Melanie Ml Green
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Melanie Ml Green has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Catharine Mary Louise West
The University of Manchester, Manchester, United Kingdom
3 shared publications - Gillian A. Whitfield
Clinical Oncology, The Christie NHS Foundation Trust, Manchester, UK
3 shared publications Patricia M. Price
Radiation Oncology, The Harley Street Clinic, HCA Healthcare, London, GBR
3 shared publicationsPooja Jain
Academic Department of Radiation Oncology, Manchester Academic Health Sciences Centre, The University of Manchester, Manchester, United Kingdom ; The Christie National Health Service (NHS) Foundation Trust, Manchester, United Kingdom
3 shared publicationsChristopher Moore
2 shared publicationsGillian Watkins
2 shared publications
Latest Publications
- Open Access
- 30 October 2018
- Published by Springer Nature in Cureus
- Vol. 10  (10) , e3523
Evaluation of CyberKnife® Fiducial Tracking Limitations to Assist Targeting Accuracy: A Phantom Study with Fiducial Displacement
The underlying assumptions of the CyberKnife® (Accuray, Sunnyvale, CA, US) fiducial tracking system are: i) fiducial positions are accurately detected; ii) inter-fiducial geometry remains consistent (rigid); iii) inter-fiducial geometric array changes are detected and either accommodated with corrections or treatment is interrupted. However: i) soft-tissue targets are deformable & fiducial migration is possible; ii) the accuracy of the tracking system has not previously been examined with fiducial displacement; iii) treatment interruptions may occur due to inter-fiducial geometric changes, but there is little information available to assist subsequent troubleshooting. The purpose of this study was to emulate a clinical target defined with a two, three, or four-fiducial array where one fiducial is displaced to mimic a target deformation or fiducial migration scenario. The objectives: evaluate the fiducial positioning accuracy, array interpretation, & corresponding corrections of the CyberKnife system, with the aim of assisting troubleshooting following fiducial displacement. A novel solid-water phantom was constructed with three fixed fiducials (F1,F2,F3) & one moveable fiducial (F4), arranged as if placed to track an imaginary clinical target. Using either two fiducials (F1,F4), different combinations of three fiducials (F1,F2,F4; F1,F3,F4; F2,F3,F4) or four fiducials (F1,F2,F3,F4), repeat experiments were conducted where F4 was displaced inferiorly at 2-mm intervals from 0-16 mm. Data were acquired at each position of F4, including rigid body errors (RBE), fiducial x, y, & z coordinate displacements, six degrees of freedom (DOF) corrections, & robot center-of-mass (COM) translation corrections. Maximum positioning difference (mean±SD) between the reference and live x, y, & z coordinates for the three fixed fiducials was 0.08±0.30 mm, confirming good accuracy for fixed fiducial registration. For two fiducials (F1,F4), F4 registration was accurate to 14-mm displacement and the F4 x-axis coordinate change was 2.0±0.12 mm with each 2 mm inferior displacement validating the phantom for tracking evaluation. RBE was >5 mm (system threshold) at 6-14 mm F4 displacement: however, F1 was misidentified as the RBE main contributor. Further, F1/F4 false-lock occurred at 16 mm F4 displacement with corresponding RBE 13 mm. For combinations of three fiducials, F4 registration was accurate to 10-mm displacement. RBE was >5 mm at 6-16 mm F4 displacement: however, F4 false-lock occurred at 12-16 mm with RBE 5-6 mm. For four fiducials, F4 registration was accurate to 4 mm displacement: however, F4 false-lock occurred at 6-16 mm displacement with concerning RBE <2 & <5 at 6 & 8-mm F4 displacement, respectively. False-locks were easily identified in the phantom but frequently uncorrectable. Results indicate fiducial positioning accuracy and system output following fiducial displacement depends on the number of fiducials correlated, displacement distance, and clinical thresholds applied. Displacements ≤4 mm were accurately located, but some displacements 6-16 mm were misrepresented, either by erroneous main contributor (two-fiducial array only) or by false-locks and misleading RBE, which underestimated displacement. Operator vigilance and implementation of our practical guidelines based on the study findings may help reduce targeting error and assist troubleshooting in clinical situations.
