Yuanjun Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuanjun Wang has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Yu Liu
Department of Radiology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 639 Zhizaoju Road, Huangpu District, Shanghai, 200011, China
6 shared publications- Yu Liu
Department of radiology, Shanghai Ninth People’s Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
4 shared publications Peipei Wang
School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Yangpu District, Shanghai, 200093, Shanghai, China
3 shared publicationsYu Wang
School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China
3 shared publicationsFan Jiang
Institute of Medical Imaging and Engineering, University of Shanghai for Science and Technology, Shanghai, China
2 shared publicationsJianglin He
2 shared publications
Latest Publications
- 30 October 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (21) , 215004
Adaptive physics-inspired angular-spatial modeling for multi-shell diffusion MRI denoising
Objective . Multi-shell diffusion magnetic resonance imaging (dMRI) provides rich q-space information but is susceptible to noise, which can disrupt spatial anatomy, intra-shell directional relationships, inter-shell signal attenuation, and downstream diffusion parameter estimation. We aim to develop a denoising method that jointly preserves spatial structure, directional information, and shell-specific signal characteristics. Approach . We propose ASD-NCSM, an adaptive physics-inspired angular-spatial framework with a fixed three-stage alternating architecture. It combines intra-shell differential angular graph message passing with 2.5D spatial residual refinement. Noise-Conditioned Shell Modulation (NCSM) adaptively regulates angular updates according to b -value, spatial residual and angular dispersion proxies, and local gating. A Shell-wise Physical Attenuation and Angular Relation Consistency objective further constrains shell-wise signal fidelity, logarithmic attenuation, and local angular structure. The model was evaluated on Human Connectome Project multi-shell dMRI with simulated noise and independently acquired real in vivo brain dMRI data. Main results . Across five simulated noise levels from 2% to 10%, ASD-NCSM achieved the best overall DWI restoration among MPPCA, 1D-CNN, ECDM, SAN2N, and dMRI-Swin, with consistent subject-level advantages in PSNR, SSIM, and NRMSE. At 6% noise, principal-direction angular nRMSE was 32.68 ± 2.76%, with significant differences from all five baselines after Holm correction. ASD-NCSM also achieved the lowest mean MAE for FA, MD, AD, and RD, and the lowest relative MAE for ODI and FISO, while NDI was comparable to 1D-CNN and dMRI-Swin. For real data without noise-free references, Q-PEFT yielded the lowest angular cross-fit inconsistency (2.29 ± 0.10%) across three test subjects while maintaining limited signal and downstream-parameter changes. Significance. ASD-NCSM jointly preserves spatial continuity, directional geometry, and shell-level attenuation, providing balanced signal recovery, directional preservation, and downstream parameter stability for multi-shell dMRI denoising.
- 30 October 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (21) , 215004
Adaptive physics-inspired angular-spatial modeling for multi-shell diffusion MRI denoising
Objective . Multi-shell diffusion magnetic resonance imaging (dMRI) provides rich q-space information but is susceptible to noise, which can disrupt spatial anatomy, intra-shell directional relationships, inter-shell signal attenuation, and downstream diffusion parameter estimation. We aim to develop a denoising method that jointly preserves spatial structure, directional information, and shell-specific signal characteristics. Approach . We propose ASD-NCSM, an adaptive physics-inspired angular-spatial framework with a fixed three-stage alternating architecture. It combines intra-shell differential angular graph message passing with 2.5D spatial residual refinement. Noise-Conditioned Shell Modulation (NCSM) adaptively regulates angular updates according to b -value, spatial residual and angular dispersion proxies, and local gating. A Shell-wise Physical Attenuation and Angular Relation Consistency objective further constrains shell-wise signal fidelity, logarithmic attenuation, and local angular structure. The model was evaluated on Human Connectome Project multi-shell dMRI with simulated noise and independently acquired real in vivo brain dMRI data. Main results . Across five simulated noise levels from 2% to 10%, ASD-NCSM achieved the best overall DWI restoration among MPPCA, 1D-CNN, ECDM, SAN2N, and dMRI-Swin, with consistent subject-level advantages in PSNR, SSIM, and NRMSE. At 6% noise, principal-direction angular nRMSE was 32.68 ± 2.76%, with significant differences from all five baselines after Holm correction. ASD-NCSM also achieved the lowest mean MAE for FA, MD, AD, and RD, and the lowest relative MAE for ODI and FISO, while NDI was comparable to 1D-CNN and dMRI-Swin. For real data without noise-free references, Q-PEFT yielded the lowest angular cross-fit inconsistency (2.29 ± 0.10%) across three test subjects while maintaining limited signal and downstream-parameter changes. Significance. ASD-NCSM jointly preserves spatial continuity, directional geometry, and shell-level attenuation, providing balanced signal recovery, directional preservation, and downstream parameter stability for multi-shell dMRI denoising.
