Norberto López-Gil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Norberto López-Gil has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Matt Jaskulski
School of Optometry Indiana University Bloomington Indiana USA
6 shared publications - Paula Bernal-Molina
Department of Soil and Water Conservation and Organic Waste Management, Centro de Edafología y Biología Aplicada del Segura, CSIC, Murcia, Spain
5 shared publications - Rosa María Salmerón-Campillo
Grupo de Ciencias de la Visión (CiViUM), Facultad de Óptica y Optometría, Universidad de Murcia, Murcia, Spain; Visionapp Solutions S.L., Murcia, Spain
5 shared publications - Antonio Jesus Del Águila-Carrasco
Johnson and Johnson Vision Van Swietenlaan 5, Groningen, The Netherlands
3 shared publications Francisco Lara
Vision Sciences Research Group (CiViUM) University of Murcia Murcia Spain
3 shared publications- Iván Marín-Franch
Computational Optometry, Atarfe, Spain
3 shared publications
Latest Publications
- Open Access
- 1 August 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (7) , 1662-1675
Accuracy and precision of a sphero‐cylindrical over‐refraction app for smartphones
Purpose: To evaluate the accuracy and precision of a web‐based smartphone app designed to measure sphero‐cylindrical over‐refraction. Methods: A total of 307 healthy young subjects (22.5 ± 3.4 years) underwent clinical subjective refraction. In addition to each subject's refractive correction, spherical and cylindrical errors from −1.50 to 0.00 D were randomly induced so that their sum did not exceed −2.50 D, thereby generating a clinical over‐refraction. Seven different IOS and Android‐based smartphones were used. A new app showing tripole rescaling stimuli in blue or red light was used. Each subject used one smartphone to measure their induced over‐refraction subjectively, obtaining an app over‐refraction finding. Differences between the app and clinical over‐refraction were analysed across 675 values. Results: The mean difference between the app and clinical over‐refraction in terms of power vector components ± limits of agreement was 0.17 ± 0.84 D for M ( p < 0.0001), 0.01 ± 0.42 D ( p = 0.28) for J 0 and −0.01 ± 0.32 D ( p = 0.33) for J 45 . The corresponding values for sphere and cylinder were 0.16 ± 0.80 D ( p < 0.0001) and 0.01 ± 0.85 D ( p = 0.40), respectively. The sphere and cylinder measurements obtained by the app differed from the expected values by no more than 0.50 D in 85% of cases. Conclusions: The accuracy and precision of the over‐refraction obtained by the app was slightly lower than standard clinical subjective refraction in terms of inter‐examiner repeatability and comparable to measurements obtained using objective methods. The app shows the potential to perform sphero‐cylindrical over‐refractions reliably.
- 1 August 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (7) , 1662-1675
Open AccessAccuracy and precision of a sphero‐cylindrical over‐refraction app for smartphones
Purpose: To evaluate the accuracy and precision of a web‐based smartphone app designed to measure sphero‐cylindrical over‐refraction. Methods: A total of 307 healthy young subjects (22.5 ± 3.4 years) underwent clinical subjective refraction. In addition to each subject's refractive correction, spherical and cylindrical errors from −1.50 to 0.00 D were randomly induced so that their sum did not exceed −2.50 D, thereby generating a clinical over‐refraction. Seven different IOS and Android‐based smartphones were used. A new app showing tripole rescaling stimuli in blue or red light was used. Each subject used one smartphone to measure their induced over‐refraction subjectively, obtaining an app over‐refraction finding. Differences between the app and clinical over‐refraction were analysed across 675 values. Results: The mean difference between the app and clinical over‐refraction in terms of power vector components ± limits of agreement was 0.17 ± 0.84 D for M ( p < 0.0001), 0.01 ± 0.42 D ( p = 0.28) for J 0 and −0.01 ± 0.32 D ( p = 0.33) for J 45 . The corresponding values for sphere and cylinder were 0.16 ± 0.80 D ( p < 0.0001) and 0.01 ± 0.85 D ( p = 0.40), respectively. The sphere and cylinder measurements obtained by the app differed from the expected values by no more than 0.50 D in 85% of cases. Conclusions: The accuracy and precision of the over‐refraction obtained by the app was slightly lower than standard clinical subjective refraction in terms of inter‐examiner repeatability and comparable to measurements obtained using objective methods. The app shows the potential to perform sphero‐cylindrical over‐refractions reliably.
