BKByeonggwan Kim

Byeonggwan Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Byeonggwan Kim has a total of 117 co-authors. Here are the top co-authors by number of shared publications:

  • Eunkyoung Kim

    Department of Chemical and Biomolecular Engineering Yonsei University 50 Yonsei‐ro, Seodaemun‐gu Seoul 03722 South Korea

    29 shared publications
  • Jeonghun Kim

    Department of Chemical and Biomolecular Engineering, Active Polymer Center for Pattern Integration, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 120-749 (South Korea)

    12 shared publications
  • Teahoon Park

    Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul, South Korea

    10 shared publications
  • Eunkyoung Kim

    Department of Chemical and Biomolecular Engineering Yonsei University Seoul 03722 South Korea

    9 shared publications
  • Jungmok You

    Department of Chemical and Biomolecular Engineering, Active Polymer Center for Pattern Integration, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 120-749 (South Korea)

    6 shared publications
  • Haijin Shin

    5 shared publications

Latest Publications

  • Open Access

    Integration and Implementation of Machine Learning & Artificial Intelligence in Surface‐Enhanced Raman Spectroscopy

    by Netrapal Singh, Ba Thong Trinh, Sy Khiem Nguyen, Khanh Viet Nguyen, Changwook Kim, Byeonggwan Kim, Youngku Sohn, Ilsun Yoon

    Surface‐enhanced Raman spectroscopy (SERS) is an analytical technique widely used for molecular identification and trace detection, offering minimal sample preparation, high sensitivity, molecular fingerprinting, and quantitative capability. However, SERS measurements generate large, complex spectral datasets whose interpretation is time‐consuming and requires specialized expertise. The integration of artificial intelligence (AI) and machine learning (ML) provides effective strategies for automated data processing, feature extraction, and pattern recognition, enabling a new generation of intelligent SERS sensing platforms. Unlike previous reviews, which have largely catalogued AI/ML‐SERS applications by domain, this work provides a critical synthesis structured around four contributions: (i) a workflow‐level taxonomy linking SERS data characteristics to algorithm selection; (ii) a quantitative meta‐analysis of approximately 40 representative studies covering the distribution of reported accuracies, the relationship between dataset size and reported performance, and the temporal shift from classical chemometrics to deep learning; (iii) a dedicated assessment of validation pitfalls specific to AI/ML‐SERS, including substrate batch effects, technical‐replicate leakage, spectrum‐level versus sample‐level splitting, and the absence of external validation cohorts; and (iv) a practical reporting checklist for future AI/ML‐SERS studies. By foregrounding methodological rigor rather than enumeration, the review aims to support both SERS practitioners adopting AI/ML and ML researchers entering spectroscopic sensing.


  • Open Access

    Highly Conductive and Stretchable Photothermal CuSe Fiber for Wearable Electronics and Implantable Drug Release Systems

    by Kukro Yoon, Yukye Lee, Sang Ki Rhee, Hyeonjoo Park, Kyowon Kang, Mingyu Sang, Byeonggwan Kim, Jung Seung Lee, Jaehong Lee, Taeyoon Lee

    Recently, fiber electronics have emerged as promising platforms for next‐generation wearable and biomedical systems because of their flexibility, light weight, and softness. Among them, photothermal fibers are particularly attractive for therapeutic applications because of their remote and localized heat generation. However, most existing photothermal fibers rely on near‐infrared (NIR)‐I‐responsive materials, which exhibit shallow tissue penetration and limited efficiency, thereby restricting their applicability in tissue implantation. In this study, a stretchable photothermal copper (II) selenide (CuSe) fiber was fabricated via a simple solution‐based synthesis. Owing to the uniformly embedded CuSe nanoplates within the polyurethane matrix, the fabricated CuSe fiber exhibits high electrical conductivity (3.419 S/cm), excellent stretchability (100% tensile strain), and stable heating up to 81.7°C under NIR‐II irradiation. When integrated into textiles, the fiber can function as both a reliable strain sensor (gauge factor = 28.88) and a wearable heater (photothermal conversion efficiency = 40.1%). In addition, an implantable NIR‐triggered drug release fiber was developed by coating the prepared CuSe fiber with a thermo‐responsive hydrogel, achieving photothermal‐triggered drug release and exhibiting therapeutic efficacy in mice with lipopolysaccharide‐induced sepsis. Overall, the developed NIR‐II‐responsive CuSe photothermal fiber provides a versatile and clinically relevant platform for next‐generation wearable and biomedical systems.


