James Parker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
James Parker has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- David Glew
Leeds Beckett University
3 shared publications Christopher Gorse
2 shared publicationsFelix Thomas
School of the Built Environment, Engineering and Computing, Leeds Sustainability Institute, Leeds Beckett University, Leeds, UK
2 shared publications- Felix Thomas
Centre for the Built Environment, Leeds Sustainability Institute, Leeds Beckett University, UK
2 shared publications Martin Fletcher
School of the Built Environment, Engineering and Computing, Leeds Sustainability Institute, Leeds Beckett University, Leeds, UK
2 shared publications- Martin Fletcher
Leeds Beckett University
2 shared publications
Latest Publications
- Open Access
- 30 March 2026
- Published by Wiley in People and Nature
- Vol. 8 (11) , 3775-3793
Comfort in the canopy: How urban treescapes affect human thermal comfort in a temperate climate
People living in urban centres are exposed to higher levels of heat stress than those living outside of these areas; this is intensified by the urban heat island effect. Heat stress is a concern for the more vulnerable members of society and can exacerbate many medical conditions; excessive heat increases morbidity and mortality rates. Green infrastructure can help to mitigate against excessive urban heat and provide more thermally comfortable environments. This paper presents data from a high spatial and temporal resolution microclimate sensor network in the city of Leeds, United Kingdom. Sensors are installed in grey spaces and green spaces, including small city centre parks, large suburban parks and treescapes. Analysis focuses on two summer periods (June–August 2023 and 2024). These data demonstrate that treescapes offer the greatest relief from excessive urban heat when compared with other greenspaces. Urban treescapes were a mean of 1.4°C cooler than surrounding grey spaces, compared with a difference of 0.7°C between parks and grey spaces. During peak air temperature periods, parks were up to 2.8°C cooler, and treescapes were up to 5°C cooler than grey urban spaces. Universal Thermal Climate Index calculations demonstrate that the urban treescapes consistently provide lower exposure to heat stress; when sub‐canopy solar radiation levels are considered, treescapes expose citizens to 96% fewer hours of strong heat stress and 64% fewer hours of moderate heat stress than urban grey spaces. Results presented in this paper support the retention and expansion of urban greenspaces and urban treescapes; specifically, they also have important implications for a range of associated issues including citizen health and well‐being, inclusive, just access, urban planning and policy development. Read the free Plain Language Summary for this article on the Journal blog.
- 30 March 2026
- Published by Wiley in People and Nature
- Vol. 8 (11) , 3775-3793
Open AccessComfort in the canopy: How urban treescapes affect human thermal comfort in a temperate climate
People living in urban centres are exposed to higher levels of heat stress than those living outside of these areas; this is intensified by the urban heat island effect. Heat stress is a concern for the more vulnerable members of society and can exacerbate many medical conditions; excessive heat increases morbidity and mortality rates. Green infrastructure can help to mitigate against excessive urban heat and provide more thermally comfortable environments. This paper presents data from a high spatial and temporal resolution microclimate sensor network in the city of Leeds, United Kingdom. Sensors are installed in grey spaces and green spaces, including small city centre parks, large suburban parks and treescapes. Analysis focuses on two summer periods (June–August 2023 and 2024). These data demonstrate that treescapes offer the greatest relief from excessive urban heat when compared with other greenspaces. Urban treescapes were a mean of 1.4°C cooler than surrounding grey spaces, compared with a difference of 0.7°C between parks and grey spaces. During peak air temperature periods, parks were up to 2.8°C cooler, and treescapes were up to 5°C cooler than grey urban spaces. Universal Thermal Climate Index calculations demonstrate that the urban treescapes consistently provide lower exposure to heat stress; when sub‐canopy solar radiation levels are considered, treescapes expose citizens to 96% fewer hours of strong heat stress and 64% fewer hours of moderate heat stress than urban grey spaces. Results presented in this paper support the retention and expansion of urban greenspaces and urban treescapes; specifically, they also have important implications for a range of associated issues including citizen health and well‐being, inclusive, just access, urban planning and policy development. Read the free Plain Language Summary for this article on the Journal blog.
