Joseph Woods
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Joseph Woods has a total of 141 co-authors. Here are the top co-authors by number of shared publications:
- Thomas W. Okell
Oxford Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
20 shared publications - Mark Chiew
Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
10 shared publications - Yang Ji
Medical Imaging Center, Department of Electronic Engineering and Information Science, University of Science and Technology of China
8 shared publications - Moss Y. Zhao
Department of Neurosurgery, Stanford University, Stanford, CA, United States
7 shared publications - Luis Hernandez-Garcia
Department of Radiology University of Michigan Ann Arbor Michigan USA
6 shared publications Greg Zaharchuk
Department of Radiology Stanford University Stanford California USA
5 shared publications
Latest Publications
- Open Access
- 24 May 2026
- Published by Wiley in Magnetic Resonance in Medicine
Inter‐Shot Motion Correction of Segmented 3D ‐ GRASE ASL Perfusion Imaging With Self‐Navigation and CAIPI
Purpose: Segmented 3D Gradient and Spin Echo (GRASE) is commonly used in Arterial Spin Labeling (ASL) perfusion imaging. However, it is vulnerable to inter‐shot motion, leading to subtraction errors that cannot be corrected. We developed a retrospective self‐navigated inter‐shot motion correction method for segmented 3D‐GRASE ASL imaging with Controlled Aliasing in Parallel Imaging (CAIPI). Methods: Multiple shots, each uniformly covering k‐space at distinct sample locations, allow a self‐navigator image to be reconstructed using SENSE for each shot. Rigid‐body motion estimation across the self‐navigators is incorporated into a motion‐compensated forward model for image reconstruction. To support self‐navigation, two CAIPI‐sampled segmented 3D‐GRASE trajectories ensuring full k‐space coverage were explored for point spread function profiles and g‐factor effects. Our approach was evaluated against conventional inter‐volume registration and a previously proposed method, alignedSENSE. Additionally, we compared tag‐control interleaving strategies to assess the impact on motion robustness in five healthy volunteers with instructed head motion. Results: With instructed moderate head motion, our method effectively reduced motion artifacts and outperformed conventional inter‐volume correction by 12.3% in Pearson correlation coefficient, 4.5% in Structural Similarity Index Measure, and 40.1% in temporal SNR. It matched alignedSENSE performance while requiring only 20% of the computational time. All evaluated CAIPI sampling variants enabled robust motion correction, although tradeoffs were observed between through‐plane blurring and SNR. The tag‐control (T/C) inner loop acquisition yielded better motion robustness across quantitative metrics. Conclusion: Self‐navigated inter‐shot motion correction using CAIPI sampling and a T/C inner loop for segmented 3D‐GRASE ASL can improve image quality and motion robustness.
- 24 May 2026
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessInter‐Shot Motion Correction of Segmented 3D ‐ GRASE ASL Perfusion Imaging With Self‐Navigation and CAIPI
Purpose: Segmented 3D Gradient and Spin Echo (GRASE) is commonly used in Arterial Spin Labeling (ASL) perfusion imaging. However, it is vulnerable to inter‐shot motion, leading to subtraction errors that cannot be corrected. We developed a retrospective self‐navigated inter‐shot motion correction method for segmented 3D‐GRASE ASL imaging with Controlled Aliasing in Parallel Imaging (CAIPI). Methods: Multiple shots, each uniformly covering k‐space at distinct sample locations, allow a self‐navigator image to be reconstructed using SENSE for each shot. Rigid‐body motion estimation across the self‐navigators is incorporated into a motion‐compensated forward model for image reconstruction. To support self‐navigation, two CAIPI‐sampled segmented 3D‐GRASE trajectories ensuring full k‐space coverage were explored for point spread function profiles and g‐factor effects. Our approach was evaluated against conventional inter‐volume registration and a previously proposed method, alignedSENSE. Additionally, we compared tag‐control interleaving strategies to assess the impact on motion robustness in five healthy volunteers with instructed head motion. Results: With instructed moderate head motion, our method effectively reduced motion artifacts and outperformed conventional inter‐volume correction by 12.3% in Pearson correlation coefficient, 4.5% in Structural Similarity Index Measure, and 40.1% in temporal SNR. It matched alignedSENSE performance while requiring only 20% of the computational time. All evaluated CAIPI sampling variants enabled robust motion correction, although tradeoffs were observed between through‐plane blurring and SNR. The tag‐control (T/C) inner loop acquisition yielded better motion robustness across quantitative metrics. Conclusion: Self‐navigated inter‐shot motion correction using CAIPI sampling and a T/C inner loop for segmented 3D‐GRASE ASL can improve image quality and motion robustness.
