Crescenzo Petrone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Crescenzo Petrone has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Gennaro Magliulo
University of Naples Federico II
13 shared publications - Gaetano Manfredi
University of Naples Federico II
11 shared publications G. Magliulo
Department of Structures for Engineering and Architecture, University of Naples Federico II, Naples, Italy
7 shared publications- Giuseppe Maddaloni
Department of Engineering (DING), University of Sannio, Piazza Roma, 82100 Benevento, Italy
7 shared publications - Luigi Di Sarno
University of Liverpool
5 shared publications Pauline Lopez
Product Development Department Etex Dry Co 500 Rue Marcel Demonque Avignon 84915 France
5 shared publications
Latest Publications
- 9 November 2018
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 22 (sup2) , 105-139
Modeling and Seismic Response Analysis of Italian Code-Conforming Reinforced Concrete Buildings
This study investigates the seismic response of reinforced concrete buildings designed according to the current Italian building code. Number of stories, site hazard, presence and distribution of masonry infill panels, and type of lateral resisting system are the key investigated parameters. The main issues related to design and modeling are discussed. Two Limit States are considered, namely Global Collapse and Usability-Preventing Damage. The main aim of the study is a comparison between the seismic response of the buildings, investigated through nonlinear static and dynamic analyses. Irregularity in the distribution of infill panels and site hazard emerge as the most influential parameters.
- 9 November 2018
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 22 (sup2) , 105-139
Modeling and Seismic Response Analysis of Italian Code-Conforming Reinforced Concrete Buildings
This study investigates the seismic response of reinforced concrete buildings designed according to the current Italian building code. Number of stories, site hazard, presence and distribution of masonry infill panels, and type of lateral resisting system are the key investigated parameters. The main issues related to design and modeling are discussed. Two Limit States are considered, namely Global Collapse and Usability-Preventing Damage. The main aim of the study is a comparison between the seismic response of the buildings, investigated through nonlinear static and dynamic analyses. Irregularity in the distribution of infill panels and site hazard emerge as the most influential parameters.
- 20 January 2017
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 46 (10) , 1599-1624
Shake table tests on standard and innovative temporary partition walls
Summary: Shake table tests are performed on temporary internal partitions for office buildings. Four different specimens are tested. A steel frame is designed to exhibit relative displacements which typically occur at a given story of ordinary buildings. Four different partition walls are tested simultaneously for each specimen typology. This allows investigating the influence of an innovative device on the seismic performance of the tested components. The innovative device avoids the unhooking of the panels from the supporting studs. Several shake table tests are performed subjecting the specimens to interstory drift ratios up to 1.57%. Both the hysteretic curves and the natural frequency trend highlight that the partitions do not contribute to the lateral stiffness of the test setup. The damping ratio increases after the partition walls are installed within the test frame, causing a beneficial effect in the dynamic response. Minor damage state occurs for interstory drift ratio (IDR) in the range 0.41–0.65% in standard specimens, whereas moderate and major damage states are attained for IDR in the range 0.51–0.95%. Significant increase of collapse IDR is recorded with the introduction of the innovative device, up to IDR larger than 1.45%. It can be therefore concluded that a simple innovative device is defined, which significantly improves the seismic performance of the tested specimen. Copyright © 2017 John Wiley & Sons, Ltd.
- 20 January 2017
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 46 (10) , 1599-1624
Shake table tests on standard and innovative temporary partition walls
Summary: Shake table tests are performed on temporary internal partitions for office buildings. Four different specimens are tested. A steel frame is designed to exhibit relative displacements which typically occur at a given story of ordinary buildings. Four different partition walls are tested simultaneously for each specimen typology. This allows investigating the influence of an innovative device on the seismic performance of the tested components. The innovative device avoids the unhooking of the panels from the supporting studs. Several shake table tests are performed subjecting the specimens to interstory drift ratios up to 1.57%. Both the hysteretic curves and the natural frequency trend highlight that the partitions do not contribute to the lateral stiffness of the test setup. The damping ratio increases after the partition walls are installed within the test frame, causing a beneficial effect in the dynamic response. Minor damage state occurs for interstory drift ratio (IDR) in the range 0.41–0.65% in standard specimens, whereas moderate and major damage states are attained for IDR in the range 0.51–0.95%. Significant increase of collapse IDR is recorded with the introduction of the innovative device, up to IDR larger than 1.45%. It can be therefore concluded that a simple innovative device is defined, which significantly improves the seismic performance of the tested specimen. Copyright © 2017 John Wiley & Sons, Ltd.
