Yongqiang Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yongqiang Kang has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
- Shuaibing Li
School of New Energy and Power Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China
33 shared publications - Haiying Dong
School of New Energy and Power Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China
12 shared publications - Yi Cui
School of Electrical Engineering and Computer Science, The University of Queensland, Saint Lucia, Brisbane, QLD, Australia
10 shared publications - Hongwei Li
School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China
8 shared publications - Guangning Wu
Southwest Jiaotong University
6 shared publications - Binglei Cao
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
5 shared publications
Latest Publications
- Open Access
- 21 October 2026
- Published by MDPI AG in Journal of Composites Science
- Vol. 10 (10) , 559
Acoustic and Vibration Fusion-Based Fault Diagnosis for Wind Turbine Blades: A Review from Blade Structure, Fault Modes to Intelligent Diagnosis Methods
Wind turbine blades (WTBs) are critical for wind capture and energy conversion; their condition therefore determines turbine efficiency and safety. Exposed to sustained aerodynamic loading and harsh environments, blades commonly suffer surface erosion, cracking, and delamination that can progress to structural failure. With the rapid expansion of wind power, traditional single-modality monitoring, such as vibration or airborne acoustic sensing, has revealed limitations in information completeness and resistance to interference. Consequently, multimodal fusion diagnosis has gained attention. Because most studies emphasize a single sensing modality and lack systematic reviews linking damage mechanisms, signal responses, and fusion strategies, this paper reviews acoustic-vibration fusion fault diagnosis for WTBs. Beginning with blade material and structural features, we characterize typical damage modes and their progression. We first review single-modality detection methods and highlight their limitations under complex operating conditions, establishing the case for multimodal fusion. We then systematically summarize signal-processing techniques, diagnostic models, and fusion strategies at data, feature, and decision levels. We compare approaches in terms of feature representation capacity, resistance to interference, and engineering applicability. Finally, in light of challenges in acquiring data in complex environments and the emerging role of digital-twin-based dynamic early warning, we outline promising directions for future research.
- 21 October 2026
- Published by MDPI AG in Journal of Composites Science
- Vol. 10 (10) , 559
Open AccessAcoustic and Vibration Fusion-Based Fault Diagnosis for Wind Turbine Blades: A Review from Blade Structure, Fault Modes to Intelligent Diagnosis Methods
Wind turbine blades (WTBs) are critical for wind capture and energy conversion; their condition therefore determines turbine efficiency and safety. Exposed to sustained aerodynamic loading and harsh environments, blades commonly suffer surface erosion, cracking, and delamination that can progress to structural failure. With the rapid expansion of wind power, traditional single-modality monitoring, such as vibration or airborne acoustic sensing, has revealed limitations in information completeness and resistance to interference. Consequently, multimodal fusion diagnosis has gained attention. Because most studies emphasize a single sensing modality and lack systematic reviews linking damage mechanisms, signal responses, and fusion strategies, this paper reviews acoustic-vibration fusion fault diagnosis for WTBs. Beginning with blade material and structural features, we characterize typical damage modes and their progression. We first review single-modality detection methods and highlight their limitations under complex operating conditions, establishing the case for multimodal fusion. We then systematically summarize signal-processing techniques, diagnostic models, and fusion strategies at data, feature, and decision levels. We compare approaches in terms of feature representation capacity, resistance to interference, and engineering applicability. Finally, in light of challenges in acquiring data in complex environments and the emerging role of digital-twin-based dynamic early warning, we outline promising directions for future research.
