GMGaetano Mileti

Gaetano Mileti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gaetano Mileti has a total of 111 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Mode Suppression and Homogeneous Field Bandwidth Enhancement of a Tuning-Free Micro-Loop-Gap Resonator Using FR4 for Chip-Scale Rubidium Clock

    by Yuanyan Su, Matthieu Pellaton, Christoph Affolderbach, Gaetano Mileti, Anja K. Skrivervik

    We propose strategies for the design of a tuning-free micro-loop-gap resonator ( $\mu$ -LGR) that provides high magnetic field homogeneity of the TE $_{011}$ -like mode over a broad bandwidth with a high field orientation factor (FOF). This broadband feature allows it to fulfill the FOF requirement at the precise 6.835 GHz resonance for chip-scale double-resonance (DR) rubidium (Rb) clocks without the need for any mechanical or electrical frequency tuning means. The FOF bandwidth expansion mechanism manipulates the unwanted side modes by using perturbation theory and distinct properties of the FR4 substrate characterized by an accurate method for the long-term stabilities in high temperatures. Thanks to the absence of tuning components and the usage of lossy FR4, this new $\mu$ -LGR achieves better FOF in a wide bandwidth of $\sim$ 550 MHz and simplifies the physics package (PP) of the entire clock system. The measured $S$ -parameters of the fabricated $\mu $ -LGR prototype and its cavity-cell assembly validate that the cell-loaded $\mu$ -LGR can operate over a 128 MHz impedance bandwidth of $\vert S_{11} \vert < -10$ dB at $\sim$ 109 $^{\circ}$ C, with strong resonance at 6.83 GHz and a loaded quality factor of 12.7 which does not result in reduced signal strength but is advantageous to alleviating cavity pulling for optically detected passive DR Rb clocks. Moreover, a spectroscopic experiment of the developed chip-scale atomic clock (CSAC) based on the proposed $\mu$ -LGR verifies that the tuning-free $\mu$ -LGR can obtain a FOF $_{\text{exp}}$ of 0.75 at 6.835 GHz, therefore guaranteeing the atom transition to be well excited for the clock operation.


  • Open Access

    An additive-manufactured microwave cavity for a compact cold-atom clock

    by Etienne Batori, Alan Bregazzi, Ben Lewis, Paul F. Griffin, Erling Riis, Gaetano Mileti, Christoph Affolderbach

    We present an additive-manufactured microwave cavity for a Ramsey-type, double resonance, compact cold-atom clock. Atoms can be laser cooled inside the cavity using a grating magneto-optic trap with the cavity providing an excellent TE011-like mode while maintaining sufficient optical access for atomic detection. The cavity features a low Q-factor of 360 which conveniently reduces the cavity pulling of the future clock. Despite the potential porosity of the additive-manufacturing process, we demonstrate that the cavity is well-suited for vacuum. A preliminary clock setup using cold atoms allows for measuring the Zeeman spectrum and Rabi oscillations in the cavity which enables us to infer excellent field uniformity and homogeneity, respectively, across the volume accessed by the cold atoms. Ramsey spectroscopy is demonstrated, indicating that the cavity is suitable for clock applications. Finally, we discuss the limitations of the future clock.


  • A Wide-Frequency-Tuning Micro-Loop-Gap Resonator for Miniature Rubidium Vapor-Cell Atomic Frequency Standards

    by Yuanyan Su, Christoph Affolderbach, Matthieu Pellaton, Gaetano Mileti, Anja K. Skrivervik

    To miniaturize the double-resonance (DR) rubidium (Rb) vapor-cell atomic clocks, a new type of micro-loop-gap microwave resonator ( $\mu$ -LGR) is proposed for TE $_{011}$ -like mode where the magnetic field inside the cavity is homogeneous and oriented along its longitudinal axis over a large volume. It provides more design degrees of freedom by elaborating the printed pattern in the middle layer, while the mechanical strength of the cavity is strong. It also possesses a wider tuning range of the resonances in order to compensate the fabrication tolerances on such miniature precision devices. A theoretical analysis of the general $\mu$ -LGR without tuning is presented first, serving as the basic guideline to design the tunable $\mu$ -LGR. To demonstrate the wide tuning mechanism, an equivalent circuit model and different tuning schemes are discussed. The measured results show that the proposed tunable $\mu$ -LGR can operate at 6.835 GHz by properly adjusting the tuning screw position. Compared to the existing $\mu$ -LGRs, this new design can achieve a 40% volume reduction (572 mm $^{3}$ , approaching the physical limit) and a comparable magnetic field quality, and enlarges the frequency tuning range to 260 MHz (twofold) in measurement. Thus, the proposed compact tunable $\mu$ -LGR has a high potential in miniature vapor-cell atomic frequency standards.