  • High thermoelectric conversion through an optimal contribution of electronic carriers in polymeric mixed ionic–electronic conducting films

    by Cheolhyun Cho, Byeonggwan Kim, Sienoh Park, Eunkyoung Kim

    The optimal contribution of electronic carriers in polymeric mixed ionic–electronic conducting (MIEC) films was explored to achieve high thermoelectric (TE) conversion at a low temperature gradient (ΔT) using poly(2-acrylamido-2-methyl-1-propanesulfonic acid) (P), potassium ferricyanide (F), and well-dispersed graphene flakes (G). In this composite (PFG) film, the active carriers were identified as CN− and electrons. The sulfonate groups in P effectively dispersed the graphene flakes into nanoscale electronic channels, while P and F provided ionic channels for CN− transport. By systematically varying the G content and humidity, a series of MIECs with broad electronic (σe) and ionic (σi) conductivity ranges were developed. Among these, the PFG film containing 3 wt% G (PFG3) exhibited a remarkable total Seebeck coefficient (S) of over −40 mV K−1 under conditions of a ΔT of 5.3 K, 80% RH and room temperature. Additionally, PFG3 demonstrated a stable voltage output (Vout) even after 3000 s. From the residual Vout, the electronic Seebeck coefficient (Se) was determined to be −990 μV K−1, the highest value reported for polymeric TE films. The simultaneous enhancement of Se and S in the same film indicated an optimized balance of electronic and ionic carrier contributions, further confirmed by the transference numbers and the conductivity ratio (σe/σi). The power density (PD) of the PFGs was also found to depend on σe/σi, underscoring the importance of controlling carrier contributions. Despite its MIEC nature, PFG3 efficiently transported electronic carriers through G channels, and the relationship of Sevs. σe aligned with a degenerate electronic model for PFGs. Scaling up the PFG3 film into a TE module yielded an energy density of 36.0 J m−2 and a PD of 18.6 mW m−2 for a ΔT of 4.9 K. The practical potential of the PFG system was demonstrated by successfully powering a diode for an extended period using TE energy harvesting and light-triggered photo-TE systems, highlighting the versatility and promise of this material for low-grade thermal energy applications.


  • Open Access

    Highly Stretchable Thermoelectric Fiber with Embedded Copper(I) Iodide Nanoparticles for a Multimodal Temperature, Strain, and Pressure Sensor in Wearable Electronics

    by Kukro Yoon, Sanghyeon Lee, Chaebeen Kwon, Chihyeong Won, Sungjoon Cho, Seungmin Lee, Minkyu Lee, Jinhan Lee, Hyeokjun Lee, Kyung‐In Jang, et al.

    Thermoelectric (TE) fibers have excellent potential for multimodal sensor, which can detect mechanical and thermal stimuli, used in advanced wearable electronics for personalized healthcare system. However, previously reported TE fibers have limitations for use in wearable multimodal sensors due to the following reasons: 1) TE fibers composed of carbon or organic materials have low TE performance to detect thermal variations effectively; 2) TE fibers composed of rigid inorganic materials are not stretchable, limiting their ability to detect mechanical deformation. Herein, the first stretchable TE fiber‐based multimodal sensor is developed using copper(I) iodide (CuI), an inorganic TE material, through a novel fabrication method. The dense CuI nanoparticle networks embedded in the fiber allow the sensor to achieve excellent stretchability (maximum tensile strain of ≈835%) and superior TE performance (Seebeck coefficient of ≈203.6 µV K−1) simultaneously. The sensor exhibits remarkable performances in strain sensing (gauge factor of ≈3.89 with tensile strain range of ≈200%) and pressure sensing (pressure resolution of ≈250 Pa with pressure range of ≈84 kPa). Additionally, the sensor enables independent and simultaneous temperature change, tensile strain, and pressure sensing by measuring distinct parameters. It is seamlessly integrated into a smart glove, demonstrating its practical application in wearable technology.


