CAChristoph Affolderbach

Christoph Affolderbach

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christoph Affolderbach has a total of 191 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Mode Suppression and Homogeneous Field Bandwidth Enhancement of a Tuning-Free Micro-Loop-Gap Resonator Using FR4 for Chip-Scale Rubidium Clock

    by Yuanyan Su, Matthieu Pellaton, Christoph Affolderbach, Gaetano Mileti, Anja K. Skrivervik

    We propose strategies for the design of a tuning-free micro-loop-gap resonator ( $\mu$ -LGR) that provides high magnetic field homogeneity of the TE $_{011}$ -like mode over a broad bandwidth with a high field orientation factor (FOF). This broadband feature allows it to fulfill the FOF requirement at the precise 6.835 GHz resonance for chip-scale double-resonance (DR) rubidium (Rb) clocks without the need for any mechanical or electrical frequency tuning means. The FOF bandwidth expansion mechanism manipulates the unwanted side modes by using perturbation theory and distinct properties of the FR4 substrate characterized by an accurate method for the long-term stabilities in high temperatures. Thanks to the absence of tuning components and the usage of lossy FR4, this new $\mu$ -LGR achieves better FOF in a wide bandwidth of $\sim$ 550 MHz and simplifies the physics package (PP) of the entire clock system. The measured $S$ -parameters of the fabricated $\mu $ -LGR prototype and its cavity-cell assembly validate that the cell-loaded $\mu$ -LGR can operate over a 128 MHz impedance bandwidth of $\vert S_{11} \vert < -10$ dB at $\sim$ 109 $^{\circ}$ C, with strong resonance at 6.83 GHz and a loaded quality factor of 12.7 which does not result in reduced signal strength but is advantageous to alleviating cavity pulling for optically detected passive DR Rb clocks. Moreover, a spectroscopic experiment of the developed chip-scale atomic clock (CSAC) based on the proposed $\mu$ -LGR verifies that the tuning-free $\mu$ -LGR can obtain a FOF $_{\text{exp}}$ of 0.75 at 6.835 GHz, therefore guaranteeing the atom transition to be well excited for the clock operation.


  • Open Access

    An additive-manufactured microwave cavity for a compact cold-atom clock

    by Etienne Batori, Alan Bregazzi, Ben Lewis, Paul F. Griffin, Erling Riis, Gaetano Mileti, Christoph Affolderbach

    We present an additive-manufactured microwave cavity for a Ramsey-type, double resonance, compact cold-atom clock. Atoms can be laser cooled inside the cavity using a grating magneto-optic trap with the cavity providing an excellent TE011-like mode while maintaining sufficient optical access for atomic detection. The cavity features a low Q-factor of 360 which conveniently reduces the cavity pulling of the future clock. Despite the potential porosity of the additive-manufacturing process, we demonstrate that the cavity is well-suited for vacuum. A preliminary clock setup using cold atoms allows for measuring the Zeeman spectrum and Rabi oscillations in the cavity which enables us to infer excellent field uniformity and homogeneity, respectively, across the volume accessed by the cold atoms. Ramsey spectroscopy is demonstrated, indicating that the cavity is suitable for clock applications. Finally, we discuss the limitations of the future clock.


  • A Wide-Frequency-Tuning Micro-Loop-Gap Resonator for Miniature Rubidium Vapor-Cell Atomic Frequency Standards

    by Yuanyan Su, Christoph Affolderbach, Matthieu Pellaton, Gaetano Mileti, Anja K. Skrivervik

    To miniaturize the double-resonance (DR) rubidium (Rb) vapor-cell atomic clocks, a new type of micro-loop-gap microwave resonator ( $\mu$ -LGR) is proposed for TE $_{011}$ -like mode where the magnetic field inside the cavity is homogeneous and oriented along its longitudinal axis over a large volume. It provides more design degrees of freedom by elaborating the printed pattern in the middle layer, while the mechanical strength of the cavity is strong. It also possesses a wider tuning range of the resonances in order to compensate the fabrication tolerances on such miniature precision devices. A theoretical analysis of the general $\mu$ -LGR without tuning is presented first, serving as the basic guideline to design the tunable $\mu$ -LGR. To demonstrate the wide tuning mechanism, an equivalent circuit model and different tuning schemes are discussed. The measured results show that the proposed tunable $\mu$ -LGR can operate at 6.835 GHz by properly adjusting the tuning screw position. Compared to the existing $\mu$ -LGRs, this new design can achieve a 40% volume reduction (572 mm $^{3}$ , approaching the physical limit) and a comparable magnetic field quality, and enlarges the frequency tuning range to 260 MHz (twofold) in measurement. Thus, the proposed compact tunable $\mu$ -LGR has a high potential in miniature vapor-cell atomic frequency standards.


