Modeling the stress and forces on multi-channel TMS coil arrays in high-field MRI scanners
Authors:
- Maria A KoponenMKMaria A Koponen
- Juuso T KorhonenJKJuuso T Korhonen
- José A Vilchez MembrillaJMJosé A Vilchez Membrilla
- Heikki SinisaloHSHeikki Sinisalo
- Jaakko PaasonenJPJaakko Paasonen
- Clemente Cobos SánchezCSClemente Cobos Sánchez
- Olli GröhnOGOlli Gröhn
- Risto J IlmoniemiRIRisto J Ilmoniemi
- Victor H SouzaVictor H Souza
Open Access
- 14 August 2024
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175001
Abstract
Transcranial magnetic stimulation (TMS) is a non-invasive method for stimulating the cortex. Concurrent functional magnetic resonance imaging can show changes in TMS-induced activity in the whole brain, with the potential to inform brain function research and to guide the development of TMS therapy. However, the interaction of the strong current pulses in the TMS coil in the static main magnetic field of the MRI produces high Lorentz forces, which may damage the coil enclosure and compromise the patient’s safety. We studied the time-dependent mechanical behavior and durability of two multi-locus TMS (mTMS) coil arrays inside a high-field MRI bore with finite element modeling. In addition, coil arrays were built and tested based on the simulation results. We found that the current pulses produce shock waves and time-dependent stress distribution in the coil plates. The intensity and location of the maximum stress depend on the current waveform, the coil combination, and the transducer orientation relative to the MRI magnetic field. We found that 30% glass-fiber-filled polyamide is the most durable material out of the six options studied. In addition, novel insights for more durable TMS coil designs were obtained. Our study contributes to a comprehensive understanding of the underlying mechanisms responsible for the structural failure of mTMS coil arrays during stimulation within high static magnetic fields. This knowledge is essential for developing mechanically stable and safe mTMS-MRI transducers.Keywords
Funding Information
- Jane ja Aatos Erkon Säätiö
- H2020 European Research Council (810377)
- Research Council of Finland (294625)
- Emil Aaltosen Säätiö
This publication has 18 references indexed in Scilit:
- A novel whole-head RF coil design tailored for concurrent multichannel brain stimulation and imaging at 3TBrain Stimulation, 2023
- Design of coil holder for the improved maneuvering in concurrent TMS-MRIBrain Stimulation, 2023
- TMS with fast and accurate electronic control: Measuring the orientation sensitivity of corticomotor pathwaysBrain Stimulation, 2022
- Multi-locus transcranial magnetic stimulation system for electronically targeted brain stimulationBrain Stimulation, 2022
- Concurrent TMS-fMRI for causal network perturbation and proof of target engagementNeuroImage, 2021
- Transcranial Magnetic Stimulation as Treatment in Multiple Neurologic ConditionsCurrent Neurology and Neuroscience Reports, 2020
- Anomaly detection by robust statisticsWIREs Data Mining and Knowledge Discovery, 2017
- Minimum-energy Coils for Transcranial Magnetic Stimulation: Application to Focal StimulationBrain Stimulation, 2015
- New coil positioning method for interleaved transcranial magnetic stimulation (TMS)/functional MRI (fMRI) and its validation in a motor cortex studyJournal of Magnetic Resonance Imaging, 2008
- Expert systems and finite element structural analysis — a reviewSādhanā, 1992