Abdorasoul Ghasemi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Abdorasoul Ghasemi has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Hermann de Meer
Chair of Computer Networking and Computer Communications, University of Passau, Passau, Germany
4 shared publicationsZahra Alavikia
4 shared publicationsMárton Pósfai
Department of Network and Data Science, Central European University, Vienna, Austria
3 shared publications- Roya Aliakbarisani
Universitat de Barcelona
3 shared publications Alex Fornito
The Turner Institute for Brain and Mental Health, School of Psychological Sciences, and Monash Biomedical Imaging, Monash University, Clayton, Australia
2 shared publications- Amit Dilip Patil
Chair of Computer Networking and Computer Communications, University of Passau, Passau, Germany
2 shared publications
Latest Publications
- Open Access
- 20 September 2026
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 278
Mitigating cascading failures through intentional line removal: A conditional reinforcement learning approach
- 20 September 2026
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 278
Open AccessMitigating cascading failures through intentional line removal: A conditional reinforcement learning approach
- Open Access
- 22 June 2026
- Published by Association for Computing Machinery (ACM)
- p. 154-167
Cascading Failure Sequence Prediction Using Generative Pre-trained Transformers in Power Networks
- 22 June 2026
- Published by Association for Computing Machinery (ACM)
- p. 154-167
Open AccessCascading Failure Sequence Prediction Using Generative Pre-trained Transformers in Power Networks
- 26 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Cloud Computing
- Vol. PP (3) , 1-14
A Resilient Edge Data Integrity Verification Approach Via Robust Merkle Trees and Steganographic Transmission
Edge Data Integrity Verification (EDIV) plays a crucial role in maintaining the authenticity of cached data replicas in decentralized and resource-constrained edge computing environments. However, existing EDIV methods prioritize generating cryptographic proofs while overlooking the need to ensure robustness against localized data tampering and neglecting the inherent security risks involved in transmitting these proofs over untrusted backhaul communication networks. These gaps leave the EDIV process vulnerable to both the manipulation of integrity proofs and their interception during transmission, ultimately undermining the reliability of EDIV. To address these gaps, we propose RAMTStego-EDIV, a novel framework that ensures both the robustness of integrity proofs and their secure transmission. In particular, RAMTStego-EDIV first introduces the Robust Aggregated Merkle Tree (RAMT)—a ternary hash tree that combines real and auxiliary nodes to produce tamper-evident cryptographic proofs, ensuring that even partial manipulation of the data can be reliably detected. Then, it develops a dual-parity transmission control protocol (TCP) steganography technique to protect the transmission of the RAMT-driven cryptographic proofs that covertly embed the proof bits into two TCP header fields: the parity of the payload length and the least significant bit of the TCP window size. This embedding allows proofs to travel invisibly within normal traffic, avoiding detection and interference by adversaries monitoring the network. Both theoretical analysis and experimental results demonstrate that RAMTStego-EDIV prevents proof tampering and interception, confirming its resilience and suitability for deployment in adversarial mobile edge computing environments.
