José Anchieta Gomes Neto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
José Anchieta Gomes Neto has a total of 115 co-authors. Here are the top co-authors by number of shared publications:
- Joaquim Araújo Nobrega
Universidade Federal de São Carlos
12 shared publications - Edilene Cristina Ferreira
Institute of Chemistry, São Paulo State University (UNESP), Araraquara City, 14800-060, São Paulo State, Brazil
9 shared publications Mercedes de Moraes
Universidade Estadual Paulista, Araraquara, Brazil
8 shared publications- Silvana Ruella Oliveira
Federal Institute for Materials Research and Testing (BAM), Division 1.1-Inorganic Trace Analysis (ITALab), Berlin, Germany
7 shared publications - Alex Virgilio
Universidade de São Paulo
5 shared publications Edilene Cristina Ferreira
Analytical, Inorganic and Physical-Chemistry Department, UNESP-São Paulo State University, Araraquara, Brazil
5 shared publications
Latest Publications
- 4 November 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (11) , 3806-3816
Evaluation of a 3D-printed polymeric platform for the determination of Pd, Pt, and Ru in cancer cells by SS HR-CS GF AAS
A low-cost disposable PLA platform fabricated by 3D printing provides accurate determination of Pd, Pt and Ru in cancer cells by HR-CS GF AAS while reducing dependence on conventional graphite platforms.
- 4 November 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (11) , 3806-3816
Evaluation of a 3D-printed polymeric platform for the determination of Pd, Pt, and Ru in cancer cells by SS HR-CS GF AAS
A low-cost disposable PLA platform fabricated by 3D printing provides accurate determination of Pd, Pt and Ru in cancer cells by HR-CS GF AAS while reducing dependence on conventional graphite platforms.
- 1 April 2026
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Evaluation of Closed-Vessel Conductively-Heated Digestion System with Diluted Acid for Analysis of Animal Feed by ICP-MS
A conductively-heated digestion system (CHDS) with closed-vessel and diluted acid was evaluated for the preparation of animal feed for subsequent determination of As, Cd, Mo, Ni, Pb, Se and V by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The analytical performance of the digestor was checked by analyzing fish tissue, tuna and corn bran certified reference materials (CRMs) using 1 mL of 30% (w w-1) hydrogen peroxide plus 2 mL of nitric acid at 14, 7 and 3.5 mol L-1 HNO3. The recoveries of analytes in CRMs digested at different acid concentrations varied from 80 – 116% (3.5 mol L⁻¹ HNO₃) 86 – 118% (7 mol L⁻¹ HNO₃) e 80 – 123% (14 mol L⁻¹ HNO₃). The method was applied to real animal feed samples, and the CHDS results were like those of comparative microwave digestion (MWD). Quantification limits of analytes found by CHDS and MWD were also similar, concerning different acid concentrations. However, the use of diluted nitric acid in the preparation of animal feed samples proved to be a viable and efficient approach, allowing lower residual acidity, reduction in reagent consumption and acid waste generation, in accordance with the principles of Green Chemistry.
- 1 April 2026
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Evaluation of Closed-Vessel Conductively-Heated Digestion System with Diluted Acid for Analysis of Animal Feed by ICP-MS
A conductively-heated digestion system (CHDS) with closed-vessel and diluted acid was evaluated for the preparation of animal feed for subsequent determination of As, Cd, Mo, Ni, Pb, Se and V by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The analytical performance of the digestor was checked by analyzing fish tissue, tuna and corn bran certified reference materials (CRMs) using 1 mL of 30% (w w-1) hydrogen peroxide plus 2 mL of nitric acid at 14, 7 and 3.5 mol L-1 HNO3. The recoveries of analytes in CRMs digested at different acid concentrations varied from 80 – 116% (3.5 mol L⁻¹ HNO₃) 86 – 118% (7 mol L⁻¹ HNO₃) e 80 – 123% (14 mol L⁻¹ HNO₃). The method was applied to real animal feed samples, and the CHDS results were like those of comparative microwave digestion (MWD). Quantification limits of analytes found by CHDS and MWD were also similar, concerning different acid concentrations. However, the use of diluted nitric acid in the preparation of animal feed samples proved to be a viable and efficient approach, allowing lower residual acidity, reduction in reagent consumption and acid waste generation, in accordance with the principles of Green Chemistry.
