  • Experiences Developing a Protocol for Accelerated Partial Breast Irradiation

    by Nina Lin, Alison Gray, Megan Berry, Rebecca Bartlett, Isabella Franji, Philip Vial, Amy Walker, Kimberley Nguyen

  • Commissioning of a RayStation structure template for the iBEAM evo Couchtop

    by Vaughan Moutrie, Amy Walker

    Accurate radiotherapy treatment planning requires attenuation through the treatment couch to be accounted for in dose calculation. This is commonly performed by using contouring tools to add a virtual structure in the shape of the treatment couch and assigning the preferred absorption properties. The RayStation treatment planning system (TPS) allows users to assign a material that comprises both an elemental structure and a physical density. The selection of such parameters should be made so that modelled attenuation through the couch closely matches measured data. When these measurements involve the use of plastic phantoms and rotational beams, the validity of the data is dependent upon aspects of TPS and linear accelerator performance that can be difficult to quantify. A fundamental measure of couch attenuation using an ionisation chamber in water and perpendicular beam geometry that required no gantry movement was implemented to eliminate the identified uncertainties. This data was used to determine the combination of elemental composition and density assigned to a modelled couch structure that provided the most accurate representation of beam attenuation in this simple geometry. The preferred material was then validated using a cylindrical phantom and rotational beams. The findings were equivalent between the static gantry with water phantom and rotating gantry with cylindrical phantom. Of the elemental compositions investigated, it was possible to achieve suitable agreement with the measured data for each option provided the density was optimised. Choice of the elemental composition was not observed to be an important factor in achieving a good model.


  • PO-1731 Evaluation of materials suitable for anthropomorphic multimodality (CT/MRI) phantoms for RT purposes

    by M. Alzahrani, D. Broadbent, I. Teh, B. Al-Qaisieh, A. Walker, R. Lamb, R. Speight

  • Open Access

    Repeatability of radiotherapy dose-painting prescriptions derived from a multiparametric magnetic resonance imaging model of glioblastoma infiltration

    by Caterina Brighi, Niels Verburg, Eng-Siew Koh, Amy Walker, Cathy Chen, Sugendran Pillay, Philip C. de Witt Hamer, Farhannah Aly, Lois C. Holloway, Paul J. Keall, et al.


  • Open Access

    MRI geometric distortion: Impact on tangential whole‐breast IMRT

    by Amy Walker, Peter Metcalfe, Gary Liney, Vikneswary Batumalai, Kylie Dundas, Carri Glide‐Hurst, Geoff P Delaney, Miriam Boxer, Mei Ling Yap, Jason Dowling, et al.

    The purpose of this study was to determine the impact of magnetic resonance imaging (MRI) geometric distortions when using MRI for target delineation and planning for whole-breast, intensity-modulated radiotherapy (IMRT). Residual system distortions and combined systematic and patient-induced distortions are considered. This retrospective study investigated 18 patients who underwent whole-breast external beam radiotherapy, where both CT and MRIs were acquired for treatment planning. Distortion phantoms were imaged on two MRI systems, dedicated to radiotherapy planning (a wide, closed-bore 3T and an open-bore 1T). Patient scans were acquired on the 3T system. To simulate MRI-based planning, distortion maps representing residual system distortions were generated via deformable registration between phantom CT and MRIs. Patient CT images and structures were altered to match the residual system distortion measured by the phantoms on each scanner. The patient CTs were also registered to the corresponding patient MRI scans, to assess patient and residual system effects. Tangential IMRT plans were generated and optimized on each resulting CT dataset, then propagated to the original patient CT space. The resulting dose distributions were then evaluated with respect to the standard clinically acceptable DVH and visual assessment criteria. Maximum residual systematic distortion was measured to be 7.9 mm ( 95%<4.7mm ) and 11.9 mm ( 95%<4.6mm ) for the 3T and 1T scanners, respectively, which did not result in clinically unacceptable plans. Eight of the plans accounting for patient and systematic distortions were deemed clinically unacceptable when assessed on the original CT. For these plans, the mean difference in PTV V95 (volume receiving 95% prescription dose) was 0.13?2.51% and ?0.73?1.93% for right- and left-sided patients, respectively. Residual system distortions alone had minimal impact on the dosimetry for the two scanners investigated. The combination of MRI systematic and patient-related distortions can result in unacceptable dosimetry for whole-breast IMRT, a potential issue when considering MRI-only radiotherapy treatment planning. PACS number(s): 87.61.-c, 87.57.cp, 87.57.nj, 87.55.D-


    • 8 September 2016
      • Vol. 17  (5)

    MRI geometric distortion: Impact on tangential whole-breast IMRT.

    by Amy Walker, Peter Metcalfe, Gary Liney, Vikneswary Batumalai, Kylie Dundas, Carri Glide-Hurst, Geoff P Delaney, Miriam Boxer, Mei Ling Yap, Jason Dowling, et al.