- 26 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Cloud Computing
- Vol. PP (3) , 1-14
A Resilient Edge Data Integrity Verification Approach Via Robust Merkle Trees and Steganographic Transmission
Edge Data Integrity Verification (EDIV) plays a crucial role in maintaining the authenticity of cached data replicas in decentralized and resource-constrained edge computing environments. However, existing EDIV methods prioritize generating cryptographic proofs while overlooking the need to ensure robustness against localized data tampering and neglecting the inherent security risks involved in transmitting these proofs over untrusted backhaul communication networks. These gaps leave the EDIV process vulnerable to both the manipulation of integrity proofs and their interception during transmission, ultimately undermining the reliability of EDIV. To address these gaps, we propose RAMTStego-EDIV, a novel framework that ensures both the robustness of integrity proofs and their secure transmission. In particular, RAMTStego-EDIV first introduces the Robust Aggregated Merkle Tree (RAMT)—a ternary hash tree that combines real and auxiliary nodes to produce tamper-evident cryptographic proofs, ensuring that even partial manipulation of the data can be reliably detected. Then, it develops a dual-parity transmission control protocol (TCP) steganography technique to protect the transmission of the RAMT-driven cryptographic proofs that covertly embed the proof bits into two TCP header fields: the parity of the payload length and the least significant bit of the TCP window size. This embedding allows proofs to travel invisibly within normal traffic, avoiding detection and interference by adversaries monitoring the network. Both theoretical analysis and experimental results demonstrate that RAMTStego-EDIV prevents proof tampering and interception, confirming its resilience and suitability for deployment in adversarial mobile edge computing environments.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Network and Service Management
- Vol. 22 (2) , 1409-1419
Optimal Redundant Sensor Placement for Protection Blinding in Active Distribution Grids
Integrating renewable energy sources into the power distribution grid challenges protection system operation, leading to protection blinding when circuit breakers fail to trip due to fault current contribution from these sources. Communication-based adaptive protection can address this issue, but communication system components like sensors can fail. This research proposes a genetic algorithm-based approach to optimally place redundant sensors, minimizing protection blinding under communication uncertainty within a redundancy budget. The fault tolerance, measured by a new metric called redundancy degree, reflects the number of redundant components deployed. Results demonstrate the algorithm’s effectiveness in optimizing redundant sensor locations, reducing system costs, and improving fault tolerance. For the system and scenarios investigated, an average of 60% redundant sensors are relocated, reducing the average protection trip time by 36.65% compared to a baseline approach that does not consider communication uncertainty. This encourages incorporating communication component failure considerations in power system planning.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Network and Service Management
- Vol. 22 (2) , 1409-1419
Optimal Redundant Sensor Placement for Protection Blinding in Active Distribution Grids
Integrating renewable energy sources into the power distribution grid challenges protection system operation, leading to protection blinding when circuit breakers fail to trip due to fault current contribution from these sources. Communication-based adaptive protection can address this issue, but communication system components like sensors can fail. This research proposes a genetic algorithm-based approach to optimally place redundant sensors, minimizing protection blinding under communication uncertainty within a redundancy budget. The fault tolerance, measured by a new metric called redundancy degree, reflects the number of redundant components deployed. Results demonstrate the algorithm’s effectiveness in optimizing redundant sensor locations, reducing system costs, and improving fault tolerance. For the system and scenarios investigated, an average of 60% redundant sensors are relocated, reducing the average protection trip time by 36.65% compared to a baseline approach that does not consider communication uncertainty. This encourages incorporating communication component failure considerations in power system planning.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Network and Service Management
- Vol. 21 (5) , 5250-5259
Towards Forming Optimal Communication Network for Effective Power System Restoration
Restoration of modern interdependent ICT and power networks relies on preplanned and reactive strategies to consider simultaneous communication and power system recovery. This paper addresses the problem of finding and energizing a proper communication network connecting the distributed power grid assets in the restoration process, assuming a probability of infeasibility of recovering each communication node. The proper network has the minimum size, meets the communication requirements of power system recovery, and guarantees robustness against ICT nodes not being recoverable during restoration. The problem is formulated as a multi-objective optimization problem and solved using the genetic algorithm to find the optimal subgraph that ensures enough node-disjoint paths between the communicating power grid assets. Simulation results for the restoration strategy of the communication network associated with a power network are provided and discussed. The results show that networks’ ability to mitigate the adverse consequences of node failures can be significantly improved by incorporating just a few additional nodes and links while keeping the ICT network compact and feasible for restoration.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Network and Service Management
- Vol. 21 (5) , 5250-5259
Towards Forming Optimal Communication Network for Effective Power System Restoration
Restoration of modern interdependent ICT and power networks relies on preplanned and reactive strategies to consider simultaneous communication and power system recovery. This paper addresses the problem of finding and energizing a proper communication network connecting the distributed power grid assets in the restoration process, assuming a probability of infeasibility of recovering each communication node. The proper network has the minimum size, meets the communication requirements of power system recovery, and guarantees robustness against ICT nodes not being recoverable during restoration. The problem is formulated as a multi-objective optimization problem and solved using the genetic algorithm to find the optimal subgraph that ensures enough node-disjoint paths between the communicating power grid assets. Simulation results for the restoration strategy of the communication network associated with a power network are provided and discussed. The results show that networks’ ability to mitigate the adverse consequences of node failures can be significantly improved by incorporating just a few additional nodes and links while keeping the ICT network compact and feasible for restoration.
