Zubeda Sheikh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zubeda Sheikh has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Sarah E. Schmitt
Department of Neurology Medical University of South Carolina Charleston South Carolina USA
4 shared publications - Hiba Arif Haider
Department of Neurology University of Chicago Chicago Illinois USA
3 shared publications - Ioannis Karakis
Department of Neurology Emory University School of Medicine Atlanta Georgia USA
3 shared publications - Ji Yeoun Yoo
Icahn School of Medicine at Mount Sinai New York New York USA
3 shared publications - Lawrence J. Hirsch
Department of Neurology Yale School of Medicine New Haven Connecticut USA
3 shared publications - Aaron Frank Struck
Washington University in St. Louis
2 shared publications
Latest Publications
- Open Access
Accuracy of the rapid‐response electroencephalography's Automated Seizure Burden Estimator: A follow‐up validation study of version 8 ( AccuRASE II )
Objective: Ceribell Inc.'s point‐of‐care electroencephalographic (EEG) system and artificial intelligence‐based Automated Seizure Burden Estimator (ASBE; ClarityPro) have US Food and Drug Administration clearance for diagnosing electrographic status epilepticus (ESE). The AccuRASE study using ASBE version 6 (V6) showed high negative predictive value (NPV) but limited sensitivity and positive predictive value (PPV) at certain thresholds. Version 8 (V8) is the updated algorithm trained with additional EEG samples. Methods: We tested V8 on the previously used rapid‐response EEG test dataset (not used to train V8). Sensitivity, specificity, PPV, and NPV were compared against blinded expert annotations. ESE, ESE and possible ESE (ESE/pESE), electrographic seizures (ESz), and Esz with highly epileptiform patterns (Esz/HEPs) at burden thresholds of >1%, >10%, >20%, >50%, and >90% were analyzed. Additionally, we evaluated the built‐in ESE and ESE/pESE alerts (≥90% over 5 min, ≥20% over 1 h, or ≥10 continuous minutes of seizure). Results: V8 showed 100% sensitivity at lower thresholds (>10%–20%) for ESE (V6 .86), without a specificity loss (V8 .9 vs. V6 .85), and retained NPV (V8 1.0 vs. V6 .99). Sensitivity at 50% threshold was .86 for ESE (V6 .71), and specificity was .94 (V6 .91); PPV for ESE was 30% for ESE and 80% for ESE/pESE. The specificity for ESE remained high for 90% burden (V8 .96, V6 .97) but the sensitivity dropped (.29 vs. V6 .43). Sensitivity was lower for ESz/HEPs (.54 → .44 at >10% threshold), although the algorithm is not designed to detect HEPs. Built‐in alert analysis showed significantly improved sensitivity for ESE (.57 → .86); specificity and NPV remained high (>.94). Significance: ASBE V8 showed meaningful improvements in sensitivity, continued excellent NPV, and improved built‐in alert accuracy for ESE and ESE/pESE. The best seizure burden threshold for ruling out ESE now is 20% (vs. 10% with V6) and that for ruling in ESE/pESE with reasonable certainty is 50% (vs. 90% with V6).
Open AccessAccuracy of the rapid‐response electroencephalography's Automated Seizure Burden Estimator: A follow‐up validation study of version 8 ( AccuRASE II )
Objective: Ceribell Inc.'s point‐of‐care electroencephalographic (EEG) system and artificial intelligence‐based Automated Seizure Burden Estimator (ASBE; ClarityPro) have US Food and Drug Administration clearance for diagnosing electrographic status epilepticus (ESE). The AccuRASE study using ASBE version 6 (V6) showed high negative predictive value (NPV) but limited sensitivity and positive predictive value (PPV) at certain thresholds. Version 8 (V8) is the updated algorithm trained with additional EEG samples. Methods: We tested V8 on the previously used rapid‐response EEG test dataset (not used to train V8). Sensitivity, specificity, PPV, and NPV were compared against blinded expert annotations. ESE, ESE and possible ESE (ESE/pESE), electrographic seizures (ESz), and Esz with highly epileptiform patterns (Esz/HEPs) at burden thresholds of >1%, >10%, >20%, >50%, and >90% were analyzed. Additionally, we evaluated the built‐in ESE and ESE/pESE alerts (≥90% over 5 min, ≥20% over 1 h, or ≥10 continuous minutes of seizure). Results: V8 showed 100% sensitivity at lower thresholds (>10%–20%) for ESE (V6 .86), without a specificity loss (V8 .9 vs. V6 .85), and retained NPV (V8 1.0 vs. V6 .99). Sensitivity at 50% threshold was .86 for ESE (V6 .71), and specificity was .94 (V6 .91); PPV for ESE was 30% for ESE and 80% for ESE/pESE. The specificity for ESE remained high for 90% burden (V8 .96, V6 .97) but the sensitivity dropped (.29 vs. V6 .43). Sensitivity was lower for ESz/HEPs (.54 → .44 at >10% threshold), although the algorithm is not designed to detect HEPs. Built‐in alert analysis showed significantly improved sensitivity for ESE (.57 → .86); specificity and NPV remained high (>.94). Significance: ASBE V8 showed meaningful improvements in sensitivity, continued excellent NPV, and improved built‐in alert accuracy for ESE and ESE/pESE. The best seizure burden threshold for ruling out ESE now is 20% (vs. 10% with V6) and that for ruling in ESE/pESE with reasonable certainty is 50% (vs. 90% with V6).
