Emilio Sánchez-Ortiga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Emilio Sánchez-Ortiga has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Martinez-Corral
D Imaging and Display Laboratory, Department of Optics, Universitat de Valncia, Burjassot, Spain
45 shared publications - Genaro Saavedra
Universitat de València
30 shared publications - Ana Doblas
University of Massachusetts Dartmouth
17 shared publications - Jorge Garcia-Sucerquia
School of Physics
15 shared publications Genaro Saavedra
11 shared publicationsAnabel Llavador
Univ. de Valencia (Spain)
6 shared publications
Latest Publications
- Open Access
- 4 June 2026
- Published by IOP Publishing in European Journal of Physics
- Vol. 47 (3)
Aperiodic order and Fraunhofer diffraction in one-dimensional Silver Mean gratings
We study the Fraunhofer diffraction produced by one-dimensional binary gratings based on the Silver Mean sequence, a deterministic aperiodic ordering closely related to the Pell numbers and the silver ratio. Analytical expressions for the diffraction patterns are derived within the scalar approximation, revealing a characteristic redistribution of diffracted energy and the splitting of the first diffraction orders into multiple well-defined maxima. We show that the transverse positions of these maxima are governed by simple combinations of Pell numbers, reflecting the scaling properties of the underlying aperiodic structure. The theoretical predictions are experimentally verified using a simple optical setup based on a spatial light modulator, which can be readily implemented in undergraduate teaching laboratories. These gratings provide an accessible and pedagogically valuable extension of diffraction experiments based on periodic, fractal and Fibonacci-type structures, allowing students to explore the optical consequences of deterministic aperiodic order through direct observation of their diffraction patterns.
- 4 June 2026
- Published by IOP Publishing in European Journal of Physics
- Vol. 47 (3)
Open AccessAperiodic order and Fraunhofer diffraction in one-dimensional Silver Mean gratings
We study the Fraunhofer diffraction produced by one-dimensional binary gratings based on the Silver Mean sequence, a deterministic aperiodic ordering closely related to the Pell numbers and the silver ratio. Analytical expressions for the diffraction patterns are derived within the scalar approximation, revealing a characteristic redistribution of diffracted energy and the splitting of the first diffraction orders into multiple well-defined maxima. We show that the transverse positions of these maxima are governed by simple combinations of Pell numbers, reflecting the scaling properties of the underlying aperiodic structure. The theoretical predictions are experimentally verified using a simple optical setup based on a spatial light modulator, which can be readily implemented in undergraduate teaching laboratories. These gratings provide an accessible and pedagogically valuable extension of diffraction experiments based on periodic, fractal and Fibonacci-type structures, allowing students to explore the optical consequences of deterministic aperiodic order through direct observation of their diffraction patterns.
- Open Access
- 29 May 2026
- Published by IOP Publishing in Journal of Physics: Photonics
Pell–Lucas diffractive lenses for trifocal multi-trap optical tweezers
In this work, we introduce a new family of trifocal diffractive lenses based on the Pell–Lucas number sequence. Two phase configurations are considered: binary-phase and kinoform-type. Numerical simulations of the irradiance distributions show that both designs generate three well-defined focal points along the optical axis with identical spatial positions. The kinoform-type lens, however, demonstrates significantly higher energy efficiency by concentrating nearly all the diffracted energy into the first diffraction order of the Pell-Lucas lens. This represents the first reports of trifocal diffractive lenses based on an aperiodic mathematical sequence. The intensity profile is characterized by a dominant central focus accompanied by two additional lower-intensity focal positions, whose axial arrangement follows the characteristic behavior imposed by the Pell–Lucas sequence and exhibits a direct relationship with the silver ratio. Experimental validation of the kinoform Pell–Lucas zone plate shows good agreement with numerical predictions. Furthermore, the proposed lenses are implemented in a multi-trap optical tweezers configuration, enabling simultaneous particles manipulation at three distinct axial planes.