- Open Access
- 30 June 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (11) , 1783-1797
Analysis of protection blinding in active distribution grids
Protection blinding is a challenging issue in renewables‐penetrated distribution grids and refers to a situation where a circuit breaker may not trip due to fault current contribution from distributed generation. This research addresses how the distributed generation location and capacity impact the operation of the circuit breaker in terms of the response time of the circuit breakers. The relative electrical distances of the faults and distributed generation to the circuit breakers are considered. The impact of distributed generation capacity considering the fault location is characterized using a new index called the heterogeneity index. The electrical distance between distributed generations and circuit breakers and the electrical distance between fault and circuit breaker is considered by a second new index called the electrical distance ratio. Data analysis on simulation results shows that these indices capture the phenomena of protection blinding caused by distributed generation. Results show that a higher distributed generation penetration and faults that are electrically further away from a circuit breaker show severe cases of protection blinding captured by the indices. Furthermore, it is demonstrated how these indices can identify the worst impacted locations in the distribution grid. A key result is that protection blinding does not necessarily occur solely due to the presence of distributed generation between a circuit breaker and a fault, but is dependent on factors such as distributed generation location in the distribution grid, fault level, fault level distribution across the generation units and fault location.
- 30 June 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (11) , 1783-1797
Open AccessAnalysis of protection blinding in active distribution grids
Protection blinding is a challenging issue in renewables‐penetrated distribution grids and refers to a situation where a circuit breaker may not trip due to fault current contribution from distributed generation. This research addresses how the distributed generation location and capacity impact the operation of the circuit breaker in terms of the response time of the circuit breakers. The relative electrical distances of the faults and distributed generation to the circuit breakers are considered. The impact of distributed generation capacity considering the fault location is characterized using a new index called the heterogeneity index. The electrical distance between distributed generations and circuit breakers and the electrical distance between fault and circuit breaker is considered by a second new index called the electrical distance ratio. Data analysis on simulation results shows that these indices capture the phenomena of protection blinding caused by distributed generation. Results show that a higher distributed generation penetration and faults that are electrically further away from a circuit breaker show severe cases of protection blinding captured by the indices. Furthermore, it is demonstrated how these indices can identify the worst impacted locations in the distribution grid. A key result is that protection blinding does not necessarily occur solely due to the presence of distributed generation between a circuit breaker and a fault, but is dependent on factors such as distributed generation location in the distribution grid, fault level, fault level distribution across the generation units and fault location.
- Open Access
- 22 March 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
The impact of input node placement in the controllability of structural brain networks
Network controllability refers to the ability to steer the state of a network towards a target state by driving certain nodes, known as input nodes. This concept can be applied to brain networks for studying brain function and its relation to the structure, which has numerous practical applications. Brain network controllability involves using external signals such as electrical stimulation to drive specific brain regions and navigate the neurophysiological activity level of the brain around the state space. Although controllability is mainly theoretical, the energy required for control is critical in real-world implementations. With a focus on the structural brain networks, this study explores the impact of white matter fiber architecture on the control energy in brain networks using the theory of how input node placement affects the LCC (the longest distance between inputs and other network nodes). Initially, we use a single input node as it is theoretically possible to control brain networks with just one input. We show that highly connected brain regions that lead to lower LCCs are more energy-efficient as a single input node. However, there may still be a need for a significant amount of control energy with one input, and achieving controllability with less energy could be of interest. We identify the minimum number of input nodes required to control brain networks with smaller LCCs, demonstrating that reducing the LCC can significantly decrease the control energy in brain networks. Our results show that relying solely on highly connected nodes is not effective in controlling brain networks with lower energy by using multiple inputs because of densely interconnected brain network hubs. Instead, a combination of low and high-degree nodes is necessary.