- 27 March 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (5) , 1231-1240
Multi-laser-power calibration for quantitative determination of N and P in fertilizers by Raman spectroscopy
A new method called multi-laser-power calibration (MLPC) is described for quantitative analysis by Raman spectroscopy. MLPC is based on the premise that, under controlled operating conditions, the intensity of Raman spectroscopy signals for a given analyte is directly proportional to the laser power applied to generate that signal. Different from traditional methods, in which calibration is performed by varying analyte concentrations while keeping instrumental parameters fixed, MLPC uses a single calibration standard and different laser applied powers to generate several calibration points. Samples and standard solution are measured under identical conditions, and multiple scattering intensities (I) are generated by varying the Raman's laser applied power (P). The MLPC curve is built with I values for the calibration standard (Istd) on the x axis and the respective values for the sample (Isample) on the y axis. The analyte concentration in the sample (Csample) is then calculated from the calibration curve slope (m). As a proof-of-concept, the MLPC method was applied for the determination of N and P species in fertilizer and raw material samples using a 30 s exposition time and laser applied powers in the 35–319 mW range. Calibration curves with correlation coefficients greater than 0.9986 were consistently obtained. The method's accuracy was evaluated by analyzing three certified reference materials of fertilizer. MLPC results were in agreement with reference values at a 95% confidence level (t-test). Ten commercially available fertilizer and raw material samples were also analyzed, and the results were compared with values obtained by both Raman spectroscopy using external standard calibration (EC-Raman), and official methods based on Kjeldahl and spectrophotometry. Limits of quantification (dry mass, % w/w) for phosphate, phosphite, urea, and nitrate were calculated as 0.03, 0.09, 0.04, 0.05, respectively. Relative standard deviations (RSDs) were 10%, 7%, 11%, and 3% (9%, 4%, 9%, and 2% for EC), respectively, for these analytes. Total N and total P determination by Kjeldahl and spectrophotometry had RSDs of 4% and 10%, respectively. The MLPC method using 5000 mg L−1 single calibration standards was successfully used to speciate N and P in fertilizer analyses.
- 27 March 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (5) , 1231-1240
Multi-laser-power calibration for quantitative determination of N and P in fertilizers by Raman spectroscopy
A new method called multi-laser-power calibration (MLPC) is described for quantitative analysis by Raman spectroscopy. MLPC is based on the premise that, under controlled operating conditions, the intensity of Raman spectroscopy signals for a given analyte is directly proportional to the laser power applied to generate that signal. Different from traditional methods, in which calibration is performed by varying analyte concentrations while keeping instrumental parameters fixed, MLPC uses a single calibration standard and different laser applied powers to generate several calibration points. Samples and standard solution are measured under identical conditions, and multiple scattering intensities (I) are generated by varying the Raman's laser applied power (P). The MLPC curve is built with I values for the calibration standard (Istd) on the x axis and the respective values for the sample (Isample) on the y axis. The analyte concentration in the sample (Csample) is then calculated from the calibration curve slope (m). As a proof-of-concept, the MLPC method was applied for the determination of N and P species in fertilizer and raw material samples using a 30 s exposition time and laser applied powers in the 35–319 mW range. Calibration curves with correlation coefficients greater than 0.9986 were consistently obtained. The method's accuracy was evaluated by analyzing three certified reference materials of fertilizer. MLPC results were in agreement with reference values at a 95% confidence level (t-test). Ten commercially available fertilizer and raw material samples were also analyzed, and the results were compared with values obtained by both Raman spectroscopy using external standard calibration (EC-Raman), and official methods based on Kjeldahl and spectrophotometry. Limits of quantification (dry mass, % w/w) for phosphate, phosphite, urea, and nitrate were calculated as 0.03, 0.09, 0.04, 0.05, respectively. Relative standard deviations (RSDs) were 10%, 7%, 11%, and 3% (9%, 4%, 9%, and 2% for EC), respectively, for these analytes. Total N and total P determination by Kjeldahl and spectrophotometry had RSDs of 4% and 10%, respectively. The MLPC method using 5000 mg L−1 single calibration standards was successfully used to speciate N and P in fertilizer analyses.