- Open Access
- 7 March 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (1) , 146-160
MOdulation ‐Guided ENcoding ( MOGEN ) Scheme for Vessel‐Encoded Arterial Spin Labeling
Purpose: Vessel‐encoded arterial spin labeling (VEASL) enables simultaneous, non‐contrast imaging of multiple vascular territories that is useful for differential diagnosis and treatment monitoring of cerebrovascular diseases. However, the existing encoding methods are signal‐to‐noise ratio (SNR) inefficient. Methods: We developed a MOdulation‐Guided ENcoding (MOGEN) scheme that directly exploits the inversion spatial modulation profile to obtain SNR‐efficient encoding matrix. Simulations, phantom tests, and healthy volunteer scans were performed to demonstrate its feasibility in multiple application scenarios. Results: Simulation studies demonstrated that MOGEN achieves significantly higher theoretical SNR efficiency than previous methods for both four‐ and six‐artery configurations. In healthy volunteers, MOGEN improved in vivo SNR by approximately 15% and provided more robust vessel decoding, particularly when the spatial modulation deviated from a cosine profile. In patients with Moyamoya disease, MOGEN enabled reliable visualization of collateral pathways even when scan time was reduced to ˜5 min for six arteries. Furthermore, by considering vessel size with multi‐voxel vessel representation, MOGEN enhanced single‐artery selectivity in vessel‐encoded angiography. We also demonstrated that a straightforward approach of off‐resonance correction for VEASL at ultra‐high field was feasible by using MOGEN. Conclusion: MOGEN offered several benefits for VEASL, including high SNR efficiency, flexible spatial modulation and PCASL parameters selection, vessel size consideration, and straightforward off‐resonance correction, thereby substantially improving robustness and usability of VEASL across various applications.
- 7 March 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (1) , 146-160
Open AccessMOdulation ‐Guided ENcoding ( MOGEN ) Scheme for Vessel‐Encoded Arterial Spin Labeling
Purpose: Vessel‐encoded arterial spin labeling (VEASL) enables simultaneous, non‐contrast imaging of multiple vascular territories that is useful for differential diagnosis and treatment monitoring of cerebrovascular diseases. However, the existing encoding methods are signal‐to‐noise ratio (SNR) inefficient. Methods: We developed a MOdulation‐Guided ENcoding (MOGEN) scheme that directly exploits the inversion spatial modulation profile to obtain SNR‐efficient encoding matrix. Simulations, phantom tests, and healthy volunteer scans were performed to demonstrate its feasibility in multiple application scenarios. Results: Simulation studies demonstrated that MOGEN achieves significantly higher theoretical SNR efficiency than previous methods for both four‐ and six‐artery configurations. In healthy volunteers, MOGEN improved in vivo SNR by approximately 15% and provided more robust vessel decoding, particularly when the spatial modulation deviated from a cosine profile. In patients with Moyamoya disease, MOGEN enabled reliable visualization of collateral pathways even when scan time was reduced to ˜5 min for six arteries. Furthermore, by considering vessel size with multi‐voxel vessel representation, MOGEN enhanced single‐artery selectivity in vessel‐encoded angiography. We also demonstrated that a straightforward approach of off‐resonance correction for VEASL at ultra‐high field was feasible by using MOGEN. Conclusion: MOGEN offered several benefits for VEASL, including high SNR efficiency, flexible spatial modulation and PCASL parameters selection, vessel size consideration, and straightforward off‐resonance correction, thereby substantially improving robustness and usability of VEASL across various applications.
