TATakanori Arimoto

Takanori Arimoto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takanori Arimoto has a total of 248 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Novel Bundle Branch Re-Entrant Ventricular Tachycardia Using a Septal Purkinje Network as the Retrograde Limb

    by Naoaki Hashimoto, Akihiko Nogami, Takanori Arimoto, Yuki Komatsu, Kyoko Koyama, Masafumi Watanabe

  • Open Access

    Conservative management of a dislodged leadless pacemaker wedged in the pulmonary artery assessed by pulmonary perfusion scintigraphy: a case report

    by Takanori Arimoto, Daisuke Kutsuzawa, Naoaki Hashimoto, Ken Watanabe, Masafumi Watanabe

    Background: Leadless pacemakers reduce complications associated with conventional transvenous systems; however, device dislodgement with pulmonary artery embolization is a rare complication unique to leadless pacemakers. Although prompt retrieval is generally recommended, retrieval from the pulmonary artery may carry procedural risks, particularly in elderly or high-risk patients. Case summary: An 84-year-old woman with complete atrioventricular block underwent implantation of a leadless pacemaker. Although the pacing threshold was favourable, the R-wave amplitude was low, and unstable device movement was observed after tether release, suggesting inadequate fixation. Two hours after implantation, pacing failure occurred, and chest radiography showed migration of the device into the right pulmonary artery. The following day, the device migrated to the left posterior basal segmental pulmonary artery and remained stably wedged. Because of the risk associated with retrieval, conservative management was selected, and a transvenous pacemaker was implanted. Serial lung perfusion scintigraphy demonstrated right-to-left perfusion distributions of 60.5% vs. 39.5% at 10 days, 59.1% vs. 40.9% at 3 months, and 58.5% vs. 41.5% at 1 year, without progressive deterioration in left lung volume. The patient remained asymptomatic over 3 years of follow-up. Discussion: This case illustrates that conservative management may be feasible in carefully selected high-risk patients when an embolized leadless pacemaker is stably wedged within the pulmonary artery. Serial pulmonary perfusion scintigraphy may provide objective evidence of preserved pulmonary perfusion and support long-term follow-up after conservative management.

  • Open Access

    Association Between the Change in Interleukin‐6 Levels and Early Recurrence of Atrial Fibrillation: A Comparison of Pulsed Field Ablation and Radiofrequency Ablation

    by Ken Watanabe, Takanori Arimoto, Mashu Toyoshima, Kyoko Koyama, Yuta Kobayashi, Naoaki Hashimoto, Masafumi Watanabe

    Background: Early recurrence of atrial fibrillation (ERAF) within the 3‐month blanking period is associated with procedural inflammation and increased risk of late recurrence. Pulsed field ablation (PFA) reportedly has a lower ERAF rate than radiofrequency ablation (RFA), but the underlying inflammatory mechanisms remain unclear. Methods: We compared 23 patients undergoing atrial fibrillation ablation (PFA: n = 16; RFA: n = 7). Perioperative changes in inflammatory markers, myocardial injury markers, hemolysis markers, and the incidence of ERAF were analyzed. Results: PFA exhibited significantly greater myocardial injury and hemolysis, but markedly lower systemic inflammation than RFA, characterized by lower Δinterleukin‐6 (IL‐6) levels (4.6 ± 1.7 vs. 8.1 ± 3.8 pg/mL, p = 0.008). ERAF occurred more frequently in RFA (3/7, 43% vs. 1/16, 6%, p = 0.033), which was accompanied by significantly higher ΔIL‐6 levels (9.1 ± 4.2 vs. 4.9 ± 2.3 pg/mL, p = 0.010). Multivariate logistic regression analysis identified ΔIL‐6 as an independent predictor of ERAF (OR 2.158, 95% CI 1.125–13.020, p = 0.013). Conclusions: PFA induces less systemic inflammation than RFA, despite causing greater myocardial injury. This reduced inflammatory response is independently associated with the lower incidence of ERAF.