- Open Access
- 20 August 2026
- Published by Elsevier in SSRN Electronic Journal
Coordinated Energy Management with Dynamic Pricing Optimization for V2T-Enabled Urban Rail Transit with Station-Area EVs
To coordinate price-responsive electric vehicle (EV) mobility with the fast-varying power demand of urban rail transit (URT), this paper proposes a bi-level coordinated optimization method for a V2T-enabled URT-based microgrid integrated with a station-area EV charging station (EVCS). A coupled traffic-energy model is established by integrating the URT equivalent-circuit model with the travel, parking, charging, and discharging behaviors of residential, commercial, and station-native EVs. In the upper level, the station charging price is optimized at 30-min intervals. A price-elastic EV user-equilibrium model is established considering travel time, queueing time, driving energy, charging payment, V2T compensation, and battery degradation. The equilibrium problem is formulated as a variational inequality and converted into an equivalent convex optimization problem. The resulting EV flows are mapped to the time-varying charging and discharging capacities of the EVCS according to EV arrival times, parking durations, states of charge, and departure requirements. In the lower level, the ESS discharging-voltage threshold is optimized using the coordinated control strategy of the coupled URT system. Simulations based on the Merseyrail line show that the coordinated ESS–EVCS operation reduces the traction-substation peak power from 0.96 MW to 0.47 MW, corresponding to a reduction of 51.04%. Compared with the optimized fixed-price strategy, dynamic pricing increases the number of participating station-area EVs from 77 to 92 and reduces the URT operating cost from 95.179 GBP to 93.001 GBP. The results demonstrate that dynamic pricing can convert decentralized EV responses into effective flexibility for URT traction-power support while improving the economic performance of the coupled system.
- 20 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCoordinated Energy Management with Dynamic Pricing Optimization for V2T-Enabled Urban Rail Transit with Station-Area EVs
To coordinate price-responsive electric vehicle (EV) mobility with the fast-varying power demand of urban rail transit (URT), this paper proposes a bi-level coordinated optimization method for a V2T-enabled URT-based microgrid integrated with a station-area EV charging station (EVCS). A coupled traffic-energy model is established by integrating the URT equivalent-circuit model with the travel, parking, charging, and discharging behaviors of residential, commercial, and station-native EVs. In the upper level, the station charging price is optimized at 30-min intervals. A price-elastic EV user-equilibrium model is established considering travel time, queueing time, driving energy, charging payment, V2T compensation, and battery degradation. The equilibrium problem is formulated as a variational inequality and converted into an equivalent convex optimization problem. The resulting EV flows are mapped to the time-varying charging and discharging capacities of the EVCS according to EV arrival times, parking durations, states of charge, and departure requirements. In the lower level, the ESS discharging-voltage threshold is optimized using the coordinated control strategy of the coupled URT system. Simulations based on the Merseyrail line show that the coordinated ESS–EVCS operation reduces the traction-substation peak power from 0.96 MW to 0.47 MW, corresponding to a reduction of 51.04%. Compared with the optimized fixed-price strategy, dynamic pricing increases the number of participating station-area EVs from 77 to 92 and reduces the URT operating cost from 95.179 GBP to 93.001 GBP. The results demonstrate that dynamic pricing can convert decentralized EV responses into effective flexibility for URT traction-power support while improving the economic performance of the coupled system.
- Open Access
- 19 July 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (14) , 7387
An Ultra-Short-Term Wind Farm Power Forecasting Method Incorporating Spatial Features for Sustainable Energy Integration
Accurate wind power forecasting is imperative for ensuring grid stability and facilitating the large-scale integration of renewable energy—both central pillars of the global energy transition and the Dual Carbon strategic goals. However, existing methods often fail to fully capture the spatial heterogeneity and interdependencies among individual turbines, limiting their effectiveness for sustainable grid operation. To address this gap, this paper proposes an ultra-short-term wind power forecasting framework that incorporates explicit multi-dimensional spatial features. At the feature level, a 12-dimensional spatial feature system is constructed to quantify the microscale topology of wind farms. These static spatial attributes are seamlessly fused with dynamic temporal data using a dimensionality-balance factor strategy. Finally, a hybrid deep learning network comprising a multi-scale CNN, a multi-layer BiLSTM, and a multi-head self-attention mechanism is developed to capture complex spatiotemporal patterns. Experimental results on three real-world datasets show that the proposed method significantly outperforms baseline models, reducing the Mean Absolute Percentage Error by up to 11.09% and improving the coefficient of determination R2 up to 0.9120. By improving forecast accuracy and robustness, the method directly supports more reliable grid dispatching, reduces curtailment of wind energy, and thus contributes to the sustainable utilization of renewable resources. These findings demonstrate that incorporating explicit spatial correlation effectively enhances the accuracy and robustness of ultra-short-term wind power forecasting, providing robust decision support for power grid dispatching and advancing the sustainability of modern power systems.