- 30 October 2018
- Published by Springer Nature in Cureus
- Vol. 10  (10) , e3523
Open AccessEvaluation of CyberKnife® Fiducial Tracking Limitations to Assist Targeting Accuracy: A Phantom Study with Fiducial Displacement
The underlying assumptions of the CyberKnife® (Accuray, Sunnyvale, CA, US) fiducial tracking system are: i) fiducial positions are accurately detected; ii) inter-fiducial geometry remains consistent (rigid); iii) inter-fiducial geometric array changes are detected and either accommodated with corrections or treatment is interrupted. However: i) soft-tissue targets are deformable & fiducial migration is possible; ii) the accuracy of the tracking system has not previously been examined with fiducial displacement; iii) treatment interruptions may occur due to inter-fiducial geometric changes, but there is little information available to assist subsequent troubleshooting. The purpose of this study was to emulate a clinical target defined with a two, three, or four-fiducial array where one fiducial is displaced to mimic a target deformation or fiducial migration scenario. The objectives: evaluate the fiducial positioning accuracy, array interpretation, & corresponding corrections of the CyberKnife system, with the aim of assisting troubleshooting following fiducial displacement. A novel solid-water phantom was constructed with three fixed fiducials (F1,F2,F3) & one moveable fiducial (F4), arranged as if placed to track an imaginary clinical target. Using either two fiducials (F1,F4), different combinations of three fiducials (F1,F2,F4; F1,F3,F4; F2,F3,F4) or four fiducials (F1,F2,F3,F4), repeat experiments were conducted where F4 was displaced inferiorly at 2-mm intervals from 0-16 mm. Data were acquired at each position of F4, including rigid body errors (RBE), fiducial x, y, & z coordinate displacements, six degrees of freedom (DOF) corrections, & robot center-of-mass (COM) translation corrections. Maximum positioning difference (mean±SD) between the reference and live x, y, & z coordinates for the three fixed fiducials was 0.08±0.30 mm, confirming good accuracy for fixed fiducial registration. For two fiducials (F1,F4), F4 registration was accurate to 14-mm displacement and the F4 x-axis coordinate change was 2.0±0.12 mm with each 2 mm inferior displacement validating the phantom for tracking evaluation. RBE was >5 mm (system threshold) at 6-14 mm F4 displacement: however, F1 was misidentified as the RBE main contributor. Further, F1/F4 false-lock occurred at 16 mm F4 displacement with corresponding RBE 13 mm. For combinations of three fiducials, F4 registration was accurate to 10-mm displacement. RBE was >5 mm at 6-16 mm F4 displacement: however, F4 false-lock occurred at 12-16 mm with RBE 5-6 mm. For four fiducials, F4 registration was accurate to 4 mm displacement: however, F4 false-lock occurred at 6-16 mm displacement with concerning RBE <2 & <5 at 6 & 8-mm F4 displacement, respectively. False-locks were easily identified in the phantom but frequently uncorrectable. Results indicate fiducial positioning accuracy and system output following fiducial displacement depends on the number of fiducials correlated, displacement distance, and clinical thresholds applied. Displacements ≤4 mm were accurately located, but some displacements 6-16 mm were misrepresented, either by erroneous main contributor (two-fiducial array only) or by false-locks and misleading RBE, which underestimated displacement. Operator vigilance and implementation of our practical guidelines based on the study findings may help reduce targeting error and assist troubleshooting in clinical situations.
