Sarah E. Schmitt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sarah E. Schmitt has a total of 172 co-authors. Here are the top co-authors by number of shared publications:
- Lawrence J. Hirsch
Department of Neurology Yale School of Medicine New Haven Connecticut USA
7 shared publications Elizabeth E. Gerard
The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, U.S.A.
4 shared publicationsNicholas S. Abend
The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, U.S.A.
4 shared publications- Zubeda Sheikh
Department of Neurology Yale University School of Medicine New Haven Connecticut USA
4 shared publications - Cecil D. Hahn
Division of Neurology, Hospital for Sick Children and Department of Paediatrics University of Toronto Toronto Ontario Canada
3 shared publications - Hiba Arif Haider
Department of Neurology University of Chicago Chicago Illinois USA
3 shared publications
Latest Publications
- Open Access
Accuracy of the rapid‐response electroencephalography's Automated Seizure Burden Estimator: A follow‐up validation study of version 8 ( AccuRASE II )
Objective: Ceribell Inc.'s point‐of‐care electroencephalographic (EEG) system and artificial intelligence‐based Automated Seizure Burden Estimator (ASBE; ClarityPro) have US Food and Drug Administration clearance for diagnosing electrographic status epilepticus (ESE). The AccuRASE study using ASBE version 6 (V6) showed high negative predictive value (NPV) but limited sensitivity and positive predictive value (PPV) at certain thresholds. Version 8 (V8) is the updated algorithm trained with additional EEG samples. Methods: We tested V8 on the previously used rapid‐response EEG test dataset (not used to train V8). Sensitivity, specificity, PPV, and NPV were compared against blinded expert annotations. ESE, ESE and possible ESE (ESE/pESE), electrographic seizures (ESz), and Esz with highly epileptiform patterns (Esz/HEPs) at burden thresholds of >1%, >10%, >20%, >50%, and >90% were analyzed. Additionally, we evaluated the built‐in ESE and ESE/pESE alerts (≥90% over 5 min, ≥20% over 1 h, or ≥10 continuous minutes of seizure). Results: V8 showed 100% sensitivity at lower thresholds (>10%–20%) for ESE (V6 .86), without a specificity loss (V8 .9 vs. V6 .85), and retained NPV (V8 1.0 vs. V6 .99). Sensitivity at 50% threshold was .86 for ESE (V6 .71), and specificity was .94 (V6 .91); PPV for ESE was 30% for ESE and 80% for ESE/pESE. The specificity for ESE remained high for 90% burden (V8 .96, V6 .97) but the sensitivity dropped (.29 vs. V6 .43). Sensitivity was lower for ESz/HEPs (.54 → .44 at >10% threshold), although the algorithm is not designed to detect HEPs. Built‐in alert analysis showed significantly improved sensitivity for ESE (.57 → .86); specificity and NPV remained high (>.94). Significance: ASBE V8 showed meaningful improvements in sensitivity, continued excellent NPV, and improved built‐in alert accuracy for ESE and ESE/pESE. The best seizure burden threshold for ruling out ESE now is 20% (vs. 10% with V6) and that for ruling in ESE/pESE with reasonable certainty is 50% (vs. 90% with V6).
Open AccessAccuracy of the rapid‐response electroencephalography's Automated Seizure Burden Estimator: A follow‐up validation study of version 8 ( AccuRASE II )
Objective: Ceribell Inc.'s point‐of‐care electroencephalographic (EEG) system and artificial intelligence‐based Automated Seizure Burden Estimator (ASBE; ClarityPro) have US Food and Drug Administration clearance for diagnosing electrographic status epilepticus (ESE). The AccuRASE study using ASBE version 6 (V6) showed high negative predictive value (NPV) but limited sensitivity and positive predictive value (PPV) at certain thresholds. Version 8 (V8) is the updated algorithm trained with additional EEG samples. Methods: We tested V8 on the previously used rapid‐response EEG test dataset (not used to train V8). Sensitivity, specificity, PPV, and NPV were compared against blinded expert annotations. ESE, ESE and possible ESE (ESE/pESE), electrographic seizures (ESz), and Esz with highly epileptiform patterns (Esz/HEPs) at burden thresholds of >1%, >10%, >20%, >50%, and >90% were analyzed. Additionally, we evaluated the built‐in ESE and ESE/pESE alerts (≥90% over 5 min, ≥20% over 1 h, or ≥10 continuous minutes of seizure). Results: V8 showed 100% sensitivity at lower thresholds (>10%–20%) for ESE (V6 .86), without a specificity loss (V8 .9 vs. V6 .85), and retained NPV (V8 1.0 vs. V6 .99). Sensitivity at 50% threshold was .86 for ESE (V6 .71), and specificity was .94 (V6 .91); PPV for ESE was 30% for ESE and 80% for ESE/pESE. The specificity for ESE remained high for 90% burden (V8 .96, V6 .97) but the sensitivity dropped (.29 vs. V6 .43). Sensitivity was lower for ESz/HEPs (.54 → .44 at >10% threshold), although the algorithm is not designed to detect HEPs. Built‐in alert analysis showed significantly improved sensitivity for ESE (.57 → .86); specificity and NPV remained high (>.94). Significance: ASBE V8 showed meaningful improvements in sensitivity, continued excellent NPV, and improved built‐in alert accuracy for ESE and ESE/pESE. The best seizure burden threshold for ruling out ESE now is 20% (vs. 10% with V6) and that for ruling in ESE/pESE with reasonable certainty is 50% (vs. 90% with V6).