- Open Access
- 18 February 2025
- Published by American Chemical Society (ACS) in Inorganic Chemistry
- Vol. 64 (8) , 3707-3718
Ru(II)-Fenamic-Based Complexes as Promising Human Ovarian Antitumor Agents: DNA Interaction, Cellular Uptake, and Three-Dimensional Spheroid Models
Cancer resistance to chemotherapeutic agents such as cisplatin presents a significant challenge, leading to treatment failure and poor outcomes. Novel metal-based compounds offer a promising strategy to overcome drug resistance and to enhance efficacy. Four Ru(II) complexes with fenamic acid derivatives were synthesized and characterized: [Ru(L)(bipy)(dppp)]PF6, where L represents fenamic acid (HFen, complex 1), mefenamic acid (HMFen, complex 2), tolfenamic acid (HTFen, complex 3), and flufenamic acid (HFFen, complex 4). Their composition was supported by molar conductivity, elemental analysis, Fourier transform infrared spectroscopy, ultraviolet-visible spectroscopy, mass spectrometry, and 31P{1H}, 1H, and 13C nuclear magnetic resonance, with the crystal structure of complex 1 confirmed via X-ray diffraction. Complexes 1-4 exhibited notable cytotoxicity against tested cell lines, particularly A2780 and A2780cisR (cisplatin-resistant ovarian tumors), compared to MDA-MB-231 (breast) and A549 (lung) lines. Mechanistic studies revealed weak DNA interactions through minor grooves or electrostatic binding. Cellular uptake assays showed effective internalization of complexes 1 (3.6%) and 2 (4.5%), correlating with potent IC50 values. These complexes also altered cell morphology, reduced cell density, and inhibited colony formation in the A2780 cells. Staining assays indicated induced cell death and organelle damage, highlighting their potential as promising antitumor agents.
- 18 February 2025
- Published by American Chemical Society (ACS) in Inorganic Chemistry
- Vol. 64 (8) , 3707-3718
Open AccessRu(II)-Fenamic-Based Complexes as Promising Human Ovarian Antitumor Agents: DNA Interaction, Cellular Uptake, and Three-Dimensional Spheroid Models
Cancer resistance to chemotherapeutic agents such as cisplatin presents a significant challenge, leading to treatment failure and poor outcomes. Novel metal-based compounds offer a promising strategy to overcome drug resistance and to enhance efficacy. Four Ru(II) complexes with fenamic acid derivatives were synthesized and characterized: [Ru(L)(bipy)(dppp)]PF6, where L represents fenamic acid (HFen, complex 1), mefenamic acid (HMFen, complex 2), tolfenamic acid (HTFen, complex 3), and flufenamic acid (HFFen, complex 4). Their composition was supported by molar conductivity, elemental analysis, Fourier transform infrared spectroscopy, ultraviolet-visible spectroscopy, mass spectrometry, and 31P{1H}, 1H, and 13C nuclear magnetic resonance, with the crystal structure of complex 1 confirmed via X-ray diffraction. Complexes 1-4 exhibited notable cytotoxicity against tested cell lines, particularly A2780 and A2780cisR (cisplatin-resistant ovarian tumors), compared to MDA-MB-231 (breast) and A549 (lung) lines. Mechanistic studies revealed weak DNA interactions through minor grooves or electrostatic binding. Cellular uptake assays showed effective internalization of complexes 1 (3.6%) and 2 (4.5%), correlating with potent IC50 values. These complexes also altered cell morphology, reduced cell density, and inhibited colony formation in the A2780 cells. Staining assays indicated induced cell death and organelle damage, highlighting their potential as promising antitumor agents.