- Open Access
- 19 October 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13  (1) , 204
Stereotactic ablative radiotherapy (SABR) as primary, adjuvant, consolidation and re-treatment option in pancreatic cancer: scope for dose escalation and lessons for toxicity
Stereotactic ablative radiotherapy (SABR) offers an alternative treatment for pancreatic cancer, with the potential for improved tumour control and reduced toxicity compared with conventional therapies. However, optimal dose planning and delivery strategies are unelucidated and gastro-intestinal (GI) toxicity remains a key concern. Patients with inoperable non-metastatic pancreatic cancer who received CyberKnife® SABR (18–36 Gy) in three fractions as primary, adjuvant, consolidation or re-treatment options were studied. Patient individualised planning and delivery variables were collected and their impact on patient outcome examined. Linear-quadratic (LQ) radiobiology modelling methods were applied to assess SABR parameters against a conventional fractionated radiotherapy schedule. In total 42 patients were included, 37 (88%) of whom had stage T4 disease. SABR was used > 6 months post-primary therapy to re-treat residual disease in 11 (26.2%) patients and relapsed disease in nine (21.4%) patients. SABR was an adjuvant to other primary therapy for 14 (33.3%) patients and was the sole primary therapy for eight (19.0%) patients. The mean (95% CI) planning target volume (PTV), prescription isodose, percentage cover, minimum dose to PTV and biological effective dose (BED) were 76.3(63.8–88.7) cc, 67.3(65.2–69.5)%, 96.6(95.5–97.7)%, 22.3(21.0–23.6) Gy and 50.3(47.7–53.0) Gy, respectively. Only 3/37 (8.1%) patients experienced Grade 3 acute toxicities. Two (4.8%) patients converted to resectable status and median freedom-from-local-progression (FFLP) and overall survival (OS) were 9.8 and 8.4 months, respectively. No late toxicity was experienced in 27/32 (84.4%) patients; however, four (12.5%) patients — of whom two had particularly large PTV, two had sub-optimal number of fiducials and three breached organ-at-risk (OAR) constraints—showed Grade 4 duodenal toxicities. Longer delivery time, extended treatment course and reduced percentage coverage additionally associated with late toxicity, likely reflecting parameters typically applied to riskier patients. Larger PTV size and longer treatment course associated with OS. Comparator regimen LQ modelling analysis indicated 50% of patients received minimum PTV doses less potent than a conventional radiotherapy regimen, indicating scope for dose escalation. The results demonstrate the value of SABR for a range of indications in pancreatic cancer. Dose escalation to increase BED may improve FFLP and OS in inoperable, non-metastatic disease: however concomitant enhanced stringency for duodenal protection is critical, particularly for patients where SABR is more challenging.
- 19 October 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13  (1) , 204
Open AccessStereotactic ablative radiotherapy (SABR) as primary, adjuvant, consolidation and re-treatment option in pancreatic cancer: scope for dose escalation and lessons for toxicity
Stereotactic ablative radiotherapy (SABR) offers an alternative treatment for pancreatic cancer, with the potential for improved tumour control and reduced toxicity compared with conventional therapies. However, optimal dose planning and delivery strategies are unelucidated and gastro-intestinal (GI) toxicity remains a key concern. Patients with inoperable non-metastatic pancreatic cancer who received CyberKnife® SABR (18–36 Gy) in three fractions as primary, adjuvant, consolidation or re-treatment options were studied. Patient individualised planning and delivery variables were collected and their impact on patient outcome examined. Linear-quadratic (LQ) radiobiology modelling methods were applied to assess SABR parameters against a conventional fractionated radiotherapy schedule. In total 42 patients were included, 37 (88%) of whom had stage T4 disease. SABR was used > 6 months post-primary therapy to re-treat residual disease in 11 (26.2%) patients and relapsed disease in nine (21.4%) patients. SABR was an adjuvant to other primary therapy for 14 (33.3%) patients and was the sole primary therapy for eight (19.0%) patients. The mean (95% CI) planning target volume (PTV), prescription isodose, percentage cover, minimum dose to PTV and biological effective dose (BED) were 76.3(63.8–88.7) cc, 67.3(65.2–69.5)%, 96.6(95.5–97.7)%, 22.3(21.0–23.6) Gy and 50.3(47.7–53.0) Gy, respectively. Only 3/37 (8.1%) patients experienced Grade 3 acute toxicities. Two (4.8%) patients converted to resectable status and median freedom-from-local-progression (FFLP) and overall survival (OS) were 9.8 and 8.4 months, respectively. No late toxicity was experienced in 27/32 (84.4%) patients; however, four (12.5%) patients — of whom two had particularly large PTV, two had sub-optimal number of fiducials and three breached organ-at-risk (OAR) constraints—showed Grade 4 duodenal toxicities. Longer delivery time, extended treatment course and reduced percentage coverage additionally associated with late toxicity, likely reflecting parameters typically applied to riskier patients. Larger PTV size and longer treatment course associated with OS. Comparator regimen LQ modelling analysis indicated 50% of patients received minimum PTV doses less potent than a conventional radiotherapy regimen, indicating scope for dose escalation. The results demonstrate the value of SABR for a range of indications in pancreatic cancer. Dose escalation to increase BED may improve FFLP and OS in inoperable, non-metastatic disease: however concomitant enhanced stringency for duodenal protection is critical, particularly for patients where SABR is more challenging.
