Juuso T. Korhonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Juuso T. Korhonen has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Victor Hugo Souza
Department of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland
8 shared publications - Jaakko O. Nieminen
Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
7 shared publications - Risto Juhani Ilmoniemi
Aalto University
7 shared publications - Janne Ruokolainen
Department of Applied Physics, School of Science, Aalto University, Espoo 02150, Finland
6 shared publications - Olli Ikkala
Aalto University
6 shared publications - Heikki Sinisalo
Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
5 shared publications
Latest Publications
- Open Access
- 2 May 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Multi-coil TMS for preclinical applications in ultra-high-field MRI
Monitoring cortical responses to neuromodulation on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here, we report on a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, multi-coil transcranial magnetic stimulation (mTMS) is delivered with a 2-coil array, and the MRI signal is measured with a radiofrequency coil. The mTMS can change the stimulus orientation with 1° resolution in a millisecond. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. The mTMS system was successfully implemented and tested with the small-animal MRI, showing minimal interference with B0 and B1+ fields and uncompromised image quality. A delay of 40 ms between the stimulation pulse and fMRI acquisition—similar or even shorter than those previously described in humans—led to artifact-free images. Concurrent electronically targeted brain stimulation and neuroimaging provides a valuable tool for exploring whole-brain network functions, endorsing more efficient treatment protocols.
- 2 May 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Open AccessMulti-coil TMS for preclinical applications in ultra-high-field MRI
Monitoring cortical responses to neuromodulation on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here, we report on a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, multi-coil transcranial magnetic stimulation (mTMS) is delivered with a 2-coil array, and the MRI signal is measured with a radiofrequency coil. The mTMS can change the stimulus orientation with 1° resolution in a millisecond. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. The mTMS system was successfully implemented and tested with the small-animal MRI, showing minimal interference with B0 and B1+ fields and uncompromised image quality. A delay of 40 ms between the stimulation pulse and fMRI acquisition—similar or even shorter than those previously described in humans—led to artifact-free images. Concurrent electronically targeted brain stimulation and neuroimaging provides a valuable tool for exploring whole-brain network functions, endorsing more efficient treatment protocols.
- Open Access
- 14 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175001
Modeling the stress and forces on multi-channel TMS coil arrays in high-field MRI scanners
Transcranial magnetic stimulation (TMS) is a non-invasive method for stimulating the cortex. Concurrent functional magnetic resonance imaging can show changes in TMS-induced activity in the whole brain, with the potential to inform brain function research and to guide the development of TMS therapy. However, the interaction of the strong current pulses in the TMS coil in the static main magnetic field of the MRI produces high Lorentz forces, which may damage the coil enclosure and compromise the patient’s safety. We studied the time-dependent mechanical behavior and durability of two multi-locus TMS (mTMS) coil arrays inside a high-field MRI bore with finite element modeling. In addition, coil arrays were built and tested based on the simulation results. We found that the current pulses produce shock waves and time-dependent stress distribution in the coil plates. The intensity and location of the maximum stress depend on the current waveform, the coil combination, and the transducer orientation relative to the MRI magnetic field. We found that 30% glass-fiber-filled polyamide is the most durable material out of the six options studied. In addition, novel insights for more durable TMS coil designs were obtained. Our study contributes to a comprehensive understanding of the underlying mechanisms responsible for the structural failure of mTMS coil arrays during stimulation within high static magnetic fields. This knowledge is essential for developing mechanically stable and safe mTMS-MRI transducers.
- 14 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175001
Open AccessModeling the stress and forces on multi-channel TMS coil arrays in high-field MRI scanners
Transcranial magnetic stimulation (TMS) is a non-invasive method for stimulating the cortex. Concurrent functional magnetic resonance imaging can show changes in TMS-induced activity in the whole brain, with the potential to inform brain function research and to guide the development of TMS therapy. However, the interaction of the strong current pulses in the TMS coil in the static main magnetic field of the MRI produces high Lorentz forces, which may damage the coil enclosure and compromise the patient’s safety. We studied the time-dependent mechanical behavior and durability of two multi-locus TMS (mTMS) coil arrays inside a high-field MRI bore with finite element modeling. In addition, coil arrays were built and tested based on the simulation results. We found that the current pulses produce shock waves and time-dependent stress distribution in the coil plates. The intensity and location of the maximum stress depend on the current waveform, the coil combination, and the transducer orientation relative to the MRI magnetic field. We found that 30% glass-fiber-filled polyamide is the most durable material out of the six options studied. In addition, novel insights for more durable TMS coil designs were obtained. Our study contributes to a comprehensive understanding of the underlying mechanisms responsible for the structural failure of mTMS coil arrays during stimulation within high static magnetic fields. This knowledge is essential for developing mechanically stable and safe mTMS-MRI transducers.