- 19 July 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (14) , 7387
Open AccessAn Ultra-Short-Term Wind Farm Power Forecasting Method Incorporating Spatial Features for Sustainable Energy Integration
Accurate wind power forecasting is imperative for ensuring grid stability and facilitating the large-scale integration of renewable energy—both central pillars of the global energy transition and the Dual Carbon strategic goals. However, existing methods often fail to fully capture the spatial heterogeneity and interdependencies among individual turbines, limiting their effectiveness for sustainable grid operation. To address this gap, this paper proposes an ultra-short-term wind power forecasting framework that incorporates explicit multi-dimensional spatial features. At the feature level, a 12-dimensional spatial feature system is constructed to quantify the microscale topology of wind farms. These static spatial attributes are seamlessly fused with dynamic temporal data using a dimensionality-balance factor strategy. Finally, a hybrid deep learning network comprising a multi-scale CNN, a multi-layer BiLSTM, and a multi-head self-attention mechanism is developed to capture complex spatiotemporal patterns. Experimental results on three real-world datasets show that the proposed method significantly outperforms baseline models, reducing the Mean Absolute Percentage Error by up to 11.09% and improving the coefficient of determination R2 up to 0.9120. By improving forecast accuracy and robustness, the method directly supports more reliable grid dispatching, reduces curtailment of wind energy, and thus contributes to the sustainable utilization of renewable resources. These findings demonstrate that incorporating explicit spatial correlation effectively enhances the accuracy and robustness of ultra-short-term wind power forecasting, providing robust decision support for power grid dispatching and advancing the sustainability of modern power systems.
- Open Access
- 1 July 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (13) , 6657
Research on Strategies to Enhance the Resilience of Urban Power-Transportation Systems by Considering Mobile Energy Storage in Severe Sandstorm Environments
With the increasing frequency of extreme weather events, the vulnerability of urban power-transportation systems in severe dust storm conditions has become increasingly apparent. Addressing the shortcomings of existing research regarding the quantitative assessment and enhancement of system resilience, this paper proposes a set of strategies and methods for evaluating and improving the resilience of urban power-transportation systems under severe dust storm conditions, taking mobile energy storage into account. The study first establishes a multidimensional failure probability model for severe dust storm conditions: on the power grid side, it comprehensively considers fluctuations in renewable energy output, wind speed variations, and line insulation performance to propose a probabilistic failure model that accounts for the sand accumulation effect; on the transportation side, it considers road visibility and traffic flow to propose an improved BPR traffic flow model, using the Floyd algorithm to plan MES travel routes. Fault scenarios are generated using the Monte Carlo algorithm, and multidimensional system performance metrics for the power grid–road network-coupled nodes are established. A quantification method for resilience metrics applicable to urban power-transportation systems is proposed based on the ΦΛEΠ resilience index. Furthermore, a multi-objective, multi-stage resilience enhancement strategy for urban power-transportation systems that incorporates mobile energy storage is proposed using the NSGA-II algorithm. Finally, the effectiveness of the proposed optimization strategy was verified through coupled simulation cases using the IEEE-33 node test system and the Sioux Falls network. The results demonstrate that the proposed optimization strategy can significantly enhance system resilience under different optimization objectives.
- 1 July 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (13) , 6657
Open AccessResearch on Strategies to Enhance the Resilience of Urban Power-Transportation Systems by Considering Mobile Energy Storage in Severe Sandstorm Environments
With the increasing frequency of extreme weather events, the vulnerability of urban power-transportation systems in severe dust storm conditions has become increasingly apparent. Addressing the shortcomings of existing research regarding the quantitative assessment and enhancement of system resilience, this paper proposes a set of strategies and methods for evaluating and improving the resilience of urban power-transportation systems under severe dust storm conditions, taking mobile energy storage into account. The study first establishes a multidimensional failure probability model for severe dust storm conditions: on the power grid side, it comprehensively considers fluctuations in renewable energy output, wind speed variations, and line insulation performance to propose a probabilistic failure model that accounts for the sand accumulation effect; on the transportation side, it considers road visibility and traffic flow to propose an improved BPR traffic flow model, using the Floyd algorithm to plan MES travel routes. Fault scenarios are generated using the Monte Carlo algorithm, and multidimensional system performance metrics for the power grid–road network-coupled nodes are established. A quantification method for resilience metrics applicable to urban power-transportation systems is proposed based on the ΦΛEΠ resilience index. Furthermore, a multi-objective, multi-stage resilience enhancement strategy for urban power-transportation systems that incorporates mobile energy storage is proposed using the NSGA-II algorithm. Finally, the effectiveness of the proposed optimization strategy was verified through coupled simulation cases using the IEEE-33 node test system and the Sioux Falls network. The results demonstrate that the proposed optimization strategy can significantly enhance system resilience under different optimization objectives.