  • Open Access

    Entrapment of a J-tip guidewire within the pulmonary vein during FARAPULSETM pulsed field ablation: a case report

    by Ken Watanabe, Takanori Arimoto, Yuta Kobayashi, Naoaki Hashimoto, Masafumi Watanabe

    Background: Pulsed field ablation (PFA) is a rapidly adopted technology for atrial fibrillation (AF) ablation and is associated with a favourable safety profile and a low risk of complications. However, mechanical complications have rarely been reported. Case summary: A 37-year-old Asian male with paroxysmal AF underwent PFA using the FARAPULSETM system. Following successful ablation of the left superior pulmonary vein (PV), the J-tip guidewire advanced into the left inferior PV and became completely entrapped. Venography demonstrated that, although the guidewire tip remained intravascular, a proximal segment appeared to course along the vessel wall, suggesting passage through an intraluminal structure. Multiple attempts at withdrawal using push-pull manoeuvres were unsuccessful. Repositioning with a radiofrequency ablation catheter also failed to release the entrapment. Given the risk of vessel rupture and major haemorrhage, the procedure was converted to general anaesthesia in a hybrid operating room with surgical standby. Bridge occlusion balloon-assisted extraction successfully released the entrapped guidewire without vascular injury. The retrieved guidewire had adherent fibrous white tissue, suggesting entrapment by a membranous pulmonary venous structure. Discussion: Balloon-assisted endovascular retrieval may represent a safe and less invasive alternative to surgical intervention for managing such entrapments. Operators should be aware of this rare but potentially hazardous complication.

  • Open Access

    Combined assessment of nonalcoholic fatty liver disease fibrosis score and B-type natriuretic peptide for predicting atrial fibrillation recurrence after catheter ablation: A multicenter study

    by Kyoko Koyama, Naoaki Hashimoto, Takanori Arimoto, Daisuke Kutsuzawa, Ken Watanabe, Yuta Kobayashi, Mashu Toyoshima, Daisuke Kinoshita, Masahiro Wanezaki, Yoichiro Otaki, et al.

  • Open Access

    Explosion Risk of Cardiac Implantable Electronic Devices During Cremation: Experimental and Survey Findings From Japan

    by Takanori Arimoto, Yasushi Oginosawa, Katsuya Ebe, Masatomo Takahashi, Eiichi Watanabe, Haruhiko Abe, Masahiko Takagi, Hiroshi Tada, The Japanese Heart Rhythm Society

    Background: The widespread use of cardiac implantable electronic devices (CIEDs), combined with increasing global cremation rates, has raised concerns regarding potential explosion risks during cremation. Lithium batteries within these devices may rupture due to heat‐induced internal pressure, potentially threatening crematorium infrastructure and staff safety. Despite these concerns, real‐world data on explosion behavior and its consequences remain limited. This study aimed to assess the explosion characteristics of CIEDs during cremation and evaluate their impact on facility safety, with the goal of informing evidence‐based guidelines. Methods: Combustion experiments were performed using full‐scale cremation furnaces set at 1100°C and 800°C. A total of 13 CIEDs (7 pacemakers and 6 implantable cardioverter‐defibrillators) were tested, with synchronized audio‐video monitoring. Additionally, nationwide survey data were collected from 2044 crematoria across Japan, focusing on cremation practices, reported damage, and staff injuries. Results: All tested devices exploded, with mean ignition‐to‐explosion times of 4.3 ± 1.1 min at 1100°C and 5.4 ± 2.0 min at 800°C ( p = 0.19). Seventeen explosion events were observed, yet no structural damage to the chambers occurred. Survey data revealed a decline in cremation refusal due to CIEDs—from 11.0% in 2012 to 4.6% in 2013 and 3.0% in 2014 ( p < 0.001). According to respondents, this trend likely reflects an increased collaboration with medical associations, modernization of crematorium facilities, and dissemination of practical safety information. Conclusions: Cremation of CIEDs without removal appears safe under modern, regulated facilities. However, region‐specific guidelines remain necessary due to international variability in infrastructure and practices.

