Zikai Hua
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zikai Hua has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Leiming Gao
Department of Engineering, Nottingham Trent University, Nottingham NG1 4FQ, UK
4 shared publications Xiuling Huang
School of Mechatronics Engineering and Automation, Shanghai University, Shanghai, China
4 shared publicationsDongxu Liu
School of Mechatronics Engineering and Automation, Shanghai University, Shanghai, PR China
3 shared publicationsJunjun Zhu
Shanghai Univ, Sch Mech Engn & Automat, Shanghai 200444, Peoples R China
3 shared publicationsWanmei Yang
Department of Orthopedics, Fuyang People's Hospital, Fuyang, Anhui, China
3 shared publicationsXilong Cui
School of Mechatronics Engineering and Automation, Shanghai University, Shanghai, China
3 shared publications
Latest Publications
- Open Access
- 24 April 2026
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 12 (2) , 026050035
Neuromodulation with a 3D-printed, patient-specific hand orthotic in stroke: A proof-of-concept fMRI case series on clinical application
Three-dimensional (3D) printing holds great promise for creating patient-specific rehabilitative devices. While previous studies have demonstrated that behavioral interventions can induce cortical reorganization in stroke, direct evidence that a device alone—specifically, a patient-specific 3D-printed orthotic—can modulate brain function remains lacking. This proof-of-concept case series bridges this gap by integrating a complete digital workflow—from upper limb 3D scanning to stereolithography (SLA) fabrication of a custom hand orthotic—with longitudinal multimodal functional magnetic resonance imaging (fMRI) to assess cortical reorganization in chronic stroke. Four patients participated, with two index cases wearing the 3D-printed orthosis daily for four months alongside conventional rehabilitation, while two reference patients underwent conventional therapy only. Pre- and post-intervention neuroimaging revealed consistent, orthosis-associated neural changes: enhanced activity in the primary somatosensory cortex and greater functional integration within sensorimotor networks. Structural adaptations in motor regions were also observed in both index cases. Quantitatively, the index cases exhibited functional changes in nine brain regions and structural changes in six regions, substantially exceeding the minimal changes observed in the reference cases. This work provides the first direct evidence that a 3D-printed, patient-specific orthotic can drive targeted neuroplasticity independent of intensive behavioral coaching, validating its role not merely as a passive assistive device but as an active neuromodulatory tool. It establishes a translational framework for using objective neuroimaging biomarkers to guide the development and personalization of 3D-printed interventions in neurorehabilitation.
- 24 April 2026
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 12 (2) , 026050035
Open AccessNeuromodulation with a 3D-printed, patient-specific hand orthotic in stroke: A proof-of-concept fMRI case series on clinical application
Three-dimensional (3D) printing holds great promise for creating patient-specific rehabilitative devices. While previous studies have demonstrated that behavioral interventions can induce cortical reorganization in stroke, direct evidence that a device alone—specifically, a patient-specific 3D-printed orthotic—can modulate brain function remains lacking. This proof-of-concept case series bridges this gap by integrating a complete digital workflow—from upper limb 3D scanning to stereolithography (SLA) fabrication of a custom hand orthotic—with longitudinal multimodal functional magnetic resonance imaging (fMRI) to assess cortical reorganization in chronic stroke. Four patients participated, with two index cases wearing the 3D-printed orthosis daily for four months alongside conventional rehabilitation, while two reference patients underwent conventional therapy only. Pre- and post-intervention neuroimaging revealed consistent, orthosis-associated neural changes: enhanced activity in the primary somatosensory cortex and greater functional integration within sensorimotor networks. Structural adaptations in motor regions were also observed in both index cases. Quantitatively, the index cases exhibited functional changes in nine brain regions and structural changes in six regions, substantially exceeding the minimal changes observed in the reference cases. This work provides the first direct evidence that a 3D-printed, patient-specific orthotic can drive targeted neuroplasticity independent of intensive behavioral coaching, validating its role not merely as a passive assistive device but as an active neuromodulatory tool. It establishes a translational framework for using objective neuroimaging biomarkers to guide the development and personalization of 3D-printed interventions in neurorehabilitation.
