AVAlex Virgilio

Alex Virgilio

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alex Virgilio has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Evaluation of Closed-Vessel Conductively-Heated Digestion System with Diluted Acid for Analysis of Animal Feed by ICP-MS

    by Rayane Costa, Edilene Ferreira, Alex Virgilio, Elisabete Fernandes, José Anchieta Gomes Neto

    A conductively-heated digestion system (CHDS) with closed-vessel and diluted acid was evaluated for the preparation of animal feed for subsequent determination of As, Cd, Mo, Ni, Pb, Se and V by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The analytical performance of the digestor was checked by analyzing fish tissue, tuna and corn bran certified reference materials (CRMs) using 1 mL of 30% (w w-1) hydrogen peroxide plus 2 mL of nitric acid at 14, 7 and 3.5 mol L-1 HNO3. The recoveries of analytes in CRMs digested at different acid concentrations varied from 80 – 116% (3.5 mol L⁻¹ HNO₃) 86 – 118% (7 mol L⁻¹ HNO₃) e 80 – 123% (14 mol L⁻¹ HNO₃). The method was applied to real animal feed samples, and the CHDS results were like those of comparative microwave digestion (MWD). Quantification limits of analytes found by CHDS and MWD were also similar, concerning different acid concentrations. However, the use of diluted nitric acid in the preparation of animal feed samples proved to be a viable and efficient approach, allowing lower residual acidity, reduction in reagent consumption and acid waste generation, in accordance with the principles of Green Chemistry.

  • FREQUENT ANALYTICAL QUESTIONS (FAQ) - 20 DÚVIDAS COMUNS EM QUÍMICA ANALÍTICA

    by Alex Virgilio, Fernanda N. Feiteira, João Flávio S. Petruci, Rafaella R. A. Peixoto

    FREQUENT ANALYTICAL QUESTIONS (FAQ) - 20 COMMON QUESTIONS IN ANALYTICAL CHEMISTRY. Twenty frequently asked questions in analytical chemistry are presented in a clear, instructive, and accessible manner. In the context of classical analysis, the text addresses questions related to types of solutions and their preparation, as well as key definitions of qualitative and quantitative methods, volumetric analysis, and heavy metals. It also covers essential topics such as analytical sequence, use of certified reference materials, distinctions among analytical methods, procedures, and techniques, and the main analytical figures of merit. Finally, fundamental aspects of instrumental analysis – including noise, background signals, detectability, detection and quantification limits, and calibration – are discussed, along with statistical considerations related to precision, linear modeling, and significance testing.

  • Closed-vessel conductively heated digestion system with diluted nitric acid for the preparation of biomass and biochar samples

    by Evilim Martinez Oliveira, Edilene Cristina Ferreira, José Anchieta Gomes Neto, Alex Virgilio


  • Open Access

    Physicochemical characterization, determination of total concentration and estimation of bioaccessible fraction of elements in fruit functional flours

    by Gabriel di Giovani Belinati, Heloisa Mariano Pedroso de Carvalho, Eduardo Leite de Almeida, Ana Rita de Araújo Nogueira, Alex Virgilio


  • Open Access

    A convective heated digestion system with closed vessels: a new digestor for elemental inorganic analysis

    by Alan Lima Vieira, Gabriel Gustinelli Arantes de Carvalho, José Anchieta Gomes Neto, Pedro Vitoriano Oliveira, Marcos Yassuo Kamogawa, Alex Virgilio