- Open Access
Preliminary Evaluation of Spherical Over-Refraction Measurement Using a Smartphone
Background: Smartphones offer a promising tool for monitoring refractive error, especially in underserved areas where there is a shortage of eye-care professionals. We propose a novel method for measuring spherical over-refraction using smartphones. Methods: Specific levels of myopia using positive spherical trial lenses, ranging from 0.00 D to 1.50 D in 0.25 D increments, were induced in 30 young participants (22 ± 5 years). A comparison was conducted between the induced over-refraction and the measurements obtained using a non-commercial mobile application based on the face–device distance measurement using the front camera while the subject was performing a resolution task. Results: Calibrated mobile app over-refraction results showed that 89.5% of the estimates had an error ≤ 0.25 D, and no errors exceeding 0.50 D. Bland–Altman analysis revealed no significant bias between app and clinical over-refraction, with a mean difference of 0.00 D ± 0.44 D (p = 0.981), indicating high accuracy and precision of the method. Conclusions: The methodology used shows high accuracy and precision in the measurement of the spherical over-refraction with only the use of a smartphone, allowing self-monitorization of potential myopia progression.
Open AccessPreliminary Evaluation of Spherical Over-Refraction Measurement Using a Smartphone
Background: Smartphones offer a promising tool for monitoring refractive error, especially in underserved areas where there is a shortage of eye-care professionals. We propose a novel method for measuring spherical over-refraction using smartphones. Methods: Specific levels of myopia using positive spherical trial lenses, ranging from 0.00 D to 1.50 D in 0.25 D increments, were induced in 30 young participants (22 ± 5 years). A comparison was conducted between the induced over-refraction and the measurements obtained using a non-commercial mobile application based on the face–device distance measurement using the front camera while the subject was performing a resolution task. Results: Calibrated mobile app over-refraction results showed that 89.5% of the estimates had an error ≤ 0.25 D, and no errors exceeding 0.50 D. Bland–Altman analysis revealed no significant bias between app and clinical over-refraction, with a mean difference of 0.00 D ± 0.44 D (p = 0.981), indicating high accuracy and precision of the method. Conclusions: The methodology used shows high accuracy and precision in the measurement of the spherical over-refraction with only the use of a smartphone, allowing self-monitorization of potential myopia progression.
- Open Access
- 13 June 2025
- Published by Elsevier in Journal of Optometry
- Vol. 18 (3) , 100561
Preliminary evaluation of smartphone-based addition measurement in a presbyopic population
- 13 June 2025
- Published by Elsevier in Journal of Optometry
- Vol. 18 (3) , 100561
Open AccessPreliminary evaluation of smartphone-based addition measurement in a presbyopic population
- Open Access
- 1 February 2024
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 44 (2) , 334-346
Intracapsular accommodation mechanism in terms of lens curvature gradient
The intracapsular accommodation mechanism (IAM) may be understood as an increase in the lens equivalent refractive index as the eye accommodates. Our goal was to evaluate the existence of an IAM by analysing observed changes in the inner curvature gradient of the lens. To this end, we fitted a gradient index and curvature lens model to published experimental data on external and nucleus geometry changes during accommodation. For each case analysed, we computed the refractive power and equivalent index for each accommodative state using a ray transfer matrix. All data sets showed an increase in the effective refractive index, indicating a positive IAM, which was stronger for older lenses. These results suggest a strong dependence of the lens equivalent refractive index on the inner curvature gradient.
- 1 February 2024
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 44 (2) , 334-346
Open AccessIntracapsular accommodation mechanism in terms of lens curvature gradient
The intracapsular accommodation mechanism (IAM) may be understood as an increase in the lens equivalent refractive index as the eye accommodates. Our goal was to evaluate the existence of an IAM by analysing observed changes in the inner curvature gradient of the lens. To this end, we fitted a gradient index and curvature lens model to published experimental data on external and nucleus geometry changes during accommodation. For each case analysed, we computed the refractive power and equivalent index for each accommodative state using a ray transfer matrix. All data sets showed an increase in the effective refractive index, indicating a positive IAM, which was stronger for older lenses. These results suggest a strong dependence of the lens equivalent refractive index on the inner curvature gradient.
