Leiming Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Leiming Gao has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Zhongmin Jin
Orthotek Laboratory, School of Mechatronics Engineering and Automation, Shanghai University, Shanghai, China
7 shared publicationsPeiran Yang
5 shared publications- Zikai Hua
School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China
4 shared publications - Gregory de Boer
School of Mechanical Engineering, University of Leeds, Leeds, UK
3 shared publications - Qingen Meng
School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK
3 shared publications - Rob W. Hewson
Department of Aeronautics Imperial College London London UK
3 shared publications
Latest Publications
- Open Access
- 14 May 2025
- Published by MDPI AG in Lubricants
- Vol. 13 (5) , 217
Simulation Study on the Surface Texturing Design of COC Hip Joints Based on Elastohydrodynamic Lubrication Model
Post-operative feedback from hip replacement surgeries indicates that implanted ceramic artificial hip joints may produce abnormal noises during movement. This occurrence of joint noise is highly correlated with insufficient lubrication of ceramic-on-ceramic (COC) prostheses. Studies have shown that surface texture design can improve lubrication performance. In this study, the elastohydrodynamic lubrication model was established with designing textures on the surface of the COC hip joint, using Matlab R2018b and GNU FORTRAN in Codeblocks 20.03 programming. Iterative calculations were performed to determine the average bearing capacity of the oil film and the friction coefficient. The study explored the impact of texture parameters, including the aspect ratio and density, on the lubrication and friction performance of the hip joints. The results indicate that the textured surface generally has a higher fluid film bearing capacity by 161.5~637.7% and a lower friction coefficient by 10.7~60% than the smooth surface. The average bearing capacity of the fluid film increases with an increasing texture aspect ratio, while the trend of the friction coefficient is identical to the average bearing capacity results. As the texture density increases, the average bearing capacity of the fluid film first decreases and then increases, and the trend of the friction coefficient also increases accordingly. Among the nine design groups (), based on the fuzzy comprehensive evaluation, the local optimal solution is , for lubrication and wear resistance.- 14 May 2025
- Published by MDPI AG in Lubricants
- Vol. 13 (5) , 217
Open AccessSimulation Study on the Surface Texturing Design of COC Hip Joints Based on Elastohydrodynamic Lubrication Model
Post-operative feedback from hip replacement surgeries indicates that implanted ceramic artificial hip joints may produce abnormal noises during movement. This occurrence of joint noise is highly correlated with insufficient lubrication of ceramic-on-ceramic (COC) prostheses. Studies have shown that surface texture design can improve lubrication performance. In this study, the elastohydrodynamic lubrication model was established with designing textures on the surface of the COC hip joint, using Matlab R2018b and GNU FORTRAN in Codeblocks 20.03 programming. Iterative calculations were performed to determine the average bearing capacity of the oil film and the friction coefficient. The study explored the impact of texture parameters, including the aspect ratio and density, on the lubrication and friction performance of the hip joints. The results indicate that the textured surface generally has a higher fluid film bearing capacity by 161.5~637.7% and a lower friction coefficient by 10.7~60% than the smooth surface. The average bearing capacity of the fluid film increases with an increasing texture aspect ratio, while the trend of the friction coefficient is identical to the average bearing capacity results. As the texture density increases, the average bearing capacity of the fluid film first decreases and then increases, and the trend of the friction coefficient also increases accordingly. Among the nine design groups (), based on the fuzzy comprehensive evaluation, the local optimal solution is , for lubrication and wear resistance. - Open Access
- 26 March 2024
- Published by Elsevier in International Journal of Industrial Ergonomics
- Vol. 101
Effects of the abdominal belt on the reduction of spinal forces and muscle activities during extreme transits of high-speed craft
- 26 March 2024
- Published by Elsevier in International Journal of Industrial Ergonomics
- Vol. 101
Open AccessEffects of the abdominal belt on the reduction of spinal forces and muscle activities during extreme transits of high-speed craft
- Open Access
Investigation of the Friction Properties of a New Artificial Imitation Cartilage Material: PHEMA/Glycerol Gel
The absence of artificial articular cartilage could cause the failure of artificial joints due to excessive material wear. There has been limited research on alternative materials for articular cartilage in joint prostheses, with few reducing the friction coefficient of artificial cartilage prostheses to the range of the natural cartilage friction coefficient (0.001–0.03). This work aimed to obtain and characterize mechanically and tribologically a new gel for potential application in articular replacement. Therefore, poly(hydroxyethyl methacrylate) (PHEMA)/glycerol synthetic gel was developed as a new type of artificial joint cartilage with a low friction coefficient, especially in calf serum. This glycerol material was developed via mixing HEMA and glycerin at a mass ratio of 1:1. The mechanical properties were studied, and it was found that the hardness of the synthetic gel was close to that of natural cartilage. The tribological performance of the synthetic gel was investigated using a reciprocating ball-on-plate rig. The ball samples were made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy, and the plates were synthetic glycerol gel and two additional materials for comparison, which were ultra-high molecular polyethylene (UHMWPE) and 316L stainless steel. It was found that synthetic gel exhibited the lowest friction coefficient in both calf serum (0.018) and deionized water (0.039) compared to the other two conventional materials for knee prostheses. The surface roughness of the gel was found to be 4–5 μm through morphological analysis of wear. This newly proposed material provided a possible solution as a type of cartilage composite coating with hardness and tribological performance close to the nature of use in wear couples with artificial joints.
