Ugur Topal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ugur Topal has a total of 144 co-authors. Here are the top co-authors by number of shared publications:
Lev Dorosinskii
9 shared publicationsHusnu Ozkan
Natl. Metrol. Inst., TUBITAK‐UME, TR‐41470 Kocaeli, Turk
7 shared publicationsCengiz Birlikseven
TÜBİTAK-UME National Metrology Institute, P.K. 54, 41470 Gebze, Kocaeli, Turkey
6 shared publicationsFatma Alıkma
TUBITAK-UME (National Metrology Institute), Gebze-Kocaeli, Turkey
6 shared publicationsHava Can
TÜBİTAK-UME National Metrology Institute, P.K. 54, 41470 Gebze, Kocaeli, Turkey
6 shared publicationsHuseyin Sozeri
5 shared publications
Latest Publications
- Open Access
Critical Design and Characterization Methodology for a Homemade Three-Axis Fluxgate Magnetometer Measuring Ultra-Low Magnetic Fields
This paper presents the design, fabrication, calibration, and comprehensive characterization of a homemade tri-axial fluxgate magnetometer. The magnetometer, utilizing a ring core configuration, was developed to measure ultra-low magnetic fields with high sensitivity and stability. Critical stages from material selection to sensor geometry optimization are discussed in detail. A series of critical characterization processes were conducted, including zero-field voltage determination, scale factor calculation, resolution measurement, noise analysis, bias assessment, cross-field effect evaluation, temperature dependency, and bandwidth determination. The sensor demonstrated a minimum detectable magnetic field resolution of 2.2 nT with a noise level of 1.1 nT/√Hz at 1 Hz. Temperature dependency tests revealed minimal impact on sensor output with a maximum shift of 120 nT in the range of 60 °C, which was effectively compensated through calibration to less than 5 nT. Additionally, the paper introduces a model function in matrix form to relate the magnetometer’s output voltage to the measured magnetic field, incorporating temperature dependency and cross-field effects. This work highlights the importance of meticulous calibration and optimization in developing fluxgate magnetometers suitable for various applications, from space exploration to biomedical diagnostics.
Open AccessCritical Design and Characterization Methodology for a Homemade Three-Axis Fluxgate Magnetometer Measuring Ultra-Low Magnetic Fields
This paper presents the design, fabrication, calibration, and comprehensive characterization of a homemade tri-axial fluxgate magnetometer. The magnetometer, utilizing a ring core configuration, was developed to measure ultra-low magnetic fields with high sensitivity and stability. Critical stages from material selection to sensor geometry optimization are discussed in detail. A series of critical characterization processes were conducted, including zero-field voltage determination, scale factor calculation, resolution measurement, noise analysis, bias assessment, cross-field effect evaluation, temperature dependency, and bandwidth determination. The sensor demonstrated a minimum detectable magnetic field resolution of 2.2 nT with a noise level of 1.1 nT/√Hz at 1 Hz. Temperature dependency tests revealed minimal impact on sensor output with a maximum shift of 120 nT in the range of 60 °C, which was effectively compensated through calibration to less than 5 nT. Additionally, the paper introduces a model function in matrix form to relate the magnetometer’s output voltage to the measured magnetic field, incorporating temperature dependency and cross-field effects. This work highlights the importance of meticulous calibration and optimization in developing fluxgate magnetometers suitable for various applications, from space exploration to biomedical diagnostics.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (3) , 2749-2756
Optimization of the Temperature Stability of Fluxgate Sensors for Space Applications
