IMIván Marín-Franch

Iván Marín-Franch

*This is an algorithmically generated author record based on publicly available information.

Iván Marín-Franch has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Visual Field Testing on the Envision Head-Mounted Perimeter with and without Gaming Elements

    by Emmanouil Tsamis, Iván Marín-Franch, William H. Swanson, Michael Chaglasian, Anne Rozwat, Brittney Brady, Donald C. Hood, Nicholas Neissa, Ridwan Shabsigh, Lama A. Al-Aswad


  • Open Access

    Targeted perimetry for mapping the shape of glaucomatous arcuate scotomata

    by Ivan Marín‐Franch, Brett J. King, William H. Swanson

    Purpose: Recent work has shown potential benefits for perimetry with dense spacing. To investigate the impact of normal inhomogeneity of perimetric sensitivity on perimetry with dense spacing, suprathreshold perimetry was used near the optic disc where shadows of blood vessels affect sensitivity in healthy eyes. Methods: Three groups of participants were tested: 58 healthy older controls, 29 healthy younger controls and 18 patients with glaucoma. A Compass perimeter was operated with the Open Perimetry Interface, using custom software with three components: the first found the centre of the blind spot and assessed the general height, the second performed ‘circle perimetry’ with suprathreshold testing at 75 locations on three circles around the disc (radius 6°, 8° and 10°) and the third conducted adaptive ‘high‐density perimetry’ to map scotomata. Suprathreshold contrasts were set to a chosen offset above mean normal contrast threshold, adjusted by the general height. Results: Circle perimetry at different offsets in controls found that an offset of 5 dB was needed to keep the false positive rate below 5%. Test–retest measurements in controls found limits of agreement for general height were ±2.5 dB, and that reproducible defects on circle perimetry were at locations consistent with shadows of blood vessels. Circle perimetry and high‐density perimetry with a small offset of 1 dB led to the appearance of artefactual arcuate defects in controls. Circle perimetry with an offset of 5 dB in 26 eyes of 18 patients with glaucoma found scotomata in 22 sectors of 16 eyes in 13 patients. High‐density perimetry was performed with a 5 dB offset for 15 sectors in 12 of these eyes and confirmed arcuate defects in all cases. Conclusions: Targeted perimetry identified arcuate perimetric defects but required an offset of 5 dB to have reasonable specificity. Suggestions are made for improving the performance of targeted perimetry.


  • Open Access

    Combined Probability Test for Sectoral Progression of the Circumpapillary Retinal Nerve Fiber Layer Thickness

    by Iván Marín-Franch, Paul H. Artes, Sampson L. Abu, Lyne Racette

    Optical coherence tomography has become a widely used tool to assess structural changes at the optic nerve head and the peripapillary retina. Often, global analyses are supplemented with sectoral analyses, but it is unclear how to control specificity as trend analyses are conducted on a larger number of sectors. We introduce a random permutation analysis for a combined probability test of progression in circumpapillary retinal nerve fiber layer (cpRNFL) thickness applied to different number of sectors. A series of seven cpRNFL scans were extracted for 428 eyes of 255 patients with glaucoma from the DIGS/ADAGES dataset. The combined probability test was run for 2k sectors, where k = 0, ⋯, 8 in addition to the maximum possible number of pixels, 768. Positive rates were derived for specificity ranging from 100% to 85%. At 95% specificity, the positive rate for 768 pixels was 41% [37%, 46%]. The positive rates for global thickness, and for 12 sectors, were statistically significantly smaller (28% and 35%, respectively). Positive rates remained at the observed maximum until the number of sectors fell below 128. The permutation of cpRNFL thickness profiles makes it possible to detect highly localized change in cpRNFL profiles from optical coherence tomography. Glaucoma-related changes in the optic nerve fiber layer are often localized rather than global. Permutation analysis provides a framework to detect such changes without sacrificing specificity.

