Avi Abadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Avi Abadi has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Gabor Kosa
School of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel
2 shared publications- Gabor Kosa
School of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel
1 shared publication - Roni Amit
School of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Ramat Aviv, Tel Aviv, Prefix: 69978, Israel
1 shared publication
Latest Publications
- 9 March 2018
- Published by Springer Nature in Biomedical Microdevices
- Vol. 20 (2) , 28
Closed loop control of microscopic particles incorporating steady streaming and visual feedback
Automatic manipulation of microscopic particles is very important in biology, especially in new lab-on-chip systems for automatic testing and DNA manipulation. We suggest a particle manipulation system (PMS) based on vibrating piezoelectric beams creating steady streaming flow in a viscous liquid. The flow is nearly unidirectional and it is used to control the position and velocity of the particles in the workspace of the PMS. The particles position in the PMS are controlled by visual feedback. This study presents the manipulation method, the system’s model describing its behavior and characterizes experimentally its performance. The PMS is capable moving a 2-200 μm particle in a workspace of 8x8 mm2 with an absolute accuracy of 0.2 μm. The characteristic velocity in 500 cP Si oil, is 20 μm/s using an actuation voltage amplitude of 5 V and can reach 250 μm/s using 15 V respectively. We can also move a constellation of several particles in various sizes without changing the distance between them. The accuracy of the manipulation can be increased by enhancing the amplification of the microscope on the expanse of a smaller workspace field of view.
- 9 March 2018
- Published by Springer Nature in Biomedical Microdevices
- Vol. 20 (2) , 28
Closed loop control of microscopic particles incorporating steady streaming and visual feedback
Automatic manipulation of microscopic particles is very important in biology, especially in new lab-on-chip systems for automatic testing and DNA manipulation. We suggest a particle manipulation system (PMS) based on vibrating piezoelectric beams creating steady streaming flow in a viscous liquid. The flow is nearly unidirectional and it is used to control the position and velocity of the particles in the workspace of the PMS. The particles position in the PMS are controlled by visual feedback. This study presents the manipulation method, the system’s model describing its behavior and characterizes experimentally its performance. The PMS is capable moving a 2-200 μm particle in a workspace of 8x8 mm2 with an absolute accuracy of 0.2 μm. The characteristic velocity in 500 cP Si oil, is 20 μm/s using an actuation voltage amplitude of 5 V and can reach 250 μm/s using 15 V respectively. We can also move a constellation of several particles in various sizes without changing the distance between them. The accuracy of the manipulation can be increased by enhancing the amplification of the microscope on the expanse of a smaller workspace field of view.
- 23 April 2016
- Published by Springer Nature in Biomedical Microdevices
- Vol. 18 (2) , 1-19
Characterization of steady streaming for a particle manipulation system
Accurate positioning of biological cells or microscopic particle without directly contacting them is a challenging task in biomedical engineering. Various trapping methods for controlling the position of a particle have been suggested. The common driving methods are based on laser and ultrasonic actuation principles. In this work we suggest a design for a hydrodynamic particle manoeuvring system. The system operates using steady streaming in a viscous fluid media induced by high frequency vibration of piezoelectric cantilevers. A particle within the workspace of the system can be trapped and manipulated to a desired position by the fairly unidirectional flow field created by the beams. In this paper, the flow field in the particle manipulation system is characterized numerically and experimentally. We find that the flow field resembles the analytical solutions of a flow field created by an oscillating sphere. Furthermore, we validate numerically the quadratic relation between the steady streaming velocity and the vibration amplitude of the beam. The calibration of the piezoelectric actuator’s oscillation amplitudes enables effective positioning of particles with a diameter of 20 um to 1 mm. We find that a 30X0.8X2 m m 3 piezoelectric beam vibrating at its first resonance frequency, 200 Hz, is able to move a particle at a typical flow velocity ranging between 0.05 mm/sec and 0.13 mm/s in 430 cSt Si oil (Re=0.2).
- 23 April 2016
- Published by Springer Nature in Biomedical Microdevices
- Vol. 18 (2) , 1-19
Characterization of steady streaming for a particle manipulation system
Accurate positioning of biological cells or microscopic particle without directly contacting them is a challenging task in biomedical engineering. Various trapping methods for controlling the position of a particle have been suggested. The common driving methods are based on laser and ultrasonic actuation principles. In this work we suggest a design for a hydrodynamic particle manoeuvring system. The system operates using steady streaming in a viscous fluid media induced by high frequency vibration of piezoelectric cantilevers. A particle within the workspace of the system can be trapped and manipulated to a desired position by the fairly unidirectional flow field created by the beams. In this paper, the flow field in the particle manipulation system is characterized numerically and experimentally. We find that the flow field resembles the analytical solutions of a flow field created by an oscillating sphere. Furthermore, we validate numerically the quadratic relation between the steady streaming velocity and the vibration amplitude of the beam. The calibration of the piezoelectric actuator’s oscillation amplitudes enables effective positioning of particles with a diameter of 20 um to 1 mm. We find that a 30X0.8X2 m m 3 piezoelectric beam vibrating at its first resonance frequency, 200 Hz, is able to move a particle at a typical flow velocity ranging between 0.05 mm/sec and 0.13 mm/s in 430 cSt Si oil (Re=0.2).
- 21 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 21 (3) , 1528-1539
Piezoelectric Beam for Intrabody Propulsion Controlled by Embedded Sensing
The body is a very challenging environment for locomotion. The mechanical properties of intrabody fluids and tissues vary by location and time. In order to move an embedded biomedical device such as a deep brain stimulation electrode, one has to identify the properties of the environment and set the propulsive actuator's input accordingly. We developed a piezoelectric actuator for propelling a microrobot in cerebro spinal fluid or burrowing in the brain tissue parenchyma. The propulsion is created by the vibration of the beam at the resonance frequencies. The driving of the actuators is controlled by in situ multi-input multi-output system identification (SI) using part of the beam as sensor and part as actuator. In this study, we model the sensing of the device, present the SI method, the calculation of the input signals to achieve maximal propulsion, and we test the driving method experimentally. The microactuator is examined in 500-cP silicon oil and a 20-mm-long actuator can achieve 3-μN propulsive force.
- 21 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 21 (3) , 1528-1539
Piezoelectric Beam for Intrabody Propulsion Controlled by Embedded Sensing
The body is a very challenging environment for locomotion. The mechanical properties of intrabody fluids and tissues vary by location and time. In order to move an embedded biomedical device such as a deep brain stimulation electrode, one has to identify the properties of the environment and set the propulsive actuator's input accordingly. We developed a piezoelectric actuator for propelling a microrobot in cerebro spinal fluid or burrowing in the brain tissue parenchyma. The propulsion is created by the vibration of the beam at the resonance frequencies. The driving of the actuators is controlled by in situ multi-input multi-output system identification (SI) using part of the beam as sensor and part as actuator. In this study, we model the sensing of the device, present the SI method, the calculation of the input signals to achieve maximal propulsion, and we test the driving method experimentally. The microactuator is examined in 500-cP silicon oil and a 20-mm-long actuator can achieve 3-μN propulsive force.