Fluxgate magnetometers are widely used in many places for the measurement of weak magnetic field, but are sensitive to variations of sensor temperature. Therefore, their stabilization against temperature variation is required especially for outdoor applications. In this work, temperature dependencies of fluxgate sensors having the cores of one homemade, one commercially obtained finemet alloy, and a commercially obtained supermalloy alloy in ribbon form were examined. It was observed that the heat treatments of the studied cores affect the sensitivity of the sensors in different ways. For instance, while the scale factor of the sensor with the core from in-house prepared finemet ribbon increased from 1.19 MV/T to 3.12 MV/T, the scale factor of the sensor with the supermalloy core increases by 20 times in magnitude (41.6 kV/T to 0.92 MV/T) after heat treatment. Our analysis performed in the temperature interval from −50 °C to +85 °C reveals that temperature dependencies of the sensors also show differences depending on the core material. In addition to differences seen on the temperature dependence of the studied cores, the most stable one was the sensor with the heat treated in-house prepared finemet core. The variation of the scale factor in the 135 °C temperature range was 9.8 %. However, by analyzing the temperature dependences of the scale factors we could decrease the error coming from temperature variations to less than 1.0 % in magnitude of the output signal due to the observed linear dependence between the scale factor and the temperature of this sensor.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (3) , 2749-2756
Optimization of the Temperature Stability of Fluxgate Sensors for Space Applications
Fluxgate magnetometers are widely used in many places for the measurement of weak magnetic field, but are sensitive to variations of sensor temperature. Therefore, their stabilization against temperature variation is required especially for outdoor applications. In this work, temperature dependencies of fluxgate sensors having the cores of one homemade, one commercially obtained finemet alloy, and a commercially obtained supermalloy alloy in ribbon form were examined. It was observed that the heat treatments of the studied cores affect the sensitivity of the sensors in different ways. For instance, while the scale factor of the sensor with the core from in-house prepared finemet ribbon increased from 1.19 MV/T to 3.12 MV/T, the scale factor of the sensor with the supermalloy core increases by 20 times in magnitude (41.6 kV/T to 0.92 MV/T) after heat treatment. Our analysis performed in the temperature interval from −50 °C to +85 °C reveals that temperature dependencies of the sensors also show differences depending on the core material. In addition to differences seen on the temperature dependence of the studied cores, the most stable one was the sensor with the heat treated in-house prepared finemet core. The variation of the scale factor in the 135 °C temperature range was 9.8 %. However, by analyzing the temperature dependences of the scale factors we could decrease the error coming from temperature variations to less than 1.0 % in magnitude of the output signal due to the observed linear dependence between the scale factor and the temperature of this sensor.
- Open Access
- 4 April 2019
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 103 (1) , 21
Effect of Needle-Tract Bleeding on Pneumothorax and Chest Tube Placement Following CT Guided Core Needle Lung Biopsy
Bleeding in the biopsy tract has been studied for its ability to decrease the risk of pneumothorax with indefinite results in the previous studies. To investigate the risk factors for needle-tract bleeding (NTB) and the possible effect of NTB on the pneumothorax and resultant chest tube placement after CT-guided cutting needle biopsy (CT-CNB) of pulmonary lesions. Predictive variables for NTB and the effect of NTB on the development of pneumothorax and consequent chest tube placement were retrospectively determined in 416 patients who had undergone an 18-gauge non-coaxial CT-CNB (338 men and 78 women; average age, 59.3 years). Patient-related parameters were age, gender, patient position, and severity of pulmonary emphysema. Lesion-related variables were size, localization, and contour characteristics of the lesion. Procedure-related variables were the presence of atelectasis, pleural tag, and fissure in the needle-tract, length of the aerated lung parenchyma crossed by needle, needle entry angle, number of pleural punctures, the experience of the operator, and procedure duration. All variables were analyzed by x2 test and logistic regression analysis. NTB was demonstrated in 142 of 421 (33.7%) procedures. The predictive variables of NTB were smaller lesion size (p = 0.011) and greater lesion depth (p = 0.002). In patients without emphysema around the lesion, the pneumothorax developed in 44/190 cases (23.1%) without NTB and in 12/95 procedures (12.6%) with NTB (p < 0.001). NTB may have a preventive effect on pneumothorax development, particularly in the absence of emphysema around the lesion.
