Dong-Won Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dong-Won Lee has a total of 303 co-authors. Here are the top co-authors by number of shared publications:
- Jei-Pil Wang
BB21 Plus Team, Department of Metallurgical Engineering, Pukyong National University, Busan 48513, Republic of Korea
5 shared publications Jung-Yeul Yun
5 shared publications- Brian Bucher
Idaho National Laboratory, Idaho Falls, USA
4 shared publications - Edward Seabury
Idaho National Lab. (INL), Idaho Falls, ID (United States)
4 shared publications - Jayson Wharton
Idaho National Lab. (INL), Idaho Falls, ID (United States)
4 shared publications Tae-Doo Park
4 shared publications
Latest Publications
- 24 September 2026
- Published by Elsevier in Earth and Planetary Science Letters
- Vol. 695
A new half-life for 146Sm: Implications for lunar chronology
- 24 September 2026
- Published by Elsevier in Earth and Planetary Science Letters
- Vol. 695
A new half-life for 146Sm: Implications for lunar chronology
- Open Access
- 26 February 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (2)
Search for a heavy neutral lepton with the MAGNETO- ν experiment using Pu 241 β − decays
The MAGNETO- ν experiment searches for keV-scale heavy neutral leptons (HNLs) through precise measurements of the β − -decay spectrum of Pu 241 . We present spectra comprising a total of 194 million β − decays recorded using decay energy spectrometry with metallic magnetic calorimeters, representing the most statistically precise measurement of Pu 241 β − decay to date. The β -endpoint energy was determined using γ rays and x-rays from an external Ba 133 calibration source, yielding Q β = 22.273 ( 33 ) keV . The measured spectrum shows no statistically significant deviation from the allowed β -decay model. From a subset of the high-statistics data, we set an upper limit on the mixing of an 11.5-keV HNL with the electron neutrino, | U e 4 | 2 < 1.31 × 10 − 3 at the 95% confidence level.
- 26 February 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (2)
Open AccessSearch for a heavy neutral lepton with the MAGNETO- ν experiment using Pu 241 β − decays
The MAGNETO- ν experiment searches for keV-scale heavy neutral leptons (HNLs) through precise measurements of the β − -decay spectrum of Pu 241 . We present spectra comprising a total of 194 million β − decays recorded using decay energy spectrometry with metallic magnetic calorimeters, representing the most statistically precise measurement of Pu 241 β − decay to date. The β -endpoint energy was determined using γ rays and x-rays from an external Ba 133 calibration source, yielding Q β = 22.273 ( 33 ) keV . The measured spectrum shows no statistically significant deviation from the allowed β -decay model. From a subset of the high-statistics data, we set an upper limit on the mixing of an 11.5-keV HNL with the electron neutrino, | U e 4 | 2 < 1.31 × 10 − 3 at the 95% confidence level.
- 16 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (6) , 1352-1356
Development of a Portable Pixelated Fast-Neutron Imaging Panel
Oak Ridge National Laboratory is developing a portable, pixelated fast-neutron imaging panel for associated particle imaging (API). The panel consists of new and commercially available hardware. Unlike the current generation of API-based neutron imaging systems, this panel is intended to be field deployable. A $30\times30$ array of optically isolated 1 cm $\times$ 1 cm $\times$ 5 cm pulse shape discriminating (PSD) plastic scintillator pixels are optically coupled to a $6\times6$ array of position-sensitive photomultiplier tubes (PMTs) allowing each pixel to be resolved. Each quadrant of $3\times3$ PMTs recombines the 576 PMT anodes using a resistive charge division network to achieve four-corner readout that preserves the average position of the detected light. The design of the panel and initial testing of the light collection and position encoding electronics is presented herein.
- 16 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (6) , 1352-1356
Development of a Portable Pixelated Fast-Neutron Imaging Panel
Oak Ridge National Laboratory is developing a portable, pixelated fast-neutron imaging panel for associated particle imaging (API). The panel consists of new and commercially available hardware. Unlike the current generation of API-based neutron imaging systems, this panel is intended to be field deployable. A $30\times30$ array of optically isolated 1 cm $\times$ 1 cm $\times$ 5 cm pulse shape discriminating (PSD) plastic scintillator pixels are optically coupled to a $6\times6$ array of position-sensitive photomultiplier tubes (PMTs) allowing each pixel to be resolved. Each quadrant of $3\times3$ PMTs recombines the 576 PMT anodes using a resistive charge division network to achieve four-corner readout that preserves the average position of the detected light. The design of the panel and initial testing of the light collection and position encoding electronics is presented herein.