- 26 June 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (7)
Expert-Level Detection of Epilepsy Markers in EEG on Short and Long Timescales
Epileptiform discharges, or spikes, within electroencephalogram (EEG) recordings are essential for diagnosing epilepsy and localizing seizure origins. Artificial intelligence (AI) offers a promising approach to automating detection, but current models are often hindered by artifact-related false positives and often target either event- or EEG-level classification, thus limiting clinical utility. We developed SpikeNet2, a deep-learning model based on a residual network architecture, and enhanced it with hard-negative mining to reduce false positives. Our study analyzed 17,812 EEG recordings from 13,523 patients across multiple institutions, including Massachusetts General Brigham (MGB) hospitals. Data from the Human Epilepsy Project (HEP) and SCORE-AI (SAI) were also included. A total of 32,433 event-level samples, labeled by experts, were used for training and evaluation. Performance was assessed using the area under the receiver operating characteristic curve (AUROC), the area under the precision–recall curve (AUPRC), calibration error, and a modified area under the curve (mAUC) metric. The model’s generalizability was evaluated using external datasets. SpikeNet2 demonstrated strong performance in event-level spike detection, achieving an AUROC of 0.973 and an AUPRC of 0.995, with 44% of experts surpassing the model on the MGB dataset. In external validation, the model achieved an AUROC of 0.942 and an AUPRC of 0.948 on the HEP dataset. For EEG-level classification, SpikeNet2 recorded an AUROC of 0.958 and an AUPRC of 0.959 on the MGB dataset, an AUROC of 0.888 and an AUPRC of 0.823 on the HEP dataset, and an AUROC of 0.995 and an AUPRC of 0.991 on the SAI dataset, with 32% of experts outperforming the model. The false-positive rate was reduced to an average of nine spikes per hour. SpikeNet2 offers expert-level accuracy in both event-level spike detection and EEG-level classification, while significantly reducing false positives. Its dual functionality and robust performance across diverse datasets make it a promising tool for clinical and telemedicine applications, particularly in resource-limited settings. (Funded by the National Institutes of Health and others.)
- 26 June 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (7)
Expert-Level Detection of Epilepsy Markers in EEG on Short and Long Timescales
Epileptiform discharges, or spikes, within electroencephalogram (EEG) recordings are essential for diagnosing epilepsy and localizing seizure origins. Artificial intelligence (AI) offers a promising approach to automating detection, but current models are often hindered by artifact-related false positives and often target either event- or EEG-level classification, thus limiting clinical utility. We developed SpikeNet2, a deep-learning model based on a residual network architecture, and enhanced it with hard-negative mining to reduce false positives. Our study analyzed 17,812 EEG recordings from 13,523 patients across multiple institutions, including Massachusetts General Brigham (MGB) hospitals. Data from the Human Epilepsy Project (HEP) and SCORE-AI (SAI) were also included. A total of 32,433 event-level samples, labeled by experts, were used for training and evaluation. Performance was assessed using the area under the receiver operating characteristic curve (AUROC), the area under the precision–recall curve (AUPRC), calibration error, and a modified area under the curve (mAUC) metric. The model’s generalizability was evaluated using external datasets. SpikeNet2 demonstrated strong performance in event-level spike detection, achieving an AUROC of 0.973 and an AUPRC of 0.995, with 44% of experts surpassing the model on the MGB dataset. In external validation, the model achieved an AUROC of 0.942 and an AUPRC of 0.948 on the HEP dataset. For EEG-level classification, SpikeNet2 recorded an AUROC of 0.958 and an AUPRC of 0.959 on the MGB dataset, an AUROC of 0.888 and an AUPRC of 0.823 on the HEP dataset, and an AUROC of 0.995 and an AUPRC of 0.991 on the SAI dataset, with 32% of experts outperforming the model. The false-positive rate was reduced to an average of nine spikes per hour. SpikeNet2 offers expert-level accuracy in both event-level spike detection and EEG-level classification, while significantly reducing false positives. Its dual functionality and robust performance across diverse datasets make it a promising tool for clinical and telemedicine applications, particularly in resource-limited settings. (Funded by the National Institutes of Health and others.)
