Peter Maximilian Kadletz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peter Maximilian Kadletz has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Robin Woracek
European Spallation Source ERIC, Lund, Sweden
3 shared publications - Anton S. Tremsin
University of California, Berkeley
2 shared publications - Kalliopi Kanaki
Department of Nuclear Sciences and Applications, IAEA, Nuclear Science and Instrumentation Laboratory, Physics Section, Division of Physical and Chemical Sciences, Vienna International Center, Vienna, Austria
2 shared publications - Lorenz Gubler
Paul Scherrer Institut
2 shared publications Mateusz Zlobinski
2 shared publications- Vendula Maulerova
European Spallation Source ERIC, Lund, Sweden
2 shared publications
Latest Publications
- Open Access
- 15 July 2023
- Published by Elsevier in Materials Today Advances
- Vol. 19
Spectroscopic neutron imaging for resolving hydrogen dynamics changes in battery electrolytes
- 15 July 2023
- Published by Elsevier in Materials Today Advances
- Vol. 19
Open AccessSpectroscopic neutron imaging for resolving hydrogen dynamics changes in battery electrolytes
- 2 March 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 19 (3) , 034005
Revisiting Neutron Propagation-Based Phase-Contrast Imaging and Tomography: Use of Phase Retrieval to Amplify the Effective Degree of Brilliance
Propagation-based neutron phase-contrast tomography is demonstrated using the ISIS pulsed spallation source. The proof-of-concept tomogram with a Paganin-type phase-retrieval filter applied exhibits an effective net boost of in the signal-to-noise ratio as compared with an attenuation-based tomogram, implying a boost in the effective degree of neutron brilliance of over 2 orders of magnitude. This comparison is for phase retrieval versus conventional absorption with no additional collimation in place. We provide expressions for the optimal phase-contrast geometry as well as conditions for the validity of the method. The underpinning theory is derived under the assumption of the sample being composed of a single material. The effective boost in brilliance may be employed to give reduced acquisition time, or may instead be used to keep exposure times fixed while improving the measured contrast.- 2 March 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 19 (3) , 034005
Revisiting Neutron Propagation-Based Phase-Contrast Imaging and Tomography: Use of Phase Retrieval to Amplify the Effective Degree of Brilliance
Propagation-based neutron phase-contrast tomography is demonstrated using the ISIS pulsed spallation source. The proof-of-concept tomogram with a Paganin-type phase-retrieval filter applied exhibits an effective net boost of in the signal-to-noise ratio as compared with an attenuation-based tomogram, implying a boost in the effective degree of neutron brilliance of over 2 orders of magnitude. This comparison is for phase retrieval versus conventional absorption with no additional collimation in place. We provide expressions for the optimal phase-contrast geometry as well as conditions for the validity of the method. The underpinning theory is derived under the assumption of the sample being composed of a single material. The effective boost in brilliance may be employed to give reduced acquisition time, or may instead be used to keep exposure times fixed while improving the measured contrast.- Open Access
- 25 October 2022
- Published by Springer Nature in EPJ Techniques and Instrumentation
- Vol. 9 (1) , 1-15
First evaluation of a novel ionisation chamber for thermal neutron beam monitoring
The European Spallation Source ERIC (ESS), currently under construction in Lund, Sweden is a facility established to deliver the highest integrated neutron flux originating from a pulsed source with the aim of supporting an initial fifteen neutron instruments for cutting edge science experiments. This in turn requires reliable monitoring at complex neutron beam lines: in particular, linearity, timing capability, adaptability of the design for various flux ranges (dynamic range) and sensitivity to neutrons within the range of 0.6-10Å are expected from the neutron beam monitors to be installed at the ESS beam lines. Additionally, operational stability and low attenuation are also desirable characteristics for such neutron beam monitoring. A prototype neutron beam monitor based on the ionisation chamber principle and a boron converter, designed by CDT CASCADE Detector Technologies GmbH and ESS, has been investigated at the BER-II research reactor of Helmholtz Zentrum Berlin (HZB). The effort to design and investigate a thermal neutron ionisation beam monitor was initiated by adapting the concept of ionisation chambers previously known elsewhere. So far all the characterised neutron beam monitors discriminate neutron hits on a discrete event basis (pulse mode), whereas the beam monitor prototype introduced in this paper estimates the total flux as a function of current (current mode). While most other neutron beam monitoring devices and detectors rely upon a signal amplifying gain stage, the ionisation chamber operates without any gain and is consequently robust against typical detector ageing effects that compromise the sensitivity over time. The initial tests were performed at the ESS V20 test beam line under realistic conditions resembling those of the future pulses of ESS. The linearity is demonstrated for 3Å pulses in the flux range of 2-3 × 105 n/s/cm2 and for white pulses (0.6-10Å) in the range of 1-5 × 106 n/s/cm2. The timing behaviour resembles the data previously recorded at the V20 beam lines. This novel implementation of a neutron sensitive ionisation chamber shows great promise for beam monitoring and diagnostics at ESS. As the ionisation beam monitor itself is an entirely passive device, it is adequately robust to be employed in areas of high irradiation where no regular servicing or maintenance can be provided.