- 12 June 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (3) , 1055-1067
CDSegNet: a multi-scale convolution and attention mechanism U-shaped network for Crohn’s disease lesion segmentation
Accurate segmentation of Crohn's disease (CD) lesions from computed tomography enterography (CTE) cross-sectional images is crucial for diagnosing CD patients and may assist in developing a personalized treatment plan. However, to the best of our knowledge, studies on automatic CD lesion segmentation remain limited. This paper proposes a novel model (named CDSegNet) based on the U-Net to improve the segmentation of CD lesions. The model integrates a residual dilated and standard convolution feature extract (RDCFE) module to enhance fine-grained and global feature extraction while preserving information flow. Furthermore, a residual attention feature extraction (RAFE) module is introduced in the decoder to refine features and sharpen ambiguous lesion boundaries. In addition, a multi-scale convolution module is designed to aggregate features from different receptive fields to improve robustness across varying lesion sizes. Finally, Intersection over Union (IoU), Recall, Dice Similarity Coefficient (DSC), and Hausdorff distance (HD) are employed to quantitatively assess the model performance. The Recall, IoU, HD, and DSC of the CDSegNet are 0.867, 0.820, 23.28, and 0.895, respectively. Compared to the baseline model U-Net on our dataset, the IoU, HD, and DSC improve by 11.6%, 3.21, and 10.4%, respectively. Experiment results demonstrate that CDSegNet exhibits competitive performance under the current experimental setting, with particular strengths in segmenting small and medium lesions and achieving stable segmentation across all test images. However, further validation is needed prior to clinical application.
- 12 June 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (3) , 1055-1067
CDSegNet: a multi-scale convolution and attention mechanism U-shaped network for Crohn’s disease lesion segmentation
Accurate segmentation of Crohn's disease (CD) lesions from computed tomography enterography (CTE) cross-sectional images is crucial for diagnosing CD patients and may assist in developing a personalized treatment plan. However, to the best of our knowledge, studies on automatic CD lesion segmentation remain limited. This paper proposes a novel model (named CDSegNet) based on the U-Net to improve the segmentation of CD lesions. The model integrates a residual dilated and standard convolution feature extract (RDCFE) module to enhance fine-grained and global feature extraction while preserving information flow. Furthermore, a residual attention feature extraction (RAFE) module is introduced in the decoder to refine features and sharpen ambiguous lesion boundaries. In addition, a multi-scale convolution module is designed to aggregate features from different receptive fields to improve robustness across varying lesion sizes. Finally, Intersection over Union (IoU), Recall, Dice Similarity Coefficient (DSC), and Hausdorff distance (HD) are employed to quantitatively assess the model performance. The Recall, IoU, HD, and DSC of the CDSegNet are 0.867, 0.820, 23.28, and 0.895, respectively. Compared to the baseline model U-Net on our dataset, the IoU, HD, and DSC improve by 11.6%, 3.21, and 10.4%, respectively. Experiment results demonstrate that CDSegNet exhibits competitive performance under the current experimental setting, with particular strengths in segmenting small and medium lesions and achieving stable segmentation across all test images. However, further validation is needed prior to clinical application.