- 28 January 2025
- Published by Wolters Kluwer Health in Neurology
- Vol. 104 (2) , e210234
Accuracy of a Rapid-Response EEG's Automated Seizure-Burden Estimator
The use of rapid response EEG (rr-EEG) has recently expanded in limited-resource settings and as a supplement to conventional EEG to rapidly detect and treat nonconvulsive status epilepticus. The study objective was to test the accuracy of an rr-EEG's automated seizure burden estimator (ASBE). This is a retrospective observational study using multiple blinded reviewers. All consecutive clinical rr-EEG procedures performed between November 2019 and February 2021 at Yale New Haven Hospital, one affiliated community hospital, and one affiliated inner-city regional hospital were included. Three reviewers blindly reviewed each EEG. The reference standard was 2/3 agreement. The co-primary outcome measures were the negative predictive value (NPV) of the ASBE for the detection of electrographic status epilepticus (ESE) or possible ESE (ESE/pESE) (to be used as a screening method to exclude ESE without the need for urgent expert review) and the positive predictive value (PPV, to be used for immediate treatment without requiring urgent expert review). These were assessed using a variety of seizure burden cutoffs determined by the algorithm (>1%, >10%, >20%, >50%, and >90%). In the first 2 hours, a >10% burden cutoff detected 86% (95% CI 42%-100%) of studies with ESE alone and 88% (68%-97%) with ESE/pESE; this >10% cutoff had a NPV of 99% (97%-100%) for ESE and 98% (95%-100%) for ESE/pESE. The specificity at this threshold was 79% (73%-84%) for ESE and 84% (79%-89%) for ESE/pESE, but the PPV was low at 11% (4%-23%) for ESE and 39% (26%-53%) for ESE/pESE. A >90% burden cutoff was 97% (94%-99%) specific for detecting ESE (PPV 33% [7%-70%]) and 99% (97%-100%) specific for detecting ESE/pESE [PPV 78% (40%-97%)], although the sensitivity dropped significantly to 29% (13%-51%) for ESE/pESE and 43% (10%-82%) for ESE at the >90% threshold. The ASBE has high specificity at >90% seizure burden threshold for detecting ESE and ESE/pESE, with good PPV for ESE/pESE, though with only low-to-moderate sensitivity; at this threshold, it can be used to help triage patients for immediate treatment/transfer, urgent expert review, and additional CEEG. A >10% threshold has a high sensitivity, detecting approximately 85% of patients with ESE; at this lower cutoff, it can be used as a screening tool to exclude ESE with >95% NPV. This study provides Class II evidence that ASBE software can reliably exclude ESE (98% negative predictive value using a <10% burden cutoff) without expert review in most patients requiring rapid response EEG.
