Jayson Wharton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jayson Wharton has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Brian Bucher
Idaho National Laboratory, Idaho Falls, USA
4 shared publications - Dong-Won Lee
Lawrence Livermore National Laboratory
4 shared publications - Edward Seabury
Idaho National Lab. (INL), Idaho Falls, ID (United States)
4 shared publications Kenneth M Krebs
Idaho National Lab. (INL), Idaho Falls, ID (United States)
3 shared publications- A. J. Caffrey
Idaho National Lab. (INL), Idaho Falls, ID (United States)
2 shared publications B. D. Milbrath
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
1 shared publication
Latest Publications
- 7 April 2020
- Published by Office of Scientific and Technical Information (OSTI)
Application of Gaussian Bayes classifier to differentiate chlorine-based chemical agents
The U.S. Department of Energy's Office of Scientific and Technical Information
- 7 April 2020
- Published by Office of Scientific and Technical Information (OSTI)
Application of Gaussian Bayes classifier to differentiate chlorine-based chemical agents
The U.S. Department of Energy's Office of Scientific and Technical Information
- 29 May 2019
- Published by Office of Scientific and Technical Information (OSTI)
Determination of the Deuterium-Tritium (D-T) Generator Neutron Flux using Multi-foil Neutron Activation Analysis Method
The deuterium-tritium (D-T) neutron flux from a Thermo-Fisher™ MP320 neutron generator was determined experimentally in this study. Fast neutron flux from a neutron generator can be measured indirectly using multi-foil activation analysis. Two sets of 12 activation foils each were prepared to cover a broad energy range of fast neutrons (1 – 15 MeV), and spectral peak analysis was performed on each activated foil with a mechanically-cooled HPGe detector. A non-negative solution of a linear least squares problem was solved to find a neutron flux energy distribution. The neutron yields of the high-yield (60 µA-90 kV) and low-yield (30 µA-70 kV) settings were determined to be 1.73×108 n/s and 2.28×107 n/s, respectively. Uncertainties on these neutron yields were estimated using the BC400 scintillator count rates whose fluctuations throughout the irradiations were described by the standard deviations of 10.6 and 8.5%, respectively. Linear relationships between the MP320’s neutron flux and a BC400 scintillator as well as a SWENDI-2 neutron dose meter were also derived to utilize them as on-line neutron flux monitors in the future.
- 29 May 2019
- Published by Office of Scientific and Technical Information (OSTI)
Determination of the Deuterium-Tritium (D-T) Generator Neutron Flux using Multi-foil Neutron Activation Analysis Method
The deuterium-tritium (D-T) neutron flux from a Thermo-Fisher™ MP320 neutron generator was determined experimentally in this study. Fast neutron flux from a neutron generator can be measured indirectly using multi-foil activation analysis. Two sets of 12 activation foils each were prepared to cover a broad energy range of fast neutrons (1 – 15 MeV), and spectral peak analysis was performed on each activated foil with a mechanically-cooled HPGe detector. A non-negative solution of a linear least squares problem was solved to find a neutron flux energy distribution. The neutron yields of the high-yield (60 µA-90 kV) and low-yield (30 µA-70 kV) settings were determined to be 1.73×108 n/s and 2.28×107 n/s, respectively. Uncertainties on these neutron yields were estimated using the BC400 scintillator count rates whose fluctuations throughout the irradiations were described by the standard deviations of 10.6 and 8.5%, respectively. Linear relationships between the MP320’s neutron flux and a BC400 scintillator as well as a SWENDI-2 neutron dose meter were also derived to utilize them as on-line neutron flux monitors in the future.
- 1 April 2019
- Published by Office of Scientific and Technical Information (OSTI)
Experimental Validation of MCNP Models for PINS Shadow Shield Mockups
MCNP has been regarded as an indispensable tool in development of radiation detection systems, and it is cost effective, thanks to advances in computing power, to simulate various conceptual designs without even fabricating them. Development of various PINS systems have also benefited from MCNP modeling and simulation. MCNP models of PINS systems have been frequently used to understand detector responses and to fill the gap in experimental data. Recently, a backpack version PINS system was announced to be developed. When the neutron generator and the HPGe detector are built by external vendors, the shadow shield is the component to be designed to maximize the performance while meeting the sponsor’s requirements. In order to utilize MCNP modeling and simulation to find the best specification of the shadow shield, a campaign of PINS lab measurements with a few shadow shield mockups has been conducted to validate MCNP simulation results. This study is intended to validate MCNP simulations and models in preparation of another more extensive simulation study. Validation of neutron flux is also discussed later in this report even though neutron counts were not measured experimentally.
