Abstract
Summary: The seismic damage of internal partitions may cause significant earthquake loss; this phenomenon is caused by (a) their tendency to exhibit damage for low demand levels and (b) the consequent loss of inventory and breakdown that their collapse can cause.Quasi‐static tests are performed on six 5‐m‐high plasterboard internal partitions, which represent typical partitions in industrial and commercial buildings in the European area. A steel test setup is designed to transfer the load, which is provided by the actuator, to the partition. The testing protocol provided by Federal Emergency Management Agency (FEMA) 461 is adopted for the quasi‐static tests.The typical failure mode of the specimens is the buckling of a steel stud, which involves the boards that are attached to the buckled stud. The buckling failure usually concentrates across the plasterboard horizontal joints. A frictional behavior is exhibited for low demand levels, whereas a pinched behavior is shown for moderate‐to‐high demand levels.The interstory drift ratios required to reach a given damage limit state are evaluated using a predefined damage scheme. Based on the experimental data, the fragility curves for three different damage states (DS1, DS2, and DS3) are estimated. The fragility curve yields median interstory drift ratio values of 0.28%, 0.81%, and 2.05% and logarithmic standard deviations of 0.39, 0.42, and 0.46 for DS1, DS2, and DS3, respectively. Copyright © 2015 John Wiley & Sons, Ltd.Keywords
Funding Information
- Italian Department of Civil Protection
- Siniat
This publication has 19 references indexed in Scilit:
- The Emilia Earthquake: Seismic Performance of Precast Reinforced Concrete BuildingsEarthquake Spectra, 2014
- Full‐scale shaking table test of a base‐isolated medical facility subjected to vertical motionsEarthquake Engineering & Structural Dynamics, 2013
- Shake table tests for seismic assessment of suspended continuous ceilingsBulletin of Earthquake Engineering, 2012
- Shake table tests on clutter levels of typical medicine shelves and contents subjected to earthquakesEarthquake Engineering & Structural Dynamics, 2011
- Seismic Fragility of Suspended Ceiling SystemsEarthquake Spectra, 2007
- Seismic performance evaluation of non‐structural components: drywall partitionsEarthquake Engineering & Structural Dynamics, 2006
- Performance‐based seismic engineering: the need for a reliable conceptual comprehensive approachEarthquake Engineering & Structural Dynamics, 2001
- Seismic Design of Secondary Structures: State of the ArtJournal of Structural Engineering, 1997
- On the Kolmogorov-Smirnov Test for Normality with Mean and Variance UnknownJournal of the American Statistical Association, 1967