- 26 June 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (7)
Expert-Level Detection of Epilepsy Markers in EEG on Short and Long Timescales
Epileptiform discharges, or spikes, within electroencephalogram (EEG) recordings are essential for diagnosing epilepsy and localizing seizure origins. Artificial intelligence (AI) offers a promising approach to automating detection, but current models are often hindered by artifact-related false positives and often target either event- or EEG-level classification, thus limiting clinical utility. We developed SpikeNet2, a deep-learning model based on a residual network architecture, and enhanced it with hard-negative mining to reduce false positives. Our study analyzed 17,812 EEG recordings from 13,523 patients across multiple institutions, including Massachusetts General Brigham (MGB) hospitals. Data from the Human Epilepsy Project (HEP) and SCORE-AI (SAI) were also included. A total of 32,433 event-level samples, labeled by experts, were used for training and evaluation. Performance was assessed using the area under the receiver operating characteristic curve (AUROC), the area under the precision–recall curve (AUPRC), calibration error, and a modified area under the curve (mAUC) metric. The model’s generalizability was evaluated using external datasets. SpikeNet2 demonstrated strong performance in event-level spike detection, achieving an AUROC of 0.973 and an AUPRC of 0.995, with 44% of experts surpassing the model on the MGB dataset. In external validation, the model achieved an AUROC of 0.942 and an AUPRC of 0.948 on the HEP dataset. For EEG-level classification, SpikeNet2 recorded an AUROC of 0.958 and an AUPRC of 0.959 on the MGB dataset, an AUROC of 0.888 and an AUPRC of 0.823 on the HEP dataset, and an AUROC of 0.995 and an AUPRC of 0.991 on the SAI dataset, with 32% of experts outperforming the model. The false-positive rate was reduced to an average of nine spikes per hour. SpikeNet2 offers expert-level accuracy in both event-level spike detection and EEG-level classification, while significantly reducing false positives. Its dual functionality and robust performance across diverse datasets make it a promising tool for clinical and telemedicine applications, particularly in resource-limited settings. (Funded by the National Institutes of Health and others.)
- 26 June 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (7)
Expert-Level Detection of Epilepsy Markers in EEG on Short and Long Timescales
Epileptiform discharges, or spikes, within electroencephalogram (EEG) recordings are essential for diagnosing epilepsy and localizing seizure origins. Artificial intelligence (AI) offers a promising approach to automating detection, but current models are often hindered by artifact-related false positives and often target either event- or EEG-level classification, thus limiting clinical utility. We developed SpikeNet2, a deep-learning model based on a residual network architecture, and enhanced it with hard-negative mining to reduce false positives. Our study analyzed 17,812 EEG recordings from 13,523 patients across multiple institutions, including Massachusetts General Brigham (MGB) hospitals. Data from the Human Epilepsy Project (HEP) and SCORE-AI (SAI) were also included. A total of 32,433 event-level samples, labeled by experts, were used for training and evaluation. Performance was assessed using the area under the receiver operating characteristic curve (AUROC), the area under the precision–recall curve (AUPRC), calibration error, and a modified area under the curve (mAUC) metric. The model’s generalizability was evaluated using external datasets. SpikeNet2 demonstrated strong performance in event-level spike detection, achieving an AUROC of 0.973 and an AUPRC of 0.995, with 44% of experts surpassing the model on the MGB dataset. In external validation, the model achieved an AUROC of 0.942 and an AUPRC of 0.948 on the HEP dataset. For EEG-level classification, SpikeNet2 recorded an AUROC of 0.958 and an AUPRC of 0.959 on the MGB dataset, an AUROC of 0.888 and an AUPRC of 0.823 on the HEP dataset, and an AUROC of 0.995 and an AUPRC of 0.991 on the SAI dataset, with 32% of experts outperforming the model. The false-positive rate was reduced to an average of nine spikes per hour. SpikeNet2 offers expert-level accuracy in both event-level spike detection and EEG-level classification, while significantly reducing false positives. Its dual functionality and robust performance across diverse datasets make it a promising tool for clinical and telemedicine applications, particularly in resource-limited settings. (Funded by the National Institutes of Health and others.)
