Takanori Arimoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takanori Arimoto has a total of 248 co-authors. Here are the top co-authors by number of shared publications:
Daisuke Kutsuzawa
17 shared publicationsMasafumi Watanabe
17 shared publicationsHiroki Takahashi
Department of Cardiology, Yabuki Hospital, Yamagata, Japan
16 shared publicationsIsao Kubota
Department of Cardiology, Pulmonology, and Nephrology Yamagata University School of Medicine Yamagata Japan
16 shared publicationsNaoaki Hashimoto
Department of Cardiology, Pulmonology, and Nephrology, Yamagata University School of Medicine , 2-2-2 Iida-Nishi, Yamagata 990-9585
16 shared publicationsTetsu Watanabe
16 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (10) , ytag749
Conservative management of a dislodged leadless pacemaker wedged in the pulmonary artery assessed by pulmonary perfusion scintigraphy: a case report
Background: Leadless pacemakers reduce complications associated with conventional transvenous systems; however, device dislodgement with pulmonary artery embolization is a rare complication unique to leadless pacemakers. Although prompt retrieval is generally recommended, retrieval from the pulmonary artery may carry procedural risks, particularly in elderly or high-risk patients. Case summary: An 84-year-old woman with complete atrioventricular block underwent implantation of a leadless pacemaker. Although the pacing threshold was favourable, the R-wave amplitude was low, and unstable device movement was observed after tether release, suggesting inadequate fixation. Two hours after implantation, pacing failure occurred, and chest radiography showed migration of the device into the right pulmonary artery. The following day, the device migrated to the left posterior basal segmental pulmonary artery and remained stably wedged. Because of the risk associated with retrieval, conservative management was selected, and a transvenous pacemaker was implanted. Serial lung perfusion scintigraphy demonstrated right-to-left perfusion distributions of 60.5% vs. 39.5% at 10 days, 59.1% vs. 40.9% at 3 months, and 58.5% vs. 41.5% at 1 year, without progressive deterioration in left lung volume. The patient remained asymptomatic over 3 years of follow-up. Discussion: This case illustrates that conservative management may be feasible in carefully selected high-risk patients when an embolized leadless pacemaker is stably wedged within the pulmonary artery. Serial pulmonary perfusion scintigraphy may provide objective evidence of preserved pulmonary perfusion and support long-term follow-up after conservative management.
- 30 September 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (10) , ytag749
Open AccessConservative management of a dislodged leadless pacemaker wedged in the pulmonary artery assessed by pulmonary perfusion scintigraphy: a case report
Background: Leadless pacemakers reduce complications associated with conventional transvenous systems; however, device dislodgement with pulmonary artery embolization is a rare complication unique to leadless pacemakers. Although prompt retrieval is generally recommended, retrieval from the pulmonary artery may carry procedural risks, particularly in elderly or high-risk patients. Case summary: An 84-year-old woman with complete atrioventricular block underwent implantation of a leadless pacemaker. Although the pacing threshold was favourable, the R-wave amplitude was low, and unstable device movement was observed after tether release, suggesting inadequate fixation. Two hours after implantation, pacing failure occurred, and chest radiography showed migration of the device into the right pulmonary artery. The following day, the device migrated to the left posterior basal segmental pulmonary artery and remained stably wedged. Because of the risk associated with retrieval, conservative management was selected, and a transvenous pacemaker was implanted. Serial lung perfusion scintigraphy demonstrated right-to-left perfusion distributions of 60.5% vs. 39.5% at 10 days, 59.1% vs. 40.9% at 3 months, and 58.5% vs. 41.5% at 1 year, without progressive deterioration in left lung volume. The patient remained asymptomatic over 3 years of follow-up. Discussion: This case illustrates that conservative management may be feasible in carefully selected high-risk patients when an embolized leadless pacemaker is stably wedged within the pulmonary artery. Serial pulmonary perfusion scintigraphy may provide objective evidence of preserved pulmonary perfusion and support long-term follow-up after conservative management.
