JGJorge Garcia-Sucerquia

Jorge Garcia-Sucerquia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jorge Garcia-Sucerquia has a total of 175 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    µ12: Cost-effective DIY microscope

    by Diego A Londono, Carlos A Buitrago-Duque, Jorge Garcia-Sucerquia


  • Rapid and Selective Microplastics Detection in Water Using a Cost-Effective CS–TA-Functionalized E-SMS Optical Fiber Sensor

    by Arturo Gaviria-Calderón, Brayan Patiño-Jurado, Rodrigo Acuna Herrera, Pedro Torres, Jorge Garcia-Sucerquia

    Microplastic contamination in aquatic environments poses a persistent analytical challenge due to the minute size and low environmental concentrations of the plastic particles originating from various sources, including the degradation of large plastic debris, intentionally manufactured microbeads, and synthetic fibers. Among the different types of polymers, polyethylene (PE) stands out as one of the most widely produced plastics around the world and one of the main contributors to microplastic pollution in aquatic environments due to its extensive use in packaging materials and disposable products. To contribute to the development of practical and accessible monitoring tools, in this work we present a cost-effective optical fiber sensor for the selective detection of polyethylene (PE) microplastics. The sensor device is based on an etched singlemode–multimode–singlemode (E-SMS) fiber structure, functionalized with a chitosan–tannic acid (CS–TA) conjugate on the fiber surface to exploit the chemical affinity between the CS–TA matrix and PE. The E-SMS structure was fabricated by splicing two single-mode fibers to a 15 mm multimode fiber segment and etched with hydrofluoric acid. Experimental evaluations over a broad concentration range (0.001 to 1000 ppm) revealed a robust, concentration-dependent response. Performance metrics include a sensitivity of 3.92 nm/μg/mL and a detection limit of 0.01 μg/mL (10 ppb). By combining high selectivity with a simplified fabrication process, this CS–TA-functionalized the sensor provides a fast, sensitive, selective, and cost-effective platform for microplastic monitoring in water.

  • Open Access

    µ12: cost-effective DIY microscope

    by Jorge Garcia-Sucerquia, Diego Londono, Carlos Buitrago-Duque

    The widespread adoption of rapid prototyping technologies has enabled the development of numerous, easily implementable solutions across nearly every area of science and engineering. Microscopy, because of its fundamental importance in both life and materials sciences, has particularly benefited from this trend. As a result, the literature now features a large variety of microscope designs that can be assembled at relatively low cost or even built at home. While some proposals rely on conventional microscope objectives and eyepieces, increasing their cost, others sacrifice optical performance to uphold the do-it-yourself (DIY) and low-cost promises.In this work, we present a DIY bright-field microscope that employs M12 lenses assembled into a modular 3D-printed platform to build a competitive optical device, hereafter referred to as µ12. The M12 lenses, arranged in a telecentric configuration, enable a cost-effective microscope with near diffraction-limited performance and a flat field of view. The µ12 supports both handheld and desktop operation, combining a compact optical head, interchangeable reversed M12 objectives, integrated high-intensity LED illumination, and a manual X-Y-Z stage. The imaging capabilities of the µ12 are compared to those of a high-end research-grade commercial microscope, demonstrating a highly competitive performance despite its significantly reduced cost. The proposed microscope is benchmarked with both resolution test targets and biological specimens. Furthermore, the µ12 is integrated into the ImageJ ecosystem to leverage its built-in functionalities, like image acquisition, MTF evaluation and analysis tools.

  • Simulation of digital lensless holographic microscopy holograms: a physics-image processing approach

    by Maria J. Lopera, Carlos Buitrago-Duque, Jorge Garcia-Sucerquia, Yunfeng Nie, Heidi Ottevaere, Carlos Trujillo

    This work presents a method for simulating digital lensless holographic microscopy (DLHM) holograms using a physics-based image processing approach. While DLHM has gained significant attention in biology, biomedicine, and environmental monitoring, the current modeling of DLHM holograms has been limited, hindering potential applications, including learning-based solutions and generative model training. In this study, the DLHM propagation process is decomposed into the diffraction of a complex-valued spherical wavefront and the non-homogeneous magnification of the diffracted field that encodes the sample information, which accelerates and enhances the hologram simulation. The proposed model is validated by comparing simulated and experimental holograms of standard test targets under diverse imaging conditions. Comparative analyses are conducted against other DLHM hologram modeling methods, including direct Rayleigh-Sommerfeld diffraction, its convolutional implementation, and the Fresnel-Bluestein formalism. The proposed model is shown to outperform these methods in overall similarity to experimental recordings across a wide range of imaging conditions while maintaining computational efficiency. This DLHM hologram modeling approach provides researchers with a powerful tool for simulating trustable holograms. The model can be publicly accessed through the open-access repository https://github.com/mloper23/DLHM-model.