- 28 January 2025
- Published by Wolters Kluwer Health in Neurology
- Vol. 104 (2) , e210234
Accuracy of a Rapid-Response EEG's Automated Seizure-Burden Estimator
The use of rapid response EEG (rr-EEG) has recently expanded in limited-resource settings and as a supplement to conventional EEG to rapidly detect and treat nonconvulsive status epilepticus. The study objective was to test the accuracy of an rr-EEG's automated seizure burden estimator (ASBE). This is a retrospective observational study using multiple blinded reviewers. All consecutive clinical rr-EEG procedures performed between November 2019 and February 2021 at Yale New Haven Hospital, one affiliated community hospital, and one affiliated inner-city regional hospital were included. Three reviewers blindly reviewed each EEG. The reference standard was 2/3 agreement. The co-primary outcome measures were the negative predictive value (NPV) of the ASBE for the detection of electrographic status epilepticus (ESE) or possible ESE (ESE/pESE) (to be used as a screening method to exclude ESE without the need for urgent expert review) and the positive predictive value (PPV, to be used for immediate treatment without requiring urgent expert review). These were assessed using a variety of seizure burden cutoffs determined by the algorithm (>1%, >10%, >20%, >50%, and >90%). In the first 2 hours, a >10% burden cutoff detected 86% (95% CI 42%-100%) of studies with ESE alone and 88% (68%-97%) with ESE/pESE; this >10% cutoff had a NPV of 99% (97%-100%) for ESE and 98% (95%-100%) for ESE/pESE. The specificity at this threshold was 79% (73%-84%) for ESE and 84% (79%-89%) for ESE/pESE, but the PPV was low at 11% (4%-23%) for ESE and 39% (26%-53%) for ESE/pESE. A >90% burden cutoff was 97% (94%-99%) specific for detecting ESE (PPV 33% [7%-70%]) and 99% (97%-100%) specific for detecting ESE/pESE [PPV 78% (40%-97%)], although the sensitivity dropped significantly to 29% (13%-51%) for ESE/pESE and 43% (10%-82%) for ESE at the >90% threshold. The ASBE has high specificity at >90% seizure burden threshold for detecting ESE and ESE/pESE, with good PPV for ESE/pESE, though with only low-to-moderate sensitivity; at this threshold, it can be used to help triage patients for immediate treatment/transfer, urgent expert review, and additional CEEG. A >10% threshold has a high sensitivity, detecting approximately 85% of patients with ESE; at this lower cutoff, it can be used as a screening tool to exclude ESE with >95% NPV. This study provides Class II evidence that ASBE software can reliably exclude ESE (98% negative predictive value using a <10% burden cutoff) without expert review in most patients requiring rapid response EEG.