- 12 October 2021
- Published by Office of Scientific and Technical Information (OSTI)
Material Identification Using Dual Energy X-ray Absorptiometry
Two implementations of dual energy X-ray absorptiometry were studied to identify materials using X-ray attenuation data taken with the Digital Radiography and Computed Tomography (DRCT) systems that were developed for the Recovered Chemical Materiel Directorate (RCMD). Maitrejean et al.’s approach utilizes eigen effects through Principal Component Analysis, while Osipov et al.’s approach proposed a physics-based method. Both approaches approximate mass attenuation coefficients of materials as a linear combination of basis functions (eigen effects) or physics-based equations. A set of coefficients {a1, a2, a3} or {B, D} were found by parameter optimization in EXCEL Solver. The identification parameters, {a2/a1, a3/a1} or estimated effective atomic number Z from {B, D}, were calculated to identify material of an aluminum 8 step wedge and a steel 8 step wedge in X-ray radiography images taken by a DRCT system. Maitrejean et al.’s approach was unable to provide reliable a3/a1 ratio values for identification of materials. Osipov et al.’s approach was found to be more robust in identify materials with a semi-empirical formula derived from test results in this study.
- 12 October 2021
- Published by Office of Scientific and Technical Information (OSTI)
Material Identification Using Dual Energy X-ray Absorptiometry
Two implementations of dual energy X-ray absorptiometry were studied to identify materials using X-ray attenuation data taken with the Digital Radiography and Computed Tomography (DRCT) systems that were developed for the Recovered Chemical Materiel Directorate (RCMD). Maitrejean et al.’s approach utilizes eigen effects through Principal Component Analysis, while Osipov et al.’s approach proposed a physics-based method. Both approaches approximate mass attenuation coefficients of materials as a linear combination of basis functions (eigen effects) or physics-based equations. A set of coefficients {a1, a2, a3} or {B, D} were found by parameter optimization in EXCEL Solver. The identification parameters, {a2/a1, a3/a1} or estimated effective atomic number Z from {B, D}, were calculated to identify material of an aluminum 8 step wedge and a steel 8 step wedge in X-ray radiography images taken by a DRCT system. Maitrejean et al.’s approach was unable to provide reliable a3/a1 ratio values for identification of materials. Osipov et al.’s approach was found to be more robust in identify materials with a semi-empirical formula derived from test results in this study.
- 7 April 2020
- Published by Office of Scientific and Technical Information (OSTI)
Application of Gaussian Bayes classifier to differentiate chlorine-based chemical agents
The U.S. Department of Energy's Office of Scientific and Technical Information
- 7 April 2020
- Published by Office of Scientific and Technical Information (OSTI)
Application of Gaussian Bayes classifier to differentiate chlorine-based chemical agents
The U.S. Department of Energy's Office of Scientific and Technical Information
- 24 September 2019
- Published by Office of Scientific and Technical Information (OSTI)
Application of artificial neural network to prompt gamma neutron activation analysis for chemical warfare agents identification
The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector, and gamma-ray peak analysis provides input to its chemical identification logic with a probabilistic decision tree (PDT). The effectiveness of the chemical identification algorithm is determined by the availability of a wide range of data to train the algorithm to identify chemical-fills with accuracy. INL has a collection of gamma-ray spectra of various chemical-fills from the field-deployed PINS systems over the years, and it was envisaged to leverage such a database with the Artificial Neural Network (ANN) technique. Therefore, an ANN-based chemical identification algorithm was developed as an independent verification of the current algorithm. The ANN-based algorithm’s performance was evaluated against the U.S. Army blind test data, and results were presented and discussed in this study.
- 24 September 2019
- Published by Office of Scientific and Technical Information (OSTI)
Application of artificial neural network to prompt gamma neutron activation analysis for chemical warfare agents identification
The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector, and gamma-ray peak analysis provides input to its chemical identification logic with a probabilistic decision tree (PDT). The effectiveness of the chemical identification algorithm is determined by the availability of a wide range of data to train the algorithm to identify chemical-fills with accuracy. INL has a collection of gamma-ray spectra of various chemical-fills from the field-deployed PINS systems over the years, and it was envisaged to leverage such a database with the Artificial Neural Network (ANN) technique. Therefore, an ANN-based chemical identification algorithm was developed as an independent verification of the current algorithm. The ANN-based algorithm’s performance was evaluated against the U.S. Army blind test data, and results were presented and discussed in this study.