- Open Access
- 17 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 67-73
Prediction and Experimental Validation of Wear Zones in Artificial Ligaments Based on Finite Element Stress Analysis
- 17 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 67-73
Open AccessPrediction and Experimental Validation of Wear Zones in Artificial Ligaments Based on Finite Element Stress Analysis
- 14 October 2025
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 54 (2) , 345-356
Applicability of ASTM F543-23-A2 Standards Across Diverse Bone Screw Types
ASTM F543-23-A2, Standard Specification and Test Methods for Metallic Medical Bone Screws, provides critical experiential data on the torque required by surgeons when securing screws in clinical settings. This study aimed to evaluate the universal applicability of ASTM standard default testing parameters in assessing a wide variety of screws. A total of 131 screws, spanning 24 types, were selected and tested following ASTM F543-23-A2 guidelines, with the insertion state of the screws observed during the tests. The results indicated that 19 screws (average rate per group was 12 %) failed to complete the test successfully, whereas only 20 screws (average rate per group was 17 %) required no pretapping to facilitate threadform insertion. Furthermore, factors such as smaller diameter, lower thread pitch angle, and usage in cancellous bone positively influenced (based on pretapping angle inputs) screw insertion under uniform testing conditions. In conclusion, ASTM F543-A2-23 demonstrates certain applicability for the completion of testing; however, it cannot guarantee optimal screw insertion performance for all screws. Reassessment for default axial force or further clarifying its role (to overcome self-tapping resistance and ensure proper insertion) would be beneficial for enhancing the standard’s applicability.
- 14 October 2025
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 54 (2) , 345-356
Applicability of ASTM F543-23-A2 Standards Across Diverse Bone Screw Types
ASTM F543-23-A2, Standard Specification and Test Methods for Metallic Medical Bone Screws, provides critical experiential data on the torque required by surgeons when securing screws in clinical settings. This study aimed to evaluate the universal applicability of ASTM standard default testing parameters in assessing a wide variety of screws. A total of 131 screws, spanning 24 types, were selected and tested following ASTM F543-23-A2 guidelines, with the insertion state of the screws observed during the tests. The results indicated that 19 screws (average rate per group was 12 %) failed to complete the test successfully, whereas only 20 screws (average rate per group was 17 %) required no pretapping to facilitate threadform insertion. Furthermore, factors such as smaller diameter, lower thread pitch angle, and usage in cancellous bone positively influenced (based on pretapping angle inputs) screw insertion under uniform testing conditions. In conclusion, ASTM F543-A2-23 demonstrates certain applicability for the completion of testing; however, it cannot guarantee optimal screw insertion performance for all screws. Reassessment for default axial force or further clarifying its role (to overcome self-tapping resistance and ensure proper insertion) would be beneficial for enhancing the standard’s applicability.
- Open Access
- 14 May 2025
- Published by MDPI AG in Lubricants
- Vol. 13 (5) , 217
Simulation Study on the Surface Texturing Design of COC Hip Joints Based on Elastohydrodynamic Lubrication Model
Post-operative feedback from hip replacement surgeries indicates that implanted ceramic artificial hip joints may produce abnormal noises during movement. This occurrence of joint noise is highly correlated with insufficient lubrication of ceramic-on-ceramic (COC) prostheses. Studies have shown that surface texture design can improve lubrication performance. In this study, the elastohydrodynamic lubrication model was established with designing textures on the surface of the COC hip joint, using Matlab R2018b and GNU FORTRAN in Codeblocks 20.03 programming. Iterative calculations were performed to determine the average bearing capacity of the oil film and the friction coefficient. The study explored the impact of texture parameters, including the aspect ratio and density, on the lubrication and friction performance of the hip joints. The results indicate that the textured surface generally has a higher fluid film bearing capacity by 161.5~637.7% and a lower friction coefficient by 10.7~60% than the smooth surface. The average bearing capacity of the fluid film increases with an increasing texture aspect ratio, while the trend of the friction coefficient is identical to the average bearing capacity results. As the texture density increases, the average bearing capacity of the fluid film first decreases and then increases, and the trend of the friction coefficient also increases accordingly. Among the nine design groups (), based on the fuzzy comprehensive evaluation, the local optimal solution is , for lubrication and wear resistance.- 14 May 2025
- Published by MDPI AG in Lubricants
- Vol. 13 (5) , 217
Open AccessSimulation Study on the Surface Texturing Design of COC Hip Joints Based on Elastohydrodynamic Lubrication Model