- Open Access
- 1 June 2017
- Published by Taylor & Francis in Breast Cancer: Targets and Therapy
- Vol. ume 9, 437-446
An effective deep-inspiration breath-hold radiotherapy technique for left-breast cancer: impact of post-mastectomy treatment, nodal coverage, and dose schedule on organs at risk
Background: We developed, applied, and prospectively evaluated a novel deep-inspiration breath-hold (DIBH) screening and delivery technique to optimize cardiac sparing in left-breast radiotherapy (RT) at our clinic. The impact of set-up and dose variables upon organs at risk (OAR) dose in DIBH RT was investigated. Methods and materials: All patients with left-breast cancer referred between 2011 and 2014 – of all disease stages, set-up variations, and dose prescriptions – were included. Radiographers used simple screening criteria at CT simulation, to systematically assess patients for obvious DIBH benefit and capability. Selected patients received forward-planned intensity-modulated RT (IMRT) based on a DIBH CT scan. A 3D-surface monitoring system with visual feedback assured reproducible DIBH positioning during gated radiation delivery. Patient, target set-up, and OAR dose information were collected at treatment. Results: Of 272 patients who were screened, 4 withdrew, 56 showed no obvious advantage, and 56 showed benefit but had suitability issues; 156 patients were selected and successfully completed DIBH treatment. The technique was compatible with complex set-up and optimal target coverage was maintained. Comparison of free-breathing (FB) and DIBH treatment plans in the first five patients enrolled confirmed DIBH reduced heart radiation by ~80% (p = 0.032). Low OAR doses were achieved overall: the mean (95% confidence interval [CI]) heart dose was 1.17 (1.12–1.22) Gy, and the mean ipsilateral lung dose was 5.26 (5.01–5.52) Gy. Patients who underwent a standard radiation schedule (40 Gy/15#) after breast-conserving surgery had the lowest OAR doses: post-mastectomy treatment, simultaneous supraclavicular (SCV) node coverage, and alternative dose schedule (50 Gy/25#) were interrelated variables associated with increased OAR risk and compromised ipsilateral lung dose constraints. Conclusion: The DIBH technique was successfully implemented and resulted in optimally low heart radiation. All patients who demonstrate sufficient DIBH technique at planning CT are now offered DIBH RT at our clinic. Patients with more advanced disease, particularly those with additional pulmonary risk factors, warrant additional focus to improve lung sparing.
- 1 June 2017
- Published by Taylor & Francis in Breast Cancer: Targets and Therapy
- Vol. ume 9, 437-446
Open AccessAn effective deep-inspiration breath-hold radiotherapy technique for left-breast cancer: impact of post-mastectomy treatment, nodal coverage, and dose schedule on organs at risk
Background: We developed, applied, and prospectively evaluated a novel deep-inspiration breath-hold (DIBH) screening and delivery technique to optimize cardiac sparing in left-breast radiotherapy (RT) at our clinic. The impact of set-up and dose variables upon organs at risk (OAR) dose in DIBH RT was investigated. Methods and materials: All patients with left-breast cancer referred between 2011 and 2014 – of all disease stages, set-up variations, and dose prescriptions – were included. Radiographers used simple screening criteria at CT simulation, to systematically assess patients for obvious DIBH benefit and capability. Selected patients received forward-planned intensity-modulated RT (IMRT) based on a DIBH CT scan. A 3D-surface monitoring system with visual feedback assured reproducible DIBH positioning during gated radiation delivery. Patient, target set-up, and OAR dose information were collected at treatment. Results: Of 272 patients who were screened, 4 withdrew, 56 showed no obvious advantage, and 56 showed benefit but had suitability issues; 156 patients were selected and successfully completed DIBH treatment. The technique was compatible with complex set-up and optimal target coverage was maintained. Comparison of free-breathing (FB) and DIBH treatment plans in the first five patients enrolled confirmed DIBH reduced heart radiation by ~80% (p = 0.032). Low OAR doses were achieved overall: the mean (95% confidence interval [CI]) heart dose was 1.17 (1.12–1.22) Gy, and the mean ipsilateral lung dose was 5.26 (5.01–5.52) Gy. Patients who underwent a standard radiation schedule (40 Gy/15#) after breast-conserving surgery had the lowest OAR doses: post-mastectomy treatment, simultaneous supraclavicular (SCV) node coverage, and alternative dose schedule (50 Gy/25#) were interrelated variables associated with increased OAR risk and compromised ipsilateral lung dose constraints. Conclusion: The DIBH technique was successfully implemented and resulted in optimally low heart radiation. All patients who demonstrate sufficient DIBH technique at planning CT are now offered DIBH RT at our clinic. Patients with more advanced disease, particularly those with additional pulmonary risk factors, warrant additional focus to improve lung sparing.