  • Continuous table acquisition MRI for radiotherapy treatment planning: Distortion assessment with a new extended 3D volumetric phantom

    by Amy Walker, Gary Liney, Lois Holloway, Jason Dowling, David Rivest‐Henault, Peter Metcalfe

    Purpose: Accurate geometry is required for radiotherapy treatment planning (RTP). When considering the use of magnetic resonance imaging (MRI) for RTP, geometric distortions observed in the acquired images should be considered. While scanner technology and vendor supplied correction algorithms provide some correction, large distortions are still present in images, even when considering considerably smaller scan lengths than those typically acquired with CT in conventional RTP. This study investigates MRI acquisition with a moving table compared with static scans for potential geometric benefits for RTP.Methods: A full field of view (FOV) phantom (diameter 500 mm; length 513 mm) was developed for measuring geometric distortions in MR images over volumes pertinent to RTP. The phantom consisted of layers of refined plastic within which vitamin E capsules were inserted. The phantom was scanned on CT to provide the geometric gold standard and on MRI, with differences in capsule location determining the distortion. MRI images were acquired with two techniques. For the first method, standard static table acquisitions were considered. Both 2D and 3D acquisition techniques were investigated. With the second technique, images were acquired with a moving table. The same sequence was acquired with a static table and then with table speeds of 1.1 mm/s and 2 mm/s. All of the MR images acquired were registered to the CT dataset using a deformable B‐spline registration with the resulting deformation fields providing the distortion information for each acquisition.Results: MR images acquired with the moving table enabled imaging of the whole phantom length while images acquired with a static table were only able to image 50%–70% of the phantom length of 513 mm. Maximum distortion values were reduced across a larger volume when imaging with a moving table. Increased table speed resulted in a larger contribution of distortion from gradient nonlinearities in the through‐plane direction and an increased blurring of capsule images, resulting in an apparent capsule volume increase by up to 170% in extreme axial FOV regions. Blurring increased with table speed and in the central regions of the phantom, geometric distortion was less for static table acquisitions compared to a table speed of 2 mm/s over the same volume. Overall, the best geometric accuracy was achieved with a table speed of 1.1 mm/s.Conclusions: The phantom designed enables full FOV imaging for distortion assessment for the purposes of RTP. MRI acquisition with a moving table extends the imaging volume in the z direction with reduced distortions which could be useful particularly if considering MR‐only planning. If utilizing MR images to provide additional soft tissue information to the planning CT, standard acquisition sequences over a smaller volume would avoid introducing additional blurring or distortions from the through‐plane table movement.


  • A Twist1-MLL-WDR5-HOTTIP Complex Regulates HOXA9 Chromatin to Facilitate Metastasis of Prostate Cancer

    by P.T. Tran, R. Gajula, R. Williams, R. Malek, K. Nugent, A. Walker, S. Chettiar, H. Wang, K. Taparra, J. Cades, et al.


  • MRI distortion: considerations for MRI based radiotherapy treatment planning

    by Amy Walker, Gary Liney, Peter Metcalfe, Lois Holloway

    Distortion in magnetic resonance images needs to be taken into account for the purposes of radiotherapy treatment planning (RTP). A commercial MRI grid phantom was scanned on four different MRI scanners with multiple sequences to assess variations in the geometric distortion. The distortions present across the field of view were then determined. The effect of varying bandwidth on image distortion and signal to noise was also investigated. Distortion maps were created and these were compared to the location of patient anatomy within the scanner bore to estimate the magnitude and distribution of distortions located within specific clinical regions. Distortion magnitude and patterns varied between MRI sequence protocols and scanners. The magnitude of the distortions increased with increasing distance from the isocentre of the scanner within a 2D imaging plane. Average distortion across the phantom generally remained below 2.0 mm, although towards the edge of the phantom for a turbo spin echo sequence, the distortion increased to a maximum value of 4.1 mm. Application of correction algorithms supplied by each vendor reduced but did not completely remove distortions. Increasing the bandwidth of the acquisition sequence decreased the amount of distortion at the expense of a reduction in signal-to-noise ratio of 13.5 across measured bandwidths. Imaging protocol parameters including bandwidth, slice thickness and phase encoding direction, should be noted for distortion investigations in RTP since each can influence the distortion. The magnitude of distortion varies across different clinical sites.