Yu Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu Liu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Yuanjun Wang
University of Shanghai for Science and Technology
4 shared publications Fan Jiang
Institute of Medical Imaging and Engineering, University of Shanghai for Science and Technology, Shanghai, China
2 shared publications- Kaicheng Li
Department of Radiology, Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, China
1 shared publication Min Liu
Department of CT, The People's Hospital of Xiang Yun, Bai Autonomous Region, Dali, Yunnan, China
1 shared publicationWei Li
School of Health Science and Engineering, University of Shanghai for Science and Technology , Shanghai 200093, China
1 shared publicationXiaona Liu
Yantai Affiliated Hospital of Binzhou Medical University, Shandong, China
1 shared publication
Latest Publications
- Open Access
- 22 March 2024
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 53 (5) , 296-307
DMAF-Net: deformable multi-scale adaptive fusion network for dental structure detection with panoramic radiographs
Panoramic radiography is one of the most commonly used diagnostic modalities in dentistry. Automatic recognition of panoramic radiography helps dentists in decision support. In order to improve the accuracy of the detection of dental structural problems in panoramic radiographs, we have improved the YOLO network and verified the feasibility of this new method in aiding the detection of dental problems. We propose a Deformable Multi-scale Adaptive Fusion Net (DMAF-Net) to detect five types of dental situations (impacted teeth, missing teeth, implants, crown restorations and root canal-treated teeth) in panoramic radiography by improving the You Only Look Once (YOLO) network. In DMAF-Net, we propose different modules to enhance the feature extraction capability of the network as well as to acquire high-level features at different scales, while using adaptive spatial feature fusion to solve the problem of scale mismatches of different feature layers, which effectively improves the detection performance. In order to evaluate the detection performance of the models, we compare the experimental results of different models in the test set, and select the optimal results of the models by calculating the average of different metrics in each category as the evaluation criteria. 1474 panoramic radiographs were divided into training, validation and test sets in the ratio of 7:2:1. In the test set, the average precision and recall of DMAF-Net are 92.7% and 87.6%, respectively; the mean Average Precision (mAP0.5 and mAP [0.5:0.95]) are 91.8% and 63.7%, respectively. The proposed DMAF-Net model improves existing deep learning models and achieves automatic detection of tooth structure problems in panoramic radiographs. This new method has great potential for new computer-aided diagnostic, teaching and clinical applications in the future.
- 22 March 2024
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 53 (5) , 296-307
Open AccessDMAF-Net: deformable multi-scale adaptive fusion network for dental structure detection with panoramic radiographs
Panoramic radiography is one of the most commonly used diagnostic modalities in dentistry. Automatic recognition of panoramic radiography helps dentists in decision support. In order to improve the accuracy of the detection of dental structural problems in panoramic radiographs, we have improved the YOLO network and verified the feasibility of this new method in aiding the detection of dental problems. We propose a Deformable Multi-scale Adaptive Fusion Net (DMAF-Net) to detect five types of dental situations (impacted teeth, missing teeth, implants, crown restorations and root canal-treated teeth) in panoramic radiography by improving the You Only Look Once (YOLO) network. In DMAF-Net, we propose different modules to enhance the feature extraction capability of the network as well as to acquire high-level features at different scales, while using adaptive spatial feature fusion to solve the problem of scale mismatches of different feature layers, which effectively improves the detection performance. In order to evaluate the detection performance of the models, we compare the experimental results of different models in the test set, and select the optimal results of the models by calculating the average of different metrics in each category as the evaluation criteria. 1474 panoramic radiographs were divided into training, validation and test sets in the ratio of 7:2:1. In the test set, the average precision and recall of DMAF-Net are 92.7% and 87.6%, respectively; the mean Average Precision (mAP0.5 and mAP [0.5:0.95]) are 91.8% and 63.7%, respectively. The proposed DMAF-Net model improves existing deep learning models and achieves automatic detection of tooth structure problems in panoramic radiographs. This new method has great potential for new computer-aided diagnostic, teaching and clinical applications in the future.