    This work presents a new, robust, and reliable conductively heated digestion system with closed vessels (CHDS) for the preparation of plant materials for elemental determination by inductively coupled plasma optical emission spectrometry (ICP OES). The proposed system combines the simplicity of a 24-slot resistively heated aluminum block with the key advantages inherent to closed vessels. Fundamental studies on temperature and pressure were also performed and the difference between the liquid phase temperature (190 °C) and the aluminum block temperature (240 °C) was assigned to the dynamic condensation of the gaseous phase during digestion. The optimized digestion procedure was achieved for 250 mg test portions, 2.0 mL of HNO3 (65% v v−1), 1.5 mL of H2O2 (30% v v−1), and a temperature of 240 °C, with a heating rate of 10 °C min−1 and dwell time of 20 min. Under these conditions, the residual carbon contents in digests were generally below 700 mg L−1. The performance of the CHDS was checked by analyzing plant certified reference materials and the determined concentrations of B, Ca, Cu, Fe, K, Mg, Mn, P, S, and Zn presented no significant differences when compared to the certified values at the 95% confidence level. Recoveries in the 75–108% range and relative standard deviations ≤3% (n = 3) were typically obtained. Also, the system was applied to the analysis of sixteen samples from an interlaboratory trial, and a comparison with alternative single reaction chamber microwave-assisted digestion (SRC MWAD) and open vessel nitro-perchloric decomposition (NP) digestion methods also showed equivalence at a 95% confidence level in most cases. The CHDS system based on thermally convective heating allowed digestion of up to 24 different plant materials in ca. 50 min, but it is not limited to samples and analytes chosen in this work: the CHDS is designed for typical use in elemental inorganic analysis techniques that require liquid-based sample introduction.


  • Direct Determination of the Aluminum Content in Antiperspirants Using Digital Image Colorimetry

    by Gustavo G. Teixeira, Alex Virgilio, Poliana M. Santos

    In this work a dilute‐and‐shoot procedure using digital image colorimetry (DIC) was evaluated for the determination of aluminum in antiperspirants. Derivatization was performed by means of the reaction between Al(III) and Alizarin Red S (ARS) reagent. Digital images were acquired using a table scanner and the average values for red, green and blue channels (RGB) were obtained. Optimal conditions were set at pH=4.5, ARS concentrations 10‐fold higher than Al(III) and using the G channel. The method presented linearity in the 2.0–10.0 mg L −1 range, the limit of detection (LOD) was 1.1 mg L −1 and precision was better than 2.55 %. Accuracy was checked by the analysis of spiked samples at 2.0 and 4.0 mg L −1 Al(III), and good recoveries (82.6–117.5 %) were obtained. Eight samples of roll‐on antiperspirants were analyzed by the proposed colorimetric method and the well‐stablished flame atomic absorption spectrometry (FAAS) comparative method. The obtained results were not statistically different at 95 % confidence level. An analytical greenness assessment was performed for both methods and the procedure based on digital image colorimetry was proven to be a greener approach due to miniaturization, low sample consumption, least amount of waste and high sample throughput.


  • Closed-Vessel Conductively Heated Digestion of Dry Dog Food for Spectrometric Determination of Essential Nutrients

    by Rayane Costa, João Victor Santiago, Edilene Ferreira, Alex Virgilio, José Anchieta Gomes Neto

    The closed-vessel conductively heated digestion system (CHDS) was evaluated to digest dry dog foods for further determination of K, Na, Cu, Fe, Mn, and Zn by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The CHDS method was optimized using a fractional factorial design with five variables (HNO3 concentration, H2O2 volume, temperature, holding time, and pre-digestion time) at two levels. The accuracy of the CHDS procedure was checked by the analysis of reference materials from the National Institute of Standards and Technology (NIST SRM 1577b Bovine Liver and 2976 Mussel Tissue) and Brazilian Agricultural Research Corporation (Embrapa MR-E1002A Fish Food). Also, the digestion efficiencies were calculated from residual carbon contents (RCCs). The RCC and blank values in the CHDS digested samples were consistently low, which is suitable for determinations using ICP OES and ICP-MS techniques. For comparison, all samples were also digested by microwave-assisted digestion in closed vessels (MW-AD). Results for Na, K, Cu, Fe, Mn, and Zn determined in sample digests obtained by CHDS were not statistically different at a 95% confidence level from those observed for MW-AD. Limits of quantification (LOQ) calculated from digests in CHDS and MW-AD were comparable, and the values provided adequate limits for elemental determinations in dog foods. Data from mineral composition and moisture were employed in a clustering analysis (HCA) and the discrimination of the samples among different manufacturers and food for dogs at different life stages was possible.