- Open Access
Inter-shot Motion Correction of Segmented 3D-GRASE ASL Perfusion Imaging with Self-Navigation and CAIPI
Purpose: Segmented 3D Gradient and Spin Echo (GRASE) is commonly used in Arterial Spin Labeling (ASL) perfusion imaging. However, it is vulnerable to inter-shot motion, leading to subtraction errors that cannot be corrected. We developed a retrospective self-navigated inter-shot motion correction method for segmented 3D-GRASE ASL imaging with Controlled Aliasing in Parallel Imaging (CAIPI). Methods: Multiple shots, each uniformly covering k-space at distinct sample locations, allow a self-navigator image to be reconstructed using SENSE for each shot. Rigid-body motion estimation across the self-navigators is incorporated into a motion-compensated forward model for image reconstruction. To support self-navigation, two CAIPI-sampled segmented 3D-GRASE trajectories that ensure full k-space coverage were explored for point spread function (PSF) profiles and g-factor effects. Our approach was evaluated against conventional inter-volume registration and a previously proposed method, alignedSENSE. Additionally, we compared tag-control interleaving strategies to assess their impact on motion robustness in five healthy volunteers with instructed head motion. Results: Our method effectively reduced motion artifacts and outperformed conventional inter-volume correction by 12.3% in correlation coefficient, 4.5% in Structural Similarity Index Measure (SSIM), and 40.1% in temporal SNR. It matched alignedSENSE performance while requiring only 20% of the computational time. All evaluated CAIPI sampling variants enabled robust motion correction, although tradeoffs were observed between through-plane blurring and SNR performance. The tag-control (T/C) inner loop acquisition yielded better motion robustness across all quantitative metrics. Conclusion: Self-navigated inter-shot motion correction using CAIPI sampling and a T/C inner loop for segmented 3D-GRASE ASL can improve image quality and motion robustness.
Open AccessInter-shot Motion Correction of Segmented 3D-GRASE ASL Perfusion Imaging with Self-Navigation and CAIPI
Purpose: Segmented 3D Gradient and Spin Echo (GRASE) is commonly used in Arterial Spin Labeling (ASL) perfusion imaging. However, it is vulnerable to inter-shot motion, leading to subtraction errors that cannot be corrected. We developed a retrospective self-navigated inter-shot motion correction method for segmented 3D-GRASE ASL imaging with Controlled Aliasing in Parallel Imaging (CAIPI). Methods: Multiple shots, each uniformly covering k-space at distinct sample locations, allow a self-navigator image to be reconstructed using SENSE for each shot. Rigid-body motion estimation across the self-navigators is incorporated into a motion-compensated forward model for image reconstruction. To support self-navigation, two CAIPI-sampled segmented 3D-GRASE trajectories that ensure full k-space coverage were explored for point spread function (PSF) profiles and g-factor effects. Our approach was evaluated against conventional inter-volume registration and a previously proposed method, alignedSENSE. Additionally, we compared tag-control interleaving strategies to assess their impact on motion robustness in five healthy volunteers with instructed head motion. Results: Our method effectively reduced motion artifacts and outperformed conventional inter-volume correction by 12.3% in correlation coefficient, 4.5% in Structural Similarity Index Measure (SSIM), and 40.1% in temporal SNR. It matched alignedSENSE performance while requiring only 20% of the computational time. All evaluated CAIPI sampling variants enabled robust motion correction, although tradeoffs were observed between through-plane blurring and SNR performance. The tag-control (T/C) inner loop acquisition yielded better motion robustness across all quantitative metrics. Conclusion: Self-navigated inter-shot motion correction using CAIPI sampling and a T/C inner loop for segmented 3D-GRASE ASL can improve image quality and motion robustness.
- Open Access
- 15 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 787-802
Combined angiography and perfusion using radial imaging and arterial spin labeling with structural contrast
Purpose: To develop a non‐contrast MRI method for the simultaneous acquisition of time‐resolved 3D angiographic, perfusion, and multi‐contrast T 1 ‐weighted structural brain images in a single 6 min acquisition. Methods: The proposed combined angiography and perfusion using radial imaging and arterial spin labeling with structural contrast (CAPRIA+S) pulse sequence uses pseudocontinuous arterial spin labeling to label inflowing blood, an inversion pulse to provide background suppression and T 1 ‐weighted contrast, and a continuous 3D golden ratio spoiled gradient echo readout. Label‐control subtraction isolates the blood signal which can be flexibly reconstructed at high/low spatiotemporal resolution for angiography/perfusion imaging. The mean signal retains the static tissue, allowing T 1 ‐weighted structural images to be reconstructed at different effective TIs. CAPRIA+S was compared with conventional time‐of‐flight angiography, 3D‐gradient and spin echo pseudocontinuous arterial spin labeling perfusion imaging, and MPRAGE structural imaging (10 min total) in healthy volunteers. Results: CAPRIA+S gave improved distal vessel visibility and fewer artifacts than time‐of‐flight angiography, while also providing dynamic information, with blood transit time and dispersion maps. CAPRIA+S perfusion images were comparable to 3D‐gradient and spin echo data but without through‐slice blurring or artifacts in inferior brain regions. Comparable quantitative cerebral blood flow maps were produced, with CAPRIA+S being significantly more repeatable. Structural CAPRIA+S images were comparable to MPRAGE but also yielded a range of T 1 ‐weighted contrasts and allowed quantitative T 1 maps to be estimated. Conclusion: CAPRIA+S is an efficient single acquisition to provide intrinsically co‐registered quantitative information about brain blood flow and structure that has considerable advantages over conventional methods.