- 26 May 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Automatic Localization and Classification of Crohn’s Disease Activity in Computed Tomography Enterography Images Using Deep Learning
Rapid and accurate localization and activity grading of Crohn's disease (CD) lesions on computed tomography enterography (CTE) images enhance the diagnostic efficiency of radiologists. We developed a one-stage model (called CD-YOLO) based on YOLOv5 for the automatic detection and classification of CD lesions. To tackle the challenges of variable sizes and shapes, and boundary blurring in CD lesions, we integrated a suite of specialized modules that not only enhanced the model's feature extraction capability but also enabled the effective fusion of multi-scale features. We retrospectively collected CTE images from 233 patients with pathologically and endoscopically confirmed CD. Patients were divided into training, validation, and testing cohorts at the patient level. The model performance was evaluated using the mAP@0.5, precision, and recall. Gradient-weighted class activation mapping (Grad-CAM) was employed to interpret the model predictions via visualization. The mAP@0.5 of CD-YOLO for detecting active and remission CD was 92.1% and 84.2%, respectively. Compared to YOLOv5s, the mAP@0.5 improved by 2.0% and 4.9% in detecting active and remission CD, respectively. Meanwhile, the missed detection and misdetection lesion rates decreased by 4.9% and 4.18%, respectively. The proposed CD-YOLO framework demonstrated superior performance in CD lesion localization and activity classification and may serve as an effective computer-aided diagnostic tool to support radiologists and gastroenterologists, as well as facilitate clinical teaching.
- 26 May 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Automatic Localization and Classification of Crohn’s Disease Activity in Computed Tomography Enterography Images Using Deep Learning
Rapid and accurate localization and activity grading of Crohn's disease (CD) lesions on computed tomography enterography (CTE) images enhance the diagnostic efficiency of radiologists. We developed a one-stage model (called CD-YOLO) based on YOLOv5 for the automatic detection and classification of CD lesions. To tackle the challenges of variable sizes and shapes, and boundary blurring in CD lesions, we integrated a suite of specialized modules that not only enhanced the model's feature extraction capability but also enabled the effective fusion of multi-scale features. We retrospectively collected CTE images from 233 patients with pathologically and endoscopically confirmed CD. Patients were divided into training, validation, and testing cohorts at the patient level. The model performance was evaluated using the mAP@0.5, precision, and recall. Gradient-weighted class activation mapping (Grad-CAM) was employed to interpret the model predictions via visualization. The mAP@0.5 of CD-YOLO for detecting active and remission CD was 92.1% and 84.2%, respectively. Compared to YOLOv5s, the mAP@0.5 improved by 2.0% and 4.9% in detecting active and remission CD, respectively. Meanwhile, the missed detection and misdetection lesion rates decreased by 4.9% and 4.18%, respectively. The proposed CD-YOLO framework demonstrated superior performance in CD lesion localization and activity classification and may serve as an effective computer-aided diagnostic tool to support radiologists and gastroenterologists, as well as facilitate clinical teaching.
- Open Access
- 14 April 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (4) , 459
Ureteral Orifice Detection in Ureteroscopic Images Based on Large-Kernel Convolutional Neural Networks and Attention-Based Feature Fusion
Objective: To enhance the information modeling capacity of large-kernel convolutional neural networks and to build a ureteral orifice detection framework for ureteroscopic imaging. Methods: A retrospective dataset of ureteroscopic images from 222 patients was collected. The patients were randomly divided into training and testing sets at a ratio of 7:3. Initially, video files were converted into image frames, and feature-relevant images were manually labeled by physicians. Subsequently, a ConvNeXt-based backbone augmented with squeeze-and-excitation (SE) modules was employed to extract diverse deep features. SCConv modules were incorporated across stages to strengthen the network’s feature extraction performance. Lastly, enhanced spatial excitation attention mechanisms were cascaded to achieve superior feature fusion and detection accuracy. Comparative experiments were conducted against baseline models, including ConvNeXt, assessing accuracy, computational overhead, and inference latency. Results: On a test set of 491 ureteroscopic images, all models achieved mAP@50 values above 0.75, whereas the proposed network achieved 0.890, markedly exceeding baseline performance. The model operated at 20 ms per frame, achieving a frame rate of 50 FPS. Conclusions: We developed an improved deep learning framework based on large-kernel convolutional networks for real-time ureteral orifice detection in endoscopic scenarios. This system achieves a favorable balance between detection accuracy and real-time efficiency. The method demonstrates significant potential as a training and feedback tool for residents and junior urologists in clinical environments.