- Open Access
- 20 December 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (2) , 356-363
A convective heated digestion system with closed vessels: a new digestor for elemental inorganic analysis
This work presents a new, robust, and reliable conductively heated digestion system with closed vessels (CHDS) for the preparation of plant materials for elemental determination by inductively coupled plasma optical emission spectrometry (ICP OES). The proposed system combines the simplicity of a 24-slot resistively heated aluminum block with the key advantages inherent to closed vessels. Fundamental studies on temperature and pressure were also performed and the difference between the liquid phase temperature (190 °C) and the aluminum block temperature (240 °C) was assigned to the dynamic condensation of the gaseous phase during digestion. The optimized digestion procedure was achieved for 250 mg test portions, 2.0 mL of HNO3 (65% v v−1), 1.5 mL of H2O2 (30% v v−1), and a temperature of 240 °C, with a heating rate of 10 °C min−1 and dwell time of 20 min. Under these conditions, the residual carbon contents in digests were generally below 700 mg L−1. The performance of the CHDS was checked by analyzing plant certified reference materials and the determined concentrations of B, Ca, Cu, Fe, K, Mg, Mn, P, S, and Zn presented no significant differences when compared to the certified values at the 95% confidence level. Recoveries in the 75–108% range and relative standard deviations ≤3% (n = 3) were typically obtained. Also, the system was applied to the analysis of sixteen samples from an interlaboratory trial, and a comparison with alternative single reaction chamber microwave-assisted digestion (SRC MWAD) and open vessel nitro-perchloric decomposition (NP) digestion methods also showed equivalence at a 95% confidence level in most cases. The CHDS system based on thermally convective heating allowed digestion of up to 24 different plant materials in ca. 50 min, but it is not limited to samples and analytes chosen in this work: the CHDS is designed for typical use in elemental inorganic analysis techniques that require liquid-based sample introduction.
- 20 December 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (2) , 356-363
Open AccessA convective heated digestion system with closed vessels: a new digestor for elemental inorganic analysis
This work presents a new, robust, and reliable conductively heated digestion system with closed vessels (CHDS) for the preparation of plant materials for elemental determination by inductively coupled plasma optical emission spectrometry (ICP OES). The proposed system combines the simplicity of a 24-slot resistively heated aluminum block with the key advantages inherent to closed vessels. Fundamental studies on temperature and pressure were also performed and the difference between the liquid phase temperature (190 °C) and the aluminum block temperature (240 °C) was assigned to the dynamic condensation of the gaseous phase during digestion. The optimized digestion procedure was achieved for 250 mg test portions, 2.0 mL of HNO3 (65% v v−1), 1.5 mL of H2O2 (30% v v−1), and a temperature of 240 °C, with a heating rate of 10 °C min−1 and dwell time of 20 min. Under these conditions, the residual carbon contents in digests were generally below 700 mg L−1. The performance of the CHDS was checked by analyzing plant certified reference materials and the determined concentrations of B, Ca, Cu, Fe, K, Mg, Mn, P, S, and Zn presented no significant differences when compared to the certified values at the 95% confidence level. Recoveries in the 75–108% range and relative standard deviations ≤3% (n = 3) were typically obtained. Also, the system was applied to the analysis of sixteen samples from an interlaboratory trial, and a comparison with alternative single reaction chamber microwave-assisted digestion (SRC MWAD) and open vessel nitro-perchloric decomposition (NP) digestion methods also showed equivalence at a 95% confidence level in most cases. The CHDS system based on thermally convective heating allowed digestion of up to 24 different plant materials in ca. 50 min, but it is not limited to samples and analytes chosen in this work: the CHDS is designed for typical use in elemental inorganic analysis techniques that require liquid-based sample introduction.