- 29 November 2021
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 60 (1) , 279-295
Spectrum-sine interpolation framework for DTI processing
Diffusion tensor imaging (DTI) data interpolation is important for DTI processing, which could affect the precision and computational complexity in the process of denoising, filtering, regularization, and DTI registration and fiber tracking. In this paper, we propose a novel DTI interpolation framework named with spectrum-sine (SS) focusing on tensor orientation variation in DTI processing. Compared with the state-of-the-art DTI interpolation method using Euler angles or quaternion to represent the orientation of DTI tensors, this method does not need to convert eigenvectors into Euler angles or quaternions, but interpolates each tensor’s unit eigenvector directly. The prominent merit of this tensor interpolation method lies in tensor orientation information preservation, which is different from the existing DTI tensor interpolation methods that interpolating tensor’s orientation information in a scalar way. The experimental results from both synthetic and real human brain DTI data demonstrated the proposed SS interpolation scheme not only maintains the advantages of Log-Euclidean and Riemannian interpolation frameworks, such as preserving the tensor’s symmetric positive definiteness and the monotonic determinant variation, but also preserve the tensor’s anisotropy property which was proposed in the spectral quaternion (SQ) method. Graphical abstract
- 29 November 2021
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 60 (1) , 279-295
Spectrum-sine interpolation framework for DTI processing
Diffusion tensor imaging (DTI) data interpolation is important for DTI processing, which could affect the precision and computational complexity in the process of denoising, filtering, regularization, and DTI registration and fiber tracking. In this paper, we propose a novel DTI interpolation framework named with spectrum-sine (SS) focusing on tensor orientation variation in DTI processing. Compared with the state-of-the-art DTI interpolation method using Euler angles or quaternion to represent the orientation of DTI tensors, this method does not need to convert eigenvectors into Euler angles or quaternions, but interpolates each tensor’s unit eigenvector directly. The prominent merit of this tensor interpolation method lies in tensor orientation information preservation, which is different from the existing DTI tensor interpolation methods that interpolating tensor’s orientation information in a scalar way. The experimental results from both synthetic and real human brain DTI data demonstrated the proposed SS interpolation scheme not only maintains the advantages of Log-Euclidean and Riemannian interpolation frameworks, such as preserving the tensor’s symmetric positive definiteness and the monotonic determinant variation, but also preserve the tensor’s anisotropy property which was proposed in the spectral quaternion (SQ) method. Graphical abstract
- 10 July 2020
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 58 (9) , 2083-2093
Reference-free brain template construction with population symmetric registration
Population registration has been proposed for normalizing a large group of images into a common space, which is important in many clinical and research studies, such as brain development, aging, and atlas construction. Different from pairwise registration problem that aligns the target image to the reference directly, determining the reference or the hidden common space with the least bias is important in population registration. In order to decrease this bias, a lot of work takes the arithmetic mean image as the reference. However, the arithmetic mean image is usually too smooth to guide the population registration. This work presents an efficient symmetric population registration strategy for brain template construction, which defines the symmetric population center guiding population registration. This is important because the population registration problem can be translated into a series of pairwise registration problem which is easier to optimize and implement. Another prominent merit of proposed population registration algorithm is reference-free, which eliminates the reference dependency–related bias in population registration. Based on this symmetric population registration, the brain template is constructed by approximating both the population’s intensity and gradient information. In addition, we also present a new measurement named with average bias for evaluating the unbiasedness of brain template. Experiments were first carried out on four synthetic images created with controllable transforms, which aim at comparing the difference between conventional method and proposed method. Further experiment is designed for reference-free validation. Finally, in real inter-subject brain data, twenty MRI T1 volumes with size 256 × 256 × 176 are used to construct a symmetric brain template with proposed population registration method. The constructed brain template has a small bias and clear brain details comparing with DARTEL.
- 10 July 2020
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 58 (9) , 2083-2093
Reference-free brain template construction with population symmetric registration
Population registration has been proposed for normalizing a large group of images into a common space, which is important in many clinical and research studies, such as brain development, aging, and atlas construction. Different from pairwise registration problem that aligns the target image to the reference directly, determining the reference or the hidden common space with the least bias is important in population registration. In order to decrease this bias, a lot of work takes the arithmetic mean image as the reference. However, the arithmetic mean image is usually too smooth to guide the population registration. This work presents an efficient symmetric population registration strategy for brain template construction, which defines the symmetric population center guiding population registration. This is important because the population registration problem can be translated into a series of pairwise registration problem which is easier to optimize and implement. Another prominent merit of proposed population registration algorithm is reference-free, which eliminates the reference dependency–related bias in population registration. Based on this symmetric population registration, the brain template is constructed by approximating both the population’s intensity and gradient information. In addition, we also present a new measurement named with average bias for evaluating the unbiasedness of brain template. Experiments were first carried out on four synthetic images created with controllable transforms, which aim at comparing the difference between conventional method and proposed method. Further experiment is designed for reference-free validation. Finally, in real inter-subject brain data, twenty MRI T1 volumes with size 256 × 256 × 176 are used to construct a symmetric brain template with proposed population registration method. The constructed brain template has a small bias and clear brain details comparing with DARTEL.