  • Open Access

    μ POP Clock: A Microcell Atomic Clock Based on a Double-Resonance Ramsey Scheme

    by Etienne Batori, Christoph Affolderbach, Matthieu Pellaton, Florian Gruet, Maddalena Violetti, Yuanyan Su, Anja K. Skrivervik, Gaetano Mileti

    We demonstrate and study a microcell microwave atomic clock based on optical-microwave double resonance (DR) interrogation operated in a pulsed Ramsey scheme, called the μPOP clock, based on a microfabricated Rb vapor cell and a micro-loop-gap microwave resonator. For the mm-scale dimensions of this cell, the population and coherence relaxation rates of the Rb clock transition are on the order of 4–5 kHz, which puts constraints on the useful Ramsey times and overall pulse sequence in view of optimized clock performance. Our proof-of-principle demonstration of the μPOP clock shows that the pulsed DR approach is nevertheless feasible and results in a short-term clock stability of 1 × 10−11 τ−1/2 and reaching the ≤2 × 10−12 level at timescales of 1000 s to one day. The short-term instability budget established for the μPOP clock shows that the main limitation to the short-term stability arises from the detection noise. Thanks to the pulsed Ramsey scheme, light-shift effects are strongly reduced in the μPOP clock, which opens perspectives for further improvements of long-term clock stability, in view of future generations of miniature vapor-cell clocks with enhanced performances based on the DR scheme.


  • Open Access

    Long-Term Stability Analysis Toward −14 Level for a Highly Compact POP Rb Cell Atomic Clock

    by Nil Almat, Mohammadreza Gharavipour, William Moreno, Florian Gruet, Christoph Affolderbach, Gaetano Mileti

    Long-term frequency instabilities in vapor-cell clocks mainly arise from fluctuations of the experimental and environmental parameters that are converted to clock frequency fluctuations via various physical processes. Here, we discuss the frequency sensitivities and the resulting stability limitations at one day timescale for a rubidium vapor-cell clock based on a compact magnetron-type cavity operated in air (no vacuum environment). Under ambient laboratory conditions, the external atmospheric pressure fluctuations may dominantly limit the clock stability via the barometric effect. We establish a complete long-term instability budget for our clock operated under stable pressure conditions. Where possible, the fluctuations of experimental parameters are measured via the atomic response. The measured clock instability of < 2·E10.14 at one day is limited by the intensity light-shift effect, which could further be reduced by active stabilization of the laser intensity or stronger optical pumping. The analyses reported here show the way towards simple, compact, and low-power vapor-cell atomic clocks with excellent long-term stabilities. ≤ 10.14 at one day when operated in ambient laboratory conditions.


  • Investigations on Microwave Power Shift in Compact Vapor-Cell Atomic Clock

    by W. Moreno, M. Pellaton, N. Almat, M. Gharavipour, C. Affolderbach, G. Mileti

    We employ a three-level Bloch vector model to simulate Ramsey fringes of our Rb vapor-cell atomic clock. The residual inhomogeneity of the microwave magnetic field across the buffer-gas cell is a key ingredient for correctly modelling the behavior at high microwave powers (pulse area > π/2. We add to this model different position-dependent frequency shifts that arise from external fields, and we identify inhomogeneous light-shifts as the dominant contribution for reproducing the measured clock frequency shifts as a function of microwave power. Other frequency shifts give negligible contributions.


  • Open Access

    Barometric Effect in Vapor-Cell Atomic Clocks

    by William Moreno, Matthieu Pellaton, Christoph Affolderbach, Gaetano Mileti

    Vapor-cell atomic clocks are compact and highperformance frequency references employed in various applications ranging from telecommunication to global positioning systems. Environmental sensitivities are often the main sources of long-term instabilities of the clock frequency. Among these sensitivities, the environmental pressure shift describes the clock frequency change with respect to the environmental pressure variations. We report here on our theoretical and experimental analysis of the environmental pressure shift on Rubidium atomic frequency standards (RAFS) operated under open atmosphere. By using an unsealed highperformance laser-pumped Rubidium standard, we demonstrate that the deformation of the vapor-cell volume induced by the environmental pressure changes (i.e barometric effect) is the dominant environmental pressure shift in a standard laboratory environment. An experimental barometric coefficient of 8.2×10-14/hPa is derived, in good agreement with theory and with previously reported measurements of frequency shifts of RAFS operated when transiting to vacuum.


  • Rb vapor-cell clock demonstration with a frequency-doubled telecom laser

    by Nil Almat, Matthieu Pellaton, William Moreno, Florian Gruet, Christoph Affolderbach, Gaetano Mileti

    We employ a recently developed laser system, based on a low-noise telecom laser emitting around 1.56 μm, to evaluate its impact on the performance of an Rb vapor-cell clock in a continuous-wave double-resonance scheme. The achieved short-term clock instability below 2.5·10−13·τ−1/2 demonstrates, for the first time, the suitability of a frequency-doubled telecom laser for this specific application. We measure and study quantitatively the impact of laser amplitude and frequency noises and of the ac Stark shift, which limit the clock frequency stability on short timescales. We also report on the detailed noise budgets and demonstrate experimentally that, under certain conditions, the short-term stability of the clock operated with the low-noise telecom laser is improved by a factor of three compared to clock operation using the direct 780-nm laser.


  • Open Access

    3D printed microwave cavity for atomic clock applications: proof of concept

    by M. Pellaton, C. Affolderbach, A.K. Skrivervik, A.E. Ivanov, T. Debogovic, E. de Rijk, G. Mileti

    The authors present the realisation and characterisation of an additively manufactured (AM) microwave resonator cavity for double‐resonance (DR) vapour‐cell atomic clocks. The design of the compact microwave cavity is based on the loop‐gap resonator approach, previously demonstrated for conventionally‐machined aluminium components. In the present study, the resonator is fabricated by AM using a metal‐coated polymer. A resonance frequency at the desired 6.835 GHz rubidium atomic frequency is obtained. When employed in an atomic clock setup, the AM cavity enables a DR signal of −12 τ −1/2 is demonstrated, comparable to state‐of‐the‐art clock performances.