Post-operative feedback from hip replacement surgeries indicates that implanted ceramic artificial hip joints may produce abnormal noises during movement. This occurrence of joint noise is highly correlated with insufficient lubrication of ceramic-on-ceramic (COC) prostheses. Studies have shown that surface texture design can improve lubrication performance. In this study, the elastohydrodynamic lubrication model was established with designing textures on the surface of the COC hip joint, using Matlab R2018b and GNU FORTRAN in Codeblocks 20.03 programming. Iterative calculations were performed to determine the average bearing capacity of the oil film and the friction coefficient. The study explored the impact of texture parameters, including the aspect ratio and density, on the lubrication and friction performance of the hip joints. The results indicate that the textured surface generally has a higher fluid film bearing capacity by 161.5~637.7% and a lower friction coefficient by 10.7~60% than the smooth surface. The average bearing capacity of the fluid film increases with an increasing texture aspect ratio, while the trend of the friction coefficient is identical to the average bearing capacity results. As the texture density increases, the average bearing capacity of the fluid film first decreases and then increases, and the trend of the friction coefficient also increases accordingly. Among the nine design groups (), based on the fuzzy comprehensive evaluation, the local optimal solution is , for lubrication and wear resistance. - Open Access
- 19 December 2024
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 25 (1) , 1040
Characteristics and mechanical mechanisms of intervertebral disc degeneration in old thoracolumbar fractures with kyphosis: clinical observations and finite element analyses
Background Low back pain is a common complication in patients with old thoracolumbar fractures with kyphosis (OTLFK), and intervertebral disc degeneration (IDD) is a major contributor. Mechanical abnormalities are believed to play a key role in the development to IDD. This study aimed to investigate the characteristics of lumbar disc degeneration and underlying mechanical mechanisms in patients with OTLFK. Methods A total of 52 patients with OTLFK were included from February 2017 to March 2023 as the observation group (OG). A control group (CG) of individuals with chronic low back pain were matched for age, body mass index, and gender. The disc degeneration grades and distribution in both groups were observed. Intact, 20 degrees, 30 degrees, and 40 degrees kyphotic finite element (FE) models were established. Intervertebral disc pressures (IDPs) were calculated under standing, flexion, extension, lateral bending, and axial rotation conditions. Results The overall IDD in the OG was higher than that in the CG. The grades from T11 to L3 were higher in the OG (p < 0.05), while there was no significant difference from L4 to S1. Degeneration levels IV and V were concentrated in the T11-L3 segment in the OG; whereas, in the CG, this was in L4/5 and L5/S1 (p < 0.05). The FE analysis results showed that, in the kyphotic model, the IDP was higher than the intact model in the standing position, flexion, lateral bending, and rotation, but lower in extension. Conclusions Patients with OTLFK exhibit higher-grade disc degeneration concentrated in the thoracolumbar segment. Abnormal mechanical stress may contribute to this degeneration, highlighting the importance of managing stress in kyphotic deformities.
- 19 December 2024
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 25 (1) , 1040
Open AccessCharacteristics and mechanical mechanisms of intervertebral disc degeneration in old thoracolumbar fractures with kyphosis: clinical observations and finite element analyses
Background Low back pain is a common complication in patients with old thoracolumbar fractures with kyphosis (OTLFK), and intervertebral disc degeneration (IDD) is a major contributor. Mechanical abnormalities are believed to play a key role in the development to IDD. This study aimed to investigate the characteristics of lumbar disc degeneration and underlying mechanical mechanisms in patients with OTLFK. Methods A total of 52 patients with OTLFK were included from February 2017 to March 2023 as the observation group (OG). A control group (CG) of individuals with chronic low back pain were matched for age, body mass index, and gender. The disc degeneration grades and distribution in both groups were observed. Intact, 20 degrees, 30 degrees, and 40 degrees kyphotic finite element (FE) models were established. Intervertebral disc pressures (IDPs) were calculated under standing, flexion, extension, lateral bending, and axial rotation conditions. Results The overall IDD in the OG was higher than that in the CG. The grades from T11 to L3 were higher in the OG (p < 0.05), while there was no significant difference from L4 to S1. Degeneration levels IV and V were concentrated in the T11-L3 segment in the OG; whereas, in the CG, this was in L4/5 and L5/S1 (p < 0.05). The FE analysis results showed that, in the kyphotic model, the IDP was higher than the intact model in the standing position, flexion, lateral bending, and rotation, but lower in extension. Conclusions Patients with OTLFK exhibit higher-grade disc degeneration concentrated in the thoracolumbar segment. Abnormal mechanical stress may contribute to this degeneration, highlighting the importance of managing stress in kyphotic deformities.