- 1 January 2017
- Published by ECCOMAS
- p. 2926-2936
SEISMIC FRAGILITY OF FREESTANDING BUILDINGS CONTENTS MODELLED AS RIGID BLOCKS
- 1 January 2017
- Published by ECCOMAS
- p. 2926-2936
SEISMIC FRAGILITY OF FREESTANDING BUILDINGS CONTENTS MODELLED AS RIGID BLOCKS
- 1 November 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 28 (11)
Mechanical Properties of Plasterboards: Experimental Tests and Statistical Analysis
Plasterboard components are widely used in current buildings worldwide. Despite their extensive use, the lack of a comprehensive test campaign on plasterboards in current literature is noted. An extensive test campaign consisting of 302 tests on plasterboards is performed both in tension and compression. A set of five plasterboard typologies is selected. The tests are performed in two different load directions: parallel or transversal to the direction of production. Tensile strength of the boards was systematically smaller than compressive strength, whereas elastic modulus values in compression and in tension are similar. Two different regression laws are defined for compression and tension behavior. An orthotropic behavior was exhibited in cases where the boards are loaded in tension. The significant influence of board thickness on their mechanical properties was also highlighted. Finally, the most appropriate probability distribution function was estimated for several mechanical parameters, and ...
- 1 November 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 28 (11)
Mechanical Properties of Plasterboards: Experimental Tests and Statistical Analysis
Plasterboard components are widely used in current buildings worldwide. Despite their extensive use, the lack of a comprehensive test campaign on plasterboards in current literature is noted. An extensive test campaign consisting of 302 tests on plasterboards is performed both in tension and compression. A set of five plasterboard typologies is selected. The tests are performed in two different load directions: parallel or transversal to the direction of production. Tensile strength of the boards was systematically smaller than compressive strength, whereas elastic modulus values in compression and in tension are similar. Two different regression laws are defined for compression and tension behavior. An orthotropic behavior was exhibited in cases where the boards are loaded in tension. The significant influence of board thickness on their mechanical properties was also highlighted. Finally, the most appropriate probability distribution function was estimated for several mechanical parameters, and ...
- Open Access
- 25 October 2016
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 15 (4) , 1609-1633
Numerical modelling and fragility assessment of typical freestanding building contents
- 25 October 2016
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 15 (4) , 1609-1633
Open AccessNumerical modelling and fragility assessment of typical freestanding building contents
- 1 March 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Engineering Mechanics
- Vol. 142 (3)
Dynamic Analysis of Mooring Cables with Application to Floating Offshore Wind Turbines
Floating offshore wind turbines are recently being considered widely for adoption in the wind power industry, attracting interest of several researchers and calling for the development of appropriate computational models and techniques. In the present work, a nonlinear finite-element formulation is proposed and applied to the static and dynamic analysis of mooring cables. Numerical examples are presented, and in particular, a mooring cable typically used for floating offshore wind turbines is analyzed. Hydrodynamic effects on the cable are accounted for using the Morison approach. A key enabling development here is an algorithmic tangent stiffness operator including hydrodynamic coupling. Numerical results also suggest that previous empirical hydrodynamic coefficients could be obtained by fully coupled fluid–structure interaction. Convergence-rate and energy-balance calculations have been used to demonstrate the accuracy of computed solutions. The introduction of the developed cable model in a fra...
- 1 March 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Engineering Mechanics
- Vol. 142 (3)
Dynamic Analysis of Mooring Cables with Application to Floating Offshore Wind Turbines
Floating offshore wind turbines are recently being considered widely for adoption in the wind power industry, attracting interest of several researchers and calling for the development of appropriate computational models and techniques. In the present work, a nonlinear finite-element formulation is proposed and applied to the static and dynamic analysis of mooring cables. Numerical examples are presented, and in particular, a mooring cable typically used for floating offshore wind turbines is analyzed. Hydrodynamic effects on the cable are accounted for using the Morison approach. A key enabling development here is an algorithmic tangent stiffness operator including hydrodynamic coupling. Numerical results also suggest that previous empirical hydrodynamic coefficients could be obtained by fully coupled fluid–structure interaction. Convergence-rate and energy-balance calculations have been used to demonstrate the accuracy of computed solutions. The introduction of the developed cable model in a fra...