- Open Access
- 11 May 2015
- Published by Oxford University Press (OUP) in BJR|case reports
- Vol. 1  (2) , 20150038
Deep inspiration breath-hold (DIBH) technique applied in right breast radiotherapy to minimize liver radiation
A right-sided breast cancer patient (stage T1N0M0) was referred for post-surgical radiotherapy to minimize risk of local tumour recurrence. During the CT simulation and intensity-modulated radiotherapy planning process undertaken in free breathing, it was apparent that an unusually large volume of normal liver tissue (134 cc) was in the high-dose region of the tangential radiation field. This raised concern for risk of liver side effects and was considered suboptimal for this excellent prognosis patient. A deep inspiration breath-hold (DIBH) technique using three-dimensional (3D) surface monitoring-primarily developed and applied in left breast cancer to displace cardiac tissue from the target field-was investigated to determine potential benefit to optimize radiotherapy delivery. Resimulation of DIBH resulted in considerable displacement of the liver, reducing the volume of liver tissue in the target field by 63% (to 50 cc) and the mean liver dose by 46% (to 2.6 Gy). As the patient was deemed suitable for the DIBH technique, treatment was delivered according to the DIBH plan. A total of 40.05 Gy in 15 fractions was successfully delivered in the DIBH position using a technique that incorporated 3D body surface imaging with automated radiation beam hold-off when out of tolerance. Additional advantages were optimal set up without extensive immobilization and the elimination of respiratory motion. Acute mild skin erythema was the only side effect experienced-no liver sequalae were experienced by the patient up to 6 months after treatment. DIBH treatment may improve liver sparing in other similar right breast cancer patients.
- 11 May 2015
- Published by Oxford University Press (OUP) in BJR|case reports
- Vol. 1  (2) , 20150038
Open AccessDeep inspiration breath-hold (DIBH) technique applied in right breast radiotherapy to minimize liver radiation
A right-sided breast cancer patient (stage T1N0M0) was referred for post-surgical radiotherapy to minimize risk of local tumour recurrence. During the CT simulation and intensity-modulated radiotherapy planning process undertaken in free breathing, it was apparent that an unusually large volume of normal liver tissue (134 cc) was in the high-dose region of the tangential radiation field. This raised concern for risk of liver side effects and was considered suboptimal for this excellent prognosis patient. A deep inspiration breath-hold (DIBH) technique using three-dimensional (3D) surface monitoring-primarily developed and applied in left breast cancer to displace cardiac tissue from the target field-was investigated to determine potential benefit to optimize radiotherapy delivery. Resimulation of DIBH resulted in considerable displacement of the liver, reducing the volume of liver tissue in the target field by 63% (to 50 cc) and the mean liver dose by 46% (to 2.6 Gy). As the patient was deemed suitable for the DIBH technique, treatment was delivered according to the DIBH plan. A total of 40.05 Gy in 15 fractions was successfully delivered in the DIBH position using a technique that incorporated 3D body surface imaging with automated radiation beam hold-off when out of tolerance. Additional advantages were optimal set up without extensive immobilization and the elimination of respiratory motion. Acute mild skin erythema was the only side effect experienced-no liver sequalae were experienced by the patient up to 6 months after treatment. DIBH treatment may improve liver sparing in other similar right breast cancer patients.