Open AccessInvestigation of the Friction Properties of a New Artificial Imitation Cartilage Material: PHEMA/Glycerol Gel
The absence of artificial articular cartilage could cause the failure of artificial joints due to excessive material wear. There has been limited research on alternative materials for articular cartilage in joint prostheses, with few reducing the friction coefficient of artificial cartilage prostheses to the range of the natural cartilage friction coefficient (0.001–0.03). This work aimed to obtain and characterize mechanically and tribologically a new gel for potential application in articular replacement. Therefore, poly(hydroxyethyl methacrylate) (PHEMA)/glycerol synthetic gel was developed as a new type of artificial joint cartilage with a low friction coefficient, especially in calf serum. This glycerol material was developed via mixing HEMA and glycerin at a mass ratio of 1:1. The mechanical properties were studied, and it was found that the hardness of the synthetic gel was close to that of natural cartilage. The tribological performance of the synthetic gel was investigated using a reciprocating ball-on-plate rig. The ball samples were made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy, and the plates were synthetic glycerol gel and two additional materials for comparison, which were ultra-high molecular polyethylene (UHMWPE) and 316L stainless steel. It was found that synthetic gel exhibited the lowest friction coefficient in both calf serum (0.018) and deionized water (0.039) compared to the other two conventional materials for knee prostheses. The surface roughness of the gel was found to be 4–5 μm through morphological analysis of wear. This newly proposed material provided a possible solution as a type of cartilage composite coating with hardness and tribological performance close to the nature of use in wear couples with artificial joints.
- Open Access
- 27 September 2022
- Published by MDPI AG in Lubricants
- Vol. 10 (10) , 238
Lubrication Modelling of Artificial Joint Replacements: Current Status and Future Challenges
This paper reviews the recent advancements in computational modelling of the lubrication of hip and knee joint replacements, especially those concerning Professor Duncan Dowson’s contribution. The review starts with the development of modelling the five key parameters that appeared in the pioneered Hamrock–Dowson formula. Then, the theory and approaches for the mixed lubrication in which the artificial hip and knee joint replacements operate are reviewed. We also discuss the current challenges in modelling the lubrication behaviour of joint replacements and how these challenges could be addressed in future studies. These challenges include the mixed lubrication theory, the numerical complexities due to complicated realistic geometry, material and rheology, and individual physiological diversities.
- 27 September 2022
- Published by MDPI AG in Lubricants
- Vol. 10 (10) , 238
Open AccessLubrication Modelling of Artificial Joint Replacements: Current Status and Future Challenges
This paper reviews the recent advancements in computational modelling of the lubrication of hip and knee joint replacements, especially those concerning Professor Duncan Dowson’s contribution. The review starts with the development of modelling the five key parameters that appeared in the pioneered Hamrock–Dowson formula. Then, the theory and approaches for the mixed lubrication in which the artificial hip and knee joint replacements operate are reviewed. We also discuss the current challenges in modelling the lubrication behaviour of joint replacements and how these challenges could be addressed in future studies. These challenges include the mixed lubrication theory, the numerical complexities due to complicated realistic geometry, material and rheology, and individual physiological diversities.