- 28 January 2025
- Published by Wolters Kluwer Health in Neurology
- Vol. 104 (2) , e210234
Accuracy of a Rapid-Response EEG's Automated Seizure-Burden Estimator
The use of rapid response EEG (rr-EEG) has recently expanded in limited-resource settings and as a supplement to conventional EEG to rapidly detect and treat nonconvulsive status epilepticus. The study objective was to test the accuracy of an rr-EEG's automated seizure burden estimator (ASBE). This is a retrospective observational study using multiple blinded reviewers. All consecutive clinical rr-EEG procedures performed between November 2019 and February 2021 at Yale New Haven Hospital, one affiliated community hospital, and one affiliated inner-city regional hospital were included. Three reviewers blindly reviewed each EEG. The reference standard was 2/3 agreement. The co-primary outcome measures were the negative predictive value (NPV) of the ASBE for the detection of electrographic status epilepticus (ESE) or possible ESE (ESE/pESE) (to be used as a screening method to exclude ESE without the need for urgent expert review) and the positive predictive value (PPV, to be used for immediate treatment without requiring urgent expert review). These were assessed using a variety of seizure burden cutoffs determined by the algorithm (>1%, >10%, >20%, >50%, and >90%). In the first 2 hours, a >10% burden cutoff detected 86% (95% CI 42%-100%) of studies with ESE alone and 88% (68%-97%) with ESE/pESE; this >10% cutoff had a NPV of 99% (97%-100%) for ESE and 98% (95%-100%) for ESE/pESE. The specificity at this threshold was 79% (73%-84%) for ESE and 84% (79%-89%) for ESE/pESE, but the PPV was low at 11% (4%-23%) for ESE and 39% (26%-53%) for ESE/pESE. A >90% burden cutoff was 97% (94%-99%) specific for detecting ESE (PPV 33% [7%-70%]) and 99% (97%-100%) specific for detecting ESE/pESE [PPV 78% (40%-97%)], although the sensitivity dropped significantly to 29% (13%-51%) for ESE/pESE and 43% (10%-82%) for ESE at the >90% threshold. The ASBE has high specificity at >90% seizure burden threshold for detecting ESE and ESE/pESE, with good PPV for ESE/pESE, though with only low-to-moderate sensitivity; at this threshold, it can be used to help triage patients for immediate treatment/transfer, urgent expert review, and additional CEEG. A >10% threshold has a high sensitivity, detecting approximately 85% of patients with ESE; at this lower cutoff, it can be used as a screening tool to exclude ESE with >95% NPV. This study provides Class II evidence that ASBE software can reliably exclude ESE (98% negative predictive value using a <10% burden cutoff) without expert review in most patients requiring rapid response EEG.
- 25 April 2023
- Published by Wolters Kluwer Health in Neurology
- Vol. 100 (17) , E1737-E1749
Interrater Reliability of Expert Electroencephalographers Identifying Seizures and Rhythmic and Periodic Patterns in EEGs
Background and Objectives: The validity of brain monitoring using electroencephalography (EEG), particularly to guide care in patients with acute or critical illness, requires that experts can reliably identify seizures and other potentially harmful rhythmic and periodic brain activity, collectively referred to as “ictal-interictal-injury continuum" (IIIC). Prior inter-rater reliability (IRR) studies are limited by small samples and selection bias. This study was conducted to assess the reliability of experts in identifying IIIC. Methods: This prospective analysis included 30 experts with subspecialty clinical neurophysiology training from 18 institutions. Experts independently scored varying numbers of ten-second EEG segments as: “Seizure (SZ)”, “Lateralized Periodic Discharges (LPD)”, “Generalized Periodic Discharges (GPD)”, “Lateralized Rhythmic Delta Activity (LRDA)”, “Generalized Rhythmic Delta Activity (GRDA)”, or “Other”. EEGs were performed for clinical indications at Massachusetts General Hospital between 2006 to 2020. Primary outcome measures were pairwise IRR (average percent agreement (PA) between pairs of experts) and majority IRR (average PA with group consensus) for each class; and beyond chance agreement (κ). Secondary outcomes were calibration of expert scoring to group consensus, and latent trait analysis to investigate contributions of bias and noise to scoring variability. Results: Among 2,711 EEGs, 49% were from females, and median (IQR) age was 55 (41). In total experts scored 50,697 EEG segments; the median [range] number scored by each expert was 6,287.5 [1,002, 45,267]. Overall pairwise IRR was moderate (PA 52%, κ 42%), and majority IRR was substantial (PA 65%, κ 61%). Noise-bias analysis demonstrated that a single underlying receiver operating curve can account for most variation in experts9 false positive vs true positive characteristics (median [range] of variance explained (R2): 95 [93, 98]%), and for most variation in experts’ precision vs sensitivity characteristics (R2: 75 [59, 89]%). Thus, variation between experts is mostly attributable not to differences in expertise, but rather to variation in decision thresholds. Discussion: Our results provide precise estimates of expert reliability from a large and diverse sample, and a parsimonious theory to explain the origin of disagreements between experts. The results also establish a standard for how well an automated IIIC classifier must perform to match experts. Classification of Evidence: This study provides Class II evidence that independent expert review reliably identifies ictal-interictal injury continuum patterns on EEG compared to expert consensus.