- Open Access
- 1 February 2014
- Published by Elsevier in Translational Oncology
- Vol. 7  (1) , 55-64
Phase II Trial of Cetuximab and Conformal Radiotherapy Only in Locally Advanced Pancreatic Cancer with Concurrent Tissue Sampling Feasibility Study
- 1 February 2014
- Published by Elsevier in Translational Oncology
- Vol. 7  (1) , 55-64
Open AccessPhase II Trial of Cetuximab and Conformal Radiotherapy Only in Locally Advanced Pancreatic Cancer with Concurrent Tissue Sampling Feasibility Study
- 1 June 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 103  (3) , 360-366
Quantifying motion for pancreatic radiotherapy margin calculation
- 1 June 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 103  (3) , 360-366
Quantifying motion for pancreatic radiotherapy margin calculation
- 1 December 2011
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 84  (special__1) , S19-S34
Positron emission tomography imaging approaches for external beam radiation therapies: current status and future developments
In an era in which it is possible to deliver radiation with high precision, there is a heightened need for enhanced imaging capabilities to improve tumour localisation for diagnostic, planning and delivery purposes. This is necessary to increase the accuracy and overall efficacy of all types of external beam radiotherapy (RT), including particle therapies. Positron emission tomography (PET) has the potential to fulfil this need by imaging fundamental aspects of tumour biology. The key areas in which PET may support the RT process include improving disease diagnosis and staging; assisting tumour volume delineation; defining tumour phenotype or biological tumour volume; assessment of treatment response; and in-beam monitoring of radiation dosimetry. The role of PET and its current developmental status in these key areas are overviewed in this review, highlighting the advantages and drawbacks.
- 1 December 2011
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 84  (special__1) , S19-S34
Positron emission tomography imaging approaches for external beam radiation therapies: current status and future developments
In an era in which it is possible to deliver radiation with high precision, there is a heightened need for enhanced imaging capabilities to improve tumour localisation for diagnostic, planning and delivery purposes. This is necessary to increase the accuracy and overall efficacy of all types of external beam radiotherapy (RT), including particle therapies. Positron emission tomography (PET) has the potential to fulfil this need by imaging fundamental aspects of tumour biology. The key areas in which PET may support the RT process include improving disease diagnosis and staging; assisting tumour volume delineation; defining tumour phenotype or biological tumour volume; assessment of treatment response; and in-beam monitoring of radiation dosimetry. The role of PET and its current developmental status in these key areas are overviewed in this review, highlighting the advantages and drawbacks.
- Open Access
- 22 July 2010
- Published by Elsevier in Clinical Oncology
- Vol. 22  (7) , 570-577
Efficacy and Tolerability of Limited Field Radiotherapy with Concurrent Capecitabine in Locally Advanced Pancreatic Cancer
- 22 July 2010
- Published by Elsevier in Clinical Oncology
- Vol. 22  (7) , 570-577
Open AccessEfficacy and Tolerability of Limited Field Radiotherapy with Concurrent Capecitabine in Locally Advanced Pancreatic Cancer
- 1 November 2009
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 75  (3) , 664-671
Assessment of Bladder Motion for Clinical Radiotherapy Practice Using Cine–Magnetic Resonance Imaging
- 1 November 2009
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 75  (3) , 664-671
Assessment of Bladder Motion for Clinical Radiotherapy Practice Using Cine–Magnetic Resonance Imaging
- 30 June 2009
- Published by Elsevier in Clinical Oncology
- Vol. 21  (5) , 385-393
Ultrasound Imaging to Assess Inter- and Intra-fraction Motion during Bladder Radiotherapy and its Potential as a Verification Tool
- 30 June 2009
- Published by Elsevier in Clinical Oncology
- Vol. 21  (5) , 385-393
Ultrasound Imaging to Assess Inter- and Intra-fraction Motion during Bladder Radiotherapy and its Potential as a Verification Tool