- 28 January 2025
- Published by Wolters Kluwer Health in Neurology
- Vol. 104 (2) , e210234
Accuracy of a Rapid-Response EEG's Automated Seizure-Burden Estimator
The use of rapid response EEG (rr-EEG) has recently expanded in limited-resource settings and as a supplement to conventional EEG to rapidly detect and treat nonconvulsive status epilepticus. The study objective was to test the accuracy of an rr-EEG's automated seizure burden estimator (ASBE). This is a retrospective observational study using multiple blinded reviewers. All consecutive clinical rr-EEG procedures performed between November 2019 and February 2021 at Yale New Haven Hospital, one affiliated community hospital, and one affiliated inner-city regional hospital were included. Three reviewers blindly reviewed each EEG. The reference standard was 2/3 agreement. The co-primary outcome measures were the negative predictive value (NPV) of the ASBE for the detection of electrographic status epilepticus (ESE) or possible ESE (ESE/pESE) (to be used as a screening method to exclude ESE without the need for urgent expert review) and the positive predictive value (PPV, to be used for immediate treatment without requiring urgent expert review). These were assessed using a variety of seizure burden cutoffs determined by the algorithm (>1%, >10%, >20%, >50%, and >90%). In the first 2 hours, a >10% burden cutoff detected 86% (95% CI 42%-100%) of studies with ESE alone and 88% (68%-97%) with ESE/pESE; this >10% cutoff had a NPV of 99% (97%-100%) for ESE and 98% (95%-100%) for ESE/pESE. The specificity at this threshold was 79% (73%-84%) for ESE and 84% (79%-89%) for ESE/pESE, but the PPV was low at 11% (4%-23%) for ESE and 39% (26%-53%) for ESE/pESE. A >90% burden cutoff was 97% (94%-99%) specific for detecting ESE (PPV 33% [7%-70%]) and 99% (97%-100%) specific for detecting ESE/pESE [PPV 78% (40%-97%)], although the sensitivity dropped significantly to 29% (13%-51%) for ESE/pESE and 43% (10%-82%) for ESE at the >90% threshold. The ASBE has high specificity at >90% seizure burden threshold for detecting ESE and ESE/pESE, with good PPV for ESE/pESE, though with only low-to-moderate sensitivity; at this threshold, it can be used to help triage patients for immediate treatment/transfer, urgent expert review, and additional CEEG. A >10% threshold has a high sensitivity, detecting approximately 85% of patients with ESE; at this lower cutoff, it can be used as a screening tool to exclude ESE with >95% NPV. This study provides Class II evidence that ASBE software can reliably exclude ESE (98% negative predictive value using a <10% burden cutoff) without expert review in most patients requiring rapid response EEG.
- 25 April 2023
- Published by Wolters Kluwer Health in Neurology
- Vol. 100 (17) , E1737-E1749
Interrater Reliability of Expert Electroencephalographers Identifying Seizures and Rhythmic and Periodic Patterns in EEGs
Background and Objectives: The validity of brain monitoring using electroencephalography (EEG), particularly to guide care in patients with acute or critical illness, requires that experts can reliably identify seizures and other potentially harmful rhythmic and periodic brain activity, collectively referred to as “ictal-interictal-injury continuum" (IIIC). Prior inter-rater reliability (IRR) studies are limited by small samples and selection bias. This study was conducted to assess the reliability of experts in identifying IIIC. Methods: This prospective analysis included 30 experts with subspecialty clinical neurophysiology training from 18 institutions. Experts independently scored varying numbers of ten-second EEG segments as: “Seizure (SZ)”, “Lateralized Periodic Discharges (LPD)”, “Generalized Periodic Discharges (GPD)”, “Lateralized Rhythmic Delta Activity (LRDA)”, “Generalized Rhythmic Delta Activity (GRDA)”, or “Other”. EEGs were performed for clinical indications at Massachusetts General Hospital between 2006 to 2020. Primary outcome measures were pairwise IRR (average percent agreement (PA) between pairs of experts) and majority IRR (average PA with group consensus) for each class; and beyond chance agreement (κ). Secondary outcomes were calibration of expert scoring to group consensus, and latent trait analysis to investigate contributions of bias and noise to scoring variability. Results: Among 2,711 EEGs, 49% were from females, and median (IQR) age was 55 (41). In total experts scored 50,697 EEG segments; the median [range] number scored by each expert was 6,287.5 [1,002, 45,267]. Overall pairwise IRR was moderate (PA 52%, κ 42%), and majority IRR was substantial (PA 65%, κ 61%). Noise-bias analysis demonstrated that a single underlying receiver operating curve can account for most variation in experts9 false positive vs true positive characteristics (median [range] of variance explained (R2): 95 [93, 98]%), and for most variation in experts’ precision vs sensitivity characteristics (R2: 75 [59, 89]%). Thus, variation between experts is mostly attributable not to differences in expertise, but rather to variation in decision thresholds. Discussion: Our results provide precise estimates of expert reliability from a large and diverse sample, and a parsimonious theory to explain the origin of disagreements between experts. The results also establish a standard for how well an automated IIIC classifier must perform to match experts. Classification of Evidence: This study provides Class II evidence that independent expert review reliably identifies ictal-interictal injury continuum patterns on EEG compared to expert consensus.
