Amit Dilip Patil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amit Dilip Patil has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Abdorasoul Ghasemi
Research Centre for Computational Science and Mathematical Modelling, Coventry University, Coventry, United Kingdom
2 shared publications Hermann de Meer
Chair of Computer Networking and Computer Communications, University of Passau, Passau, Germany
2 shared publications- Anand Narayan
Energy Division, OFFIS - Institute for Information Technology, Oldenburg, Germany and Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany
1 shared publication - Christian Rehtanz
Institute of Energy Systems, Energy Efficiency and Energy Economics, TU Dortmund University, Dortmund, Germany
1 shared publication H. de Meer
1 shared publication- Hermann de Meer
University of Passau, Passau, Germany
1 shared publication
Latest Publications
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Network and Service Management
- Vol. 22 (2) , 1409-1419
Optimal Redundant Sensor Placement for Protection Blinding in Active Distribution Grids
Integrating renewable energy sources into the power distribution grid challenges protection system operation, leading to protection blinding when circuit breakers fail to trip due to fault current contribution from these sources. Communication-based adaptive protection can address this issue, but communication system components like sensors can fail. This research proposes a genetic algorithm-based approach to optimally place redundant sensors, minimizing protection blinding under communication uncertainty within a redundancy budget. The fault tolerance, measured by a new metric called redundancy degree, reflects the number of redundant components deployed. Results demonstrate the algorithm’s effectiveness in optimizing redundant sensor locations, reducing system costs, and improving fault tolerance. For the system and scenarios investigated, an average of 60% redundant sensors are relocated, reducing the average protection trip time by 36.65% compared to a baseline approach that does not consider communication uncertainty. This encourages incorporating communication component failure considerations in power system planning.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Network and Service Management
- Vol. 22 (2) , 1409-1419
Optimal Redundant Sensor Placement for Protection Blinding in Active Distribution Grids
Integrating renewable energy sources into the power distribution grid challenges protection system operation, leading to protection blinding when circuit breakers fail to trip due to fault current contribution from these sources. Communication-based adaptive protection can address this issue, but communication system components like sensors can fail. This research proposes a genetic algorithm-based approach to optimally place redundant sensors, minimizing protection blinding under communication uncertainty within a redundancy budget. The fault tolerance, measured by a new metric called redundancy degree, reflects the number of redundant components deployed. Results demonstrate the algorithm’s effectiveness in optimizing redundant sensor locations, reducing system costs, and improving fault tolerance. For the system and scenarios investigated, an average of 60% redundant sensors are relocated, reducing the average protection trip time by 36.65% compared to a baseline approach that does not consider communication uncertainty. This encourages incorporating communication component failure considerations in power system planning.
- Open Access
- 30 June 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (11) , 1783-1797
Analysis of protection blinding in active distribution grids
Protection blinding is a challenging issue in renewables‐penetrated distribution grids and refers to a situation where a circuit breaker may not trip due to fault current contribution from distributed generation. This research addresses how the distributed generation location and capacity impact the operation of the circuit breaker in terms of the response time of the circuit breakers. The relative electrical distances of the faults and distributed generation to the circuit breakers are considered. The impact of distributed generation capacity considering the fault location is characterized using a new index called the heterogeneity index. The electrical distance between distributed generations and circuit breakers and the electrical distance between fault and circuit breaker is considered by a second new index called the electrical distance ratio. Data analysis on simulation results shows that these indices capture the phenomena of protection blinding caused by distributed generation. Results show that a higher distributed generation penetration and faults that are electrically further away from a circuit breaker show severe cases of protection blinding captured by the indices. Furthermore, it is demonstrated how these indices can identify the worst impacted locations in the distribution grid. A key result is that protection blinding does not necessarily occur solely due to the presence of distributed generation between a circuit breaker and a fault, but is dependent on factors such as distributed generation location in the distribution grid, fault level, fault level distribution across the generation units and fault location.
- 30 June 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (11) , 1783-1797
Open AccessAnalysis of protection blinding in active distribution grids
Protection blinding is a challenging issue in renewables‐penetrated distribution grids and refers to a situation where a circuit breaker may not trip due to fault current contribution from distributed generation. This research addresses how the distributed generation location and capacity impact the operation of the circuit breaker in terms of the response time of the circuit breakers. The relative electrical distances of the faults and distributed generation to the circuit breakers are considered. The impact of distributed generation capacity considering the fault location is characterized using a new index called the heterogeneity index. The electrical distance between distributed generations and circuit breakers and the electrical distance between fault and circuit breaker is considered by a second new index called the electrical distance ratio. Data analysis on simulation results shows that these indices capture the phenomena of protection blinding caused by distributed generation. Results show that a higher distributed generation penetration and faults that are electrically further away from a circuit breaker show severe cases of protection blinding captured by the indices. Furthermore, it is demonstrated how these indices can identify the worst impacted locations in the distribution grid. A key result is that protection blinding does not necessarily occur solely due to the presence of distributed generation between a circuit breaker and a fault, but is dependent on factors such as distributed generation location in the distribution grid, fault level, fault level distribution across the generation units and fault location.
- 18 July 2022
- Published by Elsevier in Electric Power Systems Research
- Vol. 212
A Hybrid Model for Analysing Disturbance Propagation in Cyber–Physical Energy Systems
- 18 July 2022
- Published by Elsevier in Electric Power Systems Research
- Vol. 212
A Hybrid Model for Analysing Disturbance Propagation in Cyber–Physical Energy Systems
- Open Access
- 28 October 2020
- Published by Springer Nature in Energy Informatics
- Vol. 3 (S1) , 1-20
Modeling interconnected ICT and power systems for resilience analysis
- 28 October 2020
- Published by Springer Nature in Energy Informatics
- Vol. 3 (S1) , 1-20
Open AccessModeling interconnected ICT and power systems for resilience analysis