- 25 October 2022
- Published by Springer Nature in EPJ Techniques and Instrumentation
- Vol. 9 (1) , 1-15
Open AccessFirst evaluation of a novel ionisation chamber for thermal neutron beam monitoring
The European Spallation Source ERIC (ESS), currently under construction in Lund, Sweden is a facility established to deliver the highest integrated neutron flux originating from a pulsed source with the aim of supporting an initial fifteen neutron instruments for cutting edge science experiments. This in turn requires reliable monitoring at complex neutron beam lines: in particular, linearity, timing capability, adaptability of the design for various flux ranges (dynamic range) and sensitivity to neutrons within the range of 0.6-10Å are expected from the neutron beam monitors to be installed at the ESS beam lines. Additionally, operational stability and low attenuation are also desirable characteristics for such neutron beam monitoring. A prototype neutron beam monitor based on the ionisation chamber principle and a boron converter, designed by CDT CASCADE Detector Technologies GmbH and ESS, has been investigated at the BER-II research reactor of Helmholtz Zentrum Berlin (HZB). The effort to design and investigate a thermal neutron ionisation beam monitor was initiated by adapting the concept of ionisation chambers previously known elsewhere. So far all the characterised neutron beam monitors discriminate neutron hits on a discrete event basis (pulse mode), whereas the beam monitor prototype introduced in this paper estimates the total flux as a function of current (current mode). While most other neutron beam monitoring devices and detectors rely upon a signal amplifying gain stage, the ionisation chamber operates without any gain and is consequently robust against typical detector ageing effects that compromise the sensitivity over time. The initial tests were performed at the ESS V20 test beam line under realistic conditions resembling those of the future pulses of ESS. The linearity is demonstrated for 3Å pulses in the flux range of 2-3 × 105 n/s/cm2 and for white pulses (0.6-10Å) in the range of 1-5 × 106 n/s/cm2. The timing behaviour resembles the data previously recorded at the V20 beam lines. This novel implementation of a neutron sensitive ionisation chamber shows great promise for beam monitoring and diagnostics at ESS. As the ionisation beam monitor itself is an entirely passive device, it is adequately robust to be employed in areas of high irradiation where no regular servicing or maintenance can be provided.
- 19 October 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-02 (1) , 128
Study of Phase Changes in Lithium-Ion Battery Electrolytes via Spectroscopic Neutron Imaging
- 19 October 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-02 (1) , 128
Study of Phase Changes in Lithium-Ion Battery Electrolytes via Spectroscopic Neutron Imaging
- Open Access
- 1 December 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (12) , 125111
Wavelength frame multiplication for reflectometry at long-pulse neutron sources
The European Spallation Source (ESS), which is under construction in Lund (Sweden), will be the next leading neutron facility with an unprecedented brilliance and novel long-pulse time structure. A long-pulse source not only provides a high time-average flux but also opens the possibility to tune the resolution by using pulse shaping choppers. Thus, an instrument can readily be operated in either a high flux or a high resolution mode. Several of the shorter instruments at the ESS will employ Wavelength Frame Multiplication (WFM) in order to enable a sufficient resolution while offering a continuous and broad wavelength range. A test beamline was operated until the end of 2019 at the research reactor in Berlin to test components and methods, including WFM, in order to prepare the new facility for the operation of neutron instruments and successful first science. We herein demonstrate the implementation of WFM for reflectometry. By selecting a short pulse mode under the same geometrical configuration, we compare and discuss the results for two reference samples. The reported experiments not only serve to prove the reliability of the WFM approach but also, for the first time, demonstrate the full instrument control, data acquisition and data reduction chain that will be implemented at the ESS.