  • Open Access

    Application of offset estimator of differential entropy and mutual information with multivariate data

    by Iván Marín-Franch, Martín Sanz-Sabater, David H. Foster

    Numerical estimators of differential entropy and mutual information can be slow to converge as sample size increases. The offset Kozachenko–Leonenko (KLo) method described here implements an offset version of the Kozachenko–Leonenko estimator that can markedly improve convergence. Its use is illustrated in applications to the comparison of trivariate data from successive scene color images and the comparison of univariate data from stereophonic music tracks. Publicly available code for KLo estimation of both differential entropy and mutual information is provided for R, Python, and MATLAB computing environments at https://github.com/imarinfr/klo.


  • Open Access

    The Open Perimetry Initiative: A framework for cross-platform development for the new generation of portable perimeters

    by Iván Marín-Franch, Andrew Turpin, Paul H. Artes, Luke X Chong, Allison M. McKendrick, Karam A. Alawa, Michael Wall

    The Open Perimetry Initiative was formed in 2010 with the aim of reducing barriers to clinical research with visual fields and perimetry. Our two principal tools are the Open Perimetry Interface (OPI) and the visualFields package with analytical tools. Both are fully open source. The OPI package contains a growing number of drivers for commercially available perimeters, head-mounted devices, and virtual reality headsets. The visualFields package contains tools for the analysis and visualization of visual field data, including methods to compute deviation values and probability maps. We introduce a new frontend, the opiApp, that provides tools for customization for visual field testing and can be used as a frontend to run the OPI. The app can be used on the Octopus 900 (Haag-Streit), the Compass (iCare), the AP 7000 (Kowa), and the IMO (CREWT) perimeters, with permission from the device manufacturers. The app can also be used on Android phones with virtual reality headsets via a new driver interface, the PhoneHMD, implemented on the OPI. The use of the tools provided by the OPI library is showcased with a custom static automated perimetry test for the full visual field (up to 50 degrees nasally and 80 degrees temporally) developed with the OPI driver for the Octopus 900 and using visualFields for statistical analysis. With more than 60 citations in clinical and translational science journals, this initiative has contributed significantly to expand research in perimetry. The continued support of researchers, clinicians, and industry are key in transforming perimetry research into an open science.


  • Open Access

    Exploring the Limits of High-Density Perimetry for Characterizing Mild Defects

    by Iván Marín-Franch, Harry J. Wyatt, William H. Swanson

    High-density perimetry has found that conventional static perimetry misses defects due to undersampling, yet high-density testing can require extensive time to conduct and can be limited by normal fixational eye movements. The current study explored the limits of high-density perimetry by testing for angioscotomas, which include narrow and shallow regions of reduced sensitivity under the shadows of blood vessels in healthy eyes. The right eye of four healthy adults was tested with a Digital Light Ophthalmoscope that gathered retinal images at 25 Hz during stimulus presentations. The retinal images were used to infer stimulus location on each trial. Contrast thresholds for a Goldmann size III stimulus (white stimulus of 0.43° of diameter) were measured at 247 locations of a 13×19 regular grid, with separation 0.5°, extending from 11° to 17° horizontally and from –3° to 6° vertically. An innovative method termed slice analysis was used to locate regions of reduced sensitivity. Simulations were conducted to evaluate potential adaptive algorithms. Maps of perimetric sensitivity identified diffuse regions of reduced sensitivity near the blood vessels, but these showed only moderate structure-function agreement that was only modestly better when effects of eye position were accounted for. Slice analysis improved the agreement between location of major blood vessels and reduced sensitivity. Simulations demonstrated that test duration could be reduced dramatically by focusing on location of defects rather than maps of sensitivity, while improving structure-function agreement. These alternatives to conventional perimetry could potentially detect narrow shallow defects without the extensive time demands of high-density perimetry.