- Open Access
- 29 November 2023
- Published by Wiley in Orthopaedic Surgery
- Vol. 16 (1) , 157-166
A Cadaveric Study of the Optimal Isometric Region on the Anterolateral Surface of the Knee in Anterolateral Ligament Reconstruction
Objective: Isolated intra‐articular anterior cruciate ligament (ACL) reconstruction is not capable of restoring instability in many cases leading some to recommend concomitant anterolateral ligament (ALL) reconstruction. The satisfactory fixation site and graft length change are crucial in ligament reconstruction to restore the ALL function and avoid some unwanted graft behavior. The purpose of this investigation is to determine the optimal isometric region on the anterolateral aspect of the knee for ALL reconstruction using a three‐dimensional optical instrument and a suture similar to an intraoperative isometric test.Methods: Six freshly frozen cadaveric human knees were used in this study. Data regarding the anterolateral surface were obtained using an optical measurement system to create a three‐dimensional model. Nine points were selected on the femur (F1‐F9) and tibia (Ta‐Ti) respectively. The three‐dimensional length change between each pair of tibial and femoral points was measured during passive knee flexion from 0° to 90° in 15° increments. Subsequently, five femoral points (A–E) were selected from the lateral femur, located in different areas relative to the lateral femoral epicondyle, and three tibial reference points (T1‐T3) were selected in the isometric test. The changes in the length between each pair of reference points were measured using sutures. The 95% confidence interval for the rate of length change was estimated using the mean and standard deviation of the maximum rate of length change at different flexion angles, and the data were expressed as the mean (95% confidence interval) and compared with the maximum acceptable rate of change (10%).Results: The maximum acceptable change rate for ligament reconstruction is 10%, and the mean maximum rates and the 95% confidence interval (CI) of length change for the point combinations were calculated. Among all the combined points measured using the optical measurement system and the suture, the qualified point combination for reconstruction was F3 (8mm posterior and 8mm proximal to the lateral femoral epicondyle)‐Tb (8mm proximal to the midpoint between the center of Gerdy's tubercle and the fibula head), A (posterior and proximal to the lateral femoral epicondyle)‐T2 (10mm below the joint line)and A‐T3 (15 mm below the joint line). The position of F3‐Tb and A‐T2 are close to each other.Conclusion: The most isometric area of the femur for ALL reconstruction was posterior and proximal to the lateral femoral epicondyle. We recommend that the initial location of the femoral point be set at 8 mm posterior and 8 mm proximal to the lateral femoral epicondyle and the tibial point at approximately 10 mm below the joint line, midway between Gerdy's tubercle and fibular head, and subsequently adjusted to the most satisfactory position according to the isometric test.