- 25 April 2023
- Published by Wolters Kluwer Health in Neurology
- Vol. 100 (17) , E1737-E1749
Interrater Reliability of Expert Electroencephalographers Identifying Seizures and Rhythmic and Periodic Patterns in EEGs
Background and Objectives: The validity of brain monitoring using electroencephalography (EEG), particularly to guide care in patients with acute or critical illness, requires that experts can reliably identify seizures and other potentially harmful rhythmic and periodic brain activity, collectively referred to as “ictal-interictal-injury continuum" (IIIC). Prior inter-rater reliability (IRR) studies are limited by small samples and selection bias. This study was conducted to assess the reliability of experts in identifying IIIC. Methods: This prospective analysis included 30 experts with subspecialty clinical neurophysiology training from 18 institutions. Experts independently scored varying numbers of ten-second EEG segments as: “Seizure (SZ)”, “Lateralized Periodic Discharges (LPD)”, “Generalized Periodic Discharges (GPD)”, “Lateralized Rhythmic Delta Activity (LRDA)”, “Generalized Rhythmic Delta Activity (GRDA)”, or “Other”. EEGs were performed for clinical indications at Massachusetts General Hospital between 2006 to 2020. Primary outcome measures were pairwise IRR (average percent agreement (PA) between pairs of experts) and majority IRR (average PA with group consensus) for each class; and beyond chance agreement (κ). Secondary outcomes were calibration of expert scoring to group consensus, and latent trait analysis to investigate contributions of bias and noise to scoring variability. Results: Among 2,711 EEGs, 49% were from females, and median (IQR) age was 55 (41). In total experts scored 50,697 EEG segments; the median [range] number scored by each expert was 6,287.5 [1,002, 45,267]. Overall pairwise IRR was moderate (PA 52%, κ 42%), and majority IRR was substantial (PA 65%, κ 61%). Noise-bias analysis demonstrated that a single underlying receiver operating curve can account for most variation in experts9 false positive vs true positive characteristics (median [range] of variance explained (R2): 95 [93, 98]%), and for most variation in experts’ precision vs sensitivity characteristics (R2: 75 [59, 89]%). Thus, variation between experts is mostly attributable not to differences in expertise, but rather to variation in decision thresholds. Discussion: Our results provide precise estimates of expert reliability from a large and diverse sample, and a parsimonious theory to explain the origin of disagreements between experts. The results also establish a standard for how well an automated IIIC classifier must perform to match experts. Classification of Evidence: This study provides Class II evidence that independent expert review reliably identifies ictal-interictal injury continuum patterns on EEG compared to expert consensus.
- 3 February 2022
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 40 (6) , 553-561
Developing a Standardized Approach to Grading the Level of Brain Dysfunction on EEG
Purpose: To assess variability in interpretation of electroencephalogram (EEG) background activity and qualitative grading of cerebral dysfunction based on EEG findings, including which EEG features are deemed most important in this determination. Methods: A web-based survey (Qualtrics) was disseminated to electroencephalographers practicing in institutions participating in the Critical Care EEG Monitoring Research Consortium between May 2017 and August 2018. Respondents answered 12 questions pertaining to their training and EEG interpretation practices and graded 40 EEG segments (15-second epochs depicting patients' most stimulated state) using a 6-grade scale. Fleiss' Kappa statistic evaluated interrater agreement. Results: Of 110 respondents, 78.2% were attending electroencephalographers with a mean of 8.3 years of experience beyond training. Despite 83% supporting the need for a standardized approach to interpreting the degree of dysfunction on EEG, only 13.6% used a previously published or an institutional grading scale. The overall interrater agreement was fair (k = 0.35). Having Critical Care EEG Monitoring Research Consortium nomenclature certification (40.9%) or EEG board certification (70%) did not improve interrater agreement (k = 0.26). Predominant awake frequencies and posterior dominant rhythm were ranked as the most important variables in grading background dysfunction, followed by continuity and reactivity. Conclusions: Despite the preference for a standardized grading scale for background EEG interpretation, the lack of interrater agreement on levels of dysfunction even among experienced academic electroencephalographers unveils a barrier to the widespread use of EEG as a clinical and research neuromonitoring tool. There was reasonable agreement on the features that are most important in this determination. A standardized approach to grading cerebral dysfunction, currently used by the authors, and based on this work, is proposed.