- 15 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 787-802
Open AccessCombined angiography and perfusion using radial imaging and arterial spin labeling with structural contrast
Purpose: To develop a non‐contrast MRI method for the simultaneous acquisition of time‐resolved 3D angiographic, perfusion, and multi‐contrast T 1 ‐weighted structural brain images in a single 6 min acquisition. Methods: The proposed combined angiography and perfusion using radial imaging and arterial spin labeling with structural contrast (CAPRIA+S) pulse sequence uses pseudocontinuous arterial spin labeling to label inflowing blood, an inversion pulse to provide background suppression and T 1 ‐weighted contrast, and a continuous 3D golden ratio spoiled gradient echo readout. Label‐control subtraction isolates the blood signal which can be flexibly reconstructed at high/low spatiotemporal resolution for angiography/perfusion imaging. The mean signal retains the static tissue, allowing T 1 ‐weighted structural images to be reconstructed at different effective TIs. CAPRIA+S was compared with conventional time‐of‐flight angiography, 3D‐gradient and spin echo pseudocontinuous arterial spin labeling perfusion imaging, and MPRAGE structural imaging (10 min total) in healthy volunteers. Results: CAPRIA+S gave improved distal vessel visibility and fewer artifacts than time‐of‐flight angiography, while also providing dynamic information, with blood transit time and dispersion maps. CAPRIA+S perfusion images were comparable to 3D‐gradient and spin echo data but without through‐slice blurring or artifacts in inferior brain regions. Comparable quantitative cerebral blood flow maps were produced, with CAPRIA+S being significantly more repeatable. Structural CAPRIA+S images were comparable to MPRAGE but also yielded a range of T 1 ‐weighted contrasts and allowed quantitative T 1 maps to be estimated. Conclusion: CAPRIA+S is an efficient single acquisition to provide intrinsically co‐registered quantitative information about brain blood flow and structure that has considerable advantages over conventional methods.
- Open Access
MOdulation-Guided ENcoding (MOGEN) Scheme for Vessel-Encoded Arterial Spin Labeling
Vessel-encoded arterial spin labeling (VEASL) enables simultaneous, non-contrast imaging of multiple vascular territories that is useful for differential diagnosis and treatment monitoring of cerebrovascular diseases. However, the existing encoding methods are either signal-to-noise ratio (SNR) inefficient or requiring the spatial modulation to approximate a cosine function. To address these limitations, we developed a MOdulation-Guided ENcoding (MOGEN) scheme that directly exploits the spatial modulation pattern to obtain SNR-efficient encoding matrix. Simulation studies demonstrated that MOGEN achieves significantly higher theoretical SNR efficiency than previous methods across both four-and six-artery configurations. In healthy volunteers, MOGEN improved in vivo SNR by approximately 15% and provided more robust vessel decoding, particularly when the spatial modulation deviated from the cosine profile. In patients with Moyamoya disease, MOGEN enabled reliable visualization of collateral pathways even when scan time was reduced to ∼5 minutes for six arteries. Furthermore, by incorporating vessel size information and ensuring sharp label/control transitions, MOGEN enhanced single-artery selectivity in vessel-encoded angiography. We also demonstrated that a straightforward approach of off-resonance correction for VEASL at ultra-high field was feasible by using MOGEN.
