Felix Thomas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Felix Thomas has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- David Glew
Leeds Beckett University
2 shared publications - Dominic Miles-Shenton2 shared publications
- James Parker
Leeds Beckett University Leeds UK
2 shared publications Christopher Gorse
Centre for the Built Environment, Leeds Sustainability Institute, Leeds Beckett University, UK
1 shared publication- Daniel Dobrowolski1 shared publication
- David Johnston
School of the Built Environment and Engineering, Leeds Beckett University, Leeds, UK
1 shared publication
Latest Publications
- Open Access
- 19 August 2026
- Published by Elsevier in Energy and Buildings
- Vol. 370
A novel approach to rapidly identifying, quantifying and ranking air leakage
- 19 August 2026
- Published by Elsevier in Energy and Buildings
- Vol. 370
Open AccessA novel approach to rapidly identifying, quantifying and ranking air leakage
- Open Access
- 28 May 2025
- Published by Ubiquity Press, Ltd. in Buildings and Cities
- Vol. 6 (1) , 239-254
Quantifying inter-dwelling air exchanges during fan pressurisation tests
Fan pressurisation tests (FPTs) are commonly used to measure air leakage in homes, to provide evidence for compliance with energy and ventilation standards in building regulations and inform energy models. The results are presented of 37 pressurisation and co-pressurisation tests on attached homes in the UK which measured inter-dwelling air exchanges during the FPTs. On average, 21% of the air leakage measured by the FPTs was found to be inter-dwelling rather than inside-to-outside air exchange, i.e. homes are more airtight than FPTs indicate, which is important when assessing energy efficiency and ventilation performance thresholds. Not accounting for inter-dwelling air exchanges poses a risk of under-ventilation and misclassification of homes deemed suitable for natural ventilation. Using the FPT result to replace default values for airtightness in energy models used to create Energy Performance Certificates (EPCs) for 11 of the case study homes improved their energy efficiency rating (EER), indicating default airtightness values used in EPCs used were overestimating the air leakage. Using the co-pressurisation value resulted in an additional EER point. These modest improvements represented a 5%, 8% and 3% reduction in predicted annual carbon emission, space heating demand and fuel bills, respectively. Practice relevance The airtightness of homes is fundamental to their energy efficiency and ventilation requirements. The FPT is commonly used to measure airtightness in homes; however, this research has shown that the FPT can overpredict air leakage in attached homes due to the elevated pressures during the test cause inter-dwelling air exchanges not experienced under non-test conditions. This may affect the accuracy of FPTs in attached homes and the appropriateness of using the FPT result to inform building regulation compliance, ventilation decisions and energy models. The research has implications for FPT standards, testing practitioners and professional bodies, energy modellers, ventilation designers, policymakers, and regulations. The development of further knowledge, industry guidance and protocols is required for inter-dwelling air exchange taking place during the FPT, particularly for different house type, form and construction.
- 28 May 2025
- Published by Ubiquity Press, Ltd. in Buildings and Cities
- Vol. 6 (1) , 239-254
Open AccessQuantifying inter-dwelling air exchanges during fan pressurisation tests
Fan pressurisation tests (FPTs) are commonly used to measure air leakage in homes, to provide evidence for compliance with energy and ventilation standards in building regulations and inform energy models. The results are presented of 37 pressurisation and co-pressurisation tests on attached homes in the UK which measured inter-dwelling air exchanges during the FPTs. On average, 21% of the air leakage measured by the FPTs was found to be inter-dwelling rather than inside-to-outside air exchange, i.e. homes are more airtight than FPTs indicate, which is important when assessing energy efficiency and ventilation performance thresholds. Not accounting for inter-dwelling air exchanges poses a risk of under-ventilation and misclassification of homes deemed suitable for natural ventilation. Using the FPT result to replace default values for airtightness in energy models used to create Energy Performance Certificates (EPCs) for 11 of the case study homes improved their energy efficiency rating (EER), indicating default airtightness values used in EPCs used were overestimating the air leakage. Using the co-pressurisation value resulted in an additional EER point. These modest improvements represented a 5%, 8% and 3% reduction in predicted annual carbon emission, space heating demand and fuel bills, respectively. Practice relevance The airtightness of homes is fundamental to their energy efficiency and ventilation requirements. The FPT is commonly used to measure airtightness in homes; however, this research has shown that the FPT can overpredict air leakage in attached homes due to the elevated pressures during the test cause inter-dwelling air exchanges not experienced under non-test conditions. This may affect the accuracy of FPTs in attached homes and the appropriateness of using the FPT result to inform building regulation compliance, ventilation decisions and energy models. The research has implications for FPT standards, testing practitioners and professional bodies, energy modellers, ventilation designers, policymakers, and regulations. The development of further knowledge, industry guidance and protocols is required for inter-dwelling air exchange taking place during the FPT, particularly for different house type, form and construction.
- Open Access
- 28 October 2016
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 38 (3) , 253-268
Accounting for refrigeration heat exchange in energy performance simulations of large food retail buildings
Heat exchange between chilled food storage and conditioned spaces in large food retail stores is not currently required as part of design stage regulatory compliance energy performance models. Existing work has identified that this exchange has a significant impact on store energy demand and subsequently leads to unrealistic assessment of building performance. Research presented in this article uses whole building dynamic thermal simulation models that are calibrated against real store performance data, quantifying the impact of the refrigeration driven heat exchange. Proxy refrigerated units are used to simulate the impact of these units for the sales floor areas. A methodology is presented that allows these models to be simplified with the aim of calculating a realistic process heat exchange for refrigeration and including this in thermal simulation models; a protocol for the measurement of chilled sales areas and their inclusion in the building models is also proposed. It is intended that this modelling approach and the calculated process heat exchange inputs can be used to improve the dynamic thermal simulation of large food retail stores, reduce gaps between predicted and actual performance and provide more representative inputs for design stage and regulatory compliance energy calculations. Practical application: The modelling methodology and research findings presented in the article are of practical use for building energy modelling engineers using dynamic simulation models to design and/or evaluate the energy performance of large food retail stores. The methodology can be used in the design of new facilities or the evaluation of large scale retrofit projects. It is also of practical interest to energy and facility managers within large food retail organisations as it will aid their understanding of applied energy performance models.
- 28 October 2016
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 38 (3) , 253-268
Open AccessAccounting for refrigeration heat exchange in energy performance simulations of large food retail buildings
Heat exchange between chilled food storage and conditioned spaces in large food retail stores is not currently required as part of design stage regulatory compliance energy performance models. Existing work has identified that this exchange has a significant impact on store energy demand and subsequently leads to unrealistic assessment of building performance. Research presented in this article uses whole building dynamic thermal simulation models that are calibrated against real store performance data, quantifying the impact of the refrigeration driven heat exchange. Proxy refrigerated units are used to simulate the impact of these units for the sales floor areas. A methodology is presented that allows these models to be simplified with the aim of calculating a realistic process heat exchange for refrigeration and including this in thermal simulation models; a protocol for the measurement of chilled sales areas and their inclusion in the building models is also proposed. It is intended that this modelling approach and the calculated process heat exchange inputs can be used to improve the dynamic thermal simulation of large food retail stores, reduce gaps between predicted and actual performance and provide more representative inputs for design stage and regulatory compliance energy calculations. Practical application: The modelling methodology and research findings presented in the article are of practical use for building energy modelling engineers using dynamic simulation models to design and/or evaluate the energy performance of large food retail stores. The methodology can be used in the design of new facilities or the evaluation of large scale retrofit projects. It is also of practical interest to energy and facility managers within large food retail organisations as it will aid their understanding of applied energy performance models.