- 1 April 2019
- Published by Office of Scientific and Technical Information (OSTI)
Experimental Validation of MCNP Models for PINS Shadow Shield Mockups
MCNP has been regarded as an indispensable tool in development of radiation detection systems, and it is cost effective, thanks to advances in computing power, to simulate various conceptual designs without even fabricating them. Development of various PINS systems have also benefited from MCNP modeling and simulation. MCNP models of PINS systems have been frequently used to understand detector responses and to fill the gap in experimental data. Recently, a backpack version PINS system was announced to be developed. When the neutron generator and the HPGe detector are built by external vendors, the shadow shield is the component to be designed to maximize the performance while meeting the sponsor’s requirements. In order to utilize MCNP modeling and simulation to find the best specification of the shadow shield, a campaign of PINS lab measurements with a few shadow shield mockups has been conducted to validate MCNP simulation results. This study is intended to validate MCNP simulations and models in preparation of another more extensive simulation study. Validation of neutron flux is also discussed later in this report even though neutron counts were not measured experimentally.
- 1 October 2018
- Published by Office of Scientific and Technical Information (OSTI)
On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System-Integration and Field-Testing Report
We have designed a system for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—OSIRIS —gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC IDM-200V, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. Spectral data analysis is similar to that performed by traditional gamma-ray spectrometers, except the OSIRIS gamma-ray spectral data are filtered to display only radioisotopic information relevant to CTBT on-site inspections, for example, the fission-product isotope Zr-95 and its daughter isotope Nb-95. The OSIRIS software assists the user during operation with software checklists for startup and shutdown, and menu-selected display windows during energy calibration and data acquisition. OSIRIS can be operated in either sample-counting mode or the in-situ mode. In this report, the extensive system-integration tests of the OSIRIS system carried out in 2015-2017 are described, including tests at Idaho National Laboratory, at the Nevada National Security Site (formerly, the Nevada Test Site), and at Pacific Northwest National Laboratory in Richland, Washington. We also note recent software enhancements and the steps to our successful commercialization of OSIRIS.
- 1 October 2018
- Published by Office of Scientific and Technical Information (OSTI)
On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System-Integration and Field-Testing Report
We have designed a system for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—OSIRIS —gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC IDM-200V, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. Spectral data analysis is similar to that performed by traditional gamma-ray spectrometers, except the OSIRIS gamma-ray spectral data are filtered to display only radioisotopic information relevant to CTBT on-site inspections, for example, the fission-product isotope Zr-95 and its daughter isotope Nb-95. The OSIRIS software assists the user during operation with software checklists for startup and shutdown, and menu-selected display windows during energy calibration and data acquisition. OSIRIS can be operated in either sample-counting mode or the in-situ mode. In this report, the extensive system-integration tests of the OSIRIS system carried out in 2015-2017 are described, including tests at Idaho National Laboratory, at the Nevada National Security Site (formerly, the Nevada Test Site), and at Pacific Northwest National Laboratory in Richland, Washington. We also note recent software enhancements and the steps to our successful commercialization of OSIRIS.
- 6 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
MCNP simulation of discrete gamma-ray spectra for PGNAA applications
Prompt Gamma Neutron Activation Analysis (PGNAA) systems, such as Idaho National Laboratory's PINS system [1], are used by the U.S. Army to identify chemical warfare materiel (CWM) and explosives in recovered munitions. The wide variety of fill chemicals and assessment conditions for these munitions makes Monte Carlo modeling of the gamma spectra attractive in order to assess the impact of these variations on identification algorithms as have recent improvements to the prompt gamma production in the nuclear data libraries for low-Z chemical elements. The availability of High Performance Computing (HPC) systems makes these simulations more rapid than laboratory measurements, and can be very useful provided the codes and associated data libraries accurately reproduce the laboratory measurements. We present here a comparison of simulation results using the MCNP6 code [2] and the ENDF/B-VII libraries with laboratory measurements using two different neutron sources, a californium-252 source and a deuterium-deuterium (DD) neutron generator.
- 6 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
MCNP simulation of discrete gamma-ray spectra for PGNAA applications
Prompt Gamma Neutron Activation Analysis (PGNAA) systems, such as Idaho National Laboratory's PINS system [1], are used by the U.S. Army to identify chemical warfare materiel (CWM) and explosives in recovered munitions. The wide variety of fill chemicals and assessment conditions for these munitions makes Monte Carlo modeling of the gamma spectra attractive in order to assess the impact of these variations on identification algorithms as have recent improvements to the prompt gamma production in the nuclear data libraries for low-Z chemical elements. The availability of High Performance Computing (HPC) systems makes these simulations more rapid than laboratory measurements, and can be very useful provided the codes and associated data libraries accurately reproduce the laboratory measurements. We present here a comparison of simulation results using the MCNP6 code [2] and the ENDF/B-VII libraries with laboratory measurements using two different neutron sources, a californium-252 source and a deuterium-deuterium (DD) neutron generator.