Open AccessMOdulation-Guided ENcoding (MOGEN) Scheme for Vessel-Encoded Arterial Spin Labeling
Vessel-encoded arterial spin labeling (VEASL) enables simultaneous, non-contrast imaging of multiple vascular territories that is useful for differential diagnosis and treatment monitoring of cerebrovascular diseases. However, the existing encoding methods are either signal-to-noise ratio (SNR) inefficient or requiring the spatial modulation to approximate a cosine function. To address these limitations, we developed a MOdulation-Guided ENcoding (MOGEN) scheme that directly exploits the spatial modulation pattern to obtain SNR-efficient encoding matrix. Simulation studies demonstrated that MOGEN achieves significantly higher theoretical SNR efficiency than previous methods across both four-and six-artery configurations. In healthy volunteers, MOGEN improved in vivo SNR by approximately 15% and provided more robust vessel decoding, particularly when the spatial modulation deviated from the cosine profile. In patients with Moyamoya disease, MOGEN enabled reliable visualization of collateral pathways even when scan time was reduced to ∼5 minutes for six arteries. Furthermore, by incorporating vessel size information and ensuring sharp label/control transitions, MOGEN enhanced single-artery selectivity in vessel-encoded angiography. We also demonstrated that a straightforward approach of off-resonance correction for VEASL at ultra-high field was feasible by using MOGEN.
- Open Access
- 1 July 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1415-1431
Achieving robust labeling above the circle of Willis with vessel‐encoded arterial spin labeling
Purpose: To improve the robustness of noninvasive vessel‐selective perfusion imaging and angiography using vessel‐encoded arterial spin labeling (VEASL) when applied to complex vascular geometries, such as above the circle of Willis (CoW) in the brain. Methods: Our proposed improved optimized encoding scheme (IOES) better accounts for vascular geometry and the VEASL encoding process, leading to more SNR‐efficient encodings than previous approaches. Pseudo‐continuous arterial spin labeling (PCASL) parameters were optimized for a thinner labeling region, allowing tortuous vessels to be more accurately treated as single points within the labeling plane. Our optimized approach was compared to the original OES method above the CoW in healthy volunteers, with preliminary application in two Moyamoya patients. Results: In simulation, the IOES improved SNR efficiency by approximately 10% and used longer wavelength encodings that are less sensitive to subject motion. The effective labeling thickness was reduced using optimized PCASL parameters, which maintained high labeling efficiency. In healthy volunteers, these improvements allowed for the separation of at least nine arteries and their downstream tissues, with more accurate vessel decoding and closer alignment between the measured VEASL signal modulation and the encoding design. Vascular territories consistent with angiography were found in the Moyamoya patients. Conclusions: Combining IOES with optimized PCASL parameters, the vessel‐decoding efficacy in a region with complex vascular geometry above the CoW was improved. The automated encoding design process and scan times under 6 min make it feasible to observe flow patterns above the CoW in clinical settings, particularly for studies of collateral circulation.
- 1 July 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1415-1431
Open AccessAchieving robust labeling above the circle of Willis with vessel‐encoded arterial spin labeling
Purpose: To improve the robustness of noninvasive vessel‐selective perfusion imaging and angiography using vessel‐encoded arterial spin labeling (VEASL) when applied to complex vascular geometries, such as above the circle of Willis (CoW) in the brain. Methods: Our proposed improved optimized encoding scheme (IOES) better accounts for vascular geometry and the VEASL encoding process, leading to more SNR‐efficient encodings than previous approaches. Pseudo‐continuous arterial spin labeling (PCASL) parameters were optimized for a thinner labeling region, allowing tortuous vessels to be more accurately treated as single points within the labeling plane. Our optimized approach was compared to the original OES method above the CoW in healthy volunteers, with preliminary application in two Moyamoya patients. Results: In simulation, the IOES improved SNR efficiency by approximately 10% and used longer wavelength encodings that are less sensitive to subject motion. The effective labeling thickness was reduced using optimized PCASL parameters, which maintained high labeling efficiency. In healthy volunteers, these improvements allowed for the separation of at least nine arteries and their downstream tissues, with more accurate vessel decoding and closer alignment between the measured VEASL signal modulation and the encoding design. Vascular territories consistent with angiography were found in the Moyamoya patients. Conclusions: Combining IOES with optimized PCASL parameters, the vessel‐decoding efficacy in a region with complex vascular geometry above the CoW was improved. The automated encoding design process and scan times under 6 min make it feasible to observe flow patterns above the CoW in clinical settings, particularly for studies of collateral circulation.