- 2 June 2023
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Closed-Vessel Conductively Heated Digestion of Dry Dog Food for Spectrometric Determination of Essential Nutrients
The closed-vessel conductively heated digestion system (CHDS) was evaluated to digest dry dog foods for further determination of K, Na, Cu, Fe, Mn, and Zn by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The CHDS method was optimized using a fractional factorial design with five variables (HNO3 concentration, H2O2 volume, temperature, holding time, and pre-digestion time) at two levels. The accuracy of the CHDS procedure was checked by the analysis of reference materials from the National Institute of Standards and Technology (NIST SRM 1577b Bovine Liver and 2976 Mussel Tissue) and Brazilian Agricultural Research Corporation (Embrapa MR-E1002A Fish Food). Also, the digestion efficiencies were calculated from residual carbon contents (RCCs). The RCC and blank values in the CHDS digested samples were consistently low, which is suitable for determinations using ICP OES and ICP-MS techniques. For comparison, all samples were also digested by microwave-assisted digestion in closed vessels (MW-AD). Results for Na, K, Cu, Fe, Mn, and Zn determined in sample digests obtained by CHDS were not statistically different at a 95% confidence level from those observed for MW-AD. Limits of quantification (LOQ) calculated from digests in CHDS and MW-AD were comparable, and the values provided adequate limits for elemental determinations in dog foods. Data from mineral composition and moisture were employed in a clustering analysis (HCA) and the discrimination of the samples among different manufacturers and food for dogs at different life stages was possible.
- 2 June 2023
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Closed-Vessel Conductively Heated Digestion of Dry Dog Food for Spectrometric Determination of Essential Nutrients
The closed-vessel conductively heated digestion system (CHDS) was evaluated to digest dry dog foods for further determination of K, Na, Cu, Fe, Mn, and Zn by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The CHDS method was optimized using a fractional factorial design with five variables (HNO3 concentration, H2O2 volume, temperature, holding time, and pre-digestion time) at two levels. The accuracy of the CHDS procedure was checked by the analysis of reference materials from the National Institute of Standards and Technology (NIST SRM 1577b Bovine Liver and 2976 Mussel Tissue) and Brazilian Agricultural Research Corporation (Embrapa MR-E1002A Fish Food). Also, the digestion efficiencies were calculated from residual carbon contents (RCCs). The RCC and blank values in the CHDS digested samples were consistently low, which is suitable for determinations using ICP OES and ICP-MS techniques. For comparison, all samples were also digested by microwave-assisted digestion in closed vessels (MW-AD). Results for Na, K, Cu, Fe, Mn, and Zn determined in sample digests obtained by CHDS were not statistically different at a 95% confidence level from those observed for MW-AD. Limits of quantification (LOQ) calculated from digests in CHDS and MW-AD were comparable, and the values provided adequate limits for elemental determinations in dog foods. Data from mineral composition and moisture were employed in a clustering analysis (HCA) and the discrimination of the samples among different manufacturers and food for dogs at different life stages was possible.