- 29 November 2023
- Published by Wiley in Orthopaedic Surgery
- Vol. 16 (1) , 157-166
Open AccessA Cadaveric Study of the Optimal Isometric Region on the Anterolateral Surface of the Knee in Anterolateral Ligament Reconstruction
Objective: Isolated intra‐articular anterior cruciate ligament (ACL) reconstruction is not capable of restoring instability in many cases leading some to recommend concomitant anterolateral ligament (ALL) reconstruction. The satisfactory fixation site and graft length change are crucial in ligament reconstruction to restore the ALL function and avoid some unwanted graft behavior. The purpose of this investigation is to determine the optimal isometric region on the anterolateral aspect of the knee for ALL reconstruction using a three‐dimensional optical instrument and a suture similar to an intraoperative isometric test.Methods: Six freshly frozen cadaveric human knees were used in this study. Data regarding the anterolateral surface were obtained using an optical measurement system to create a three‐dimensional model. Nine points were selected on the femur (F1‐F9) and tibia (Ta‐Ti) respectively. The three‐dimensional length change between each pair of tibial and femoral points was measured during passive knee flexion from 0° to 90° in 15° increments. Subsequently, five femoral points (A–E) were selected from the lateral femur, located in different areas relative to the lateral femoral epicondyle, and three tibial reference points (T1‐T3) were selected in the isometric test. The changes in the length between each pair of reference points were measured using sutures. The 95% confidence interval for the rate of length change was estimated using the mean and standard deviation of the maximum rate of length change at different flexion angles, and the data were expressed as the mean (95% confidence interval) and compared with the maximum acceptable rate of change (10%).Results: The maximum acceptable change rate for ligament reconstruction is 10%, and the mean maximum rates and the 95% confidence interval (CI) of length change for the point combinations were calculated. Among all the combined points measured using the optical measurement system and the suture, the qualified point combination for reconstruction was F3 (8mm posterior and 8mm proximal to the lateral femoral epicondyle)‐Tb (8mm proximal to the midpoint between the center of Gerdy's tubercle and the fibula head), A (posterior and proximal to the lateral femoral epicondyle)‐T2 (10mm below the joint line)and A‐T3 (15 mm below the joint line). The position of F3‐Tb and A‐T2 are close to each other.Conclusion: The most isometric area of the femur for ALL reconstruction was posterior and proximal to the lateral femoral epicondyle. We recommend that the initial location of the femoral point be set at 8 mm posterior and 8 mm proximal to the lateral femoral epicondyle and the tibial point at approximately 10 mm below the joint line, midway between Gerdy's tubercle and fibular head, and subsequently adjusted to the most satisfactory position according to the isometric test.
- Open Access
- 7 August 2023
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 11, 1229218
Finite element study of sagittal fracture location on thoracolumbar fracture treatment
Background: Posterior internal fixation is the main method used for the treatment of thoracolumbar fractures. Fractures often occur in the upper 1/3 of the vertebral body. However, they can also occur in the middle or lower 1/3 of the vertebral body. At present, there is no report discussing the potential effects of sagittal location on instrument biomechanics or surgical strategy. The object of this study was to investigate the effect of the sagittal location of the fracture region of the vertebral body on the biomechanics of the internal fixation system and surgical strategy.Methods: A finite element model of the T11-L3 thoracolumbar segment was established based on a healthy person’s CT scan. Different sagittal fracture location finite element models were created by resection of the upper 1/3, middle 1/3, and lower 1/3 of the L1 vertebral body. Three surgical strategies were utilized in this study, namely, proximal 1 level and distal 1 level (P1-D1), proximal 2 level and distal 1 level (P2-D1), and proximal 1 level and distal 2 levels (P1-D2). Nine fixation finite element models were created by combining fracture location and fixation strategies. Range of motion, von Mises stress, and stress distribution were analyzed to evaluate the effects on the instrument biomechanics and the selection of surgical strategy.Results: In all three different fixation strategies, the maximum von Mises stress location on the screw did not change with the sagittal location of the fracture site; nevertheless, the maximum von Mises stress differed. The maximum rod stress was located at the fracture site, with its value and location changed slightly. In the same fixation strategy, a limited effect of sagittal location on the range of motion was observed. P2D1 resulted in a shorter range of motion and lower screw stress for all sagittal locations of the fracture compared with the other strategies; however, rod stress was similar between strategies.Conclusion: The sagittal location of a fracture may affect the intensity and distribution of stress on the fixation system but does not influence the selection of surgical strategy.