- Open Access
- 28 May 2025
- Published by Ubiquity Press, Ltd. in Buildings and Cities
- Vol. 6 (1) , 239-254
Quantifying inter-dwelling air exchanges during fan pressurisation tests
Fan pressurisation tests (FPTs) are commonly used to measure air leakage in homes, to provide evidence for compliance with energy and ventilation standards in building regulations and inform energy models. The results are presented of 37 pressurisation and co-pressurisation tests on attached homes in the UK which measured inter-dwelling air exchanges during the FPTs. On average, 21% of the air leakage measured by the FPTs was found to be inter-dwelling rather than inside-to-outside air exchange, i.e. homes are more airtight than FPTs indicate, which is important when assessing energy efficiency and ventilation performance thresholds. Not accounting for inter-dwelling air exchanges poses a risk of under-ventilation and misclassification of homes deemed suitable for natural ventilation. Using the FPT result to replace default values for airtightness in energy models used to create Energy Performance Certificates (EPCs) for 11 of the case study homes improved their energy efficiency rating (EER), indicating default airtightness values used in EPCs used were overestimating the air leakage. Using the co-pressurisation value resulted in an additional EER point. These modest improvements represented a 5%, 8% and 3% reduction in predicted annual carbon emission, space heating demand and fuel bills, respectively. Practice relevance The airtightness of homes is fundamental to their energy efficiency and ventilation requirements. The FPT is commonly used to measure airtightness in homes; however, this research has shown that the FPT can overpredict air leakage in attached homes due to the elevated pressures during the test cause inter-dwelling air exchanges not experienced under non-test conditions. This may affect the accuracy of FPTs in attached homes and the appropriateness of using the FPT result to inform building regulation compliance, ventilation decisions and energy models. The research has implications for FPT standards, testing practitioners and professional bodies, energy modellers, ventilation designers, policymakers, and regulations. The development of further knowledge, industry guidance and protocols is required for inter-dwelling air exchange taking place during the FPT, particularly for different house type, form and construction.
- 28 May 2025
- Published by Ubiquity Press, Ltd. in Buildings and Cities
- Vol. 6 (1) , 239-254
Open AccessQuantifying inter-dwelling air exchanges during fan pressurisation tests
Fan pressurisation tests (FPTs) are commonly used to measure air leakage in homes, to provide evidence for compliance with energy and ventilation standards in building regulations and inform energy models. The results are presented of 37 pressurisation and co-pressurisation tests on attached homes in the UK which measured inter-dwelling air exchanges during the FPTs. On average, 21% of the air leakage measured by the FPTs was found to be inter-dwelling rather than inside-to-outside air exchange, i.e. homes are more airtight than FPTs indicate, which is important when assessing energy efficiency and ventilation performance thresholds. Not accounting for inter-dwelling air exchanges poses a risk of under-ventilation and misclassification of homes deemed suitable for natural ventilation. Using the FPT result to replace default values for airtightness in energy models used to create Energy Performance Certificates (EPCs) for 11 of the case study homes improved their energy efficiency rating (EER), indicating default airtightness values used in EPCs used were overestimating the air leakage. Using the co-pressurisation value resulted in an additional EER point. These modest improvements represented a 5%, 8% and 3% reduction in predicted annual carbon emission, space heating demand and fuel bills, respectively. Practice relevance The airtightness of homes is fundamental to their energy efficiency and ventilation requirements. The FPT is commonly used to measure airtightness in homes; however, this research has shown that the FPT can overpredict air leakage in attached homes due to the elevated pressures during the test cause inter-dwelling air exchanges not experienced under non-test conditions. This may affect the accuracy of FPTs in attached homes and the appropriateness of using the FPT result to inform building regulation compliance, ventilation decisions and energy models. The research has implications for FPT standards, testing practitioners and professional bodies, energy modellers, ventilation designers, policymakers, and regulations. The development of further knowledge, industry guidance and protocols is required for inter-dwelling air exchange taking place during the FPT, particularly for different house type, form and construction.
- Open Access
- 7 November 2024
- Published by Taylor & Francis in Sustainable Environment
- Vol. 10 (1)
Characteristics of air temperature and thermal comfort in the grey and green spaces of an urban heat island
- 7 November 2024
- Published by Taylor & Francis in Sustainable Environment
- Vol. 10 (1)
Open AccessCharacteristics of air temperature and thermal comfort in the grey and green spaces of an urban heat island
- Open Access
A Heat Loss Sensitivity Index to Inform Housing Retrofit Policy in the UK
A substantial number of dwellings in the UK have poor building fabric, leading to higher carbon emissions, fuel expenses, and the risk of cold homes. To tackle these challenges, domestic energy efficiency policies are being implemented. One effective approach is the use of energy models, which enable sensitivity analysis to provide valuable insights for policymakers. This study employed dynamic thermal simulation models for 32 housing archetypes representative of solid-walled homes in the UK to calculate the heat loss and the sensitivity coefficient per building fabric feature, after which a metric Heat Loss Sensitivity (HLS) index was established to guide the selection of retrofit features for each archetype. The building fabric features’ inputs were then adjusted to establish both lower and upper bounds, simulating low and high performance levels, to predict the how space heating energy demand varies. The analysis was extended by replicating the process with various scenarios considering climates, window-to-wall ratios, and overshadowing. The findings highlight the external wall as the primary consideration in retrofitting due to its high HLS index, even at high window-to-wall ratios. It was also established that dwelling type is important in retrofit decision-making, with floor and loft retrofits having a high HLS index in bungalows. Furthermore, the analysis underlines the necessity for Standard Assessment Procedure assessors to evaluate loft U-value and air permeability rates prior to implementing retrofit measures, given the significance of these factors in the lower and upper bounds analysis. Researchers globally can replicate the HLS index approach, facilitating the implementation of housing retrofit policies worldwide.