- 25 April 2023
- Published by Wolters Kluwer Health in Neurology
- Vol. 100 (17) , E1737-E1749
Interrater Reliability of Expert Electroencephalographers Identifying Seizures and Rhythmic and Periodic Patterns in EEGs
Background and Objectives: The validity of brain monitoring using electroencephalography (EEG), particularly to guide care in patients with acute or critical illness, requires that experts can reliably identify seizures and other potentially harmful rhythmic and periodic brain activity, collectively referred to as “ictal-interictal-injury continuum" (IIIC). Prior inter-rater reliability (IRR) studies are limited by small samples and selection bias. This study was conducted to assess the reliability of experts in identifying IIIC. Methods: This prospective analysis included 30 experts with subspecialty clinical neurophysiology training from 18 institutions. Experts independently scored varying numbers of ten-second EEG segments as: “Seizure (SZ)”, “Lateralized Periodic Discharges (LPD)”, “Generalized Periodic Discharges (GPD)”, “Lateralized Rhythmic Delta Activity (LRDA)”, “Generalized Rhythmic Delta Activity (GRDA)”, or “Other”. EEGs were performed for clinical indications at Massachusetts General Hospital between 2006 to 2020. Primary outcome measures were pairwise IRR (average percent agreement (PA) between pairs of experts) and majority IRR (average PA with group consensus) for each class; and beyond chance agreement (κ). Secondary outcomes were calibration of expert scoring to group consensus, and latent trait analysis to investigate contributions of bias and noise to scoring variability. Results: Among 2,711 EEGs, 49% were from females, and median (IQR) age was 55 (41). In total experts scored 50,697 EEG segments; the median [range] number scored by each expert was 6,287.5 [1,002, 45,267]. Overall pairwise IRR was moderate (PA 52%, κ 42%), and majority IRR was substantial (PA 65%, κ 61%). Noise-bias analysis demonstrated that a single underlying receiver operating curve can account for most variation in experts9 false positive vs true positive characteristics (median [range] of variance explained (R2): 95 [93, 98]%), and for most variation in experts’ precision vs sensitivity characteristics (R2: 75 [59, 89]%). Thus, variation between experts is mostly attributable not to differences in expertise, but rather to variation in decision thresholds. Discussion: Our results provide precise estimates of expert reliability from a large and diverse sample, and a parsimonious theory to explain the origin of disagreements between experts. The results also establish a standard for how well an automated IIIC classifier must perform to match experts. Classification of Evidence: This study provides Class II evidence that independent expert review reliably identifies ictal-interictal injury continuum patterns on EEG compared to expert consensus.
- 1 May 2018
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 35 (3) , 218-228
Generalized and Lateralized Rhythmic Patterns
Summary: The relationship between generalized and lateralized rhythmic delta activity (RDA) and seizures is more ambiguous than the relationship between periodic discharges and seizures. Although frontally predominant generalized RDA is not associated with seizures, occipitally predominant RDA may be associated with the absence of seizures. Lateralized RDA seems to be more strongly associated with the presence of seizure activity. Appropriate recognition of generalized RDA and lateralized rhythmic delta activity may be confounded by benign etiologies of RDA, such as phi rhythm, slow alpha variant, subclinical rhythmic electrographic discharges of adults, or hyperventilation-induced high-amplitude rhythmic slowing. Angelman syndrome and NMDA-receptor antibody encephalitis can also produce morphologically distinct patterns of RDA.
- 1 May 2018
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 35 (3) , 218-228
Generalized and Lateralized Rhythmic Patterns
Summary: The relationship between generalized and lateralized rhythmic delta activity (RDA) and seizures is more ambiguous than the relationship between periodic discharges and seizures. Although frontally predominant generalized RDA is not associated with seizures, occipitally predominant RDA may be associated with the absence of seizures. Lateralized RDA seems to be more strongly associated with the presence of seizure activity. Appropriate recognition of generalized RDA and lateralized rhythmic delta activity may be confounded by benign etiologies of RDA, such as phi rhythm, slow alpha variant, subclinical rhythmic electrographic discharges of adults, or hyperventilation-induced high-amplitude rhythmic slowing. Angelman syndrome and NMDA-receptor antibody encephalitis can also produce morphologically distinct patterns of RDA.
- 14 February 2018
- Published by Springer Nature in Current Neurology and Neuroscience Reports
- Vol. 18 (3) , 10
Treating Immune-Related Epilepsy
This review explores different treatment modalities for immune-mediated epilepsy, including epilepsy caused by autoantibodies as well as epilepsy in the context of systemic autoimmune disease.