- Open Access
- 17 September 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (5) , e70456
Association Between the Change in Interleukin‐6 Levels and Early Recurrence of Atrial Fibrillation: A Comparison of Pulsed Field Ablation and Radiofrequency Ablation
Background: Early recurrence of atrial fibrillation (ERAF) within the 3‐month blanking period is associated with procedural inflammation and increased risk of late recurrence. Pulsed field ablation (PFA) reportedly has a lower ERAF rate than radiofrequency ablation (RFA), but the underlying inflammatory mechanisms remain unclear. Methods: We compared 23 patients undergoing atrial fibrillation ablation (PFA: n = 16; RFA: n = 7). Perioperative changes in inflammatory markers, myocardial injury markers, hemolysis markers, and the incidence of ERAF were analyzed. Results: PFA exhibited significantly greater myocardial injury and hemolysis, but markedly lower systemic inflammation than RFA, characterized by lower Δinterleukin‐6 (IL‐6) levels (4.6 ± 1.7 vs. 8.1 ± 3.8 pg/mL, p = 0.008). ERAF occurred more frequently in RFA (3/7, 43% vs. 1/16, 6%, p = 0.033), which was accompanied by significantly higher ΔIL‐6 levels (9.1 ± 4.2 vs. 4.9 ± 2.3 pg/mL, p = 0.010). Multivariate logistic regression analysis identified ΔIL‐6 as an independent predictor of ERAF (OR 2.158, 95% CI 1.125–13.020, p = 0.013). Conclusions: PFA induces less systemic inflammation than RFA, despite causing greater myocardial injury. This reduced inflammatory response is independently associated with the lower incidence of ERAF.
- 17 September 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (5) , e70456
Open AccessAssociation Between the Change in Interleukin‐6 Levels and Early Recurrence of Atrial Fibrillation: A Comparison of Pulsed Field Ablation and Radiofrequency Ablation
Background: Early recurrence of atrial fibrillation (ERAF) within the 3‐month blanking period is associated with procedural inflammation and increased risk of late recurrence. Pulsed field ablation (PFA) reportedly has a lower ERAF rate than radiofrequency ablation (RFA), but the underlying inflammatory mechanisms remain unclear. Methods: We compared 23 patients undergoing atrial fibrillation ablation (PFA: n = 16; RFA: n = 7). Perioperative changes in inflammatory markers, myocardial injury markers, hemolysis markers, and the incidence of ERAF were analyzed. Results: PFA exhibited significantly greater myocardial injury and hemolysis, but markedly lower systemic inflammation than RFA, characterized by lower Δinterleukin‐6 (IL‐6) levels (4.6 ± 1.7 vs. 8.1 ± 3.8 pg/mL, p = 0.008). ERAF occurred more frequently in RFA (3/7, 43% vs. 1/16, 6%, p = 0.033), which was accompanied by significantly higher ΔIL‐6 levels (9.1 ± 4.2 vs. 4.9 ± 2.3 pg/mL, p = 0.010). Multivariate logistic regression analysis identified ΔIL‐6 as an independent predictor of ERAF (OR 2.158, 95% CI 1.125–13.020, p = 0.013). Conclusions: PFA induces less systemic inflammation than RFA, despite causing greater myocardial injury. This reduced inflammatory response is independently associated with the lower incidence of ERAF.
- Open Access
- 2 July 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (7)
Entrapment of a J-tip guidewire within the pulmonary vein during FARAPULSETM pulsed field ablation: a case report
Background: Pulsed field ablation (PFA) is a rapidly adopted technology for atrial fibrillation (AF) ablation and is associated with a favourable safety profile and a low risk of complications. However, mechanical complications have rarely been reported. Case summary: A 37-year-old Asian male with paroxysmal AF underwent PFA using the FARAPULSETM system. Following successful ablation of the left superior pulmonary vein (PV), the J-tip guidewire advanced into the left inferior PV and became completely entrapped. Venography demonstrated that, although the guidewire tip remained intravascular, a proximal segment appeared to course along the vessel wall, suggesting passage through an intraluminal structure. Multiple attempts at withdrawal using push-pull manoeuvres were unsuccessful. Repositioning with a radiofrequency ablation catheter also failed to release the entrapment. Given the risk of vessel rupture and major haemorrhage, the procedure was converted to general anaesthesia in a hybrid operating room with surgical standby. Bridge occlusion balloon-assisted extraction successfully released the entrapped guidewire without vascular injury. The retrieved guidewire had adherent fibrous white tissue, suggesting entrapment by a membranous pulmonary venous structure. Discussion: Balloon-assisted endovascular retrieval may represent a safe and less invasive alternative to surgical intervention for managing such entrapments. Operators should be aware of this rare but potentially hazardous complication.