- 23 August 2022
- Published by The University of Iowa
- Vol. 7 (1)
Simulation of abdominal belt effects on IAP and spinal compressive force with musculoskeletal human model
- 23 August 2022
- Published by The University of Iowa
- Vol. 7 (1)
Simulation of abdominal belt effects on IAP and spinal compressive force with musculoskeletal human model
- Open Access
- 22 August 2021
- Published by Institution of Engineering and Technology (IET) in Biosurface and Biotribology
- Vol. 7 (4) , 206-218
Transient mixed lubrication model of the human knee implant
The human knee implant is computationally modelled in the mixed lubrication regime to investigate the tribological performance of the implant. This model includes the complex geometry of the implant components, unlike elliptical contact models that approximate this geometry. Film thickness and pressure results are presented for an ISO gait cycle to determine the lubrication regime present within the implant during its operation. It was found that it was possible for the lubrication regime to span between elastohydrodynamic, mixed and boundary lubrication depending on the operating conditions of the implant. It was observed that the tribological conditions present in one condyle were not necessarily representative of the other. Multiple points of contact were found within the same condyle, which cannot be computed by the elliptical contact solvers. This model can be used to balance forces in all directions, instead of only the normal loads, as often done in elliptical contact models. This work is an initial step towards understanding the role of the complex geometry in the tribological characteristics of the human knee implant when operating in physiological conditions.
- 22 August 2021
- Published by Institution of Engineering and Technology (IET) in Biosurface and Biotribology
- Vol. 7 (4) , 206-218
Open AccessTransient mixed lubrication model of the human knee implant
The human knee implant is computationally modelled in the mixed lubrication regime to investigate the tribological performance of the implant. This model includes the complex geometry of the implant components, unlike elliptical contact models that approximate this geometry. Film thickness and pressure results are presented for an ISO gait cycle to determine the lubrication regime present within the implant during its operation. It was found that it was possible for the lubrication regime to span between elastohydrodynamic, mixed and boundary lubrication depending on the operating conditions of the implant. It was observed that the tribological conditions present in one condyle were not necessarily representative of the other. Multiple points of contact were found within the same condyle, which cannot be computed by the elliptical contact solvers. This model can be used to balance forces in all directions, instead of only the normal loads, as often done in elliptical contact models. This work is an initial step towards understanding the role of the complex geometry in the tribological characteristics of the human knee implant when operating in physiological conditions.
- Open Access
- 5 April 2019
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 5
Wear Test Apparatus for Friction and Wear Evaluation Hip Prostheses
Wear is a key factor affecting the survivorship of artificial hip joints. Joint wear testers, as called “simulators,” are developed to simulate the motions and force of human joints. By using simulators, in vitro wear tests could be performed for artificial joints. This paper introduces a new hip joint simulator developed for the biotribological investigation of artificial hip joints. Friction force measuring module has been set up and assembled to monitor the friction force during the wear tests. Validation tests have been performed using two kinds of wear couples of 28 mm CoCrMo femoral heads, against conventional and X-linked ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. The hip joint simulator is a precise and reliable method, both for the wear evaluation and biotribological investigation of hip prostheses.
- 5 April 2019
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 5
Open AccessWear Test Apparatus for Friction and Wear Evaluation Hip Prostheses
Wear is a key factor affecting the survivorship of artificial hip joints. Joint wear testers, as called “simulators,” are developed to simulate the motions and force of human joints. By using simulators, in vitro wear tests could be performed for artificial joints. This paper introduces a new hip joint simulator developed for the biotribological investigation of artificial hip joints. Friction force measuring module has been set up and assembled to monitor the friction force during the wear tests. Validation tests have been performed using two kinds of wear couples of 28 mm CoCrMo femoral heads, against conventional and X-linked ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. The hip joint simulator is a precise and reliable method, both for the wear evaluation and biotribological investigation of hip prostheses.
- 1 February 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 90, 626-634
In vitro experimental and numerical study on biomechanics and stability of a novel adjustable hemipelvic prosthesis
- 1 February 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 90, 626-634
In vitro experimental and numerical study on biomechanics and stability of a novel adjustable hemipelvic prosthesis