- Open Access
A multi-channel TMS system enabling accurate stimulus orientation control during concurrent ultra-high-field MRI for preclinical applications
Monitoring cortical responses to neuromodulation protocols on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here we report a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, transcranial magnetic stimulation is delivered with a set of two coils and the MRI signals are recorded with a radiofrequency coil. The coil set provides millisecond-scale electronic control of the stimulus orientation with 1° resolution. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. We show that the stimulation pulses do not affect the anatomical imaging quality, and imaging signals are disrupted only if recorded before 10 ms after pulse delivery. Concurrent electronically targeted brain stimulation and neuroimaging sets the stage for the causal investigation of whole-brain network functions, endorsing more efficient treatment protocols.
Open AccessA multi-channel TMS system enabling accurate stimulus orientation control during concurrent ultra-high-field MRI for preclinical applications
Monitoring cortical responses to neuromodulation protocols on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here we report a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, transcranial magnetic stimulation is delivered with a set of two coils and the MRI signals are recorded with a radiofrequency coil. The coil set provides millisecond-scale electronic control of the stimulus orientation with 1° resolution. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. We show that the stimulation pulses do not affect the anatomical imaging quality, and imaging signals are disrupted only if recorded before 10 ms after pulse delivery. Concurrent electronically targeted brain stimulation and neuroimaging sets the stage for the causal investigation of whole-brain network functions, endorsing more efficient treatment protocols.
- Open Access
- 22 May 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-11
DELMEP: a deep learning algorithm for automated annotation of motor evoked potential latencies
The analysis of motor evoked potentials (MEPs) generated by transcranial magnetic stimulation (TMS) is crucial in research and clinical medical practice. MEPs are characterized by their latency and the treatment of a single patient may require the characterization of thousands of MEPs. Given the difficulty of developing reliable and accurate algorithms, currently the assessment of MEPs is performed with visual inspection and manual annotation by a medical expert; making it a time-consuming, inaccurate, and error-prone process. In this study, we developed DELMEP, a deep learning-based algorithm to automate the estimation of MEP latency. Our algorithm resulted in a mean absolute error of about 0.5 ms and an accuracy that was practically independent of the MEP amplitude. The low computational cost of the DELMEP algorithm allows employing it in on-the-fly characterization of MEPs for brain-state-dependent and closed-loop brain stimulation protocols. Moreover, its learning ability makes it a particularly promising option for artificial-intelligence-based personalized clinical applications.
- 22 May 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-11
Open AccessDELMEP: a deep learning algorithm for automated annotation of motor evoked potential latencies
The analysis of motor evoked potentials (MEPs) generated by transcranial magnetic stimulation (TMS) is crucial in research and clinical medical practice. MEPs are characterized by their latency and the treatment of a single patient may require the characterization of thousands of MEPs. Given the difficulty of developing reliable and accurate algorithms, currently the assessment of MEPs is performed with visual inspection and manual annotation by a medical expert; making it a time-consuming, inaccurate, and error-prone process. In this study, we developed DELMEP, a deep learning-based algorithm to automate the estimation of MEP latency. Our algorithm resulted in a mean absolute error of about 0.5 ms and an accuracy that was practically independent of the MEP amplitude. The low computational cost of the DELMEP algorithm allows employing it in on-the-fly characterization of MEPs for brain-state-dependent and closed-loop brain stimulation protocols. Moreover, its learning ability makes it a particularly promising option for artificial-intelligence-based personalized clinical applications.
