Binglei Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Binglei Cao has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Guangning Wu
Southwest Jiaotong University
12 shared publications - Kai Liu
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
11 shared publications - Kui Chen
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
5 shared publications - Yongqiang Kang
School of New Energy and Power Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China
5 shared publications - Guoqiang Gao
School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China
4 shared publications - Shuaibing Li
School of New Energy and Power Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China
4 shared publications
Latest Publications
- 20 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Physics-Informed Hypergraph-Augmented Discharge Recognition for Improved Insulation Diagnosis of Vehicle Cable Terminals
Interfacial discharge constitutes one of the most detrimental factors in multilayer composite insulation, severely accelerating aging, causing unexpected failures, and potentially triggering catastrophic accidents. To address challenges in temporal feature extraction, noise sensitivity, and limited labeled samples for interfacial discharge detection, this study proposes a physics-informed hypergraph enhancement and recognition framework. First, we develop a physics-informed hypergraph-guided denoising diffusion implicit model (PIH-DDIM) to mitigate noise interference inherent in data-driven approaches, enabling high-fidelity data augmentation. Subsequently, the HyperSwin multiscale recognition network is designed. Specifically, a hierarchical hypergraph patch merging mechanism is incorporated to reduce feature resolution while expanding receptive fields progressively. Window-based hypergraph multi-head attention is constructed to facilitate cross-region information interaction. Furthermore, masked hypergraph modeling (MHM) self-supervised pretraining is introduced to autonomously learn intrinsic hypergraph associations and topology, effectively overcoming label scarcity and poor model generalizability. Experiments demonstrate a discharge recognition accuracy of 96.32% on real-world EMU cable terminal datasets—a 2.49 percentage-point improvement over baseline methods.
- 20 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Physics-Informed Hypergraph-Augmented Discharge Recognition for Improved Insulation Diagnosis of Vehicle Cable Terminals
Interfacial discharge constitutes one of the most detrimental factors in multilayer composite insulation, severely accelerating aging, causing unexpected failures, and potentially triggering catastrophic accidents. To address challenges in temporal feature extraction, noise sensitivity, and limited labeled samples for interfacial discharge detection, this study proposes a physics-informed hypergraph enhancement and recognition framework. First, we develop a physics-informed hypergraph-guided denoising diffusion implicit model (PIH-DDIM) to mitigate noise interference inherent in data-driven approaches, enabling high-fidelity data augmentation. Subsequently, the HyperSwin multiscale recognition network is designed. Specifically, a hierarchical hypergraph patch merging mechanism is incorporated to reduce feature resolution while expanding receptive fields progressively. Window-based hypergraph multi-head attention is constructed to facilitate cross-region information interaction. Furthermore, masked hypergraph modeling (MHM) self-supervised pretraining is introduced to autonomously learn intrinsic hypergraph associations and topology, effectively overcoming label scarcity and poor model generalizability. Experiments demonstrate a discharge recognition accuracy of 96.32% on real-world EMU cable terminal datasets—a 2.49 percentage-point improvement over baseline methods.
- 6 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Insulation Condition Recognition of Cable Terminals for High-Speed Trains Using Multi-Dimensional Image Modeling and SwinCNNFusion
Accurately assessing the severity of cable terminal defects is crucial for ensuring the stable operation of high-speed trains. However, the partial discharge (PD) characteristics of the same type of defect show a high degree of similarity in different severity levels, which brings difficulties to the accurate identification of insulation defects. To address this issue, this paper proposes a new method for defect detection and severity identification. Firstly, the original PD signal is converted into an image by using Multi-scale Differential Synchro-squeezing Transformation (MDSST) and Dynamic Phase Coupling Matrix (DPCM). Then, the SwinCNNFusion model - a parallel fusion model integrating the Swin Transformer and the Convolutional Neural Network (CNN)- is used for classification. This PD signal processing technology simultaneously embeds the time-frequency information and phase information of different orders of differences of the original PD signal into the generated image. This reduces the similarity between classes and significantly improves the distinguishability of the transformed representation. Meanwhile, the SwinCNNFusion model is designed to accurately identify and integrate the multi-dimensional modeling information derived from PD signals. The experimental results show that the detection accuracy of this method is 96.78%, which is superior to several existing methods.