- 2 July 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (7)
Open AccessEntrapment of a J-tip guidewire within the pulmonary vein during FARAPULSETM pulsed field ablation: a case report
Background: Pulsed field ablation (PFA) is a rapidly adopted technology for atrial fibrillation (AF) ablation and is associated with a favourable safety profile and a low risk of complications. However, mechanical complications have rarely been reported. Case summary: A 37-year-old Asian male with paroxysmal AF underwent PFA using the FARAPULSETM system. Following successful ablation of the left superior pulmonary vein (PV), the J-tip guidewire advanced into the left inferior PV and became completely entrapped. Venography demonstrated that, although the guidewire tip remained intravascular, a proximal segment appeared to course along the vessel wall, suggesting passage through an intraluminal structure. Multiple attempts at withdrawal using push-pull manoeuvres were unsuccessful. Repositioning with a radiofrequency ablation catheter also failed to release the entrapment. Given the risk of vessel rupture and major haemorrhage, the procedure was converted to general anaesthesia in a hybrid operating room with surgical standby. Bridge occlusion balloon-assisted extraction successfully released the entrapped guidewire without vascular injury. The retrieved guidewire had adherent fibrous white tissue, suggesting entrapment by a membranous pulmonary venous structure. Discussion: Balloon-assisted endovascular retrieval may represent a safe and less invasive alternative to surgical intervention for managing such entrapments. Operators should be aware of this rare but potentially hazardous complication.
- Open Access
- 14 November 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 7 (1) , 70-80
Combined assessment of nonalcoholic fatty liver disease fibrosis score and B-type natriuretic peptide for predicting atrial fibrillation recurrence after catheter ablation: A multicenter study
- 14 November 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 7 (1) , 70-80
Open AccessCombined assessment of nonalcoholic fatty liver disease fibrosis score and B-type natriuretic peptide for predicting atrial fibrillation recurrence after catheter ablation: A multicenter study
- Open Access
- 22 October 2025
- Published by Wiley in Journal of Arrhythmia
- Vol. 41 (5)
Explosion Risk of Cardiac Implantable Electronic Devices During Cremation: Experimental and Survey Findings From Japan
Background: The widespread use of cardiac implantable electronic devices (CIEDs), combined with increasing global cremation rates, has raised concerns regarding potential explosion risks during cremation. Lithium batteries within these devices may rupture due to heat‐induced internal pressure, potentially threatening crematorium infrastructure and staff safety. Despite these concerns, real‐world data on explosion behavior and its consequences remain limited. This study aimed to assess the explosion characteristics of CIEDs during cremation and evaluate their impact on facility safety, with the goal of informing evidence‐based guidelines. Methods: Combustion experiments were performed using full‐scale cremation furnaces set at 1100°C and 800°C. A total of 13 CIEDs (7 pacemakers and 6 implantable cardioverter‐defibrillators) were tested, with synchronized audio‐video monitoring. Additionally, nationwide survey data were collected from 2044 crematoria across Japan, focusing on cremation practices, reported damage, and staff injuries. Results: All tested devices exploded, with mean ignition‐to‐explosion times of 4.3 ± 1.1 min at 1100°C and 5.4 ± 2.0 min at 800°C ( p = 0.19). Seventeen explosion events were observed, yet no structural damage to the chambers occurred. Survey data revealed a decline in cremation refusal due to CIEDs—from 11.0% in 2012 to 4.6% in 2013 and 3.0% in 2014 ( p < 0.001). According to respondents, this trend likely reflects an increased collaboration with medical associations, modernization of crematorium facilities, and dissemination of practical safety information. Conclusions: Cremation of CIEDs without removal appears safe under modern, regulated facilities. However, region‐specific guidelines remain necessary due to international variability in infrastructure and practices.