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Intelligent Transportation Systems
- Vol. 27 (7) , 7666-7680
CADNM: A Chain Active Distribution Network With Soft Open Points for Optimal Power Schedule of Expressway Considering Multi-Uncertainties
To address the challenges of limited resilience and high operational costs in current expressway power supply systems under extreme conditions, a chain active distributed network model featuring dynamic SOPs is introduced. This model leverages flexible interactions among network nodes to facilitate optimal power flow distribution and energy dispatch. An uncertain dataset, based on the Wasserstein distance, is constructed to account for the diverse characteristics of power sources and loads on expressways. Using this dataset, a “Traffic-Electrical” coupling model for typical power scenarios is developed to identify the optimal SOP installation locations under improved flow capturing location model constraints, thus forming an active network with SOPs. A two-stage optimization model targeting both the “robustness” and “economy” of the power supply system is designed with the support of a novel “NSGA-II-PSO” heuristic algorithm. Simulations of the “Taohuaping-Dingyuan” segment of the G30 “Lian-Huo Expressway” demonstrate the model’s effectiveness, with a 9.74% reduction in average voltage offset and a 3.78% decrease in dispatch costs compared to traditional networks, confirming its robustness, flexibility, and cost-effectiveness.
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Intelligent Transportation Systems
- Vol. 27 (7) , 7666-7680
CADNM: A Chain Active Distribution Network With Soft Open Points for Optimal Power Schedule of Expressway Considering Multi-Uncertainties
To address the challenges of limited resilience and high operational costs in current expressway power supply systems under extreme conditions, a chain active distributed network model featuring dynamic SOPs is introduced. This model leverages flexible interactions among network nodes to facilitate optimal power flow distribution and energy dispatch. An uncertain dataset, based on the Wasserstein distance, is constructed to account for the diverse characteristics of power sources and loads on expressways. Using this dataset, a “Traffic-Electrical” coupling model for typical power scenarios is developed to identify the optimal SOP installation locations under improved flow capturing location model constraints, thus forming an active network with SOPs. A two-stage optimization model targeting both the “robustness” and “economy” of the power supply system is designed with the support of a novel “NSGA-II-PSO” heuristic algorithm. Simulations of the “Taohuaping-Dingyuan” segment of the G30 “Lian-Huo Expressway” demonstrate the model’s effectiveness, with a 9.74% reduction in average voltage offset and a 3.78% decrease in dispatch costs compared to traditional networks, confirming its robustness, flexibility, and cost-effectiveness.
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-16
Measurement of Interface Pressure Distortion and Flashover Behavior in Cable Terminal Layers Under Thermomechanical Stress
Cable composite insulation interfaces are susceptible to pressure distribution distortion under combined electric, thermal, and mechanical stresses, potentially triggering insulation failure. To investigate this phenomenon, this research develops a comprehensive three-stage approach. Initially, a bilateral shaft-sleeve contact model is established to theoretically analyze the mechanism of uneven interfacial pressure distribution under bending stress and temperature at cable terminal interfaces. Subsequently, a specialized bending-temperature coupling experimental platform validates the theoretical findings, confirming that extreme temperatures and bending stresses significantly distort interfacial pressure. Finally, surface flashover discharge experiments on XLPE-SiR interfaces are conducted, examining discharge characteristics through multiple parameters including starting discharge voltage, grey scale histograms, and infrared spectra. The results reveal that mechanical-thermal stress coupling alters the interference fit of cable composite interfaces, leading to non-uniform pressure distribution. Furthermore, the study demonstrates that pressure distribution transition modes directly influence discharge path characteristics. The extent of discharge damage is found to correlate with the combined effects of discharge channel broadening at initiation sites and dielectric polarization. These findings provide crucial insights for improving cable terminal design and reliability in high-voltage power systems.