  • Open Access

    Bioresorbable polymers for electronic medicine

    by Jung Hwangbo, Hyungho Seo, Gyuhyeon Sim, Raudel Avila, Malavika Nair, Byeonggwan Kim, Yeonsik Choi


  • Mesogenic polymer composites for temperature-programmable thermoelectric ionogels

    by Sienoh Park, Byeonggwan Kim, Cheolhyun Cho, Eunkyoung Kim

    Thermally programmable ionic thermoelectric (iTE) composites with optical tunability are explored as a transmittance tunable energy harvester to operate as a thermal sensor for low-grade heat sources. Liquid crystalline ionogels (LCIs) for iTE films are prepared via photopolymerization of ionic monomers (2-acrylamido-2-methyl-1-propanesulfonic acid) and hydrophobic nematic monomers (4-methoxyphenyl 4-((6-(acryloyloxy)hexyl)oxy)benzoate) in the presence of an ionic liquid. The LCI film shows reversible temperature programmability as well as fast transmittance switching at 65 °C, at which temperature the nematic-isotropic phase transition occurs. The LCI film for the iTE device shows a phase-controlled ionic Seebeck coefficient of −5.9 mV K−1 at 80% RH and produces a maximum thermoelectric power factor of 2.4 nW m−1 K−2. Taking advantage of the reversible thermoresponsiveness, the LCI iTE film is used to demonstrate a self-detectable and wireless fire alarm, which enables detection of elevated temperatures with the naked eye. Furthermore, the LCI iTE film is integrated as a thermal switch for an electrochromic window, a liquid crystal display, or a light-emitting diode to realize autonomous self-powered electronics that can be used to detect and view temperature changes in the environment.


  • Bisulfate transport in hydrogels for self-healable and transparent thermoelectric harvesting films

    by Cheolhyun Cho, Byeonggwan Kim, Sienoh Park, Eunkyoung Kim

    A wearable and transparent thermoelectric hydrogel based on bisulfate transport was demonstrated to record a negative ionic Seebeck coefficient of −25.0 mV K−1and an ionic figure of merit of 7.2 at 80% relative humidity and room temperature.


  • Giant Photo‐Magneto‐Thermoelectric Effect of End‐On Oriented PEDOT Grown from Self‐Assembled 3D Tectons

    by Byeonggwan Kim, Cheolhyun Cho, Minsu Han, André‐Jean Attias, Eunkyoung Kim

    Conductive polymers (CPs) are arranged in the end‐on direction on graphene surfaces using 3D tectons of ZnPc assemblies, to control carrier transport from hot to cold via external magnetic fields. Poly(3,4‐ethylenedioxythiophene)s doped with tosylate are synthesized using monomer seeds that are complexed through pyridine units to 3D tectons on graphene via surface‐confined host‐guest chemistry, to provide an end‐on‐oriented polymer film on graphene with a high degree of crystallinity. The film shows free‐electron‐like charge transport properties, with an enhanced Hall mobility, and an increased Seebeck coefficient compared to the CP on graphene that is prepared without 3D tectons. A magneto‐thermoelectric (MTE) effect is reproducibly observed for the film device. Taking advantage of a large photothermal effect of the polymer film, a photon‐mode MTE effect is demonstrated for the first time. Both dark and photo‐MTE effects correlate well to the generated Lorentz force. These results provide a unique tool to program carrier transport in thin‐film via external magnetic stimuli with a temperature gradient.


  • Open Access

    Conjugated Organic Photothermal Films for Spatiotemporal Thermal Engineering

    by Hee Jung Kim, Byeonggwan Kim, Yanghyun Auh, Eunkyoung Kim

    With the growth of photoenergy harvesting and thermal engineering, photothermal materials (PTMs) have attracted substantial interest due to their unique functions such as localized heat generation, spatiotemporal thermal controllability, invisibility, and light harvesting capabilities. In particular, π‐conjugated organic PTMs show advantages over inorganic or metallic PTMs in thin film applications due to their large light absorptivity, ease of synthesis and tunability of molecular structures for realizing high NIR absorption, flexibility, and solution processability. This review is intended to provide an overview of organic PTMs, including both molecular and polymeric PTMs. A description of the photothermal (PT) effect and conversion efficiency (ηPT) for organic films is provided. After that, the chemical structure and optical properties of organic PTMs are discussed. Finally, emerging applications of organic PT films from the perspective of spatiotemporal thermal engineering principles are illustrated.


  • 2D host–guest supramolecular chemistry for an on-monolayer graphene emitting platform

    by Byeonggwan Kim, Cheolhyun Cho, Imad Arfaoui, Céline Paris, Christophe Petit, Tangui Le Bahers, Eunkyoung Kim, André-Jean Attias

    Electronic decoupling of molecular emitters from monolayer graphene allows luminescence of the hybrid platform, opening new perspectives for 2D materials-based nanophotonics.