- 14 February 2018
- Published by Springer Nature in Current Neurology and Neuroscience Reports
- Vol. 18 (3) , 10
Treating Immune-Related Epilepsy
This review explores different treatment modalities for immune-mediated epilepsy, including epilepsy caused by autoantibodies as well as epilepsy in the context of systemic autoimmune disease.
- 1 March 2017
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 34 (2) , 158-161
Utility of Clinical Features for the Diagnosis of Seizures in the Intensive Care Unit
Purpose: Seizures in the intensive care unit are often subtle, and may have little or no clinical correlate. This study attempts to determine what clinical features are most strongly associated with the presence of electrographic seizures on continuous EEG (cEEG) monitoring. Methods: A retrospective review for all patients who underwent cEEG monitoring between January 2003 and March 2009 for either characterization of clinical events or altered mental status was performed. Clinical events were categorized as (1) limb myoclonus/tremor, (2) extremity weakness, (3) eye movement abnormalities, (4) facial/periorbital twitching, and (5) other abnormal movements. The presence of associated dyscognitive event features was also recorded. Results: Records from 626 patients who underwent cEEG were reviewed—154 for event characterization and 472 for altered mental status. Seizures were captured in 48 patients (31.2%) undergoing cEEG monitoring for characterization of clinical events. This was not significantly different from the incidence of seizures in patients undergoing cEEG for altered mental status (N = 133, 28.2%). Patients undergoing cEEG monitoring for facial/periorbital twitching were significantly more likely to have electrographic seizures (78.9%, P < 0.005) than patients undergoing cEEG for altered mental status or characterization of other types of events. Conclusions: The incidence of seizures in patients in the intensive care unit with clinical events is generally not significantly higher than the incidence of seizures in patients in the intensive care unit with altered mental status. However, the presence of facial/periorbital twitching was associated a higher incidence of electrographic seizures.
- 1 March 2017
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 34 (2) , 158-161
Utility of Clinical Features for the Diagnosis of Seizures in the Intensive Care Unit
Purpose: Seizures in the intensive care unit are often subtle, and may have little or no clinical correlate. This study attempts to determine what clinical features are most strongly associated with the presence of electrographic seizures on continuous EEG (cEEG) monitoring. Methods: A retrospective review for all patients who underwent cEEG monitoring between January 2003 and March 2009 for either characterization of clinical events or altered mental status was performed. Clinical events were categorized as (1) limb myoclonus/tremor, (2) extremity weakness, (3) eye movement abnormalities, (4) facial/periorbital twitching, and (5) other abnormal movements. The presence of associated dyscognitive event features was also recorded. Results: Records from 626 patients who underwent cEEG were reviewed—154 for event characterization and 472 for altered mental status. Seizures were captured in 48 patients (31.2%) undergoing cEEG monitoring for characterization of clinical events. This was not significantly different from the incidence of seizures in patients undergoing cEEG for altered mental status (N = 133, 28.2%). Patients undergoing cEEG monitoring for facial/periorbital twitching were significantly more likely to have electrographic seizures (78.9%, P < 0.005) than patients undergoing cEEG for altered mental status or characterization of other types of events. Conclusions: The incidence of seizures in patients in the intensive care unit with clinical events is generally not significantly higher than the incidence of seizures in patients in the intensive care unit with altered mental status. However, the presence of facial/periorbital twitching was associated a higher incidence of electrographic seizures.
- 1 April 2016
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 33 (2) , 133-140
Development and Feasibility Testing of a Critical Care EEG Monitoring Database for Standardized Clinical Reporting and Multicenter Collaborative Research
Purpose: The rapid expansion of the use of continuous critical care electroencephalogram (cEEG) monitoring and resulting multicenter research studies through the Critical Care EEG Monitoring Research Consortium has created the need for a collaborative data sharing mechanism and repository. The authors describe the development of a research database incorporating the American Clinical Neurophysiology Society standardized terminology for critical care EEG monitoring. The database includes flexible report generation tools that allow for daily clinical use. Methods: Key clinical and research variables were incorporated into a Microsoft Access database. To assess its utility for multicenter research data collection, the authors performed a 21-center feasibility study in which each center entered data from 12 consecutive intensive care unit monitoring patients. To assess its utility as a clinical report generating tool, three large volume centers used it to generate daily clinical critical care EEG reports. Results: A total of 280 subjects were enrolled in the multicenter feasibility study. The duration of recording (median, 25.5 hours) varied significantly between the centers. The incidence of seizure (17.6%), periodic/rhythmic discharges (35.7%), and interictal epileptiform discharges (11.8%) was similar to previous studies. The database was used as a clinical reporting tool by 3 centers that entered a total of 3,144 unique patients covering 6,665 recording days. Conclusions: The Critical Care EEG Monitoring Research Consortium database has been successfully developed and implemented with a dual role as a collaborative research platform and a clinical reporting tool. It is now available for public download to be used as a clinical data repository and report generating tool.