- 6 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Insulation Condition Recognition of Cable Terminals for High-Speed Trains Using Multi-Dimensional Image Modeling and SwinCNNFusion
Accurately assessing the severity of cable terminal defects is crucial for ensuring the stable operation of high-speed trains. However, the partial discharge (PD) characteristics of the same type of defect show a high degree of similarity in different severity levels, which brings difficulties to the accurate identification of insulation defects. To address this issue, this paper proposes a new method for defect detection and severity identification. Firstly, the original PD signal is converted into an image by using Multi-scale Differential Synchro-squeezing Transformation (MDSST) and Dynamic Phase Coupling Matrix (DPCM). Then, the SwinCNNFusion model - a parallel fusion model integrating the Swin Transformer and the Convolutional Neural Network (CNN)- is used for classification. This PD signal processing technology simultaneously embeds the time-frequency information and phase information of different orders of differences of the original PD signal into the generated image. This reduces the similarity between classes and significantly improves the distinguishability of the transformed representation. Meanwhile, the SwinCNNFusion model is designed to accurately identify and integrate the multi-dimensional modeling information derived from PD signals. The experimental results show that the detection accuracy of this method is 96.78%, which is superior to several existing methods.
- 26 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Contact Performance of Strap Contacts in HVDC Converter Transformer Valve-Side Bushings: A Review
In High Voltage and Ultra High Voltage power systems, the valve side bushing of converter transformer serves as a critical component connecting the transformer to the converter valve, with its operational reliability directly impacts the stability of the entire power system. The bushing endures prolonged exposure to high voltage, large current, and high-order harmonics during operation, leading to frequent failures. particularly defects in strap contacts constitute a predominant cause of valve side bushing failures. As an essential electrical connection structure within bushing, the contact performance of strap contacts is intrinsically linked to bushing stability. This review synthesizes recent advancements in Multiphysics coupling simulations, electrical contact performance analysis, and corrosion failure mechanisms related to strap contacts. Ultimately, valuable future research directions for strap contacts are summarized, providing technical support for the insulation design of valve side bushing in high voltage direct current (HVDC) projects.
- 26 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Contact Performance of Strap Contacts in HVDC Converter Transformer Valve-Side Bushings: A Review
In High Voltage and Ultra High Voltage power systems, the valve side bushing of converter transformer serves as a critical component connecting the transformer to the converter valve, with its operational reliability directly impacts the stability of the entire power system. The bushing endures prolonged exposure to high voltage, large current, and high-order harmonics during operation, leading to frequent failures. particularly defects in strap contacts constitute a predominant cause of valve side bushing failures. As an essential electrical connection structure within bushing, the contact performance of strap contacts is intrinsically linked to bushing stability. This review synthesizes recent advancements in Multiphysics coupling simulations, electrical contact performance analysis, and corrosion failure mechanisms related to strap contacts. Ultimately, valuable future research directions for strap contacts are summarized, providing technical support for the insulation design of valve side bushing in high voltage direct current (HVDC) projects.
- Open Access
- 23 November 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (6) , 1474-1485
Novel Inverter‐Fed Motor Drive System With Common‐Mode Voltage Suppression and End‐Surge Slew Rate Suppression Function
Electric locomotives on the horizon will integrate SiC inverters, promising quicker switching and lower losses than traditional setups. However, in addition to the steep rising edge, the inverter‐fed motor drive system faces challenges such as high common‐mode voltage (CMV) and high motor terminal surge voltage swing rate (d v /d t ). To tackle these hurdles, this paper proposes a novel tailored traction control system for three‐phase locomotive motors. This innovative strategy utilises near‐state space vector pulse width modulation (NSVPWM), selectively removing space vectors with high CMV to generate modulation signals. Complemented by a slew rate capacitor configuration, the aim is to reduce CMV while effectively suppressing motor‐side voltage slew rate. To validate this approach, experimental waveforms from on‐site inverter‐fed motor drive systems have been analysed to derive high‐frequency parameters of long‐line cables and variable frequency motors to mimic real locomotive operating conditions better. Through experimental research and comparative simulations against traditional methods, this study reveals a significant 33.3% reduction in CMV compared to traditional systems. Furthermore, it achieves an impressive decrease in the rise/fall slope, down to 86.6%, while ensuring nearly zero electrical power consumption.
- 23 November 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (6) , 1474-1485
Open AccessNovel Inverter‐Fed Motor Drive System With Common‐Mode Voltage Suppression and End‐Surge Slew Rate Suppression Function
Electric locomotives on the horizon will integrate SiC inverters, promising quicker switching and lower losses than traditional setups. However, in addition to the steep rising edge, the inverter‐fed motor drive system faces challenges such as high common‐mode voltage (CMV) and high motor terminal surge voltage swing rate (d v /d t ). To tackle these hurdles, this paper proposes a novel tailored traction control system for three‐phase locomotive motors. This innovative strategy utilises near‐state space vector pulse width modulation (NSVPWM), selectively removing space vectors with high CMV to generate modulation signals. Complemented by a slew rate capacitor configuration, the aim is to reduce CMV while effectively suppressing motor‐side voltage slew rate. To validate this approach, experimental waveforms from on‐site inverter‐fed motor drive systems have been analysed to derive high‐frequency parameters of long‐line cables and variable frequency motors to mimic real locomotive operating conditions better. Through experimental research and comparative simulations against traditional methods, this study reveals a significant 33.3% reduction in CMV compared to traditional systems. Furthermore, it achieves an impressive decrease in the rise/fall slope, down to 86.6%, while ensuring nearly zero electrical power consumption.