- 4 April 2019
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 103 (1) , 21
Open AccessEffect of Needle-Tract Bleeding on Pneumothorax and Chest Tube Placement Following CT Guided Core Needle Lung Biopsy
Bleeding in the biopsy tract has been studied for its ability to decrease the risk of pneumothorax with indefinite results in the previous studies. To investigate the risk factors for needle-tract bleeding (NTB) and the possible effect of NTB on the pneumothorax and resultant chest tube placement after CT-guided cutting needle biopsy (CT-CNB) of pulmonary lesions. Predictive variables for NTB and the effect of NTB on the development of pneumothorax and consequent chest tube placement were retrospectively determined in 416 patients who had undergone an 18-gauge non-coaxial CT-CNB (338 men and 78 women; average age, 59.3 years). Patient-related parameters were age, gender, patient position, and severity of pulmonary emphysema. Lesion-related variables were size, localization, and contour characteristics of the lesion. Procedure-related variables were the presence of atelectasis, pleural tag, and fissure in the needle-tract, length of the aerated lung parenchyma crossed by needle, needle entry angle, number of pleural punctures, the experience of the operator, and procedure duration. All variables were analyzed by x2 test and logistic regression analysis. NTB was demonstrated in 142 of 421 (33.7%) procedures. The predictive variables of NTB were smaller lesion size (p = 0.011) and greater lesion depth (p = 0.002). In patients without emphysema around the lesion, the pneumothorax developed in 44/190 cases (23.1%) without NTB and in 12/95 procedures (12.6%) with NTB (p < 0.001). NTB may have a preventive effect on pneumothorax development, particularly in the absence of emphysema around the lesion.
- Open Access
- 3 September 2018
- Published by Termedia Sp. z.o.o. in Polish Journal of Radiology
- Vol. 83, 407-414
Risk factors of pneumothorax and chest tube placement after computed tomography-guided core needle biopsy of lung lesions: a single-centre experience with 822 biopsies
Purpose: To determine the risk factors of pneumothorax and chest tube placement after computed tomography-guided core needle lung biopsy (CT-CNB).Material and methods: Variables that could increase the risk of pneumothorax and chest tube placement were retrospectively analysed in 822 CT-CNBs conducted with 18-gauge non-coaxial CT-CNB in 813 patients (646 men and 167 women; range: 18-90 years; mean: 59.8 years). Predictor variables were age, gender, patient position, severity of pulmonary emphysema, lesion size and localisation, contour characteristics, presence of atelectasis, pleural tag and fissure in the needle-tract, length of the aerated lung parenchyma crossed by the needle, needle entry angle, number of pleural punctures, experience of the operator, and procedure duration. All variables were investigated by ×2 test and logistic regression analysis.Results: The overall incidence of pneumothorax was 15.4% (127/822). Chest tube placement was required for 22.8% (29/127) of pneumothoraxes. The significant independent variables for pneumothorax were lesions smaller than 3 cm (p = 0.009), supine and lateral decubitus position during the procedure (p < 0.001), greater lesion depth (p = 0.001), severity of pulmonary emphysema (p < 0.001), needle path crossing the fissure (p < 0.001), and a path that skips the atelectasis (p < 0.001) or pleural tag (p < 0.001); those for chest tube placement were prone position (p < 0.001), less experienced operator (p = 0.001), severity of pulmonary emphysema (p < 0.001), and greater lesion depth (p = 0.008).Conclusions: The supine and lateral decubitus position, a needle path that crosses the fissure, and a path that skips the atelectasis or a pleural tag are novel predictors for the development of pneumothorax.
- 3 September 2018
- Published by Termedia Sp. z.o.o. in Polish Journal of Radiology
- Vol. 83, 407-414
Open AccessRisk factors of pneumothorax and chest tube placement after computed tomography-guided core needle biopsy of lung lesions: a single-centre experience with 822 biopsies
Purpose: To determine the risk factors of pneumothorax and chest tube placement after computed tomography-guided core needle lung biopsy (CT-CNB).Material and methods: Variables that could increase the risk of pneumothorax and chest tube placement were retrospectively analysed in 822 CT-CNBs conducted with 18-gauge non-coaxial CT-CNB in 813 patients (646 men and 167 women; range: 18-90 years; mean: 59.8 years). Predictor variables were age, gender, patient position, severity of pulmonary emphysema, lesion size and localisation, contour characteristics, presence of atelectasis, pleural tag and fissure in the needle-tract, length of the aerated lung parenchyma crossed by the needle, needle entry angle, number of pleural punctures, experience of the operator, and procedure duration. All variables were investigated by ×2 test and logistic regression analysis.Results: The overall incidence of pneumothorax was 15.4% (127/822). Chest tube placement was required for 22.8% (29/127) of pneumothoraxes. The significant independent variables for pneumothorax were lesions smaller than 3 cm (p = 0.009), supine and lateral decubitus position during the procedure (p < 0.001), greater lesion depth (p = 0.001), severity of pulmonary emphysema (p < 0.001), needle path crossing the fissure (p < 0.001), and a path that skips the atelectasis (p < 0.001) or pleural tag (p < 0.001); those for chest tube placement were prone position (p < 0.001), less experienced operator (p = 0.001), severity of pulmonary emphysema (p < 0.001), and greater lesion depth (p = 0.008).Conclusions: The supine and lateral decubitus position, a needle path that crosses the fissure, and a path that skips the atelectasis or a pleural tag are novel predictors for the development of pneumothorax.