- Open Access
- 28 May 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (3) , 965-981
SNR‐efficient whole‐brain pseudo‐continuous arterial spin labeling perfusion imaging at 7 T
Purpose: To optimize pseudo‐continuous arterial spin labeling (PCASL) parameters to maximize SNR efficiency for RF power constrained whole brain perfusion imaging at 7 T.Methods: We used Bloch simulations of pulsatile laminar flow to optimize the PCASL parameters for maximum SNR efficiency, balancing labeling efficiency and total RF power. The optimization included adjusting the inter‐RF pulse spacing (TRPCASL), mean B1+ (B1+ave), slice‐selective gradient amplitude (Gmax), and mean gradient amplitude (Gave). In vivo data were acquired from six volunteers at 7 T to validate the optimized parameters. Dynamic B0‐shimming and flip angle adjustments were used to avoid needing to make the PCASL parameters robust to B0/B1+ variations.Results: The optimized PCASL parameters achieved a significant (3.3×) reduction in RF power while maintaining high labeling efficiency. This allowed for longer label durations and minimized deadtime, resulting in a 118% improvement in SNR efficiency in vivo compared to a previously proposed protocol. Additionally, the static tissue response was improved, reducing the required distance between labeling plane and imaging volume.Conclusion: These optimized PCASL parameters provide a robust and efficient approach for whole brain perfusion imaging at 7 T, with significant improvements in SNR efficiency and reduced specific absorption rate burden.
- 28 May 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (3) , 965-981
Open AccessSNR‐efficient whole‐brain pseudo‐continuous arterial spin labeling perfusion imaging at 7 T
Purpose: To optimize pseudo‐continuous arterial spin labeling (PCASL) parameters to maximize SNR efficiency for RF power constrained whole brain perfusion imaging at 7 T.Methods: We used Bloch simulations of pulsatile laminar flow to optimize the PCASL parameters for maximum SNR efficiency, balancing labeling efficiency and total RF power. The optimization included adjusting the inter‐RF pulse spacing (TRPCASL), mean B1+ (B1+ave), slice‐selective gradient amplitude (Gmax), and mean gradient amplitude (Gave). In vivo data were acquired from six volunteers at 7 T to validate the optimized parameters. Dynamic B0‐shimming and flip angle adjustments were used to avoid needing to make the PCASL parameters robust to B0/B1+ variations.Results: The optimized PCASL parameters achieved a significant (3.3×) reduction in RF power while maintaining high labeling efficiency. This allowed for longer label durations and minimized deadtime, resulting in a 118% improvement in SNR efficiency in vivo compared to a previously proposed protocol. Additionally, the static tissue response was improved, reducing the required distance between labeling plane and imaging volume.Conclusion: These optimized PCASL parameters provide a robust and efficient approach for whole brain perfusion imaging at 7 T, with significant improvements in SNR efficiency and reduced specific absorption rate burden.
- Open Access
Combined Angiographic, Structural and Perfusion Radial Imaging using Arterial Spin Labeling
Purpose To develop a non-contrast MRI method for the simultaneous acquisition of time-resolved 3D angiographic, perfusion and multi-contrast T1-weighted structural brain images in a single six-minute acquisition. Methods The proposed Combined Angiographic, Structural and Perfusion Radial Imaging using Arterial Spin Labeling (CASPRIA) pulse sequence uses pseudocontinuous arterial spin labeling (PCASL) to label inflowing blood, an inversion pulse to provide background suppression and T1-weighted contrast, and a continuous 3D golden ratio spoiled gradient echo readout. Label-control subtraction isolates the blood signal and can be flexibly reconstructed at high/low spatiotemporal resolution for angiography/perfusion imaging. The mean signal retains the static tissue, allowing T1-weighted structural images to be reconstructed at different effective inversion times. CASPRIA was compared with conventional time-of-flight (TOF) angiography, 3D-gradient and spin echo (3D-GRASE) PCASL perfusion imaging and magnetization-prepared rapid gradient echo (MP-RAGE) structural imaging (10 minutes total) in healthy volunteers. Results CASPRIA gave improved distal vessel visibility and fewer artefacts than TOF angiography, whilst also providing dynamic information, with blood transit time and dispersion maps. CASPRIA perfusion images were comparable to 3D-GRASE data, but without through-slice blurring or artefacts in inferior brain regions. Comparable quantitative cerebral blood flow maps were produced, with CASPRIA being significantly more repeatable. Structural CASPRIA images were comparable to MP-RAGE, but also yielded a range of T1-weighted contrasts and allowed quantitative T1 maps to be estimated. Conclusion CASPRIA is an efficient single acquisition to provide intrinsically co-registered quantitative information about brain blood flow and structure that has considerable advantages over conventional methods.