- 22 October 2025
- Published by Wiley in Journal of Arrhythmia
- Vol. 41 (5)
Open AccessExplosion Risk of Cardiac Implantable Electronic Devices During Cremation: Experimental and Survey Findings From Japan
Background: The widespread use of cardiac implantable electronic devices (CIEDs), combined with increasing global cremation rates, has raised concerns regarding potential explosion risks during cremation. Lithium batteries within these devices may rupture due to heat‐induced internal pressure, potentially threatening crematorium infrastructure and staff safety. Despite these concerns, real‐world data on explosion behavior and its consequences remain limited. This study aimed to assess the explosion characteristics of CIEDs during cremation and evaluate their impact on facility safety, with the goal of informing evidence‐based guidelines. Methods: Combustion experiments were performed using full‐scale cremation furnaces set at 1100°C and 800°C. A total of 13 CIEDs (7 pacemakers and 6 implantable cardioverter‐defibrillators) were tested, with synchronized audio‐video monitoring. Additionally, nationwide survey data were collected from 2044 crematoria across Japan, focusing on cremation practices, reported damage, and staff injuries. Results: All tested devices exploded, with mean ignition‐to‐explosion times of 4.3 ± 1.1 min at 1100°C and 5.4 ± 2.0 min at 800°C ( p = 0.19). Seventeen explosion events were observed, yet no structural damage to the chambers occurred. Survey data revealed a decline in cremation refusal due to CIEDs—from 11.0% in 2012 to 4.6% in 2013 and 3.0% in 2014 ( p < 0.001). According to respondents, this trend likely reflects an increased collaboration with medical associations, modernization of crematorium facilities, and dissemination of practical safety information. Conclusions: Cremation of CIEDs without removal appears safe under modern, regulated facilities. However, region‐specific guidelines remain necessary due to international variability in infrastructure and practices.
- Open Access
- 30 July 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (21) , 104434
Tailored Endovascular Therapy for Deformed VIABAHN VBX Balloon-Expandable Stent Graft by External Force in Aortoiliac Disease
- 30 July 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (21) , 104434
Open AccessTailored Endovascular Therapy for Deformed VIABAHN VBX Balloon-Expandable Stent Graft by External Force in Aortoiliac Disease
- 9 April 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (7) , 1436-1450
Clinical Impact of High-Intensity Targeted Ablation of Identifiable Critical Zones in Scar-Related Ventricular Tachycardia
- 9 April 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (7) , 1436-1450
Clinical Impact of High-Intensity Targeted Ablation of Identifiable Critical Zones in Scar-Related Ventricular Tachycardia
- Open Access
- 7 January 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (1) , e035608
Diacylglycerol Kinase ζ Attenuates Doxorubicin‐Induced Cardiotoxicity Through p53 Degradation
Background: Doxorubicin‐induced cardiotoxicity is still an important medical problem associated with a high mortality rate in cancer survivors. p53 plays a key role in doxorubicin‐induced cardiotoxicity. Diacylglycerol kinase ζ (Dgkζ), a 130‐kDa enzyme abundant in cardiomyocytes, regulates the p53 protein expression level in neurons. To elucidate the mechanism of doxorubicin‐induced cardiotoxicity, we focused on the functional role of Dgkζ and its interaction with heat shock protein 70 (Hsp70)–related ubiquitin E3 ligases such as E6‐associated protein (E6ap) and C‐terminus of Hsp70‐interacting protein. Methods and Results: Protein interactions of Dgkζ with Hsp70 and E6ap were confirmed by immunoprecipitation, but not C‐terminus of Hsp70‐interacting protein. We administered doxorubicin in cardiac‐specific