- 6 February 2023
- Published by Taylor & Francis in Analytical Letters
- Vol. 56 (15) , 2443-2456
Closed-Vessel Conductively Heated Digestion System for the Elemental Analysis of Agricultural Materials by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS)
Novel applications of the closed-vessel conductively heated digestion system (CHDS) are proposed to digest biomass, biochar, oyster shell flour, bone meal and swine manure for the determination of Ca, K, Mg, Na, Cu, Fe, Mn, and Zn by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The performance of the digestion method using 14 and 7 mol L−1 HNO3 was checked by analyzing soil, rock, and plant certified reference materials (CRMs). For comparative purposes, all samples were analyzed after microwave-assisted digestion (MW-AD). Results obtained for most analytes by the closed-vessel conductively heated digestion system (CHDS) were in agreement with certified values and those attained by the comparative digestion method. The use of 7 mol L−1 HNO3 furnished lower blanks for most analytes and was effective to prepare challenging samples as biomass, biochar, shell and bone meal, swine manure, plants, soil, phosphate rock, and may be a good alternative for elemental determinations using most analytical techniques that rely on solution-based sample introduction systems. The detection limits (dry basis, mg kg−1) for Ca, Cu, Fe, K, Mg, Mn, Na, and Zn were 3, 0.4, 4, 4, 0.7, 0.4, 3, and 2, respectively. The mean relative standard deviations were close to 4.9% for closed-vessel conductively heated digestion (CHDS) and 5.9% for microwave-assisted digestion (MW-AD). Graphical Abstract
- 6 February 2023
- Published by Taylor & Francis in Analytical Letters
- Vol. 56 (15) , 2443-2456
Closed-Vessel Conductively Heated Digestion System for the Elemental Analysis of Agricultural Materials by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS)
Novel applications of the closed-vessel conductively heated digestion system (CHDS) are proposed to digest biomass, biochar, oyster shell flour, bone meal and swine manure for the determination of Ca, K, Mg, Na, Cu, Fe, Mn, and Zn by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The performance of the digestion method using 14 and 7 mol L−1 HNO3 was checked by analyzing soil, rock, and plant certified reference materials (CRMs). For comparative purposes, all samples were analyzed after microwave-assisted digestion (MW-AD). Results obtained for most analytes by the closed-vessel conductively heated digestion system (CHDS) were in agreement with certified values and those attained by the comparative digestion method. The use of 7 mol L−1 HNO3 furnished lower blanks for most analytes and was effective to prepare challenging samples as biomass, biochar, shell and bone meal, swine manure, plants, soil, phosphate rock, and may be a good alternative for elemental determinations using most analytical techniques that rely on solution-based sample introduction systems. The detection limits (dry basis, mg kg−1) for Ca, Cu, Fe, K, Mg, Mn, Na, and Zn were 3, 0.4, 4, 4, 0.7, 0.4, 3, and 2, respectively. The mean relative standard deviations were close to 4.9% for closed-vessel conductively heated digestion (CHDS) and 5.9% for microwave-assisted digestion (MW-AD). Graphical Abstract
- Open Access
Rice Labeling according to Grain Quality Features Using Laser-Induced Breakdown Spectroscopy
Rice is an important source of nutrition and energy consumed around the world. Thus, quality inspection is crucial for protecting consumers and increasing the rice’s value in the productive chain. Currently, methods for rice labeling depending on grain quality features are based on image and/or visual inspection. These methods have shown subjectivity and inefficiency for large-scale analyses. Laser-induced breakdown spectroscopy (LIBS) is an analytical technique showing attractive features due to how quick the analysis can be carried out and its capability of providing spectra that are true fingerprints of the sample’s elemental composition. In this work, LIBS performance was evaluated for labeling rice according to grain quality features. The LIBS spectra of samples with their grain quality numerically described as Type 1, 2, and 3 were measured. Several spectral processing methods were evaluated when modeling a k-nearest neighbors (k-NN) classifier. Variable selection was also carried out by principal component analysis (PCA), and then the optimal k-value was selected. The best result was obtained by applying spectrum smoothing followed by normalization by using the first fifteen principal components (PCs) as input variables and k = 9. Under these conditions, the method showed excellent performance, achieving sample classification with 94% overall prediction accuracy. The sensitivities ranged from 90 to 100%, and specificities were in the range of 92–100%. The proposed method has remarkable characteristics, e.g., analytical speed and analysis guided by chemical responses; therefore, the method is not susceptible to subjectivity errors.