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-16
Measurement of Interface Pressure Distortion and Flashover Behavior in Cable Terminal Layers Under Thermomechanical Stress
Cable composite insulation interfaces are susceptible to pressure distribution distortion under combined electric, thermal, and mechanical stresses, potentially triggering insulation failure. To investigate this phenomenon, this research develops a comprehensive three-stage approach. Initially, a bilateral shaft-sleeve contact model is established to theoretically analyze the mechanism of uneven interfacial pressure distribution under bending stress and temperature at cable terminal interfaces. Subsequently, a specialized bending-temperature coupling experimental platform validates the theoretical findings, confirming that extreme temperatures and bending stresses significantly distort interfacial pressure. Finally, surface flashover discharge experiments on XLPE-SiR interfaces are conducted, examining discharge characteristics through multiple parameters including starting discharge voltage, grey scale histograms, and infrared spectra. The results reveal that mechanical-thermal stress coupling alters the interference fit of cable composite interfaces, leading to non-uniform pressure distribution. Furthermore, the study demonstrates that pressure distribution transition modes directly influence discharge path characteristics. The extent of discharge damage is found to correlate with the combined effects of discharge channel broadening at initiation sites and dielectric polarization. These findings provide crucial insights for improving cable terminal design and reliability in high-voltage power systems.
- Open Access
- 28 January 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (2) , 385-398
Dynamic Bayesian Network for Continuous Health Index Estimation and Condition Assessment of Power Transformers
To address the limitations of traditional transformer health index (HI), such as high dependence on data integrity and inability to assist in diagnosing latent faults, this study proposes an HI prediction method based on dynamic Bayesian network (DBN). The method first constructs a DBN for characterising the health state indicator system of power transformers according to their structural composition and operational environmental conditions. Next, the entropy weight method and fuzzy membership function are employed to determine the prior probability tables between DBN nodes, whereas the logistic regression method is used to establish conditional probability tables. Finally, existing literature data and field measurement data are utilised to validate the proposed method. The results demonstrate that: (1) the developed DBN can not only effectively calculate the current HI of transformers but also predict HI values for different future time intervals and (2) it can evaluate the overall health state of transformers and identify potential faults in individual components based on node‐specific HI values. Therefore, this method provides valuable support for operation and maintenance personnel in making informed decisions regarding maintenance strategies, batch retirement and replacement plans.
- 28 January 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 11 (2) , 385-398
Open AccessDynamic Bayesian Network for Continuous Health Index Estimation and Condition Assessment of Power Transformers
To address the limitations of traditional transformer health index (HI), such as high dependence on data integrity and inability to assist in diagnosing latent faults, this study proposes an HI prediction method based on dynamic Bayesian network (DBN). The method first constructs a DBN for characterising the health state indicator system of power transformers according to their structural composition and operational environmental conditions. Next, the entropy weight method and fuzzy membership function are employed to determine the prior probability tables between DBN nodes, whereas the logistic regression method is used to establish conditional probability tables. Finally, existing literature data and field measurement data are utilised to validate the proposed method. The results demonstrate that: (1) the developed DBN can not only effectively calculate the current HI of transformers but also predict HI values for different future time intervals and (2) it can evaluate the overall health state of transformers and identify potential faults in individual components based on node‐specific HI values. Therefore, this method provides valuable support for operation and maintenance personnel in making informed decisions regarding maintenance strategies, batch retirement and replacement plans.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1519-1528
Impact of Accelerated Shock on Partial Discharge Characteristics at the Oil-Paper Insulation Interface of Transformers