Open AccessA Heat Loss Sensitivity Index to Inform Housing Retrofit Policy in the UK
A substantial number of dwellings in the UK have poor building fabric, leading to higher carbon emissions, fuel expenses, and the risk of cold homes. To tackle these challenges, domestic energy efficiency policies are being implemented. One effective approach is the use of energy models, which enable sensitivity analysis to provide valuable insights for policymakers. This study employed dynamic thermal simulation models for 32 housing archetypes representative of solid-walled homes in the UK to calculate the heat loss and the sensitivity coefficient per building fabric feature, after which a metric Heat Loss Sensitivity (HLS) index was established to guide the selection of retrofit features for each archetype. The building fabric features’ inputs were then adjusted to establish both lower and upper bounds, simulating low and high performance levels, to predict the how space heating energy demand varies. The analysis was extended by replicating the process with various scenarios considering climates, window-to-wall ratios, and overshadowing. The findings highlight the external wall as the primary consideration in retrofitting due to its high HLS index, even at high window-to-wall ratios. It was also established that dwelling type is important in retrofit decision-making, with floor and loft retrofits having a high HLS index in bungalows. Furthermore, the analysis underlines the necessity for Standard Assessment Procedure assessors to evaluate loft U-value and air permeability rates prior to implementing retrofit measures, given the significance of these factors in the lower and upper bounds analysis. Researchers globally can replicate the HLS index approach, facilitating the implementation of housing retrofit policies worldwide.
- 1 February 2019
- Published by Elsevier in Energy and Buildings
- Vol. 185, 49-65
Measuring and modelling retrofit fabric performance in solid wall conjoined dwellings
- 1 February 2019
- Published by Elsevier in Energy and Buildings
- Vol. 185, 49-65
Measuring and modelling retrofit fabric performance in solid wall conjoined dwellings
- 1 April 2017
- Published by Springer Nature
- p. 163-183
Predicting Future Overheating in a Passivhaus Dwelling Using Calibrated Dynamic Thermal Simulation Models
- 1 April 2017
- Published by Springer Nature
- p. 163-183
Predicting Future Overheating in a Passivhaus Dwelling Using Calibrated Dynamic Thermal Simulation Models
- Open Access
- 28 October 2016
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 38 (3) , 253-268
Accounting for refrigeration heat exchange in energy performance simulations of large food retail buildings
Heat exchange between chilled food storage and conditioned spaces in large food retail stores is not currently required as part of design stage regulatory compliance energy performance models. Existing work has identified that this exchange has a significant impact on store energy demand and subsequently leads to unrealistic assessment of building performance. Research presented in this article uses whole building dynamic thermal simulation models that are calibrated against real store performance data, quantifying the impact of the refrigeration driven heat exchange. Proxy refrigerated units are used to simulate the impact of these units for the sales floor areas. A methodology is presented that allows these models to be simplified with the aim of calculating a realistic process heat exchange for refrigeration and including this in thermal simulation models; a protocol for the measurement of chilled sales areas and their inclusion in the building models is also proposed. It is intended that this modelling approach and the calculated process heat exchange inputs can be used to improve the dynamic thermal simulation of large food retail stores, reduce gaps between predicted and actual performance and provide more representative inputs for design stage and regulatory compliance energy calculations. Practical application: The modelling methodology and research findings presented in the article are of practical use for building energy modelling engineers using dynamic simulation models to design and/or evaluate the energy performance of large food retail stores. The methodology can be used in the design of new facilities or the evaluation of large scale retrofit projects. It is also of practical interest to energy and facility managers within large food retail organisations as it will aid their understanding of applied energy performance models.
- 28 October 2016
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 38 (3) , 253-268
Open AccessAccounting for refrigeration heat exchange in energy performance simulations of large food retail buildings
Heat exchange between chilled food storage and conditioned spaces in large food retail stores is not currently required as part of design stage regulatory compliance energy performance models. Existing work has identified that this exchange has a significant impact on store energy demand and subsequently leads to unrealistic assessment of building performance. Research presented in this article uses whole building dynamic thermal simulation models that are calibrated against real store performance data, quantifying the impact of the refrigeration driven heat exchange. Proxy refrigerated units are used to simulate the impact of these units for the sales floor areas. A methodology is presented that allows these models to be simplified with the aim of calculating a realistic process heat exchange for refrigeration and including this in thermal simulation models; a protocol for the measurement of chilled sales areas and their inclusion in the building models is also proposed. It is intended that this modelling approach and the calculated process heat exchange inputs can be used to improve the dynamic thermal simulation of large food retail stores, reduce gaps between predicted and actual performance and provide more representative inputs for design stage and regulatory compliance energy calculations. Practical application: The modelling methodology and research findings presented in the article are of practical use for building energy modelling engineers using dynamic simulation models to design and/or evaluate the energy performance of large food retail stores. The methodology can be used in the design of new facilities or the evaluation of large scale retrofit projects. It is also of practical interest to energy and facility managers within large food retail organisations as it will aid their understanding of applied energy performance models.