- Top Cited Papers
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (12) , 9330-9340
A Self-Supervised Evaluation Approach of Insulation Condition for Vehicle Cable Terminals Using Hypergraph Neural Network With Dynamic Features
High-speed electric multiple units (EMUs) play a pivotal role as the vital arteries of the national economy, essential components of major public infrastructure projects, and the fundamental backbone of a nation’s comprehensive transportation network. Current detection methodologies struggle to achieve effective online monitoring of cable terminal insulation due to challenges in extracting dynamic temporal signal features and insufficient annotated datasets for pattern recognition. A self-supervised evaluation method of insulation state for vehicle cable terminals based on the hypergraph neural network with dynamic features is proposed in this article. Initially, a novel method for constructing a graph structure with spectral differentiation is introduced to characterize the dynamic features and deterioration trends of the insulation state in vehicle cable terminals. Subsequently, to address the general problem of limited labels on-site, the defined hypergraph neural network is embedded to get the self-supervised hypergraph neural network. Furthermore, the fine-tuned hypergraph model is initialized with partial parameters derived from the embedded self-supervised pretrained model. Ultimately, the proposed approach is experimentally verified by vehicle cable terminal HFCT experiments. The proposed method demonstrates robust feature representation and generalization capabilities for assessing the insulation of vehicle cable terminals. It achieves an accuracy of up to 99.01%, providing a reliable framework for intelligent fault diagnosis in high-speed EMU traction power supply systems and industrial predictive maintenance.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (12) , 9330-9340
Top Cited PapersA Self-Supervised Evaluation Approach of Insulation Condition for Vehicle Cable Terminals Using Hypergraph Neural Network With Dynamic Features
High-speed electric multiple units (EMUs) play a pivotal role as the vital arteries of the national economy, essential components of major public infrastructure projects, and the fundamental backbone of a nation’s comprehensive transportation network. Current detection methodologies struggle to achieve effective online monitoring of cable terminal insulation due to challenges in extracting dynamic temporal signal features and insufficient annotated datasets for pattern recognition. A self-supervised evaluation method of insulation state for vehicle cable terminals based on the hypergraph neural network with dynamic features is proposed in this article. Initially, a novel method for constructing a graph structure with spectral differentiation is introduced to characterize the dynamic features and deterioration trends of the insulation state in vehicle cable terminals. Subsequently, to address the general problem of limited labels on-site, the defined hypergraph neural network is embedded to get the self-supervised hypergraph neural network. Furthermore, the fine-tuned hypergraph model is initialized with partial parameters derived from the embedded self-supervised pretrained model. Ultimately, the proposed approach is experimentally verified by vehicle cable terminal HFCT experiments. The proposed method demonstrates robust feature representation and generalization capabilities for assessing the insulation of vehicle cable terminals. It achieves an accuracy of up to 99.01%, providing a reliable framework for intelligent fault diagnosis in high-speed EMU traction power supply systems and industrial predictive maintenance.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (5) , 11088-11099
Peak-Hold-Aided Evaluation Approach for the Insulation State of Vehicle Cable Terminals via Adaptive Spatial–Temporal Graph-Gated Attention Networks
Existing assessment methods for vehicle cable terminals suffer from accuracy degradation due to insufficient ability to extract spatial and temporal features, and inability to be installed on resource-constrained high-speed electric multiple units (high-speed EMUs) due to huge parameters of the neural network model. A peak-hold-aided evaluation approach to acquire the insulation state of vehicle cable terminals via an adaptive spatial-temporal graph-gated attention network (AdaSTGGAT) is proposed in this article. Initially, an approach for the construction of temporal graph structures based on peak hold and Jensen-Shannon divergence is proposed to address the issues of large amounts of data and the difficulty of analyzing graph structures. The graph-gated attention block is subsequently introduced for feature extraction to extract the spatial-temporal features of the signal accurately. Furthermore, AdaSTGGAT is designed as the backbone for feature extraction and aggregation. Specifically, the supervision mechanism is introduced to stabilize the training process, which enables the model to be pruned. Ultimately, the proposed approach is experimentally validated via high-frequency current transformer (HFCT) experiments on vehicle cable terminals. The proposed methodology demonstrates robust spatial-temporal feature representation capabilities for insulation condition assessment for vehicle cable terminals, achieving average performance metrics of 97.40% accuracy, 97.50% precision, 97.40% recall, 97.40% $F1$ -score, and 96.90% Kappa coefficient. Notably, the architecture incorporates a data-driven dynamic pruning mechanism that optimizes model complexity while maintaining diagnostic reliability, thereby advancing the practical implementation of online insulation monitoring systems in industrial applications.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (5) , 11088-11099