- 14 April 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (4) , 459
Open AccessUreteral Orifice Detection in Ureteroscopic Images Based on Large-Kernel Convolutional Neural Networks and Attention-Based Feature Fusion
Objective: To enhance the information modeling capacity of large-kernel convolutional neural networks and to build a ureteral orifice detection framework for ureteroscopic imaging. Methods: A retrospective dataset of ureteroscopic images from 222 patients was collected. The patients were randomly divided into training and testing sets at a ratio of 7:3. Initially, video files were converted into image frames, and feature-relevant images were manually labeled by physicians. Subsequently, a ConvNeXt-based backbone augmented with squeeze-and-excitation (SE) modules was employed to extract diverse deep features. SCConv modules were incorporated across stages to strengthen the network’s feature extraction performance. Lastly, enhanced spatial excitation attention mechanisms were cascaded to achieve superior feature fusion and detection accuracy. Comparative experiments were conducted against baseline models, including ConvNeXt, assessing accuracy, computational overhead, and inference latency. Results: On a test set of 491 ureteroscopic images, all models achieved mAP@50 values above 0.75, whereas the proposed network achieved 0.890, markedly exceeding baseline performance. The model operated at 20 ms per frame, achieving a frame rate of 50 FPS. Conclusions: We developed an improved deep learning framework based on large-kernel convolutional networks for real-time ureteral orifice detection in endoscopic scenarios. This system achieves a favorable balance between detection accuracy and real-time efficiency. The method demonstrates significant potential as a training and feedback tool for residents and junior urologists in clinical environments.
- 8 April 2026
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 432, 110769
Frequency-enhanced fiber orientation distribution super-resolution network with application on Alzheimer's disease
- 8 April 2026
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 432, 110769
Frequency-enhanced fiber orientation distribution super-resolution network with application on Alzheimer's disease
- 4 February 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (3) , 1179-1198
3DFE-Net: Three-dimensional fusion enhancement network based on multi-attention mechanism for multi-modal magnetic resonance images
Nowadays, the research of image fusion methods focuses on two-dimensional medical images, and almost no three-dimensional medical image fusion methods based on deep learning have been proposed. However, 3D image fusion is significant in clinical diagnosis. Therefore, this paper proposed a 3D medical image fusion enhancement network (3DFE-Net) for the gap in deep learning. 3DFE-Net included a feature extraction module, a multi-attention fusion module, and a feature reconstruction module. Firstly, multi-receptive field convolution blocks (MRFC) and multi-receptive field bottleneck blocks (MRFB) were devised instead of the traditional convolutional blocks to extract features of multiple receptive fields. Then, the multi-attention fusion module was designed using channel attention, self-attention, and spatial attention to make the network focus on the critical information in source images. Finally, the 3D fused image was obtained by the feature reconstruction module. In addition, a multivariate loss function was proposed for network training so that the fused image retains more edge structural information and texture details. MR-T1ce/MR-T2 fusion experiments show that, compared with the traditional method, 3DFE-Net improved the evaluation metrics EN (Information Entropy), MI (Mutual Information), SD (Standard Deviation), Qabf (Quality assessment of binary), and VIF (Visual Information Fidelity) by 0.0501, 0.1003, 5.2682, 0.1874, and 0.2129, respectively. 3DFE-Net can focus on the glioma lesion region in glioma slice fusion to achieve outstanding results and keep the structural information in MR-T1ce and the brightness information in MR-T2 well in normal slices. In qualitative and quantitative evaluations, 3DFE-Net performs better than conventional methods. Graphical abstract
- 4 February 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (3) , 1179-1198
3DFE-Net: Three-dimensional fusion enhancement network based on multi-attention mechanism for multi-modal magnetic resonance images