- 1 April 2016
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 33 (2) , 133-140
Development and Feasibility Testing of a Critical Care EEG Monitoring Database for Standardized Clinical Reporting and Multicenter Collaborative Research
Purpose: The rapid expansion of the use of continuous critical care electroencephalogram (cEEG) monitoring and resulting multicenter research studies through the Critical Care EEG Monitoring Research Consortium has created the need for a collaborative data sharing mechanism and repository. The authors describe the development of a research database incorporating the American Clinical Neurophysiology Society standardized terminology for critical care EEG monitoring. The database includes flexible report generation tools that allow for daily clinical use. Methods: Key clinical and research variables were incorporated into a Microsoft Access database. To assess its utility for multicenter research data collection, the authors performed a 21-center feasibility study in which each center entered data from 12 consecutive intensive care unit monitoring patients. To assess its utility as a clinical report generating tool, three large volume centers used it to generate daily clinical critical care EEG reports. Results: A total of 280 subjects were enrolled in the multicenter feasibility study. The duration of recording (median, 25.5 hours) varied significantly between the centers. The incidence of seizure (17.6%), periodic/rhythmic discharges (35.7%), and interictal epileptiform discharges (11.8%) was similar to previous studies. The database was used as a clinical reporting tool by 3 centers that entered a total of 3,144 unique patients covering 6,665 recording days. Conclusions: The Critical Care EEG Monitoring Research Consortium database has been successfully developed and implemented with a dual role as a collaborative research platform and a clinical reporting tool. It is now available for public download to be used as a clinical data repository and report generating tool.
- 1 March 2016
- Published by Wolters Kluwer Health in Journal of Head Trauma Rehabilitation
- Vol. 31 (2) , 101-107
Sleep Features on Continuous Electroencephalography Predict Rehabilitation Outcomes After Severe Traumatic Brain Injury
Objective: Sleep characteristics detected by electroencephalography (EEG) may be predictive of neurological recovery and rehabilitation outcomes after traumatic brain injury (TBI). We sought to determine whether sleep features were associated with greater access to rehabilitation therapies and better functional outcomes after severe TBI. Methods: We retrospectively reviewed records of patients admitted with severe TBI who underwent 24 or more hours of continuous EEG (cEEG) monitoring within 14 days of injury for sleep elements and ictal activity. Patient outcomes included discharge disposition and modified Rankin Scale (mRS). Results: A total of 64 patients underwent cEEG monitoring for a mean of 50.6 hours. Status epilepticus or electrographic seizures detected by cEEG were associated with poor outcomes (death or discharge to skilled nursing facility). Sleep characteristics were present in 19 (30%) and associated with better outcome (89% discharged to home/acute rehabilitation; P = .0002). Lack of sleep elements on cEEG correlated with a poor outcome or mRS > 4 at hospital discharge (P = .012). Of those patients who were transferred to skilled nursing/acute rehabilitation, sleep architecture on cEEG associated with a shorter inpatient hospital stay (20 days vs 27 days) and earlier participation in therapy (9.8 days vs 13.2 days postinjury). Multivariable analyses indicated that sleep features on cEEG predicted functional outcomes independent of admission Glasgow Coma Scale and ictal-interictal activity. Conclusion: The presence of sleep features in the acute period after TBI indicates earlier participation in rehabilitative therapies and a better functional recovery. By contrast, status epilepticus, other ictal activity, or absent sleep architecture may portend a worse prognosis. Whether sleep elements detected by EEG predict long-term prognosis remains to be determined.