- 29 May 2026
- Published by IOP Publishing in Journal of Physics: Photonics
Open AccessPell–Lucas diffractive lenses for trifocal multi-trap optical tweezers
In this work, we introduce a new family of trifocal diffractive lenses based on the Pell–Lucas number sequence. Two phase configurations are considered: binary-phase and kinoform-type. Numerical simulations of the irradiance distributions show that both designs generate three well-defined focal points along the optical axis with identical spatial positions. The kinoform-type lens, however, demonstrates significantly higher energy efficiency by concentrating nearly all the diffracted energy into the first diffraction order of the Pell-Lucas lens. This represents the first reports of trifocal diffractive lenses based on an aperiodic mathematical sequence. The intensity profile is characterized by a dominant central focus accompanied by two additional lower-intensity focal positions, whose axial arrangement follows the characteristic behavior imposed by the Pell–Lucas sequence and exhibits a direct relationship with the silver ratio. Experimental validation of the kinoform Pell–Lucas zone plate shows good agreement with numerical predictions. Furthermore, the proposed lenses are implemented in a multi-trap optical tweezers configuration, enabling simultaneous particles manipulation at three distinct axial planes.
- 22 May 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (16) , 4228-4235
Practical guide for setting up a Fourier light-field microscope
A practical guide for the easy implementation of a Fourier light-field microscope is reported. The Fourier light-field concept applied to microscopy allows the capture in real time of a series of 2D orthographic images of microscopic thick dynamic samples. Such perspective images contain spatial and angular information of the light-field emitted by the sample. A feature of this technology is the tight requirement of a double optical conjugation relationship, and also the requirement of NA matching. For these reasons, the Fourier light-field microscope being a non-complex optical system, a clear protocol on how to set up the optical elements accurately is needed. In this sense, this guide is aimed to simplify the implementation process, with an optical bench and off-the-shelf components. This will help the widespread use of this recent technology.
- 22 May 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (16) , 4228-4235
Practical guide for setting up a Fourier light-field microscope
A practical guide for the easy implementation of a Fourier light-field microscope is reported. The Fourier light-field concept applied to microscopy allows the capture in real time of a series of 2D orthographic images of microscopic thick dynamic samples. Such perspective images contain spatial and angular information of the light-field emitted by the sample. A feature of this technology is the tight requirement of a double optical conjugation relationship, and also the requirement of NA matching. For these reasons, the Fourier light-field microscope being a non-complex optical system, a clear protocol on how to set up the optical elements accurately is needed. In this sense, this guide is aimed to simplify the implementation process, with an optical bench and off-the-shelf components. This will help the widespread use of this recent technology.
- 6 January 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (2) , 2000-2012
Resolution limit in opto-digital systems revisited
The resolution limit achievable with an optical system is a fundamental piece of information when characterizing its performance, mainly in case of microscopy imaging. Usually this information is given in the form of a distance, often expressed in microns, or in the form of a cutoff spatial frequency, often expressed in line pairs per mm. In modern imaging systems, where the final image is collected by pixelated digital cameras, the resolution limit is determined by the performance of both, the optical systems and the digital sensor. Usually, one of these factors is considered to be prevalent over the other for estimating the spatial resolution, leading to the global performance of the imaging system ruled by either the classical Abbe resolution limit, based on physical diffraction, or by the Nyquist resolution limit, based on the digital sensor features. This estimation fails significantly to predict the global performance of opto-digital imaging systems, like 3D microscopes, where none of the factors is negligible. In that case, which indeed is the most common, neither the Abbe formula nor the Nyquist formula provide by themselves a reliable prediction for the resolution limit. This is a serious drawback since systems designers often use those formulae as design input parameters. Aiming to overcome this lack, a simple mathematical expression obtained by finely articulating the Abbe and Nyquist formulas, to easily predict the spatial resolution limit of opto-digital imaging systems, is proposed here. The derived expression is tested experimentally, and shows to be valid in a broad range of opto-digital combinations.
