects of nonlinear droop relations on the stability of the MGs. In this paper, the stability of an inverter-based MG operating with the nonlinear frequency droop-control has been analyzed. A complete small-signal state-space linearized model of the MG system, with optimized nonlinear droop relations, has been developed considering the dynamics of the overall system and is updated periodically. The stability of the system is then checked online at different operating points. Small-signal stability analysis of an islanded microgrid was performed using MATLAB/Simulink and the results were experimentally verified on an MG setup.
- 17 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (6) , 7620-7633
A Complete Small-Signal Modelling and Adaptive Stability Analysis of Nonlinear Droop-Controlled Microgrids
Nonlinear droop control has been introduced to establish an effective power-sharing between distributed generators without the need for communication links in microgrids (MGs). However, one of the missing studies in the literature is the effects of nonlinear droop relations on the stability of the MGs. In this paper, the stability of an inverter-based MG operating with the nonlinear frequency droop-control has been analyzed. A complete small-signal state-space linearized model of the MG system, with optimized nonlinear droop relations, has been developed considering the dynamics of the overall system and is updated periodically. The stability of the system is then checked online at different operating points. Small-signal stability analysis of an islanded microgrid was performed using MATLAB/Simulink and the results were experimentally verified on an MG setup.
- 25 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (4) , 4470-4481
Control Algorithms to Establish Hybrid AC/DC Distribution Systems Using Conventional Six-Switch Inverters
Many economic and technical advantages can be harnessed by establishing hybrid ac/dc distribution systems. However, the penetration of such systems is impeded by the need to modify existing network topologies and to develop new interlinking converters. In this paper, a control scheme is proposed to use conventional six-switch inverters and three-phase networks as hybrid dc/single-phase ac systems. The proposed control scheme can be included in a six-switch inverter along with traditional control schemes of three-phase systems. When the inverter is installed, the appropriate control function can be activated depending on whether it is integrated to a hybrid ac/dc system or to a three-phase ac network. In this way, inverters for hybrid ac/dc system can become ready in the market without a risk of failure in generating demand. The proposed controller addresses the coupling issue between ac and dc sides of the system through an effective estimation of line impedances. Through simulation and experimental studies, the effectiveness of the proposed controller in interlinking ac and dc networks and eliminating the coupling between these two sides is demonstrated and verified.
- 25 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (4) , 4470-4481
Control Algorithms to Establish Hybrid AC/DC Distribution Systems Using Conventional Six-Switch Inverters
Many economic and technical advantages can be harnessed by establishing hybrid ac/dc distribution systems. However, the penetration of such systems is impeded by the need to modify existing network topologies and to develop new interlinking converters. In this paper, a control scheme is proposed to use conventional six-switch inverters and three-phase networks as hybrid dc/single-phase ac systems. The proposed control scheme can be included in a six-switch inverter along with traditional control schemes of three-phase systems. When the inverter is installed, the appropriate control function can be activated depending on whether it is integrated to a hybrid ac/dc system or to a three-phase ac network. In this way, inverters for hybrid ac/dc system can become ready in the market without a risk of failure in generating demand. The proposed controller addresses the coupling issue between ac and dc sides of the system through an effective estimation of line impedances. Through simulation and experimental studies, the effectiveness of the proposed controller in interlinking ac and dc networks and eliminating the coupling between these two sides is demonstrated and verified.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 1-6
Multi-Channel Based Power System for Reliable Operation and Load Sharing
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 1-6
Multi-Channel Based Power System for Reliable Operation and Load Sharing
- 9 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (5) , 3401-3411
Unified Control for Switched Reluctance Motors for Wide Speed Operation
In this paper, a unified controller for switched-reluctance motors is proposed for wide speed operations. In the proposed controller, overlapping regions between the phases are controlled such that direct instantaneous torque control (DITC) and current control (CC) can be implemented simultaneously on different phases. This simplifies the torque sharing during commutation and minimizes torque ripple due to imperfect current tracking and mutual torque. A demagnetization curve concept to demagnetize the phase currents at an optimum angle is introduced to ensure high torque per ampere and single pulse mode operation. This results in extending low ripple operation to medium speed ranges. The seamless combination of DITC, CC and the demagnetization curves lead to torque ripple minimization, automatic excitation angle control and smooth operation over wide speed range. The effectiveness of the proposed unified controller is verified through simulation and experimental studies.
- 9 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (5) , 3401-3411
Unified Control for Switched Reluctance Motors for Wide Speed Operation
In this paper, a unified controller for switched-reluctance motors is proposed for wide speed operations. In the proposed controller, overlapping regions between the phases are controlled such that direct instantaneous torque control (DITC) and current control (CC) can be implemented simultaneously on different phases. This simplifies the torque sharing during commutation and minimizes torque ripple due to imperfect current tracking and mutual torque. A demagnetization curve concept to demagnetize the phase currents at an optimum angle is introduced to ensure high torque per ampere and single pulse mode operation. This results in extending low ripple operation to medium speed ranges. The seamless combination of DITC, CC and the demagnetization curves lead to torque ripple minimization, automatic excitation angle control and smooth operation over wide speed range. The effectiveness of the proposed unified controller is verified through simulation and experimental studies.