  • Cost-effective, DIY, and open-source digital lensless holographic microscope with distortion correction

    by Carlos Buitrago-Duque, Heberley Tobon-Maya, Samuel Zapata-Valencia, Jorge Garcia-Sucerquia

    Digital lensless holographic microscopy (DLHM) allows the design of cost-effective systems using off-the-shelf materials, making this type of lensless microscope accessible to many users worldwide. However, these materials may have a limited optomechanical performance that is aggravated due to the sought compactness and the intended cost-effective manufacturing process. This problem particularly affects the illumination source, which is of critical importance for DLHM, as it defines the optical performance of the microscope. While recent reports show that the required point source can be built from a low-cost laser diode coupled to an also low-cost aspheric lens, the resulting illumination has a distorted wavefront that limits the performance of the microscope. A simple homemade setup to correct the distortion of such illumination source and its integration into a compact, cost-effective, DIY, and open-source-certifiable digital lensless holographic microscope, is presented. The distortion-corrected DLHM is validated by imaging calibrated test targets and biological samples, achieving a 12-fold extension on the distortion-free magnification range of previous designs and a doubling of the effective spatial resolution without significant increments in its overall cost.

  • Multi-view occlusion removal in digital lensless holographic microscopy

    by Carlos Andrés Buitrago-Duque, Samuel Zapata-Valencia, Jorge Garcia-Sucerquia

    A multi-view occlusion removal method for digital lensless holographic microscopy (DLHM) is presented. Multiple DLHM holograms, whose individual reconstructions show occluded or partially occluded sample details, are recorded for different sample placements at its plane. A coordinated addition of the multiple DLHM recordings produces a composite hologram whose reconstruction allows the removal of the occlusions for a given imaging plane while increasing the reconstructed field of view. A theoretical model supports the method and its feasibility is tested with phase bio- and non-bio samples.

  • Point sources for digital lensless holographic microscopy: comparative assessment

    by Carlos Buitrago-Duque, Brayan Patiño-Jurado, Jorge Garcia-Sucerquia

    The light source in digital lensless holographic microscopy (DLHM) plays a key role in the optical performance of this microscopy methodology. The underlying physics that support DLHM rely on having an outward propagating spherical wavefront illuminating the sample to record on the surface of a digital camera the intensity of the diffracted wavefield that is magnified by free-space propagation; this first stage constitutes the recording. The information of the sample is numerically retrieved by computing the diffraction that an inward propagating spherical wavefront undergoes in the recorded intensity in a stage known as reconstruction. In both stages of this lensless microscopy method, it is assumed that perfect spherical wavefronts are utilized; hence, the closer the illumination light sources to exp[±ikr]/|r| are, the better the performance of the microscope. For the recovery of the information of the sample, the accuracy of the inward propagating spherical wavefront exp[−ikr]/|r| is guaranteed by its correct sampling in the numerical computation of the diffraction process; thus, the main challenge is the physical production of light sources to illuminate the sample whose amplitude profile is accurately described by exp[ikr]/|r|. In this work, the different approaches that our research group has explored to produce illuminating point sources for DLHM are evaluated. Point sources based on pinholes, coned-shaped optical fibers, optical pick-up units, and aspheric lenses are evaluated by rating their robustness, compactness, reliability, cost and easiness of production, and their performance on imaging test targets and biosamples. Some additional DLHM light sources reported in the literature are also briefly reviewed based on their available data.


  • Cost-Effective, DIY, and Open-Source Digital Lensless Holographic Microscope with Distortion Correction

    by C. Buitrago-Duque, H. Tobón-Maya, J. Garcia-Sucerquia

    A cost-effective, DIY, and open-source certifiable digital lensless holographic microscope (DLHM) is presented. The proposed microscope reduces the flaws regularly found when budget laser diodes and aspherical lenses are utilized in compact setups.

  • Experimental Method to Remove Occlusions in Digital Lensless Holographic Microscopy

    by C. Buitrago-Duque, S. Zapata-Valencia, J. Garcia-Sucerquia

    An experimental method to remove occlusions in digital lensless holographic microscopy is presented. The coordinated addition of a set of in-line holograms produces a composite hologram, whose reconstruction retrieves the sample information without any occlusions.