- 1 December 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (12) , 125111
Open AccessWavelength frame multiplication for reflectometry at long-pulse neutron sources
The European Spallation Source (ESS), which is under construction in Lund (Sweden), will be the next leading neutron facility with an unprecedented brilliance and novel long-pulse time structure. A long-pulse source not only provides a high time-average flux but also opens the possibility to tune the resolution by using pulse shaping choppers. Thus, an instrument can readily be operated in either a high flux or a high resolution mode. Several of the shorter instruments at the ESS will employ Wavelength Frame Multiplication (WFM) in order to enable a sufficient resolution while offering a continuous and broad wavelength range. A test beamline was operated until the end of 2019 at the research reactor in Berlin to test components and methods, including WFM, in order to prepare the new facility for the operation of neutron instruments and successful first science. We herein demonstrate the implementation of WFM for reflectometry. By selecting a short pulse mode under the same geometrical configuration, we compare and discuss the results for two reference samples. The reported experiments not only serve to prove the reliability of the WFM approach but also, for the first time, demonstrate the full instrument control, data acquisition and data reduction chain that will be implemented at the ESS.
- Open Access
- 6 July 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (7) , 072901
Vanadium-based neutron beam monitor
A prototype quasiparasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard proportional counters is conceptualized, designed, simulated, calibrated, and commissioned. The European Spallation Source designed to deliver the highest integrated neutron flux originating from a pulsed source is currently under construction in Lund, Sweden. The effort to investigate a vanadium-based neutron beam monitor was triggered by a list of requirements for beam monitors permanently placed in the ESS neutron beams in order to provide reliable monitoring at complex beam lines: low attenuation, linear response over a wide range of neutron fluxes, near to constant efficiency for neutron wavelengths in a range of 0.6–10 Å, calibration stability and the possibility to place the system in vacuum are all desirable characteristics. The scattering-based prototype, employing a natural vanadium foil and standard proportional counters, was investigated at the V17 and V20 neutron beam lines of the Helmholtz-Zentrum in Berlin, Germany, in several different geometrical configurations of the proportional counters around the foil. Response linearity is successfully demonstrated for foil thicknesses ranging from 0.04 mm to 3.15 mm. Attenuation lower than 1% for thermal neutrons is demonstrated for the 0.04 mm and 0.125 mm foils. The geometries used for the experiment were simulated allowing for absolute flux calibration and establishing the possible range of efficiencies for various designs of the prototype. The operational flux limits for the beam monitor prototype were established as a dependency of the background radiation and prototype geometry. The herein demonstrated prototype monitors can be employed for neutron intensities ranging from .- 6 July 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (7) , 072901
Open AccessVanadium-based neutron beam monitor
A prototype quasiparasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard proportional counters is conceptualized, designed, simulated, calibrated, and commissioned. The European Spallation Source designed to deliver the highest integrated neutron flux originating from a pulsed source is currently under construction in Lund, Sweden. The effort to investigate a vanadium-based neutron beam monitor was triggered by a list of requirements for beam monitors permanently placed in the ESS neutron beams in order to provide reliable monitoring at complex beam lines: low attenuation, linear response over a wide range of neutron fluxes, near to constant efficiency for neutron wavelengths in a range of 0.6–10 Å, calibration stability and the possibility to place the system in vacuum are all desirable characteristics. The scattering-based prototype, employing a natural vanadium foil and standard proportional counters, was investigated at the V17 and V20 neutron beam lines of the Helmholtz-Zentrum in Berlin, Germany, in several different geometrical configurations of the proportional counters around the foil. Response linearity is successfully demonstrated for foil thicknesses ranging from 0.04 mm to 3.15 mm. Attenuation lower than 1% for thermal neutrons is demonstrated for the 0.04 mm and 0.125 mm foils. The geometries used for the experiment were simulated allowing for absolute flux calibration and establishing the possible range of efficiencies for various designs of the prototype. The operational flux limits for the beam monitor prototype were established as a dependency of the background radiation and prototype geometry. The herein demonstrated prototype monitors can be employed for neutron intensities ranging from . - 22 January 2018