- 1 January 2020
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 49 (1) , 20190277
Solitary plasmacytoma of maxillofacial bones: correlation of CT features with pathological findings
Objective: To explore the CT features of solitary plasmacytoma (SP) of maxillofacial bones and correlation with pathological findings. Methods and materials: We retrospectively reviewed the clinical, CT and pathological features of SP in the maxillofacial bones. 16 patients with clinically and histologically proven SP of maxillofacial bones were involved. They were aged from 27 to 79 years old (median 55.5 years old), and included 12 males and 4 females (males vs females: 3:1). All patients performed CT examination, in whom 13 patients underwent enhanced scanning and 3 plain scanning. The CT images were assessed for lesion location, size (maximum diameter), shape (round, oval and irregular), boundary (defined and illdefined), bone changes (bone destruction, residual bone, sclerotic margin and periosteal reaction), density of soft tissue mass and enhancement manifestations, and invasion of adjacent structures. Results: 13 patients suffered from SP in the mandible, 2 in the zygoma, and 1 in the maxilla and hard palate. The maximum diameter of lesions ranged from 2.4 to 8.2 cm (mean 3.93 ± 1.435 cm). Most lesions were founded as a solitary osteolytic lesions (15/16, 93.75%) with round or ovoid shape (13/16, 81.25%), smooth margin (16/16, 100%) and defined boundary (16/16, 100%) in bone marrow. They destroyed bone cortex (15/16, 93.75%) and had residual bone (10/16, 62.5%), without sclerosis margin (15/16, 93.75%) and periosteal reaction (14/16, 87.5%). They easily formed soft tissue masses (16/16, 100%) and invade adjacent anatomical structures (15/16, 93.75%). The density of lesions was usually uniform (12/16, 75%) with strong enhancement. There was a significant difference in CT values between plain and enhanced scanning [50.75 ± 9.140 Hounfield unit (HU) vs 101.0 ± 28.830 HU; p < 0.001), with the mean difference of CT values 50.25 HU. Conclusions: SP is predominant in the mandible of elderly male patients. A solitary, round or ovoid, well-defined, osteolytic, invasive mass in bone marrow, which destroys bone cortex, has residual bone, no sclerosis margin and periosteal reaction, and shows strong enhancement, is suggestive of this diagnosis.
- 1 January 2020
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 49 (1) , 20190277
Solitary plasmacytoma of maxillofacial bones: correlation of CT features with pathological findings
Objective: To explore the CT features of solitary plasmacytoma (SP) of maxillofacial bones and correlation with pathological findings. Methods and materials: We retrospectively reviewed the clinical, CT and pathological features of SP in the maxillofacial bones. 16 patients with clinically and histologically proven SP of maxillofacial bones were involved. They were aged from 27 to 79 years old (median 55.5 years old), and included 12 males and 4 females (males vs females: 3:1). All patients performed CT examination, in whom 13 patients underwent enhanced scanning and 3 plain scanning. The CT images were assessed for lesion location, size (maximum diameter), shape (round, oval and irregular), boundary (defined and illdefined), bone changes (bone destruction, residual bone, sclerotic margin and periosteal reaction), density of soft tissue mass and enhancement manifestations, and invasion of adjacent structures. Results: 13 patients suffered from SP in the mandible, 2 in the zygoma, and 1 in the maxilla and hard palate. The maximum diameter of lesions ranged from 2.4 to 8.2 cm (mean 3.93 ± 1.435 cm). Most lesions were founded as a solitary osteolytic lesions (15/16, 93.75%) with round or ovoid shape (13/16, 81.25%), smooth margin (16/16, 100%) and defined boundary (16/16, 100%) in bone marrow. They destroyed bone cortex (15/16, 93.75%) and had residual bone (10/16, 62.5%), without sclerosis margin (15/16, 93.75%) and periosteal reaction (14/16, 87.5%). They easily formed soft tissue masses (16/16, 100%) and invade adjacent anatomical structures (15/16, 93.75%). The density of lesions was usually uniform (12/16, 75%) with strong enhancement. There was a significant difference in CT values between plain and enhanced scanning [50.75 ± 9.140 Hounfield unit (HU) vs 101.0 ± 28.830 HU; p < 0.001), with the mean difference of CT values 50.25 HU. Conclusions: SP is predominant in the mandible of elderly male patients. A solitary, round or ovoid, well-defined, osteolytic, invasive mass in bone marrow, which destroys bone cortex, has residual bone, no sclerosis margin and periosteal reaction, and shows strong enhancement, is suggestive of this diagnosis.