  • Open Access

    Visual Field Progression in Glaucoma: Comparison Between PoPLR and ANSWERS

    by Iván Marín-Franch, Paul H. Artes, Andrew Turpin, Lyne Racette

    Purpose: It has been suggested that the detection of visual field progression can be improved by modeling statistical properties of the data such as the increasing retest variability and the spatial correlation among visual field locations. We compared a method that models those properties, Analysis with Non-Stationary Weibull Error Regression and Spatial Enhancement (ANSWERS), against a simpler one that does not, Permutation of Pointwise Linear Regression (PoPLR). Methods: Visual field series from three independent longitudinal studies in patients with glaucoma were used to compare the positive rate of PoPLR and ANSWERS. To estimate the false-positive rate, the same visual field series were randomly re-ordered in time. The first dataset consisted of series of 7 visual fields from 101 eyes, the second consisted of series of 9 visual fields from 150 eyes, and the third consisted of series of more than 9 visual fields (17.5 on average) from 139 eyes. Results: For a statistical significance of 0.05, the false-positive rates for ANSWERS were about 3 times greater than expected at 15%, 17%, and 16%, respectively, whereas for PoPLR they were 7%, 3%, and 6%. After equating the specificities at 0.05 for both models, positive rates for ANSWERS were 16%, 25%, and 38%, whereas for PoPLR they were 12%, 33%, and 49%, or about 5% greater on average (95% confidence interval = −1% to 11%). Conclusions: Despite being simpler and less computationally demanding, PoPLR was at least as sensitive to deterioration as ANSWERS once the specificities were equated. Translational Relevance: Close control of false-positive rates is key when visual fields of patients are analyzed for change in both clinical practice and clinical trials.


  • Open Access

    The Open Perimetry Initiative: a framework for cross-platform development for the new generation of portable perimeters

    by Iván Marín-Franch, Andrew Turpin, Paul H Artes, Luke X Chong, Allison M McKendrick, Karam A Alawa, Michael Wall

    The Open Perimetry Initiative is fully open source and consists of the Open Perimetry Interface (OPI) and an accompanying package (visualFields) with analytical tools. The OPI package contains an ever-growing number of drivers for commercially available perimeters, head-mounted devices, and virtual reality headsets. The visualFields package contains tools for the analysis and visualization of visual field data, including methods to compute deviation values and probability maps. The use of the OPI and visualFields is shown through a custom static automated perimetry test for the full visual field (up to 50° nasally and 80° temporally) developed with the OPI driver for the Octopus 900 and using visualFields for statistical analysis. Its potential for the development of cross-platform apps for driving and testing portable devices is demonstrated with an OPI driver for an Android-based headset. With more than 55 citations in clinical and translational science as listed in Scopus, this initiative has contributed significantly to expanding the knowledge base in perimetry and clinical vision research at large, and with clinical translation. The continued support of researchers, clinicians, industry, and public institutions are key in transforming perimetry research from closed to open science. The Open Perimetry Initiative provides framework to achieve this.

  • Open Access

    Objective changes in astigmatism during accommodation

    by Francisco Lara‐Lacárcel, Iván Marín‐Franch, Vicente Fernández‐Sánchez, Resurrección Riquelme‐Nicolás, Norberto López‐Gil

    Purpose: Previous studies have shown small but clinically significant changes in the power and axis of astigmatism when the eye accommodates. Monocular objective measurements of the eye during accommodation, when the object approaches the eye without convergence, also reveal small astigmatic changes. Moreover, it is known that the eye exhibits ocular cyclotorsion at different gaze angles. Since accommodation and convergence normally occur simultaneously, we studied the change in the magnitude and axis of astigmatism during accommodation for different convergence angles. Methods: The left eye of 15 subjects between 20 and 49 years old (mean 28.5 ± 9.7 years) having ≤1.5 D astigmatism was evaluated. Measurements were made using a Shack‐Hartmann aberrometer for an accommodation range of +0.50 D to −10 D in 0.50 D steps, and for four monocular convergence demands: 0°, 5°, 10° and 15°. Statistical analysis used power vectors to quantify the change in cylinder power and axis for each accommodation and convergence demand with age. Results: Jackson cross‐cylinder component J 45 did not change during accommodation for all vergences tested. However, J 0 changed by an average of −0.02 D per dioptre of accommodation (D/Dacc) for convergence demands of 0°, 5° and 10° and −0.03 D/Dacc for the 15° demand. This corresponds to an average cylinder power change of −0.05 D/Dacc for convergences of 0°, 5° and 10° and −0.08 D/Dacc for 15° of convergence. The cylinder axis always changed towards 90° (against‐the‐rule), and age did not play a significant role. Conclusions: Except for accommodation demands >4 D, we did not find a clinically significant change in astigmatism for convergence angles up to 15º. The small changes in cylinder power and axis may be due to shifts in the position of the crystalline lens during accommodation.