- 3 February 2022
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 40 (6) , 553-561
Developing a Standardized Approach to Grading the Level of Brain Dysfunction on EEG
Purpose: To assess variability in interpretation of electroencephalogram (EEG) background activity and qualitative grading of cerebral dysfunction based on EEG findings, including which EEG features are deemed most important in this determination. Methods: A web-based survey (Qualtrics) was disseminated to electroencephalographers practicing in institutions participating in the Critical Care EEG Monitoring Research Consortium between May 2017 and August 2018. Respondents answered 12 questions pertaining to their training and EEG interpretation practices and graded 40 EEG segments (15-second epochs depicting patients' most stimulated state) using a 6-grade scale. Fleiss' Kappa statistic evaluated interrater agreement. Results: Of 110 respondents, 78.2% were attending electroencephalographers with a mean of 8.3 years of experience beyond training. Despite 83% supporting the need for a standardized approach to interpreting the degree of dysfunction on EEG, only 13.6% used a previously published or an institutional grading scale. The overall interrater agreement was fair (k = 0.35). Having Critical Care EEG Monitoring Research Consortium nomenclature certification (40.9%) or EEG board certification (70%) did not improve interrater agreement (k = 0.26). Predominant awake frequencies and posterior dominant rhythm were ranked as the most important variables in grading background dysfunction, followed by continuity and reactivity. Conclusions: Despite the preference for a standardized grading scale for background EEG interpretation, the lack of interrater agreement on levels of dysfunction even among experienced academic electroencephalographers unveils a barrier to the widespread use of EEG as a clinical and research neuromonitoring tool. There was reasonable agreement on the features that are most important in this determination. A standardized approach to grading cerebral dysfunction, currently used by the authors, and based on this work, is proposed.
- 7 September 2021
- Published by Wolters Kluwer Health in Neurology
- Vol. 97 (10) , E1057-E1059
Pearls & Oy-sters: Driving Safety in Photosensitive Genetic Generalized Epilepsy
- 7 September 2021
- Published by Wolters Kluwer Health in Neurology
- Vol. 97 (10) , E1057-E1059
Pearls & Oy-sters: Driving Safety in Photosensitive Genetic Generalized Epilepsy
- 1 December 2019
- Published by Wolters Kluwer Health in Neurology Clinical Practice
- Vol. 9 (6) , 513-515
Contralateral ictal ptosis
- 1 December 2019
- Published by Wolters Kluwer Health in Neurology Clinical Practice
- Vol. 9 (6) , 513-515
Contralateral ictal ptosis
- 4 April 2017
- Published by Wolters Kluwer Health in Neurology
- Vol. 88 (14) , e137-e142
Clinical Reasoning: Corpus callosum lesion with multiple strokes
- 4 April 2017
- Published by Wolters Kluwer Health in Neurology
- Vol. 88 (14) , e137-e142
Clinical Reasoning: Corpus callosum lesion with multiple strokes
- 10 May 2016
- Published by Wolters Kluwer Health in Neurology
- Vol. 86 (19) , 1847-1848
Ictal water-seeking in nondominant temporal lobe seizures
- 10 May 2016
- Published by Wolters Kluwer Health in Neurology
- Vol. 86 (19) , 1847-1848
Ictal water-seeking in nondominant temporal lobe seizures
- 8 March 2016
- Published by Wolters Kluwer Health in Neurology
- Vol. 86 (10) , 972-973
Acute retinal necrosis in multiple sclerosis: A neuroimmunologic challenge!
We report a case of a 32-year-old woman with a 2-year history of multiple sclerosis (MS) who presented to the ophthalmology clinic 1 week after the completion of pulse steroids with complaints of blurred vision associated with pain in the left eye. She was treated with 3 courses of high-dose methylprednisolone (1,000 mg a day for 3 days) for recurrent relapses in the 5 months before presentation (brain MRI, figure, A). Her symptoms during these relapses were left hemiparesis, right hemiparesis, and worsening right hemiparesis, in that order. She was started on glatiramer acetate 1 month before presentation. Given the frequent relapses, changing her disease-modifying therapy to natalizumab was being considered.
- 8 March 2016
- Published by Wolters Kluwer Health in Neurology
- Vol. 86 (10) , 972-973
Acute retinal necrosis in multiple sclerosis: A neuroimmunologic challenge!
We report a case of a 32-year-old woman with a 2-year history of multiple sclerosis (MS) who presented to the ophthalmology clinic 1 week after the completion of pulse steroids with complaints of blurred vision associated with pain in the left eye. She was treated with 3 courses of high-dose methylprednisolone (1,000 mg a day for 3 days) for recurrent relapses in the 5 months before presentation (brain MRI, figure, A). Her symptoms during these relapses were left hemiparesis, right hemiparesis, and worsening right hemiparesis, in that order. She was started on glatiramer acetate 1 month before presentation. Given the frequent relapses, changing her disease-modifying therapy to natalizumab was being considered.