Open AccessRice Labeling according to Grain Quality Features Using Laser-Induced Breakdown Spectroscopy
Rice is an important source of nutrition and energy consumed around the world. Thus, quality inspection is crucial for protecting consumers and increasing the rice’s value in the productive chain. Currently, methods for rice labeling depending on grain quality features are based on image and/or visual inspection. These methods have shown subjectivity and inefficiency for large-scale analyses. Laser-induced breakdown spectroscopy (LIBS) is an analytical technique showing attractive features due to how quick the analysis can be carried out and its capability of providing spectra that are true fingerprints of the sample’s elemental composition. In this work, LIBS performance was evaluated for labeling rice according to grain quality features. The LIBS spectra of samples with their grain quality numerically described as Type 1, 2, and 3 were measured. Several spectral processing methods were evaluated when modeling a k-nearest neighbors (k-NN) classifier. Variable selection was also carried out by principal component analysis (PCA), and then the optimal k-value was selected. The best result was obtained by applying spectrum smoothing followed by normalization by using the first fifteen principal components (PCs) as input variables and k = 9. Under these conditions, the method showed excellent performance, achieving sample classification with 94% overall prediction accuracy. The sensitivities ranged from 90 to 100%, and specificities were in the range of 92–100%. The proposed method has remarkable characteristics, e.g., analytical speed and analysis guided by chemical responses; therefore, the method is not susceptible to subjectivity errors.
- 27 August 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (36) , 3486-3492
Characterization and predictive modeling potential of aging time of roasted coffee using infrared spectroscopy
Repackaging and tampering with labels of foods to extend their shelf life is an illegal practice, increasingly common in some Brazilian coffee retail markets. Fast, easy-to-use, and low-cost analytical techniques for the large-scale screening of aging time have been demanded lately to fight the growth of these frauds in retail coffee markets. In this work, Fourier transform infrared spectroscopy was evaluated as a provider of relevant regressors, chemically explainable, aiming for predictive models for estimating the aging of roasted and packaged coffees during their shelf life. Spectra of two Coffea arabica varieties (Bourbon and Obatã) were periodically acquired during eleven months of storage. The most relevant absorption bands were selected, which showed a moderate correlation with the storage time. They were identified as responses from lipids, phenolic compounds, and carbohydrates. From those responsive bands, logistic regression (sigmoid functions) models were fitted for each coffee variety, as well as for both together. Predictive models for Bourbon and Obatã showed high performances in validation data, with r (Pearson correlation) above 0.92 and root mean square error (RMSE) below 43 days. For both varieties, the logistic model showed r greater than 0.83 and RMSE equal to 56 days. Results corroborate the methodological approach efficacy towards agile technological innovations in the coffee value chain, as well as opening new application fronts for estimating the aging of other foods.
- 27 August 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (36) , 3486-3492
Characterization and predictive modeling potential of aging time of roasted coffee using infrared spectroscopy
Repackaging and tampering with labels of foods to extend their shelf life is an illegal practice, increasingly common in some Brazilian coffee retail markets. Fast, easy-to-use, and low-cost analytical techniques for the large-scale screening of aging time have been demanded lately to fight the growth of these frauds in retail coffee markets. In this work, Fourier transform infrared spectroscopy was evaluated as a provider of relevant regressors, chemically explainable, aiming for predictive models for estimating the aging of roasted and packaged coffees during their shelf life. Spectra of two Coffea arabica varieties (Bourbon and Obatã) were periodically acquired during eleven months of storage. The most relevant absorption bands were selected, which showed a moderate correlation with the storage time. They were identified as responses from lipids, phenolic compounds, and carbohydrates. From those responsive bands, logistic regression (sigmoid functions) models were fitted for each coffee variety, as well as for both together. Predictive models for Bourbon and Obatã showed high performances in validation data, with r (Pearson correlation) above 0.92 and root mean square error (RMSE) below 43 days. For both varieties, the logistic model showed r greater than 0.83 and RMSE equal to 56 days. Results corroborate the methodological approach efficacy towards agile technological innovations in the coffee value chain, as well as opening new application fronts for estimating the aging of other foods.