- 30 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 54 (7) , 1-6
The Sensing Characteristics of Ring-Core Fluxgate Sensors at Temperature Interval of −50 °C to +85 °C
Fluxgate magnetometers are widely used in many places for the measurement of weak magnetic field, but sensitive to variations in sensor temperature. Therefore, their stabilization against temperature is required especially for outdoor applications. In this paper, temperature dependencies of fluxgate sensors using four cobalt-based cores, two homemade, and two commercially obtained were analyzed at temperature interval of -50 °C to +85 °C in the climatic chamber. In addition to differences seen on the temperature dependence of the studied cores, the most stable one was the sensor using Co₆₅Fe₆Cr₇Si₈B₁₄ core. Although the variation of the scale factor in the 135 °C temperature range was 17% in magnitude, it was decreased to 6% with a serial resistor connected to the pick-up coil, where the sensor signal is induced by measured dc field. By specifying the scale factor versus temperature dependence curves, we could decrease the error coming from temperature variations to less than 2%. Experimental results reveal that the sensors cored with Vitrovac6025 and Metglas2714A ribbons can also be preferred when they are evaluated in terms of both temperature dependence and noise levels.
- 30 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 54 (7) , 1-6
The Sensing Characteristics of Ring-Core Fluxgate Sensors at Temperature Interval of −50 °C to +85 °C
Fluxgate magnetometers are widely used in many places for the measurement of weak magnetic field, but sensitive to variations in sensor temperature. Therefore, their stabilization against temperature is required especially for outdoor applications. In this paper, temperature dependencies of fluxgate sensors using four cobalt-based cores, two homemade, and two commercially obtained were analyzed at temperature interval of -50 °C to +85 °C in the climatic chamber. In addition to differences seen on the temperature dependence of the studied cores, the most stable one was the sensor using Co₆₅Fe₆Cr₇Si₈B₁₄ core. Although the variation of the scale factor in the 135 °C temperature range was 17% in magnitude, it was decreased to 6% with a serial resistor connected to the pick-up coil, where the sensor signal is induced by measured dc field. By specifying the scale factor versus temperature dependence curves, we could decrease the error coming from temperature variations to less than 2%. Experimental results reveal that the sensors cored with Vitrovac6025 and Metglas2714A ribbons can also be preferred when they are evaluated in terms of both temperature dependence and noise levels.
- 1 March 2017
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 255, 94-103
Systematic optimization of the sensing properties of ring-core fluxgate sensors with different core diameters and materials
- 1 March 2017
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 255, 94-103
Systematic optimization of the sensing properties of ring-core fluxgate sensors with different core diameters and materials
- 23 August 2016
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 30 (8) , 2329-2333
Magnetic and Low DC Field Sensing Analysis of Cobalt-Doped YBCO Superconductors as the Core of Fluxgate-Type Sensors
- 23 August 2016
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 30 (8) , 2329-2333
Magnetic and Low DC Field Sensing Analysis of Cobalt-Doped YBCO Superconductors as the Core of Fluxgate-Type Sensors
- 17 August 2016
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 30 (12) , 3555-3557
A Comparative Study for Optimization of Sensitivity and Noise Levels in Race-Track Sensors
- 17 August 2016
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 30 (12) , 3555-3557
A Comparative Study for Optimization of Sensitivity and Noise Levels in Race-Track Sensors
- 17 August 2016
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 30 (11) , 3257-3261
Fabrication of Fluxgate Sensor Heads by Milling with a Circuit Board Plotter and Influence of Core Annealing Conditions on Sensor Performance
- 17 August 2016
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 30 (11) , 3257-3261
Fabrication of Fluxgate Sensor Heads by Milling with a Circuit Board Plotter and Influence of Core Annealing Conditions on Sensor Performance