- Open Access
Assessment of the Human Retinal Neural Selectivity to Square Gratings’ Orientation with the Multifocal and Pattern Electroretinograms
The retinal response to particular orientations might start a signaling cascade of events that help to modulate eye growth and respond to myopia control treatments. The purpose of this study was to investigate the retinal electrical activity in response to grids of different spatial orientations. The multifocal (mfERG) and pattern (PERG) ERG responses of nine eyes (spherical equivalent of −0.45 ± 1.15 D; mean age of 32.9 ± 7.7 years) were recorded with four grids (1.2 cpd) oriented at 60°, 90°, 120° and 180° under pupils’ dilation. The mfERG was analyzed by retinal eccentricity, quadrants and meridians with the same orientation of the grids. The response density of mfERG, the amplitudes of PERG and the implicit times of each peak from both tests were analyzed. The grid’s orientation did not evoke different implicit times in both tests. All retinal meridians showed higher response density with grids of parallel orientation to the meridian and lower response density with perpendicularly oriented grids. These differences were statistically significant in the horizontal and 60° meridians (p < 0.050). PERG response did not change with the grids’ orientations. The mfERG was sensitive to detect changes in the outer retinal activity with variations in stimulus orientation. The paradigm of meridional analysis of mfERG results might be more sensitive to orientation changes than the traditional analysis by rings, quadrants or hemifields.
Open AccessAssessment of the Human Retinal Neural Selectivity to Square Gratings’ Orientation with the Multifocal and Pattern Electroretinograms
The retinal response to particular orientations might start a signaling cascade of events that help to modulate eye growth and respond to myopia control treatments. The purpose of this study was to investigate the retinal electrical activity in response to grids of different spatial orientations. The multifocal (mfERG) and pattern (PERG) ERG responses of nine eyes (spherical equivalent of −0.45 ± 1.15 D; mean age of 32.9 ± 7.7 years) were recorded with four grids (1.2 cpd) oriented at 60°, 90°, 120° and 180° under pupils’ dilation. The mfERG was analyzed by retinal eccentricity, quadrants and meridians with the same orientation of the grids. The response density of mfERG, the amplitudes of PERG and the implicit times of each peak from both tests were analyzed. The grid’s orientation did not evoke different implicit times in both tests. All retinal meridians showed higher response density with grids of parallel orientation to the meridian and lower response density with perpendicularly oriented grids. These differences were statistically significant in the horizontal and 60° meridians (p < 0.050). PERG response did not change with the grids’ orientations. The mfERG was sensitive to detect changes in the outer retinal activity with variations in stimulus orientation. The paradigm of meridional analysis of mfERG results might be more sensitive to orientation changes than the traditional analysis by rings, quadrants or hemifields.
- Top Cited PapersOpen Access
- 4 February 2023
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 43 (3) , 388-401
Optical characterisation of two novel myopia control spectacle lenses
Purpose: To quantify the amount of myopic defocus, contrast modulation and other optical characteristics of two novel spectacle lenses (MiYOSMART by Hoya and Stellest by Essilor) with the inclusion of lenslets in their designs were investigated computationally and experimentally. This paper examined the hypothesis that despite the non‐coaxial nature of the optics, image degradation will exist due to the fragmented nature of the base optic when imaging through the lens regions populated by lenslets. Methods: Optical power was evaluated by computing wavefront vergence and curvature from wavefront slope measured with the Optocraft aberrometer within 1.0 and 6.0 mm apertures across MiYOSMART hexagons and Stellest rings. Point‐spread functions (PSFs) were computed using physical (wave) optics and geometrical ray optics principles, and compared with experimental measurements using a 4f optical system. Simulated retinal images and modulation transfer functions (MTFs) were computed from PSF‐derived optical transfer functions (OTFs). Results: Mean lenslet power in MiYOSMART was +3.95 ± 0.10 D through the hexagons and +6.00 ± 0.15 D in Stellest in rings 1–5 and decreased by 0.42 D/ring reaching 3.50 D in the final one. Stellest lenslets included up to −0.015 microns of primary spherical aberration. PSFs and retinal images revealed simultaneous contributions of the base optic and lenslets. MTFs showed a decrease in contrast at low (1–10 c/deg) spatial frequencies (SFs) comparable to 0.25 D of defocus, and retention of diminished levels of contrast at higher SFs. Conclusions: Varying sagittal power and consistent curvature power across the lenslets is an identifying signature of the novel non‐coaxial lens design included in both spectacle lenses. Lenslet array structure itself plays a significant role in determining image characteristics. For both lenses, the blur created by the fragmented base optic contributes to the image quality. The reduced MTFs over a wide range of spatial frequencies result in lowered image contrast.