- 7 August 2023
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 11, 1229218
Open AccessFinite element study of sagittal fracture location on thoracolumbar fracture treatment
Background: Posterior internal fixation is the main method used for the treatment of thoracolumbar fractures. Fractures often occur in the upper 1/3 of the vertebral body. However, they can also occur in the middle or lower 1/3 of the vertebral body. At present, there is no report discussing the potential effects of sagittal location on instrument biomechanics or surgical strategy. The object of this study was to investigate the effect of the sagittal location of the fracture region of the vertebral body on the biomechanics of the internal fixation system and surgical strategy.Methods: A finite element model of the T11-L3 thoracolumbar segment was established based on a healthy person’s CT scan. Different sagittal fracture location finite element models were created by resection of the upper 1/3, middle 1/3, and lower 1/3 of the L1 vertebral body. Three surgical strategies were utilized in this study, namely, proximal 1 level and distal 1 level (P1-D1), proximal 2 level and distal 1 level (P2-D1), and proximal 1 level and distal 2 levels (P1-D2). Nine fixation finite element models were created by combining fracture location and fixation strategies. Range of motion, von Mises stress, and stress distribution were analyzed to evaluate the effects on the instrument biomechanics and the selection of surgical strategy.Results: In all three different fixation strategies, the maximum von Mises stress location on the screw did not change with the sagittal location of the fracture site; nevertheless, the maximum von Mises stress differed. The maximum rod stress was located at the fracture site, with its value and location changed slightly. In the same fixation strategy, a limited effect of sagittal location on the range of motion was observed. P2D1 resulted in a shorter range of motion and lower screw stress for all sagittal locations of the fracture compared with the other strategies; however, rod stress was similar between strategies.Conclusion: The sagittal location of a fracture may affect the intensity and distribution of stress on the fixation system but does not influence the selection of surgical strategy.
- Open Access
Investigation of the Friction Properties of a New Artificial Imitation Cartilage Material: PHEMA/Glycerol Gel
The absence of artificial articular cartilage could cause the failure of artificial joints due to excessive material wear. There has been limited research on alternative materials for articular cartilage in joint prostheses, with few reducing the friction coefficient of artificial cartilage prostheses to the range of the natural cartilage friction coefficient (0.001–0.03). This work aimed to obtain and characterize mechanically and tribologically a new gel for potential application in articular replacement. Therefore, poly(hydroxyethyl methacrylate) (PHEMA)/glycerol synthetic gel was developed as a new type of artificial joint cartilage with a low friction coefficient, especially in calf serum. This glycerol material was developed via mixing HEMA and glycerin at a mass ratio of 1:1. The mechanical properties were studied, and it was found that the hardness of the synthetic gel was close to that of natural cartilage. The tribological performance of the synthetic gel was investigated using a reciprocating ball-on-plate rig. The ball samples were made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy, and the plates were synthetic glycerol gel and two additional materials for comparison, which were ultra-high molecular polyethylene (UHMWPE) and 316L stainless steel. It was found that synthetic gel exhibited the lowest friction coefficient in both calf serum (0.018) and deionized water (0.039) compared to the other two conventional materials for knee prostheses. The surface roughness of the gel was found to be 4–5 μm through morphological analysis of wear. This newly proposed material provided a possible solution as a type of cartilage composite coating with hardness and tribological performance close to the nature of use in wear couples with artificial joints.
Open AccessInvestigation of the Friction Properties of a New Artificial Imitation Cartilage Material: PHEMA/Glycerol Gel
The absence of artificial articular cartilage could cause the failure of artificial joints due to excessive material wear. There has been limited research on alternative materials for articular cartilage in joint prostheses, with few reducing the friction coefficient of artificial cartilage prostheses to the range of the natural cartilage friction coefficient (0.001–0.03). This work aimed to obtain and characterize mechanically and tribologically a new gel for potential application in articular replacement. Therefore, poly(hydroxyethyl methacrylate) (PHEMA)/glycerol synthetic gel was developed as a new type of artificial joint cartilage with a low friction coefficient, especially in calf serum. This glycerol material was developed via mixing HEMA and glycerin at a mass ratio of 1:1. The mechanical properties were studied, and it was found that the hardness of the synthetic gel was close to that of natural cartilage. The tribological performance of the synthetic gel was investigated using a reciprocating ball-on-plate rig. The ball samples were made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy, and the plates were synthetic glycerol gel and two additional materials for comparison, which were ultra-high molecular polyethylene (UHMWPE) and 316L stainless steel. It was found that synthetic gel exhibited the lowest friction coefficient in both calf serum (0.018) and deionized water (0.039) compared to the other two conventional materials for knee prostheses. The surface roughness of the gel was found to be 4–5 μm through morphological analysis of wear. This newly proposed material provided a possible solution as a type of cartilage composite coating with hardness and tribological performance close to the nature of use in wear couples with artificial joints.