- 29 May 2019
- Published by Office of Scientific and Technical Information (OSTI)
Determination of the Deuterium-Tritium (D-T) Generator Neutron Flux using Multi-foil Neutron Activation Analysis Method
The deuterium-tritium (D-T) neutron flux from a Thermo-Fisher™ MP320 neutron generator was determined experimentally in this study. Fast neutron flux from a neutron generator can be measured indirectly using multi-foil activation analysis. Two sets of 12 activation foils each were prepared to cover a broad energy range of fast neutrons (1 – 15 MeV), and spectral peak analysis was performed on each activated foil with a mechanically-cooled HPGe detector. A non-negative solution of a linear least squares problem was solved to find a neutron flux energy distribution. The neutron yields of the high-yield (60 µA-90 kV) and low-yield (30 µA-70 kV) settings were determined to be 1.73×108 n/s and 2.28×107 n/s, respectively. Uncertainties on these neutron yields were estimated using the BC400 scintillator count rates whose fluctuations throughout the irradiations were described by the standard deviations of 10.6 and 8.5%, respectively. Linear relationships between the MP320’s neutron flux and a BC400 scintillator as well as a SWENDI-2 neutron dose meter were also derived to utilize them as on-line neutron flux monitors in the future.
- 29 May 2019
- Published by Office of Scientific and Technical Information (OSTI)
Determination of the Deuterium-Tritium (D-T) Generator Neutron Flux using Multi-foil Neutron Activation Analysis Method
The deuterium-tritium (D-T) neutron flux from a Thermo-Fisher™ MP320 neutron generator was determined experimentally in this study. Fast neutron flux from a neutron generator can be measured indirectly using multi-foil activation analysis. Two sets of 12 activation foils each were prepared to cover a broad energy range of fast neutrons (1 – 15 MeV), and spectral peak analysis was performed on each activated foil with a mechanically-cooled HPGe detector. A non-negative solution of a linear least squares problem was solved to find a neutron flux energy distribution. The neutron yields of the high-yield (60 µA-90 kV) and low-yield (30 µA-70 kV) settings were determined to be 1.73×108 n/s and 2.28×107 n/s, respectively. Uncertainties on these neutron yields were estimated using the BC400 scintillator count rates whose fluctuations throughout the irradiations were described by the standard deviations of 10.6 and 8.5%, respectively. Linear relationships between the MP320’s neutron flux and a BC400 scintillator as well as a SWENDI-2 neutron dose meter were also derived to utilize them as on-line neutron flux monitors in the future.
- 1 April 2019
- Published by Office of Scientific and Technical Information (OSTI)
Experimental Validation of MCNP Models for PINS Shadow Shield Mockups
MCNP has been regarded as an indispensable tool in development of radiation detection systems, and it is cost effective, thanks to advances in computing power, to simulate various conceptual designs without even fabricating them. Development of various PINS systems have also benefited from MCNP modeling and simulation. MCNP models of PINS systems have been frequently used to understand detector responses and to fill the gap in experimental data. Recently, a backpack version PINS system was announced to be developed. When the neutron generator and the HPGe detector are built by external vendors, the shadow shield is the component to be designed to maximize the performance while meeting the sponsor’s requirements. In order to utilize MCNP modeling and simulation to find the best specification of the shadow shield, a campaign of PINS lab measurements with a few shadow shield mockups has been conducted to validate MCNP simulation results. This study is intended to validate MCNP simulations and models in preparation of another more extensive simulation study. Validation of neutron flux is also discussed later in this report even though neutron counts were not measured experimentally.
- 1 April 2019
- Published by Office of Scientific and Technical Information (OSTI)
Experimental Validation of MCNP Models for PINS Shadow Shield Mockups
MCNP has been regarded as an indispensable tool in development of radiation detection systems, and it is cost effective, thanks to advances in computing power, to simulate various conceptual designs without even fabricating them. Development of various PINS systems have also benefited from MCNP modeling and simulation. MCNP models of PINS systems have been frequently used to understand detector responses and to fill the gap in experimental data. Recently, a backpack version PINS system was announced to be developed. When the neutron generator and the HPGe detector are built by external vendors, the shadow shield is the component to be designed to maximize the performance while meeting the sponsor’s requirements. In order to utilize MCNP modeling and simulation to find the best specification of the shadow shield, a campaign of PINS lab measurements with a few shadow shield mockups has been conducted to validate MCNP simulation results. This study is intended to validate MCNP simulations and models in preparation of another more extensive simulation study. Validation of neutron flux is also discussed later in this report even though neutron counts were not measured experimentally.