- 6 January 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (2) , 2000-2012
Resolution limit in opto-digital systems revisited
The resolution limit achievable with an optical system is a fundamental piece of information when characterizing its performance, mainly in case of microscopy imaging. Usually this information is given in the form of a distance, often expressed in microns, or in the form of a cutoff spatial frequency, often expressed in line pairs per mm. In modern imaging systems, where the final image is collected by pixelated digital cameras, the resolution limit is determined by the performance of both, the optical systems and the digital sensor. Usually, one of these factors is considered to be prevalent over the other for estimating the spatial resolution, leading to the global performance of the imaging system ruled by either the classical Abbe resolution limit, based on physical diffraction, or by the Nyquist resolution limit, based on the digital sensor features. This estimation fails significantly to predict the global performance of opto-digital imaging systems, like 3D microscopes, where none of the factors is negligible. In that case, which indeed is the most common, neither the Abbe formula nor the Nyquist formula provide by themselves a reliable prediction for the resolution limit. This is a serious drawback since systems designers often use those formulae as design input parameters. Aiming to overcome this lack, a simple mathematical expression obtained by finely articulating the Abbe and Nyquist formulas, to easily predict the spatial resolution limit of opto-digital imaging systems, is proposed here. The derived expression is tested experimentally, and shows to be valid in a broad range of opto-digital combinations.
- Open Access
- 29 October 2022
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 161
Fast and robust wave optics-based reconstruction protocol for Fourier lightfield microscopy
- 29 October 2022
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 161
Open AccessFast and robust wave optics-based reconstruction protocol for Fourier lightfield microscopy
- Open Access
Machine Learning-Based View Synthesis in Fourier Lightfield Microscopy
Current interest in Fourier lightfield microscopy is increasing, due to its ability to acquire 3D images of thick dynamic samples. This technique is based on simultaneously capturing, in a single shot, and with a monocular setup, a number of orthographic perspective views of 3D microscopic samples. An essential feature of Fourier lightfield microscopy is that the number of acquired views is low, due to the trade-off relationship existing between the number of views and their corresponding lateral resolution. Therefore, it is important to have a tool for the generation of a high number of synthesized view images, without compromising their lateral resolution. In this context we investigate here the use of a neural radiance field view synthesis method, originally developed for its use with macroscopic scenes acquired with a moving (or an array of static) digital camera(s), for its application to the images acquired with a Fourier lightfield microscope. The results obtained and presented in this paper are analyzed in terms of lateral resolution and of continuous and realistic parallax. We show that, in terms of these requirements, the proposed technique works efficiently in the case of the epi-illumination microscopy mode.
Open AccessMachine Learning-Based View Synthesis in Fourier Lightfield Microscopy
Current interest in Fourier lightfield microscopy is increasing, due to its ability to acquire 3D images of thick dynamic samples. This technique is based on simultaneously capturing, in a single shot, and with a monocular setup, a number of orthographic perspective views of 3D microscopic samples. An essential feature of Fourier lightfield microscopy is that the number of acquired views is low, due to the trade-off relationship existing between the number of views and their corresponding lateral resolution. Therefore, it is important to have a tool for the generation of a high number of synthesized view images, without compromising their lateral resolution. In this context we investigate here the use of a neural radiance field view synthesis method, originally developed for its use with macroscopic scenes acquired with a moving (or an array of static) digital camera(s), for its application to the images acquired with a Fourier lightfield microscope. The results obtained and presented in this paper are analyzed in terms of lateral resolution and of continuous and realistic parallax. We show that, in terms of these requirements, the proposed technique works efficiently in the case of the epi-illumination microscopy mode.
- 21 March 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (10) , 2558-2564
Fourier lightfield microscopy: a practical design guide
In this work, a practical guide for the design of a Fourier lightfield microscope is reported. The fundamentals of the Fourier lightfield are presented and condensed on a set of contour plots from which the user can select the design values of the spatial resolution, the field of view, and the depth of field, as function of the specifications of the hardware of the host microscope. This work guides the reader to select the parameters of the infinity-corrected microscope objective, the optical relay lenses, the aperture stop, the microlens array, and the digital camera. A user-friendly graphic calculator is included to ease the design, even to those who are not familiar with the lightfield technology. The guide is aimed to simplify the design process of a Fourier lightfield microscope, which sometimes could be a daunting task, and in this way, to invite the widespread use of this technology. An example of a design and experimental results on imaging different types of samples is also presented.