  • Closed-Vessel Conductively Heated Digestion System for the Elemental Analysis of Agricultural Materials by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS)

    by Leonardo Clemente Traversa, João Victor Biagi Santiago, Evilim Martinez de Oliveira, Edilene Cristina Ferreira, Alex Virgilio, José Anchieta Gomes Neto

    Novel applications of the closed-vessel conductively heated digestion system (CHDS) are proposed to digest biomass, biochar, oyster shell flour, bone meal and swine manure for the determination of Ca, K, Mg, Na, Cu, Fe, Mn, and Zn by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The performance of the digestion method using 14 and 7 mol L−1 HNO3 was checked by analyzing soil, rock, and plant certified reference materials (CRMs). For comparative purposes, all samples were analyzed after microwave-assisted digestion (MW-AD). Results obtained for most analytes by the closed-vessel conductively heated digestion system (CHDS) were in agreement with certified values and those attained by the comparative digestion method. The use of 7 mol L−1 HNO3 furnished lower blanks for most analytes and was effective to prepare challenging samples as biomass, biochar, shell and bone meal, swine manure, plants, soil, phosphate rock, and may be a good alternative for elemental determinations using most analytical techniques that rely on solution-based sample introduction systems. The detection limits (dry basis, mg kg−1) for Ca, Cu, Fe, K, Mg, Mn, Na, and Zn were 3, 0.4, 4, 4, 0.7, 0.4, 3, and 2, respectively. The mean relative standard deviations were close to 4.9% for closed-vessel conductively heated digestion (CHDS) and 5.9% for microwave-assisted digestion (MW-AD). Graphical Abstract


  • Calculating limits of detection and defining working ranges for multi-signal calibration methods

    by Alex Virgilio, Ana Beatriz S. Silva, Ana Rita A. Nogueira, Joaquim A. Nóbrega, George L. Donati

    Multi-signal calibration methods, such as multi-energy calibration (MEC) and multi-isotope calibration (MICal), have increasingly been used to improve the efficiency of spectrochemical instrumental analyses. As MEC and MICal are adopted by an increasing number of laboratories, questions on their working ranges, the most appropriate calibration standard concentration (Cstd) to be used, and the best approach to calculate limits of detection (LOD) and quantification (LOQ) have been raised. In this study, we evaluate the effects of working with different combinations of Cstd and analyte concentration in the sample (Csam) on the accuracy of MEC and MICal. Chromium, Cu and Mo are used as models for MEC determinations by microwave-induced plasma optical emission spectrometry (MIP OES) and inductively coupled plasma OES (ICP OES), and MICal determinations by ICP mass spectrometry (ICP-MS), respectively. We use the error propagation approach to determine LODs and LOQs, evaluate the effect of employing different values of Cstd in these calculations, and compare the results with those from external standard calibration (EC) using the IUPAC approach. Finally, we apply MEC and MICal to analyze certified reference materials and compare the results with those from the traditional standard additions (SA) method. Although presenting usually higher LODs and LOQs compared to EC, MEC and MICal generally provide trueness similar to, and sometimes better than, SA. LOD and LOQ calculations based on the error propagation approach provide robust results, and trueness and precision depend on the calibration slope and the analyte level in the sample. The best results for MEC and MICal are found when working within the 0.1 < calibration slope < 0.9 range. A simple pre-analysis test comparing the analytical signal recorded for the sample (Isam) and a calibration standard (Istd) may ensure such conditions if 0.11 < Isam/Istd < 9.00. MEC and MICal are simple and efficient alternatives to EC and SA. They are particularly effective for minimizing matrix effects and analyzing complex-matrix samples.