Nowadays, the research of image fusion methods focuses on two-dimensional medical images, and almost no three-dimensional medical image fusion methods based on deep learning have been proposed. However, 3D image fusion is significant in clinical diagnosis. Therefore, this paper proposed a 3D medical image fusion enhancement network (3DFE-Net) for the gap in deep learning. 3DFE-Net included a feature extraction module, a multi-attention fusion module, and a feature reconstruction module. Firstly, multi-receptive field convolution blocks (MRFC) and multi-receptive field bottleneck blocks (MRFB) were devised instead of the traditional convolutional blocks to extract features of multiple receptive fields. Then, the multi-attention fusion module was designed using channel attention, self-attention, and spatial attention to make the network focus on the critical information in source images. Finally, the 3D fused image was obtained by the feature reconstruction module. In addition, a multivariate loss function was proposed for network training so that the fused image retains more edge structural information and texture details. MR-T1ce/MR-T2 fusion experiments show that, compared with the traditional method, 3DFE-Net improved the evaluation metrics EN (Information Entropy), MI (Mutual Information), SD (Standard Deviation), Qabf (Quality assessment of binary), and VIF (Visual Information Fidelity) by 0.0501, 0.1003, 5.2682, 0.1874, and 0.2129, respectively. 3DFE-Net can focus on the glioma lesion region in glioma slice fusion to achieve outstanding results and keep the structural information in MR-T1ce and the brightness information in MR-T2 well in normal slices. In qualitative and quantitative evaluations, 3DFE-Net performs better than conventional methods. Graphical abstract
- 12 November 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (2) , 649-668
A deep learning-based MRI automatic detection model for spinal schwannoma and meningioma
Schwannomas (SCH) and meningiomas (MEN), the two most common primary spinal cord tumors, present a clinical diagnostic challenge due to their overlapping clinical and radiological manifestations. To address this, we developed a deep learning-based object detection model for automated detection of these tumors using magnetic resonance imaging (MRI), which could facilitate early diagnosis and alleviate clinical decision-making burdens. Our study retrospectively analyzed MRI scans from 103 pathologically confirmed SCH and MEN cases at a local hospital (July 2015-August 2024). First, we took YOLOv8n as the baseline model, introduced selective kernel fusion (SKFusion) module to replace the feature fusion layer of the original neck part, added recursive gated convolution (gnConv), and then trained the improved feature fusion model (YOLOv8n-SKNeck). The proposed model achieved notable performance metrics: 91.20% mean accuracy, 90.92% mean recall, and 91.03% mean F1-score for SCH/MEN detection. These results demonstrate that our optimized deep learning framework can effectively automate the detection and differential diagnosis of spinal SCH and MEN through MRI analysis. Thus, the novel method holds significant potential for advancing computer-aided diagnosis and facilitating innovative applications in future clinical practice. Graphical abstract
- 12 November 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (2) , 649-668
A deep learning-based MRI automatic detection model for spinal schwannoma and meningioma
Schwannomas (SCH) and meningiomas (MEN), the two most common primary spinal cord tumors, present a clinical diagnostic challenge due to their overlapping clinical and radiological manifestations. To address this, we developed a deep learning-based object detection model for automated detection of these tumors using magnetic resonance imaging (MRI), which could facilitate early diagnosis and alleviate clinical decision-making burdens. Our study retrospectively analyzed MRI scans from 103 pathologically confirmed SCH and MEN cases at a local hospital (July 2015-August 2024). First, we took YOLOv8n as the baseline model, introduced selective kernel fusion (SKFusion) module to replace the feature fusion layer of the original neck part, added recursive gated convolution (gnConv), and then trained the improved feature fusion model (YOLOv8n-SKNeck). The proposed model achieved notable performance metrics: 91.20% mean accuracy, 90.92% mean recall, and 91.03% mean F1-score for SCH/MEN detection. These results demonstrate that our optimized deep learning framework can effectively automate the detection and differential diagnosis of spinal SCH and MEN through MRI analysis. Thus, the novel method holds significant potential for advancing computer-aided diagnosis and facilitating innovative applications in future clinical practice. Graphical abstract