Peak-Hold-Aided Evaluation Approach for the Insulation State of Vehicle Cable Terminals via Adaptive Spatial–Temporal Graph-Gated Attention Networks
Existing assessment methods for vehicle cable terminals suffer from accuracy degradation due to insufficient ability to extract spatial and temporal features, and inability to be installed on resource-constrained high-speed electric multiple units (high-speed EMUs) due to huge parameters of the neural network model. A peak-hold-aided evaluation approach to acquire the insulation state of vehicle cable terminals via an adaptive spatial-temporal graph-gated attention network (AdaSTGGAT) is proposed in this article. Initially, an approach for the construction of temporal graph structures based on peak hold and Jensen-Shannon divergence is proposed to address the issues of large amounts of data and the difficulty of analyzing graph structures. The graph-gated attention block is subsequently introduced for feature extraction to extract the spatial-temporal features of the signal accurately. Furthermore, AdaSTGGAT is designed as the backbone for feature extraction and aggregation. Specifically, the supervision mechanism is introduced to stabilize the training process, which enables the model to be pruned. Ultimately, the proposed approach is experimentally validated via high-frequency current transformer (HFCT) experiments on vehicle cable terminals. The proposed methodology demonstrates robust spatial-temporal feature representation capabilities for insulation condition assessment for vehicle cable terminals, achieving average performance metrics of 97.40% accuracy, 97.50% precision, 97.40% recall, 97.40% $F1$ -score, and 96.90% Kappa coefficient. Notably, the architecture incorporates a data-driven dynamic pruning mechanism that optimizes model complexity while maintaining diagnostic reliability, thereby advancing the practical implementation of online insulation monitoring systems in industrial applications.
- 31 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1639-1652
A Review and Progress of Insulation Fault Diagnosis for Cable Using Partial Discharge Approach
The cable is an essential pivot of electric energy transmission, and its operational condition influences the safety and stability of both the power system (PS) and traction power supply system (TPSS). The prompt detection of cable insulation condition by partial discharge monitoring is crucial for mitigating potential damage to the cables. To begin with, this article provides a comprehensive overview of partial discharge detection approaches for cables by introducing the mechanism of partial discharge in cables. The detection approaches are categorized into electrical detection techniques and non-electrical detection techniques. Afterwards, to accurately assess the insulation condition of cables using the partial discharge detection method, this article summarizes the insulation defect diagnosis approaches for cables. In particular, the insulation defect diagnosis approaches primarily comprise extraction and optimization for features, traditional machine-learning-based fault diagnosis approaches, and deep-learning-based fault diagnosis approaches. To conclude, this article summarizes the challenges and future research directions of cable fault diagnosis. Accurate cable fault diagnosis is fundamental to maintaining the reliable operation of cables, ensuring an uninterrupted power supply to both PS and TPSS, and enhancing the responsiveness to equipment failures.
- 31 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1639-1652
A Review and Progress of Insulation Fault Diagnosis for Cable Using Partial Discharge Approach
The cable is an essential pivot of electric energy transmission, and its operational condition influences the safety and stability of both the power system (PS) and traction power supply system (TPSS). The prompt detection of cable insulation condition by partial discharge monitoring is crucial for mitigating potential damage to the cables. To begin with, this article provides a comprehensive overview of partial discharge detection approaches for cables by introducing the mechanism of partial discharge in cables. The detection approaches are categorized into electrical detection techniques and non-electrical detection techniques. Afterwards, to accurately assess the insulation condition of cables using the partial discharge detection method, this article summarizes the insulation defect diagnosis approaches for cables. In particular, the insulation defect diagnosis approaches primarily comprise extraction and optimization for features, traditional machine-learning-based fault diagnosis approaches, and deep-learning-based fault diagnosis approaches. To conclude, this article summarizes the challenges and future research directions of cable fault diagnosis. Accurate cable fault diagnosis is fundamental to maintaining the reliable operation of cables, ensuring an uninterrupted power supply to both PS and TPSS, and enhancing the responsiveness to equipment failures.