- 23 November 2015
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 14 (3) , 747-767
Floor response spectra in RC frame structures designed according to Eurocode 8
- 23 November 2015
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 14 (3) , 747-767
Floor response spectra in RC frame structures designed according to Eurocode 8
- 1 October 2015
- Published by Elsevier in Engineering Structures
- Vol. 100, 442-454
Dynamic properties of typical consultation room medical components
- 1 October 2015
- Published by Elsevier in Engineering Structures
- Vol. 100, 442-454
Dynamic properties of typical consultation room medical components
- 14 July 2015
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 44 (14) , 2589-2606
Seismic fragility of plasterboard partitions via in‐plane quasi‐static tests
Summary: The seismic damage of internal partitions may cause significant earthquake loss; this phenomenon is caused by (a) their tendency to exhibit damage for low demand levels and (b) the consequent loss of inventory and breakdown that their collapse can cause.Quasi‐static tests are performed on six 5‐m‐high plasterboard internal partitions, which represent typical partitions in industrial and commercial buildings in the European area. A steel test setup is designed to transfer the load, which is provided by the actuator, to the partition. The testing protocol provided by Federal Emergency Management Agency (FEMA) 461 is adopted for the quasi‐static tests.The typical failure mode of the specimens is the buckling of a steel stud, which involves the boards that are attached to the buckled stud. The buckling failure usually concentrates across the plasterboard horizontal joints. A frictional behavior is exhibited for low demand levels, whereas a pinched behavior is shown for moderate‐to‐high demand levels.The interstory drift ratios required to reach a given damage limit state are evaluated using a predefined damage scheme. Based on the experimental data, the fragility curves for three different damage states (DS1, DS2, and DS3) are estimated. The fragility curve yields median interstory drift ratio values of 0.28%, 0.81%, and 2.05% and logarithmic standard deviations of 0.39, 0.42, and 0.46 for DS1, DS2, and DS3, respectively. Copyright © 2015 John Wiley & Sons, Ltd.
- 14 July 2015
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 44 (14) , 2589-2606
Seismic fragility of plasterboard partitions via in‐plane quasi‐static tests
Summary: The seismic damage of internal partitions may cause significant earthquake loss; this phenomenon is caused by (a) their tendency to exhibit damage for low demand levels and (b) the consequent loss of inventory and breakdown that their collapse can cause.Quasi‐static tests are performed on six 5‐m‐high plasterboard internal partitions, which represent typical partitions in industrial and commercial buildings in the European area. A steel test setup is designed to transfer the load, which is provided by the actuator, to the partition. The testing protocol provided by Federal Emergency Management Agency (FEMA) 461 is adopted for the quasi‐static tests.The typical failure mode of the specimens is the buckling of a steel stud, which involves the boards that are attached to the buckled stud. The buckling failure usually concentrates across the plasterboard horizontal joints. A frictional behavior is exhibited for low demand levels, whereas a pinched behavior is shown for moderate‐to‐high demand levels.The interstory drift ratios required to reach a given damage limit state are evaluated using a predefined damage scheme. Based on the experimental data, the fragility curves for three different damage states (DS1, DS2, and DS3) are estimated. The fragility curve yields median interstory drift ratio values of 0.28%, 0.81%, and 2.05% and logarithmic standard deviations of 0.39, 0.42, and 0.46 for DS1, DS2, and DS3, respectively. Copyright © 2015 John Wiley & Sons, Ltd.
- 1 January 2015
- Published by ECCOMAS
- p. 2167-2176
SEISMIC PERFORMANCE OF HOLLOW BRICK INTERNAL PARTITIONS
- 1 January 2015
- Published by ECCOMAS
- p. 2167-2176
SEISMIC PERFORMANCE OF HOLLOW BRICK INTERNAL PARTITIONS