- 2 March 2019
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 27 (2) , 307-319
Three-dimensional structure tensor based PET/CT fusion in gradient domain
Gradient based image fusion can more effectively incorporate edge details using structure tensor, which is successfully used in 2D image fusion. In this study, we generalized and applied this gradient based image fusion method into 3D for non-small cell lung cancer PET/CT image fusion. According the characteristic of lung PET/CT images, we proposed a novel 3D structure tensor based feature, which can be used to construct a weighted structure tensor containing important local detail of both PET and CT images. The fusion gradient domain is deduced from a rank one tensor, which is the closest approximation of the weighted structure tensor in geometry. Based on the fusion gradient domain, final PET/CT fusion image is obtained by solving a Poisson equation. Comparing with the wavelet transform based fusion result, the average information entropy and average gradient measure of proposed fusion method increase 13.5% and 42.3%, respectively. The experimental results show that the proposed fusion method enables to effectively preserve lung vessel structure and sphere-like lesion detail while produces clear, stable and well consistent fusion images.
- 2 March 2019
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 27 (2) , 307-319
Three-dimensional structure tensor based PET/CT fusion in gradient domain
Gradient based image fusion can more effectively incorporate edge details using structure tensor, which is successfully used in 2D image fusion. In this study, we generalized and applied this gradient based image fusion method into 3D for non-small cell lung cancer PET/CT image fusion. According the characteristic of lung PET/CT images, we proposed a novel 3D structure tensor based feature, which can be used to construct a weighted structure tensor containing important local detail of both PET and CT images. The fusion gradient domain is deduced from a rank one tensor, which is the closest approximation of the weighted structure tensor in geometry. Based on the fusion gradient domain, final PET/CT fusion image is obtained by solving a Poisson equation. Comparing with the wavelet transform based fusion result, the average information entropy and average gradient measure of proposed fusion method increase 13.5% and 42.3%, respectively. The experimental results show that the proposed fusion method enables to effectively preserve lung vessel structure and sphere-like lesion detail while produces clear, stable and well consistent fusion images.
- 12 October 2018
- Published by Springer Nature in Abdominal Radiology
- Vol. 44 (3) , 950-957
PET/CT in brachytherapy early response evaluation of pancreatic ductal adenocarcinoma xenografts: comparison with apparent diffusion coefficient from diffusion-weighted MR imaging
To evaluate the feasibility of using PET/CT and diffusion-weighted magnetic resonance imaging (DW-MRI) to monitor the early response of pancreatic ductal adenocarcinoma (PDAC) xenografts to brachytherapy, and to determine whether maximum standardized uptake value (SUVmax) correlate with apparent diffusion coefficient (ADC).
- 12 October 2018
- Published by Springer Nature in Abdominal Radiology
- Vol. 44 (3) , 950-957
PET/CT in brachytherapy early response evaluation of pancreatic ductal adenocarcinoma xenografts: comparison with apparent diffusion coefficient from diffusion-weighted MR imaging
To evaluate the feasibility of using PET/CT and diffusion-weighted magnetic resonance imaging (DW-MRI) to monitor the early response of pancreatic ductal adenocarcinoma (PDAC) xenografts to brachytherapy, and to determine whether maximum standardized uptake value (SUVmax) correlate with apparent diffusion coefficient (ADC).