Open AccessCombined Angiographic, Structural and Perfusion Radial Imaging using Arterial Spin Labeling
Purpose To develop a non-contrast MRI method for the simultaneous acquisition of time-resolved 3D angiographic, perfusion and multi-contrast T1-weighted structural brain images in a single six-minute acquisition. Methods The proposed Combined Angiographic, Structural and Perfusion Radial Imaging using Arterial Spin Labeling (CASPRIA) pulse sequence uses pseudocontinuous arterial spin labeling (PCASL) to label inflowing blood, an inversion pulse to provide background suppression and T1-weighted contrast, and a continuous 3D golden ratio spoiled gradient echo readout. Label-control subtraction isolates the blood signal and can be flexibly reconstructed at high/low spatiotemporal resolution for angiography/perfusion imaging. The mean signal retains the static tissue, allowing T1-weighted structural images to be reconstructed at different effective inversion times. CASPRIA was compared with conventional time-of-flight (TOF) angiography, 3D-gradient and spin echo (3D-GRASE) PCASL perfusion imaging and magnetization-prepared rapid gradient echo (MP-RAGE) structural imaging (10 minutes total) in healthy volunteers. Results CASPRIA gave improved distal vessel visibility and fewer artefacts than TOF angiography, whilst also providing dynamic information, with blood transit time and dispersion maps. CASPRIA perfusion images were comparable to 3D-GRASE data, but without through-slice blurring or artefacts in inferior brain regions. Comparable quantitative cerebral blood flow maps were produced, with CASPRIA being significantly more repeatable. Structural CASPRIA images were comparable to MP-RAGE, but also yielded a range of T1-weighted contrasts and allowed quantitative T1 maps to be estimated. Conclusion CASPRIA is an efficient single acquisition to provide intrinsically co-registered quantitative information about brain blood flow and structure that has considerable advantages over conventional methods.
- Open Access
- 29 December 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (5) , 1924-1941
Ultra‐high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction
Purpose: To achieve ultra‐high temporal resolution non‐contrast 4D angiography with improved spatiotemporal fidelity.Methods: Continuous data acquisition using 3D golden‐angle sampling following an arterial spin labeling preparation allows for flexibly reconstructing 4D dynamic angiograms at arbitrary temporal resolutions. However, k‐space data is often temporally “binned” before image reconstruction, negatively affecting spatiotemporal fidelity and limiting temporal resolution. In this work, a subspace was extracted by linearly compressing a dictionary constructed from simulated curves of an angiographic kinetic model. The subspace was used to represent and reconstruct the voxelwise signal timecourse at the same temporal resolution as the data acquisition without temporal binning. Physiological parameters were estimated from the resulting images using a Bayesian fitting approach. A group of eight healthy subjects were scanned and the in vivo results reconstructed by different methods were compared. Because of the difficulty of obtaining ground truth 4D angiograms with ultra‐high temporal resolution, the in vivo results were cross‐validated with numerical simulations.Results: The proposed method enables 4D time‐resolved angiography with much higher temporal resolution (14.7 ms) than previously reported (˜50 ms) while maintaining high spatial resolution (1.1 mm isotropic). Blood flow dynamics were depicted in greater detail, thin vessel visibility was improved, and the estimated physiological parameters also exhibited more realistic spatial patterns with the proposed method.Conclusion: Incorporating a subspace compressed kinetic model into the reconstruction of 4D ASL angiograms notably improved the temporal resolution and spatiotemporal fidelity, which was subsequently beneficial for accurate physiological modeling.
- 29 December 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (5) , 1924-1941
Open AccessUltra‐high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction
Purpose: To achieve ultra‐high temporal resolution non‐contrast 4D angiography with improved spatiotemporal fidelity.Methods: Continuous data acquisition using 3D golden‐angle sampling following an arterial spin labeling preparation allows for flexibly reconstructing 4D dynamic angiograms at arbitrary temporal resolutions. However, k‐space data is often temporally “binned” before image reconstruction, negatively affecting spatiotemporal fidelity and limiting temporal resolution. In this work, a subspace was extracted by linearly compressing a dictionary constructed from simulated curves of an angiographic kinetic model. The subspace was used to represent and reconstruct the voxelwise signal timecourse at the same temporal resolution as the data acquisition without temporal binning. Physiological parameters were estimated from the resulting images using a Bayesian fitting approach. A group of eight healthy subjects were scanned and the in vivo results reconstructed by different methods were compared. Because of the difficulty of obtaining ground truth 4D angiograms with ultra‐high temporal resolution, the in vivo results were cross‐validated with numerical simulations.Results: The proposed method enables 4D time‐resolved angiography with much higher temporal resolution (14.7 ms) than previously reported (˜50 ms) while maintaining high spatial resolution (1.1 mm isotropic). Blood flow dynamics were depicted in greater detail, thin vessel visibility was improved, and the estimated physiological parameters also exhibited more realistic spatial patterns with the proposed method.Conclusion: Incorporating a subspace compressed kinetic model into the reconstruction of 4D ASL angiograms notably improved the temporal resolution and spatiotemporal fidelity, which was subsequently beneficial for accurate physiological modeling.