- 2 July 2025
- Published by Elsevier in Academic Radiology
- Vol. 32 (11) , 6579-6590
Prediction Crohn's Disease Activity Using Computed Tomography Enterography-Based Radiomics and Serum Markers
- 2 July 2025
- Published by Elsevier in Academic Radiology
- Vol. 32 (11) , 6579-6590
Prediction Crohn's Disease Activity Using Computed Tomography Enterography-Based Radiomics and Serum Markers
- 23 June 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1173) , 1446-1455
A novel clinical radiomics nomogram to predict disease activity in Crohn’s disease
Objective: To develop and validate a novel CT enterography (CTE)-based radiomics nomogram for predicting disease activity in Crohn’s disease (CD). Methods: The CTE images and clinical data of 133 CD patients were retrospectively collected. The CTE-based radiomics features were extracted and screened by t-test and least absolute shrinkage and selection operator regression algorithm. Significant clinical variables were identified by multifactor logistic regression analysis. Then a combined model of clinical and radiomics features was established by multifactorial logistic regression, and a nomogram was plotted. Results: 11 and 16 best radiomics features were screened based on CTE venous phase and arterial phase images, respectively. The area under ROC curve (AUC) of the venous radiomics model was higher than that of the arterial radiomics model on both the training and test sets (0.948 vs 0.927, 0.915 vs 0.878). Venous CT value, erythrocyte sedimentation rate and C-reactive protein were clinically relevant independent predictors of CD activity, and the AUC of the clinical model constructed from the 3 predictors was 0.873 and 0.822 on the training set and test set, respectively. The combined model had AUCs of 0.968 and 0.944 on the training and test sets, respectively. And the accuracy, sensitivity, and specificity were 0.900, 0.913, and 0.882 on the test set, respectively, which were higher than the other models. Conclusions: We develop a novel clinical radiomics nomogram to predict CD activity, which can assist clinicians in individualized treatment. Advances in knowledge: This study is a novel attempt to establish a combined clinical-imaging graph model to predict the CD activity.
- 23 June 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1173) , 1446-1455
A novel clinical radiomics nomogram to predict disease activity in Crohn’s disease
Objective: To develop and validate a novel CT enterography (CTE)-based radiomics nomogram for predicting disease activity in Crohn’s disease (CD). Methods: The CTE images and clinical data of 133 CD patients were retrospectively collected. The CTE-based radiomics features were extracted and screened by t-test and least absolute shrinkage and selection operator regression algorithm. Significant clinical variables were identified by multifactor logistic regression analysis. Then a combined model of clinical and radiomics features was established by multifactorial logistic regression, and a nomogram was plotted. Results: 11 and 16 best radiomics features were screened based on CTE venous phase and arterial phase images, respectively. The area under ROC curve (AUC) of the venous radiomics model was higher than that of the arterial radiomics model on both the training and test sets (0.948 vs 0.927, 0.915 vs 0.878). Venous CT value, erythrocyte sedimentation rate and C-reactive protein were clinically relevant independent predictors of CD activity, and the AUC of the clinical model constructed from the 3 predictors was 0.873 and 0.822 on the training set and test set, respectively. The combined model had AUCs of 0.968 and 0.944 on the training and test sets, respectively. And the accuracy, sensitivity, and specificity were 0.900, 0.913, and 0.882 on the test set, respectively, which were higher than the other models. Conclusions: We develop a novel clinical radiomics nomogram to predict CD activity, which can assist clinicians in individualized treatment. Advances in knowledge: This study is a novel attempt to establish a combined clinical-imaging graph model to predict the CD activity.