- Open Access
- 18 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (4) , 3294-3304
Extending the Speed Range of a Switched Reluctance Motor Using a Fast Demagnetizing Technique
In this paper, a switched reluctance motor (SRM) with phase windings similar to an auto-transformer is presented. The new winding structure allows for fast demagnetization. This enhances the machine performance at high speeds. During demagnetization, the DC bus voltage is applied across the portion of the phase winding which results in higher negative demagnetization voltage/turn and faster discharge of the phase currents. The power electronic converter configuration is modified to facilitate the new winding topology. The number of switches is kept same as the conventional half-bridge converter used in SRMs. The proposed SRM drive with modified winding configuration is verified through finite element analysis based circuit simulations and experimental results.
- 18 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (4) , 3294-3304
Open AccessExtending the Speed Range of a Switched Reluctance Motor Using a Fast Demagnetizing Technique
In this paper, a switched reluctance motor (SRM) with phase windings similar to an auto-transformer is presented. The new winding structure allows for fast demagnetization. This enhances the machine performance at high speeds. During demagnetization, the DC bus voltage is applied across the portion of the phase winding which results in higher negative demagnetization voltage/turn and faster discharge of the phase currents. The power electronic converter configuration is modified to facilitate the new winding topology. The number of switches is kept same as the conventional half-bridge converter used in SRMs. The proposed SRM drive with modified winding configuration is verified through finite element analysis based circuit simulations and experimental results.
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 5 (3) , 1142-1153
Smart Loads Management Using Droop-Based Control in Integrated Microgrid Systems
Demand response (DR) management is a promising strategy in the future power systems as it allows for better resource utilization. Droop control is a widely used method to perform autonomous power management among sources in microgrids (MGs). This paper proposes an approach to adjust loads using droop control to achieve autonomous demand management. This approach has the potential to improve system reliability and ease of management. The proposed droop-based demand response (DB-DR) scheme operates in grid-connected as well as islanded mode of operation. To develop highly effective droop relations, all relevant variables such as MG operating frequency, power flow from the grid, and the load status are included. The proposed DB-DR scheme enables the loads to participate in maintaining supply/demand balance without a need for communication systems. The development of appropriate relations for a DB-DR system is presented and its performance is verified through simulation studies and hardware experiments.
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 5 (3) , 1142-1153
Smart Loads Management Using Droop-Based Control in Integrated Microgrid Systems
Demand response (DR) management is a promising strategy in the future power systems as it allows for better resource utilization. Droop control is a widely used method to perform autonomous power management among sources in microgrids (MGs). This paper proposes an approach to adjust loads using droop control to achieve autonomous demand management. This approach has the potential to improve system reliability and ease of management. The proposed droop-based demand response (DB-DR) scheme operates in grid-connected as well as islanded mode of operation. To develop highly effective droop relations, all relevant variables such as MG operating frequency, power flow from the grid, and the load status are included. The proposed DB-DR scheme enables the loads to participate in maintaining supply/demand balance without a need for communication systems. The development of appropriate relations for a DB-DR system is presented and its performance is verified through simulation studies and hardware experiments.
- 27 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 32 (4) , 2140-2149
Simplified Approach to Analyze Voltage Rise in LV Systems With PV Installations Using Equivalent Power Systems Diagrams
As the photovoltaic (PV) sources capacities in distribution networks continue to grow, more operational challenges are expected to be encountered. One of these challenges is the voltage rise within distribution networks due to reverse power flow from the PV sources toward the grid. In this paper, a simplified analytical approach is presented which allows the voltage rise possibility to be tested and the performance of its mitigation techniques to be evaluated. Equivalent transformations are used to represent complicated power systems using simplified circuits. Then, formulas are derived to determine the PV power limits beyond which a voltage rise will be encountered considering the PV sources capability of absorbing reactive power. Moreover, the system losses in each case are estimated using the proposed formulas. Consequently, the proposed analysis method could be used for a number of applications related to PV sizing and losses minimization. The validity of the proposed method is verified through a number of case studies where its findings are compared with results obtained from DIgSILENT software tools.