- 1 March 2016
- Published by Wolters Kluwer Health in Journal of Head Trauma Rehabilitation
- Vol. 31 (2) , 101-107
Sleep Features on Continuous Electroencephalography Predict Rehabilitation Outcomes After Severe Traumatic Brain Injury
Objective: Sleep characteristics detected by electroencephalography (EEG) may be predictive of neurological recovery and rehabilitation outcomes after traumatic brain injury (TBI). We sought to determine whether sleep features were associated with greater access to rehabilitation therapies and better functional outcomes after severe TBI. Methods: We retrospectively reviewed records of patients admitted with severe TBI who underwent 24 or more hours of continuous EEG (cEEG) monitoring within 14 days of injury for sleep elements and ictal activity. Patient outcomes included discharge disposition and modified Rankin Scale (mRS). Results: A total of 64 patients underwent cEEG monitoring for a mean of 50.6 hours. Status epilepticus or electrographic seizures detected by cEEG were associated with poor outcomes (death or discharge to skilled nursing facility). Sleep characteristics were present in 19 (30%) and associated with better outcome (89% discharged to home/acute rehabilitation; P = .0002). Lack of sleep elements on cEEG correlated with a poor outcome or mRS > 4 at hospital discharge (P = .012). Of those patients who were transferred to skilled nursing/acute rehabilitation, sleep architecture on cEEG associated with a shorter inpatient hospital stay (20 days vs 27 days) and earlier participation in therapy (9.8 days vs 13.2 days postinjury). Multivariable analyses indicated that sleep features on cEEG predicted functional outcomes independent of admission Glasgow Coma Scale and ictal-interictal activity. Conclusion: The presence of sleep features in the acute period after TBI indicates earlier participation in rehabilitative therapies and a better functional recovery. By contrast, status epilepticus, other ictal activity, or absent sleep architecture may portend a worse prognosis. Whether sleep elements detected by EEG predict long-term prognosis remains to be determined.
- Top Cited Papers
- 3 November 2015
- Published by Wolters Kluwer Health in Neurology
- Vol. 85 (18) , 1604-1613
New-onset refractory status epilepticus
Objectives: The aims of this study were to determine the etiology, clinical features, and predictors of outcome of new-onset refractory status epilepticus. Methods: Retrospective review of patients with refractory status epilepticus without etiology identified within 48 hours of admission between January 1, 2008, and December 31, 2013, in 13 academic medical centers. The primary outcome measure was poor functional outcome at discharge (defined as a score >3 on the modified Rankin Scale). Results: Of 130 cases, 67 (52%) remained cryptogenic. The most common identified etiologies were autoimmune (19%) and paraneoplastic (18%) encephalitis. Full data were available in 125 cases (62 cryptogenic). Poor outcome occurred in 77 of 125 cases (62%), and 28 (22%) died. Predictors of poor outcome included duration of status epilepticus, use of anesthetics, and medical complications. Among the 63 patients with available follow-up data (median 9 months), functional status improved in 36 (57%); 79% had good or fair outcome at last follow-up, but epilepsy developed in 37% with most survivors (92%) remaining on antiseizure medications. Immune therapies were used less frequently in cryptogenic cases, despite a comparable prevalence of inflammatory CSF changes. Conclusions: Autoimmune encephalitis is the most commonly identified cause of new-onset refractory status epilepticus, but half remain cryptogenic. Outcome at discharge is poor but improves during follow-up. Epilepsy develops in most cases. The role of anesthetics and immune therapies warrants further investigation.
- 3 November 2015
- Published by Wolters Kluwer Health in Neurology
- Vol. 85 (18) , 1604-1613
Top Cited PapersNew-onset refractory status epilepticus
Objectives: The aims of this study were to determine the etiology, clinical features, and predictors of outcome of new-onset refractory status epilepticus. Methods: Retrospective review of patients with refractory status epilepticus without etiology identified within 48 hours of admission between January 1, 2008, and December 31, 2013, in 13 academic medical centers. The primary outcome measure was poor functional outcome at discharge (defined as a score >3 on the modified Rankin Scale). Results: Of 130 cases, 67 (52%) remained cryptogenic. The most common identified etiologies were autoimmune (19%) and paraneoplastic (18%) encephalitis. Full data were available in 125 cases (62 cryptogenic). Poor outcome occurred in 77 of 125 cases (62%), and 28 (22%) died. Predictors of poor outcome included duration of status epilepticus, use of anesthetics, and medical complications. Among the 63 patients with available follow-up data (median 9 months), functional status improved in 36 (57%); 79% had good or fair outcome at last follow-up, but epilepsy developed in 37% with most survivors (92%) remaining on antiseizure medications. Immune therapies were used less frequently in cryptogenic cases, despite a comparable prevalence of inflammatory CSF changes. Conclusions: Autoimmune encephalitis is the most commonly identified cause of new-onset refractory status epilepticus, but half remain cryptogenic. Outcome at discharge is poor but improves during follow-up. Epilepsy develops in most cases. The role of anesthetics and immune therapies warrants further investigation.