  • Open Access

    Tailored Endovascular Therapy for Deformed VIABAHN VBX Balloon-Expandable Stent Graft by External Force in Aortoiliac Disease

    by Taku Shikama, Yoichiro Otaki, Tetsu Watanabe, Harutoshi Tamura, Shigehiko Kato, Satoshi Nishiyama, Hiroki Takahashi, Takanori Arimoto, Masafumi Watanabe

  • Clinical Impact of High-Intensity Targeted Ablation of Identifiable Critical Zones in Scar-Related Ventricular Tachycardia

    by Yuka Oda, Yuki Komatsu, Yasutoshi Shinoda, Yuichi Hanaki, Masayuki Hattori, Naoaki Hashimoto, Takashi Kanda, Fumiharu Miura, Naoya Hironobe, Yuto Iioka, et al.


  • Open Access

    Diacylglycerol Kinase ζ Attenuates Doxorubicin‐Induced Cardiotoxicity Through p53 Degradation

    by Shingo Tachibana, Yoichiro Otaki, Tetsu Watanabe, Jun Goto, Haruki Ochi, Toshiaki Tanaka, Hiroe Ono, Ryuhei Yamaguchi, Junya Sato, Hiroki Takahashi, et al.

    Background: Doxorubicin‐induced cardiotoxicity is still an important medical problem associated with a high mortality rate in cancer survivors. p53 plays a key role in doxorubicin‐induced cardiotoxicity. Diacylglycerol kinase ζ (Dgkζ), a 130‐kDa enzyme abundant in cardiomyocytes, regulates the p53 protein expression level in neurons. To elucidate the mechanism of doxorubicin‐induced cardiotoxicity, we focused on the functional role of Dgkζ and its interaction with heat shock protein 70 (Hsp70)–related ubiquitin E3 ligases such as E6‐associated protein (E6ap) and C‐terminus of Hsp70‐interacting protein. Methods and Results: Protein interactions of Dgkζ with Hsp70 and E6ap were confirmed by immunoprecipitation, but not C‐terminus of Hsp70‐interacting protein. We administered doxorubicin in cardiac‐specific overexpression of Dgkζ transgenic (Dgkζ‐Tg) mice and wild‐type littermates. Dgkζ‐Tg mice showed lower p53 protein expression levels, preserved cardiac function, and improved survival rates compared with wild‐type littermates after doxorubicin administration. RNA sequence analysis of myocardial tissues from Dgkζ‐Tg after doxorubicin stimulation identified Hspa1b encoding Hsp70 as the differentially expressed gene. Dgkζ overexpression increased proteasomal p53 degradation and attenuated cardiomyocyte apoptosis after doxorubicin stimulation in cardiomyocytes, which was reversed by knockdown of E6ap. Dgkζ interacted with E6ap through ankyrin‐like repeats. The overexpression of mutant Dgkζ, lacking ankyrin‐like repeats, failed to inhibit p53 protein expression after doxorubicin stimulation. In Dgkζ‐overexpressing cardiomyocytes, expression levels of p53 and caspase‐3 were increased by knockdown of the C‐terminus of Hsp70‐interacting protein. Conclusions: We demonstrated for the first time that Dgkζ augments p53 ubiquitin‐proteasome degradation and ameliorates doxorubicin‐induced cardiotoxicity by interacting with Hsp70 and E3 ligases such as E6ap and C‐terminus of Hsp70‐interacting protein.


  • Open Access

    Junctional Beats During Daily Activities Induced Unusual Behavior of Managed Ventricular Pacing: What Is the Mechanism?

    by Daisuke Kutsuzawa, Takanori Arimoto, Daiki Saito, Takeru Gando, Jun Yakuwa, Naoaki Hashimoto, Yuta Kobayashi, Kyoko Koyama, Masafumi Watanabe