- Open Access
- 6 December 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (4) , 1674-1689
Dynamic B 0 field shimming for improving pseudo‐continuous arterial spin labeling at 7 T
Purpose: B 0 field inhomogeneity within the brain‐feeding arteries is a major issue for pseudo‐continuous arterial spin labeling (PCASL) at 7 T because it reduces the labeling efficiency and leads to a loss of perfusion signal. This study aimed to develop a vessel‐specific dynamic B 0 field shimming method for 7 T PCASL to improve the labeling efficiency by correcting off‐resonance within the arteries in the labeling region. Methods: We implemented a PCASL sequence with dynamic B 0 shimming at 7 T that compensates for B 0 field offsets in the brain‐feeding arteries by updating linear shimming terms and adding a phase increment to the PCASL RF pulses. Rapidly acquired vessel‐specific B 0 field maps were used to calculate dynamic B 0 shimming parameters. We evaluated both 2D and 3D variants of our method, comparing their performance against the established global frequency offset and optimal encoding scheme‐based corrections. Cerebral blood flow (CBF) maps were quantified before and after corrections, and CBF values from different methods were compared across the whole brain, white matter, and gray matter regions. Results: All off‐resonance correction methods significantly recovered perfusion signals across the brain. The proposed vessel‐specific dynamic B 0 shimming method improved the labeling efficiency while maintaining optimal static shimming in the imaging region. Perfusion‐weighted images demonstrated the superiority of the 3D dynamic B 0 shimming method compared to global or 2D‐based correction approaches. CBF analysis revealed that 3D dynamic B 0 shimming significantly increased CBF values relative to the other methods. Conclusion: Our proposed dynamic B 0 shimming method offers a significant advancement in PCASL robustness and effectiveness, enabling full utilization of 7 T ASL high sensitivity and spatial resolution.
- 6 December 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (4) , 1674-1689
Open AccessDynamic B 0 field shimming for improving pseudo‐continuous arterial spin labeling at 7 T
Purpose: B 0 field inhomogeneity within the brain‐feeding arteries is a major issue for pseudo‐continuous arterial spin labeling (PCASL) at 7 T because it reduces the labeling efficiency and leads to a loss of perfusion signal. This study aimed to develop a vessel‐specific dynamic B 0 field shimming method for 7 T PCASL to improve the labeling efficiency by correcting off‐resonance within the arteries in the labeling region. Methods: We implemented a PCASL sequence with dynamic B 0 shimming at 7 T that compensates for B 0 field offsets in the brain‐feeding arteries by updating linear shimming terms and adding a phase increment to the PCASL RF pulses. Rapidly acquired vessel‐specific B 0 field maps were used to calculate dynamic B 0 shimming parameters. We evaluated both 2D and 3D variants of our method, comparing their performance against the established global frequency offset and optimal encoding scheme‐based corrections. Cerebral blood flow (CBF) maps were quantified before and after corrections, and CBF values from different methods were compared across the whole brain, white matter, and gray matter regions. Results: All off‐resonance correction methods significantly recovered perfusion signals across the brain. The proposed vessel‐specific dynamic B 0 shimming method improved the labeling efficiency while maintaining optimal static shimming in the imaging region. Perfusion‐weighted images demonstrated the superiority of the 3D dynamic B 0 shimming method compared to global or 2D‐based correction approaches. CBF analysis revealed that 3D dynamic B 0 shimming significantly increased CBF values relative to the other methods. Conclusion: Our proposed dynamic B 0 shimming method offers a significant advancement in PCASL robustness and effectiveness, enabling full utilization of 7 T ASL high sensitivity and spatial resolution.