- 22 March 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
Open AccessThe impact of input node placement in the controllability of structural brain networks
Network controllability refers to the ability to steer the state of a network towards a target state by driving certain nodes, known as input nodes. This concept can be applied to brain networks for studying brain function and its relation to the structure, which has numerous practical applications. Brain network controllability involves using external signals such as electrical stimulation to drive specific brain regions and navigate the neurophysiological activity level of the brain around the state space. Although controllability is mainly theoretical, the energy required for control is critical in real-world implementations. With a focus on the structural brain networks, this study explores the impact of white matter fiber architecture on the control energy in brain networks using the theory of how input node placement affects the LCC (the longest distance between inputs and other network nodes). Initially, we use a single input node as it is theoretically possible to control brain networks with just one input. We show that highly connected brain regions that lead to lower LCCs are more energy-efficient as a single input node. However, there may still be a need for a significant amount of control energy with one input, and achieving controllability with less energy could be of interest. We identify the minimum number of input nodes required to control brain networks with smaller LCCs, demonstrating that reducing the LCC can significantly decrease the control energy in brain networks. Our results show that relying solely on highly connected nodes is not effective in controlling brain networks with lower energy by using multiple inputs because of densely interconnected brain network hubs. Instead, a combination of low and high-degree nodes is necessary.
- 29 February 2024
- Published by Springer Nature
- p. 219-230
An Interaction-Dependent Model for Probabilistic Cascading Failure
- 29 February 2024
- Published by Springer Nature
- p. 219-230
An Interaction-Dependent Model for Probabilistic Cascading Failure
- Open Access
- 19 October 2023
- Published by Springer Nature in Energy Informatics
- Vol. 6 (S1) , 1-14
Interaction graph learning of line cascading failure in power networks and its statistical properties
- 19 October 2023
- Published by Springer Nature in Energy Informatics
- Vol. 6 (S1) , 1-14
Open AccessInteraction graph learning of line cascading failure in power networks and its statistical properties
- Open Access
The impact of input node placement in the controllability of brain networks
Network control theory can be used to model how one should steer the brain between different states by driving a specific region with an input. The needed energy to control a network is often used to quantify its controllability, and controlling brain networks requires diverse energy depending on the selected input region. We use the theory of how input node placement affects the longest control chain (LCC) in the controllability of brain networks to study the role of the architecture of white matter fibers in the required control energy. We show that the energy needed to control human brain networks is related to the LCC, i.e., the longest distance between the input region and other regions in the network. We indicate that regions that control brain networks with lower energy have small LCCs. These regions align with areas that can steer the brain around the state space smoothly. By contrast, regions that need higher energy to move the brain toward different target states have larger LCCs. We also investigate the role of the number of paths between regions in the control energy. Our results show that the more paths between regions, the lower cost needed to control brain networks. We evaluate the number of paths by counting specific motifs in brain networks since determining all paths in graphs is a difficult problem.
Open AccessThe impact of input node placement in the controllability of brain networks
Network control theory can be used to model how one should steer the brain between different states by driving a specific region with an input. The needed energy to control a network is often used to quantify its controllability, and controlling brain networks requires diverse energy depending on the selected input region. We use the theory of how input node placement affects the longest control chain (LCC) in the controllability of brain networks to study the role of the architecture of white matter fibers in the required control energy. We show that the energy needed to control human brain networks is related to the LCC, i.e., the longest distance between the input region and other regions in the network. We indicate that regions that control brain networks with lower energy have small LCCs. These regions align with areas that can steer the brain around the state space smoothly. By contrast, regions that need higher energy to move the brain toward different target states have larger LCCs. We also investigate the role of the number of paths between regions in the control energy. Our results show that the more paths between regions, the lower cost needed to control brain networks. We evaluate the number of paths by counting specific motifs in brain networks since determining all paths in graphs is a difficult problem.