  • Open Access

    An additive-manufactured microwave cavity for a compact cold-atom clock

    by Etienne Batori, Alan Bregazzi, Ben Lewis, Paul Griffin, Erling Riis, Gaetano Mileti, Christoph Affolderbach

    We present an additive-manufactured microwave cavity for a Ramsey-type, double resonance, compact cold-atom clock. Atoms can be laser cooled inside the cavity using a grating magneto-optic trap (GMOT) with the cavity providing an excellent TE011-like mode while maintaining sufficient optical access for atomic detection. The cavity features a low Q-factor of 360 which conveniently reduces the cavity-pulling of the future clock. Despite the potential porosity of the additive-manufacturing process, we demonstrate that the cavity is well-suited for vacuum. A preliminary clock setup using cold atoms allows for measuring the Zeeman spectrum and Rabi oscillations in the cavity which enables us to infer excellent field uniformity and homogeneity respectively, across the volume accessed by the cold atoms. Ramsey spectroscopy is demonstrated, indicating the cavity is suitable for clock applications. Finally, we discuss the limitations of the future clock.

  • Open Access

    Technology roadmap for cold-atoms based quantum inertial sensor in space

    by Sven Abend, Baptiste Allard, Aidan S. Arnold, Ticijana Ban, Liam Barry, Baptiste Battelier, Ahmad Bawamia, Quentin Beaufils, Simon Bernon, Andrea Bertoldi, et al.

    Recent developments in quantum technology have resulted in a new generation of sensors for measuring inertial quantities, such as acceleration and rotation. These sensors can exhibit unprecedented sensitivity and accuracy when operated in space, where the free-fall interrogation time can be extended at will and where the environment noise is minimal. European laboratories have played a leading role in this field by developing concepts and tools to operate these quantum sensors in relevant environment, such as parabolic flights, free-fall towers, or sounding rockets. With the recent achievement of Bose–Einstein condensation on the International Space Station, the challenge is now to reach a technology readiness level sufficiently high at both component and system levels to provide “off the shelf” payload for future generations of space missions in geodesy or fundamental physics. In this roadmap, we provide an extensive review on the status of all common parts, needs, and subsystems for the application of atom-based interferometers in space, in order to push for the development of generic technology components.


  • Open Access

    μ POP Clock: A Microcell Atomic Clock Based on a Double-Resonance Ramsey Scheme

    by Etienne Batori, Christoph Affolderbach, Matthieu Pellaton, Florian Gruet, Maddalena Violetti, Yuanyan Su, Anja K. Skrivervik, Gaetano Mileti

    We demonstrate and study a microcell microwave atomic clock based on optical-microwave double resonance (DR) interrogation operated in a pulsed Ramsey scheme, called the μPOP clock, based on a microfabricated Rb vapor cell and a micro-loop-gap microwave resonator. For the mm-scale dimensions of this cell, the population and coherence relaxation rates of the Rb clock transition are on the order of 4–5 kHz, which puts constraints on the useful Ramsey times and overall pulse sequence in view of optimized clock performance. Our proof-of-principle demonstration of the μPOP clock shows that the pulsed DR approach is nevertheless feasible and results in a short-term clock stability of 1 × 10−11 τ−1/2 and reaching the ≤2 × 10−12 level at timescales of 1000 s to one day. The short-term instability budget established for the μPOP clock shows that the main limitation to the short-term stability arises from the detection noise. Thanks to the pulsed Ramsey scheme, light-shift effects are strongly reduced in the μPOP clock, which opens perspectives for further improvements of long-term clock stability, in view of future generations of miniature vapor-cell clocks with enhanced performances based on the DR scheme.


  • Open Access

    GNSS-grade space atomic frequency standards: Current status and ongoing developments

    by Etienne Batori, Nil Almat, Christoph Affolderbach, Gaetano Mileti


  • Open Access

    Long-Term Stability Analysis Toward −14 Level for a Highly Compact POP Rb Cell Atomic Clock

    by Nil Almat, Mohammadreza Gharavipour, William Moreno, Florian Gruet, Christoph Affolderbach, Gaetano Mileti

    Long-term frequency instabilities in vapor-cell clocks mainly arise from fluctuations of the experimental and environmental parameters that are converted to clock frequency fluctuations via various physical processes. Here, we discuss the frequency sensitivities and the resulting stability limitations at one day timescale for a rubidium vapor-cell clock based on a compact magnetron-type cavity operated in air (no vacuum environment). Under ambient laboratory conditions, the external atmospheric pressure fluctuations may dominantly limit the clock stability via the barometric effect. We establish a complete long-term instability budget for our clock operated under stable pressure conditions. Where possible, the fluctuations of experimental parameters are measured via the atomic response. The measured clock instability of < 2·E10.14 at one day is limited by the intensity light-shift effect, which could further be reduced by active stabilization of the laser intensity or stronger optical pumping. The analyses reported here show the way towards simple, compact, and low-power vapor-cell atomic clocks with excellent long-term stabilities. ≤ 10.14 at one day when operated in ambient laboratory conditions.