The variation in pressure distribution at the oil-paper insulation interface of transformers under shock conditions leads to an enhancement of partial discharge, posing severe challenges to the reliability of transformer oil-paper insulation. In this study, an experimental platform for partial discharge testing at the oil-paper insulation interface under accelerated shock is established to investigate the partial discharge characteristics at different acceleration levels. The experimental results reveal that, compared to the zero-acceleration condition, accelerated shock significantly intensifies partial discharge at the oil-paper interface. With an acceleration of 10 m/s², the average discharge magnitude for the wire-plate electrode increases by 43.2%, while that for the needle-plate electrode increases by 20.0%. Both partial discharge magnitude and discharge frequency are observed to increase markedly with increasing acceleration. Furthermore, based on Comsol Multiphysics, a fluid-structure interaction model of the oil-paper insulation under accelerated shock is constructed. The simulation results indicate that accelerated shock induces fluctuations in the pressure distribution at the oil-paper interface, which alters the microbubble layer formation process and changes the number density of gas molecules at the interface. When the acceleration direction is negative, the pressure of the microbubble layer decreases, the solubility of gas reduces, and the bubble volume expands, resulting in an increased average free path of electrons and thus enhanced partial discharge. During cyclic positive and negative acceleration shocks, negative-direction acceleration is found to play a dominant role in promoting partial discharge at the oil-paper interface, thereby further aggravating the partial discharge process. This study can provide a reference for insulation design and protection of transformers under impact conditions.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1519-1528
Impact of Accelerated Shock on Partial Discharge Characteristics at the Oil-Paper Insulation Interface of Transformers
The variation in pressure distribution at the oil-paper insulation interface of transformers under shock conditions leads to an enhancement of partial discharge, posing severe challenges to the reliability of transformer oil-paper insulation. In this study, an experimental platform for partial discharge testing at the oil-paper insulation interface under accelerated shock is established to investigate the partial discharge characteristics at different acceleration levels. The experimental results reveal that, compared to the zero-acceleration condition, accelerated shock significantly intensifies partial discharge at the oil-paper interface. With an acceleration of 10 m/s², the average discharge magnitude for the wire-plate electrode increases by 43.2%, while that for the needle-plate electrode increases by 20.0%. Both partial discharge magnitude and discharge frequency are observed to increase markedly with increasing acceleration. Furthermore, based on Comsol Multiphysics, a fluid-structure interaction model of the oil-paper insulation under accelerated shock is constructed. The simulation results indicate that accelerated shock induces fluctuations in the pressure distribution at the oil-paper interface, which alters the microbubble layer formation process and changes the number density of gas molecules at the interface. When the acceleration direction is negative, the pressure of the microbubble layer decreases, the solubility of gas reduces, and the bubble volume expands, resulting in an increased average free path of electrons and thus enhanced partial discharge. During cyclic positive and negative acceleration shocks, negative-direction acceleration is found to play a dominant role in promoting partial discharge at the oil-paper interface, thereby further aggravating the partial discharge process. This study can provide a reference for insulation design and protection of transformers under impact conditions.
- Open Access
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 160707-160721
Deep Learning-Based Predictive Control of Vehicle-to-Grid Onboard Charger Back Stage Models
To address the insufficient modeling accuracy and slow dynamic response of the Capacitor-Inductor-Inductor-Capacitor (CLLC) resonant converter in Vehicle-to-Grid (V2G) automotive onboard charger, a deep learning-based model predictive control method for the post-stage V2G onboard charger is proposed. This approach utilizes deep learning techniques to perform steady-state implicit modeling of the CLLC resonant converter, enabling accurate calculation of voltage gain across a diverse array of switching frequencies and varying load conditions. Based on this model, a deep learning model predictive control (DL-MPC) strategy is developed. The DL-MPC method leverages deep learning-based voltage gain predictions for direct multi-step control sequence prediction. Simulations demonstrate that the proposed DL-MPC strategy outperforms conventional proportional-integral (PI) and model predictive control (MPC) control, effectively suppressing voltage overshoot and undershoot, achieving reductions of up to 60.9%, and reducing recovery time by up to 55.6% under load transients and reference voltage step changes, thereby enhancing dynamic response and stability. Experimental validation that DL-MPC achieves a 65.21% reduction in voltage dips and a 31.25% faster recovery time compared to PI control under load transients. Simulation and experimental results consistently show that the deep-learning-based modeling attains high fidelity, while the proposed DL-MPC strategy delivers superior control performance for the CLLC resonant converter, yielding a markedly improved dynamic response.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 160707-160721