- Open Access
- 23 May 2023
- Published by Springer Nature in Research Square
Does Sagittal Location of the Fracture Region of Vertebral Body Affect the Interfixation Instrument Biomechanics or Surgical Strategy in Thoracolumbar Fracture Treatment: a Finite Element Analysis
Background: Posterior internal fixation is the main method used for the treatment of thoracolumbar fractures. Fractures often occur in the upper 1/3 of the vertebral body. However, they can also occur in the middle or lower 1/3 of the vertebral body. At present, there is no report discussing the potential effects of sagittal location on instrument biomechanics or surgical strategy. The objects of this study was to investigate the effect of the sagittal location of the fracture region of the vertebral body on the biomechanics of the internal fixation system and surgical strategy. Methods: A finite element model of the T11-L3 thoracolumbar segment was established based on a healthy person’s CT scan. Different sagittal fracture location finite element models were created by resection of the upper 1/3, middle 1/3, and lower 1/3 of the L1 vertebral body. Three surgical strategies were utilized in this study, namely proximal 1 level and distal 1 level (P1-D1), proximal 2 level and distal 1 level(P2-D1), and proximal 1 level and distal 2 levels (P1-D2). Nine fixation finite element models were created by combining fracture location and fixation strategies. Range of motion, von Mises stress, and stress distribution were analyzed to evaluate the effects on the instrument biomechanics and the selection of surgical strategy. Results: In all three different fixation strategies, the maximum von Mises stress location on the screw did not change with the sagittal location of the fracture site; nevertheless, the maximum von Mises stress differed. The maximum rod stress was located at the fracture site, with its value and location changed slightly. In the same fixation strategy, a limited effect of sagittal location on the range of motion was observed. P2D1 resulted in a shorter range of motion and lower nail stress for all sagittal locations of the fracture compared with the other strategies; however, rod stress was similar between strategies. Conclusions: The sagittal location of a fracture may affect the stress and distribution, but does not influence the selection of surgical strategy.
- 23 May 2023
- Published by Springer Nature in Research Square
Open AccessDoes Sagittal Location of the Fracture Region of Vertebral Body Affect the Interfixation Instrument Biomechanics or Surgical Strategy in Thoracolumbar Fracture Treatment: a Finite Element Analysis
Background: Posterior internal fixation is the main method used for the treatment of thoracolumbar fractures. Fractures often occur in the upper 1/3 of the vertebral body. However, they can also occur in the middle or lower 1/3 of the vertebral body. At present, there is no report discussing the potential effects of sagittal location on instrument biomechanics or surgical strategy. The objects of this study was to investigate the effect of the sagittal location of the fracture region of the vertebral body on the biomechanics of the internal fixation system and surgical strategy. Methods: A finite element model of the T11-L3 thoracolumbar segment was established based on a healthy person’s CT scan. Different sagittal fracture location finite element models were created by resection of the upper 1/3, middle 1/3, and lower 1/3 of the L1 vertebral body. Three surgical strategies were utilized in this study, namely proximal 1 level and distal 1 level (P1-D1), proximal 2 level and distal 1 level(P2-D1), and proximal 1 level and distal 2 levels (P1-D2). Nine fixation finite element models were created by combining fracture location and fixation strategies. Range of motion, von Mises stress, and stress distribution were analyzed to evaluate the effects on the instrument biomechanics and the selection of surgical strategy. Results: In all three different fixation strategies, the maximum von Mises stress location on the screw did not change with the sagittal location of the fracture site; nevertheless, the maximum von Mises stress differed. The maximum rod stress was located at the fracture site, with its value and location changed slightly. In the same fixation strategy, a limited effect of sagittal location on the range of motion was observed. P2D1 resulted in a shorter range of motion and lower nail stress for all sagittal locations of the fracture compared with the other strategies; however, rod stress was similar between strategies. Conclusions: The sagittal location of a fracture may affect the stress and distribution, but does not influence the selection of surgical strategy.