- 27 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 32 (4) , 2140-2149
Simplified Approach to Analyze Voltage Rise in LV Systems With PV Installations Using Equivalent Power Systems Diagrams
As the photovoltaic (PV) sources capacities in distribution networks continue to grow, more operational challenges are expected to be encountered. One of these challenges is the voltage rise within distribution networks due to reverse power flow from the PV sources toward the grid. In this paper, a simplified analytical approach is presented which allows the voltage rise possibility to be tested and the performance of its mitigation techniques to be evaluated. Equivalent transformations are used to represent complicated power systems using simplified circuits. Then, formulas are derived to determine the PV power limits beyond which a voltage rise will be encountered considering the PV sources capability of absorbing reactive power. Moreover, the system losses in each case are estimated using the proposed formulas. Consequently, the proposed analysis method could be used for a number of applications related to PV sizing and losses minimization. The validity of the proposed method is verified through a number of case studies where its findings are compared with results obtained from DIgSILENT software tools.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 512-518
Optimized settings of droop parameters using stochastic load modeling for effective DC microgrids operation
Droop control is a widely used technique for load sharing in DC microgrids (MGs); however, its performance is affected significantly by the voltage drops over coupling line impedances causing load sharing errors and voltage degradation across MG bus. Therefore, the locations of the sources in the MG and loading conditions (LCs) have considerable effect on load sharing accuracy and voltage regulation. In this paper, an optimization procedure that takes the MG topology and the load behavior into consideration is proposed to find optimal droop parameters minimizing the impact of the line impedances. In the optimization problem, the required constrains are formulated and the cost function is selected as a combination of current sharing error and the voltage degradation for various LCs. The impact of the different LCs on the cost functions are weighted based on the probabilities of their occurrences that are obtained from the load stochastic model. Particle swarm-based technique is then implemented to provide a solution for defined optimization problem. The performance of the droop controller with the optimal droop parameters is verified through a case study performed on MATLAB/Simulink environment and found to be very effective in achieving the required performance while maintaining inherent droop control such as the stability and robustness.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 512-518
Optimized settings of droop parameters using stochastic load modeling for effective DC microgrids operation
Droop control is a widely used technique for load sharing in DC microgrids (MGs); however, its performance is affected significantly by the voltage drops over coupling line impedances causing load sharing errors and voltage degradation across MG bus. Therefore, the locations of the sources in the MG and loading conditions (LCs) have considerable effect on load sharing accuracy and voltage regulation. In this paper, an optimization procedure that takes the MG topology and the load behavior into consideration is proposed to find optimal droop parameters minimizing the impact of the line impedances. In the optimization problem, the required constrains are formulated and the cost function is selected as a combination of current sharing error and the voltage degradation for various LCs. The impact of the different LCs on the cost functions are weighted based on the probabilities of their occurrences that are obtained from the load stochastic model. Particle swarm-based technique is then implemented to provide a solution for defined optimization problem. The performance of the droop controller with the optimal droop parameters is verified through a case study performed on MATLAB/Simulink environment and found to be very effective in achieving the required performance while maintaining inherent droop control such as the stability and robustness.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5 (10482334) , 3166-3173
Reliability and cost analysis of solar photovoltaic and fuel cell based microgrids
Maintaining a reliable operation in microgrids has significant importance. One factor required for the reliable microgrid operation is to keep certain energy reserve without sacrificing the cost for satisfying any load variation. Reliability and cost optimization of photovoltaic and fuel cell based microgrid system is investigated in this paper. A typical residential load is considered in order to introduce an optimal power sharing approach for cost effective and reliable system operation. A nonlinear frequency droop scheme is then applied to achieve the optimization objectives at the intended operating scenarios. The simulation and experimental results are presented to verify the effectiveness of the proposed technique.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5 (10482334) , 3166-3173
Reliability and cost analysis of solar photovoltaic and fuel cell based microgrids
Maintaining a reliable operation in microgrids has significant importance. One factor required for the reliable microgrid operation is to keep certain energy reserve without sacrificing the cost for satisfying any load variation. Reliability and cost optimization of photovoltaic and fuel cell based microgrid system is investigated in this paper. A typical residential load is considered in order to introduce an optimal power sharing approach for cost effective and reliable system operation. A nonlinear frequency droop scheme is then applied to achieve the optimization objectives at the intended operating scenarios. The simulation and experimental results are presented to verify the effectiveness of the proposed technique.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 4671-4677
Efficient single phase harmonics elimination method for microgrids operating in grid connected or standalone mode
A strategy to eliminate harmonics from the grid current as well as the voltage of the point of common coupling (PCC) for microgrid applications is presented in this paper. The position of the harmonics reduction unit is selected so that it can reduce the harmonics level of the grid current and PCC voltage harmonics irrespective of the distribution of the renewable energy sources in microgrid. The proposed compensation system can be operated in both grid connected and islanded microgrid system without changing any configuration. In the proposed control algorithm, the required amount of attenuation for the harmonics is determined to meet the THD requirement specified by IEEE 519. Fast and efficient algorithm for phase detection irrespective of the presence of harmonics has been utilized for the system. The effectiveness of proposed method is verified by simulation and experimental results.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 4671-4677
Efficient single phase harmonics elimination method for microgrids operating in grid connected or standalone mode
A strategy to eliminate harmonics from the grid current as well as the voltage of the point of common coupling (PCC) for microgrid applications is presented in this paper. The position of the harmonics reduction unit is selected so that it can reduce the harmonics level of the grid current and PCC voltage harmonics irrespective of the distribution of the renewable energy sources in microgrid. The proposed compensation system can be operated in both grid connected and islanded microgrid system without changing any configuration. In the proposed control algorithm, the required amount of attenuation for the harmonics is determined to meet the THD requirement specified by IEEE 519. Fast and efficient algorithm for phase detection irrespective of the presence of harmonics has been utilized for the system. The effectiveness of proposed method is verified by simulation and experimental results.