Open AccessDeep Learning-Based Predictive Control of Vehicle-to-Grid Onboard Charger Back Stage Models
To address the insufficient modeling accuracy and slow dynamic response of the Capacitor-Inductor-Inductor-Capacitor (CLLC) resonant converter in Vehicle-to-Grid (V2G) automotive onboard charger, a deep learning-based model predictive control method for the post-stage V2G onboard charger is proposed. This approach utilizes deep learning techniques to perform steady-state implicit modeling of the CLLC resonant converter, enabling accurate calculation of voltage gain across a diverse array of switching frequencies and varying load conditions. Based on this model, a deep learning model predictive control (DL-MPC) strategy is developed. The DL-MPC method leverages deep learning-based voltage gain predictions for direct multi-step control sequence prediction. Simulations demonstrate that the proposed DL-MPC strategy outperforms conventional proportional-integral (PI) and model predictive control (MPC) control, effectively suppressing voltage overshoot and undershoot, achieving reductions of up to 60.9%, and reducing recovery time by up to 55.6% under load transients and reference voltage step changes, thereby enhancing dynamic response and stability. Experimental validation that DL-MPC achieves a 65.21% reduction in voltage dips and a 31.25% faster recovery time compared to PI control under load transients. Simulation and experimental results consistently show that the deep-learning-based modeling attains high fidelity, while the proposed DL-MPC strategy delivers superior control performance for the CLLC resonant converter, yielding a markedly improved dynamic response.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
Fluid–plasma bidirectional coupling: An experimental analysis of the reverse influence of fluid flow on plasma discharge
Surface dielectric barrier discharge (SDBD) plasma aerodynamic actuation flow control technology has broad potential to improve the aerodynamic performance of aircraft. The essence of the flow control mechanism is the bidirectional dynamic interaction between fluid and plasma. At present, plasma flow control research mainly focuses on the unidirectional disturbance of the flow field by plasma aerodynamic excitation, and the reverse influence of the fluid flow on the gas discharge plasma process has been considered less. Therefore, this paper builds an SDBD actuator discharge test platform in a low-speed wind tunnel to explore the influence of the fluid flow rate on the discharge characteristics of the SDBD plasma actuator. The experimental results show that with the increase in airflow velocity, the distribution area of the SDBD plasma shows a trend of spanwise elongation and transverse broadening. At the same time, the discharge current amplitude decreases, and the discharge frequency increases greatly. Compared with non-airflow conditions, in a 40 m/s airflow environment, the plasma distribution length increases by 130.8%, the width increases by 74.0%, and the discharge frequency increases by 666.7%. These experimental results rigorously validate the significant reverse effect of airflow on the plasma discharge process, while clearly revealing the bidirectional dynamic interaction between plasma excitation processes and fluid dynamics. This discovery highlights the necessity of reassessing plasma flow control strategies across different flow conditions, providing crucial guidance for optimizing plasma actuator design and formulating flow control strategies.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
Fluid–plasma bidirectional coupling: An experimental analysis of the reverse influence of fluid flow on plasma discharge
Surface dielectric barrier discharge (SDBD) plasma aerodynamic actuation flow control technology has broad potential to improve the aerodynamic performance of aircraft. The essence of the flow control mechanism is the bidirectional dynamic interaction between fluid and plasma. At present, plasma flow control research mainly focuses on the unidirectional disturbance of the flow field by plasma aerodynamic excitation, and the reverse influence of the fluid flow on the gas discharge plasma process has been considered less. Therefore, this paper builds an SDBD actuator discharge test platform in a low-speed wind tunnel to explore the influence of the fluid flow rate on the discharge characteristics of the SDBD plasma actuator. The experimental results show that with the increase in airflow velocity, the distribution area of the SDBD plasma shows a trend of spanwise elongation and transverse broadening. At the same time, the discharge current amplitude decreases, and the discharge frequency increases greatly. Compared with non-airflow conditions, in a 40 m/s airflow environment, the plasma distribution length increases by 130.8%, the width increases by 74.0%, and the discharge frequency increases by 666.7%. These experimental results rigorously validate the significant reverse effect of airflow on the plasma discharge process, while clearly revealing the bidirectional dynamic interaction between plasma excitation processes and fluid dynamics. This discovery highlights the necessity of reassessing plasma flow control strategies across different flow conditions, providing crucial guidance for optimizing plasma actuator design and formulating flow control strategies.