- Open Access
- 1 January 2022
- Published by Elsevier in Brain Stimulation
- Vol. 15 (1) , 116-124
Multi-locus transcranial magnetic stimulation system for electronically targeted brain stimulation
- 1 January 2022
- Published by Elsevier in Brain Stimulation
- Vol. 15 (1) , 116-124
Open AccessMulti-locus transcranial magnetic stimulation system for electronically targeted brain stimulation
- Open Access
- 1 November 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (6) , 1606
The impulse noise of TMS inside a 3 T and 9.4 T MRI
- 1 November 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (6) , 1606
Open AccessThe impulse noise of TMS inside a 3 T and 9.4 T MRI
- Open Access
- 1 November 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (6) , 1750
Agile TMS: A multi-locus system for rapid and automatic spatial targeting and mapping
- 1 November 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (6) , 1750
Open AccessAgile TMS: A multi-locus system for rapid and automatic spatial targeting and mapping
- Open Access
Multi-locus transcranial magnetic stimulation system for electronically targeted brain stimulation
Background Transcranial magnetic stimulation (TMS) allows non-invasive stimulation of the cortex. In multi-locus TMS (mTMS), the stimulating electric field (E-field) is controlled electronically without coil movement by adjusting currents in the coils of a transducer. Objective To develop an mTMS system that allows adjusting the location and orientation of the E-field maximum within a cortical region. Methods We designed and manufactured a planar 5-coil mTMS transducer to allow controlling the maximum of the induced E-field within a cortical region approximately 30 mm in diameter. We developed electronics with a design consisting of independently controlled H-bridge circuits to drive up to six TMS coils. To control the hardware, we programmed software that runs on a field-programmable gate array and a computer. To induce the desired E-field in the cortex, we developed an optimization method to calculate the currents needed in the coils. We characterized the mTMS system and conducted a proof-of-concept motor-mapping experiment on a healthy volunteer. In the motor mapping, we kept the transducer placement fixed while electronically shifting the E-field maximum on the precentral gyrus and measuring electromyography from the contralateral hand. Results The transducer consists of an oval coil, two figure-of-eight coils, and two four-leaf-clover coils stacked on top of each other. The technical characterization indicated that the mTMS system performs as designed. The measured motor evoked potential amplitudes varied consistently as a function of the location of the E-field maximum. Conclusion The developed mTMS system enables electronically targeted brain stimulation within a cortical region.
Open AccessMulti-locus transcranial magnetic stimulation system for electronically targeted brain stimulation
Background Transcranial magnetic stimulation (TMS) allows non-invasive stimulation of the cortex. In multi-locus TMS (mTMS), the stimulating electric field (E-field) is controlled electronically without coil movement by adjusting currents in the coils of a transducer. Objective To develop an mTMS system that allows adjusting the location and orientation of the E-field maximum within a cortical region. Methods We designed and manufactured a planar 5-coil mTMS transducer to allow controlling the maximum of the induced E-field within a cortical region approximately 30 mm in diameter. We developed electronics with a design consisting of independently controlled H-bridge circuits to drive up to six TMS coils. To control the hardware, we programmed software that runs on a field-programmable gate array and a computer. To induce the desired E-field in the cortex, we developed an optimization method to calculate the currents needed in the coils. We characterized the mTMS system and conducted a proof-of-concept motor-mapping experiment on a healthy volunteer. In the motor mapping, we kept the transducer placement fixed while electronically shifting the E-field maximum on the precentral gyrus and measuring electromyography from the contralateral hand. Results The transducer consists of an oval coil, two figure-of-eight coils, and two four-leaf-clover coils stacked on top of each other. The technical characterization indicated that the mTMS system performs as designed. The measured motor evoked potential amplitudes varied consistently as a function of the location of the E-field maximum. Conclusion The developed mTMS system enables electronically targeted brain stimulation within a cortical region.
- 1 October 2015
- Published by Elsevier in Fusion Engineering and Design
- Vol. 96-97, 101-106
Feasibility of arc-discharge and plasma-sputtering methods in cleaning plasma-facing and diagnostics components of fusion reactors
- 1 October 2015
- Published by Elsevier in Fusion Engineering and Design
- Vol. 96-97, 101-106
Feasibility of arc-discharge and plasma-sputtering methods in cleaning plasma-facing and diagnostics components of fusion reactors
- 11 April 2013
- Published by Springer Nature in Cellulose
- Vol. 20 (3) , 1459-1468
Nanofibrillated cellulose/carboxymethyl cellulose composite with improved wet strength
- 11 April 2013
- Published by Springer Nature in Cellulose
- Vol. 20 (3) , 1459-1468
Nanofibrillated cellulose/carboxymethyl cellulose composite with improved wet strength