overexpression of Dgkζ transgenic (Dgkζ‐Tg) mice and wild‐type littermates. Dgkζ‐Tg mice showed lower p53 protein expression levels, preserved cardiac function, and improved survival rates compared with wild‐type littermates after doxorubicin administration. RNA sequence analysis of myocardial tissues from Dgkζ‐Tg after doxorubicin stimulation identified Hspa1b encoding Hsp70 as the differentially expressed gene. Dgkζ overexpression increased proteasomal p53 degradation and attenuated cardiomyocyte apoptosis after doxorubicin stimulation in cardiomyocytes, which was reversed by knockdown of E6ap. Dgkζ interacted with E6ap through ankyrin‐like repeats. The overexpression of mutant Dgkζ, lacking ankyrin‐like repeats, failed to inhibit p53 protein expression after doxorubicin stimulation. In Dgkζ‐overexpressing cardiomyocytes, expression levels of p53 and caspase‐3 were increased by knockdown of the C‐terminus of Hsp70‐interacting protein. Conclusions: We demonstrated for the first time that Dgkζ augments p53 ubiquitin‐proteasome degradation and ameliorates doxorubicin‐induced cardiotoxicity by interacting with Hsp70 and E3 ligases such as E6ap and C‐terminus of Hsp70‐interacting protein.
- 7 January 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (1) , e035608
Open AccessDiacylglycerol Kinase ζ Attenuates Doxorubicin‐Induced Cardiotoxicity Through p53 Degradation
Background: Doxorubicin‐induced cardiotoxicity is still an important medical problem associated with a high mortality rate in cancer survivors. p53 plays a key role in doxorubicin‐induced cardiotoxicity. Diacylglycerol kinase ζ (Dgkζ), a 130‐kDa enzyme abundant in cardiomyocytes, regulates the p53 protein expression level in neurons. To elucidate the mechanism of doxorubicin‐induced cardiotoxicity, we focused on the functional role of Dgkζ and its interaction with heat shock protein 70 (Hsp70)–related ubiquitin E3 ligases such as E6‐associated protein (E6ap) and C‐terminus of Hsp70‐interacting protein. Methods and Results: Protein interactions of Dgkζ with Hsp70 and E6ap were confirmed by immunoprecipitation, but not C‐terminus of Hsp70‐interacting protein. We administered doxorubicin in cardiac‐specific overexpression of Dgkζ transgenic (Dgkζ‐Tg) mice and wild‐type littermates. Dgkζ‐Tg mice showed lower p53 protein expression levels, preserved cardiac function, and improved survival rates compared with wild‐type littermates after doxorubicin administration. RNA sequence analysis of myocardial tissues from Dgkζ‐Tg after doxorubicin stimulation identified Hspa1b encoding Hsp70 as the differentially expressed gene. Dgkζ overexpression increased proteasomal p53 degradation and attenuated cardiomyocyte apoptosis after doxorubicin stimulation in cardiomyocytes, which was reversed by knockdown of E6ap. Dgkζ interacted with E6ap through ankyrin‐like repeats. The overexpression of mutant Dgkζ, lacking ankyrin‐like repeats, failed to inhibit p53 protein expression after doxorubicin stimulation. In Dgkζ‐overexpressing cardiomyocytes, expression levels of p53 and caspase‐3 were increased by knockdown of the C‐terminus of Hsp70‐interacting protein. Conclusions: We demonstrated for the first time that Dgkζ augments p53 ubiquitin‐proteasome degradation and ameliorates doxorubicin‐induced cardiotoxicity by interacting with Hsp70 and E3 ligases such as E6ap and C‐terminus of Hsp70‐interacting protein.
- Open Access
- 16 September 2024
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 47 (10) , 1362-1365
Junctional Beats During Daily Activities Induced Unusual Behavior of Managed Ventricular Pacing: What Is the Mechanism?
- 16 September 2024
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 47 (10) , 1362-1365
Open AccessJunctional Beats During Daily Activities Induced Unusual Behavior of Managed Ventricular Pacing: What Is the Mechanism?