- Published by American Chemical Society (ACS) in ACS Combinatorial Science
- Vol. 20 (3) , 137-150
Crystallographic Structure Analysis of a Ti–Ta Thin Film Materials Library Fabricated by Combinatorial Magnetron Sputtering
Ti–Ta thin films exhibit properties that are of interest for applications as microactuators and as biomedical implants. A Ti–Ta thin film materials library was deposited at T = 25 °C by magnetron sputtering employing the combinatorial approach, which led to a compositional range of Ti87Ta13 to Ti14Ta86. Subsequent high-throughput characterization methods permitted a quick and comprehensive study of the crystallographic, microstructural, and morphological properties, which strongly depend on the chemical composition. SEM investigation revealed a columnar morphology having pyramidal, sharp tips with coarser columns in the Ti-rich and finer columns in the Ta-rich region. By grazing incidence X-ray diffraction four phases were identified, from Ta-lean to Ta-rich: ω phase, α″ martensite, β phase, and a tetragonal Ta-rich phase (Ta(tetr)). The crystal structure and microstructure were analyzed by Rietveld refinement and clear trends could be determined as a function of Ta-content. The lattice correspondences between β as the parent phase and α″ and ω as derivative phases were expressed in matrix form. The β ⇌ α″ phase transition shows a discontinuity at the composition where the martensitic transformation temperatures fall below room temperature (between 34 and 38 at. % Ta) rendering it first order and confirming its martensitic nature. A short study of the α″ martensite employing the Landau theory is included for a mathematical quantification of the spontaneous lattice strain at room temperature (ϵ̂max = 22.4(6) % for pure Ti). Martensitic properties of Ti–Ta are beneficial for the development of high-temperature actuators with actuation response at transformation temperatures higher than 100 °C.
- 22 January 2018
- Published by American Chemical Society (ACS) in ACS Combinatorial Science
- Vol. 20 (3) , 137-150
Crystallographic Structure Analysis of a Ti–Ta Thin Film Materials Library Fabricated by Combinatorial Magnetron Sputtering
Ti–Ta thin films exhibit properties that are of interest for applications as microactuators and as biomedical implants. A Ti–Ta thin film materials library was deposited at T = 25 °C by magnetron sputtering employing the combinatorial approach, which led to a compositional range of Ti87Ta13 to Ti14Ta86. Subsequent high-throughput characterization methods permitted a quick and comprehensive study of the crystallographic, microstructural, and morphological properties, which strongly depend on the chemical composition. SEM investigation revealed a columnar morphology having pyramidal, sharp tips with coarser columns in the Ti-rich and finer columns in the Ta-rich region. By grazing incidence X-ray diffraction four phases were identified, from Ta-lean to Ta-rich: ω phase, α″ martensite, β phase, and a tetragonal Ta-rich phase (Ta(tetr)). The crystal structure and microstructure were analyzed by Rietveld refinement and clear trends could be determined as a function of Ta-content. The lattice correspondences between β as the parent phase and α″ and ω as derivative phases were expressed in matrix form. The β ⇌ α″ phase transition shows a discontinuity at the composition where the martensitic transformation temperatures fall below room temperature (between 34 and 38 at. % Ta) rendering it first order and confirming its martensitic nature. A short study of the α″ martensite employing the Landau theory is included for a mathematical quantification of the spontaneous lattice strain at room temperature (ϵ̂max = 22.4(6) % for pure Ti). Martensitic properties of Ti–Ta are beneficial for the development of high-temperature actuators with actuation response at transformation temperatures higher than 100 °C.