- 21 March 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (10) , 2558-2564
Fourier lightfield microscopy: a practical design guide
In this work, a practical guide for the design of a Fourier lightfield microscope is reported. The fundamentals of the Fourier lightfield are presented and condensed on a set of contour plots from which the user can select the design values of the spatial resolution, the field of view, and the depth of field, as function of the specifications of the hardware of the host microscope. This work guides the reader to select the parameters of the infinity-corrected microscope objective, the optical relay lenses, the aperture stop, the microlens array, and the digital camera. A user-friendly graphic calculator is included to ease the design, even to those who are not familiar with the lightfield technology. The guide is aimed to simplify the design process of a Fourier lightfield microscope, which sometimes could be a daunting task, and in this way, to invite the widespread use of this technology. An example of a design and experimental results on imaging different types of samples is also presented.
- Open Access
Handheld and Cost-Effective Fourier Lightfield Microscope
In this work, the design, building, and testing of the most portable, easy-to-build, robust, handheld, and cost-effective Fourier Lightfield Microscope (FLMic) to date is reported. The FLMic is built by means of a surveillance camera lens and additional off-the-shelf optical elements, resulting in a cost-effective FLMic exhibiting all the regular sought features in lightfield microscopy, such as refocusing and gathering 3D information of samples by means of a single-shot approach. The proposed FLMic features reduced dimensions and light weight, which, combined with its low cost, turn the presented FLMic into a strong candidate for in-field application where 3D imaging capabilities are pursued. The use of cost-effective optical elements has a relatively low impact on the optical performance, regarding the figures dictated by the theory, while its price can be at least 100 times lower than that of a regular FLMic. The system operability is tested in both bright-field and fluorescent modes by imaging a resolution target, a honeybee wing, and a knot of dyed cotton fibers.
Open AccessHandheld and Cost-Effective Fourier Lightfield Microscope
In this work, the design, building, and testing of the most portable, easy-to-build, robust, handheld, and cost-effective Fourier Lightfield Microscope (FLMic) to date is reported. The FLMic is built by means of a surveillance camera lens and additional off-the-shelf optical elements, resulting in a cost-effective FLMic exhibiting all the regular sought features in lightfield microscopy, such as refocusing and gathering 3D information of samples by means of a single-shot approach. The proposed FLMic features reduced dimensions and light weight, which, combined with its low cost, turn the presented FLMic into a strong candidate for in-field application where 3D imaging capabilities are pursued. The use of cost-effective optical elements has a relatively low impact on the optical performance, regarding the figures dictated by the theory, while its price can be at least 100 times lower than that of a regular FLMic. The system operability is tested in both bright-field and fluorescent modes by imaging a resolution target, a honeybee wing, and a knot of dyed cotton fibers.
- 22 December 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (1) , 511-521
Three-dimensional imaging through patterned type-1 microscopy
We report a scanning non-confocal fluorescence microscopy scheme that provides images with optical sectioning and with a lateral resolution that surpasses by a factor of two the diffraction resolution limit. This technique is based on the type-1 microscopy concept combined with patterned illumination. The method does not require the application of phase-shifting or post-processing algorithms and provides artifact-free superresolved 3D images. We have validated the theory by means of experimental data.
- 22 December 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (1) , 511-521
Three-dimensional imaging through patterned type-1 microscopy
We report a scanning non-confocal fluorescence microscopy scheme that provides images with optical sectioning and with a lateral resolution that surpasses by a factor of two the diffraction resolution limit. This technique is based on the type-1 microscopy concept combined with patterned illumination. The method does not require the application of phase-shifting or post-processing algorithms and provides artifact-free superresolved 3D images. We have validated the theory by means of experimental data.