- 4 February 2023
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 43 (3) , 388-401
Top Cited PapersOpen AccessOptical characterisation of two novel myopia control spectacle lenses
Purpose: To quantify the amount of myopic defocus, contrast modulation and other optical characteristics of two novel spectacle lenses (MiYOSMART by Hoya and Stellest by Essilor) with the inclusion of lenslets in their designs were investigated computationally and experimentally. This paper examined the hypothesis that despite the non‐coaxial nature of the optics, image degradation will exist due to the fragmented nature of the base optic when imaging through the lens regions populated by lenslets. Methods: Optical power was evaluated by computing wavefront vergence and curvature from wavefront slope measured with the Optocraft aberrometer within 1.0 and 6.0 mm apertures across MiYOSMART hexagons and Stellest rings. Point‐spread functions (PSFs) were computed using physical (wave) optics and geometrical ray optics principles, and compared with experimental measurements using a 4f optical system. Simulated retinal images and modulation transfer functions (MTFs) were computed from PSF‐derived optical transfer functions (OTFs). Results: Mean lenslet power in MiYOSMART was +3.95 ± 0.10 D through the hexagons and +6.00 ± 0.15 D in Stellest in rings 1–5 and decreased by 0.42 D/ring reaching 3.50 D in the final one. Stellest lenslets included up to −0.015 microns of primary spherical aberration. PSFs and retinal images revealed simultaneous contributions of the base optic and lenslets. MTFs showed a decrease in contrast at low (1–10 c/deg) spatial frequencies (SFs) comparable to 0.25 D of defocus, and retention of diminished levels of contrast at higher SFs. Conclusions: Varying sagittal power and consistent curvature power across the lenslets is an identifying signature of the novel non‐coaxial lens design included in both spectacle lenses. Lenslet array structure itself plays a significant role in determining image characteristics. For both lenses, the blur created by the fragmented base optic contributes to the image quality. The reduced MTFs over a wide range of spatial frequencies result in lowered image contrast.
- Open Access
- 27 May 2022
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 42 (5) , 1074-1091
Catastrophe optics theory unveils the localised wave aberration features that generate ghost images
Monocular polyplopia (ghost or multiple images) is a serious visual impediment for some people who report seeing two (diplopia), three (triplopia) or even more images. Polyplopia is expected to appear if the point spread function (PSF) has multiple intensity cores (a dense concentration of a large portion of the radiant flux contained in the PSF) relatively separated from each other, each of which contributes to a distinct image. We present a theory that assigns these multiple PSF cores to specific features of aberrated wavefronts, thereby accounting optically for the perceptual phenomenon of monocular polyplopia. The theory provides two major conclusions. First, the most likely event giving rise to multiple PSF cores is the presence of hyperbolic, or less probably elliptical, umbilic caustics (using the terminology of catastrophe optics). Second, those umbilic caustics formed on the retinal surface are associated with certain points of the wave aberration function, called cusps of Gauss, where the gradient of a curvature function vanishes. However, not all cusps of Gauss generate those umbilic caustics. We also provide necessary conditions for those cusps of Gauss to be fertile . To show the potential of this theoretical framework for understanding the nature and origin of polyplopia, we provide specific examples of ocular wave aberration functions that induce diplopia and triplopia. The polyplopia effects in these examples are illustrated by depicting the multi‐core PSFs and the convolved retinal images for clinical letter charts, both through computer simulations and through experimental recording using an adaptive optics set‐up. The number and location of cores in the PSF is thus a potentially useful metric for the existence and severity of polyplopia in spatial vision. These examples also help explain why physiological pupil constriction might reduce the incidence of ghosting and multiple images of daily objects that affect vision with dilated pupils. This mechanistic explanation suggests a possible role for optical phase‐masking as a clinical treatment for polyplopia and ghosting.
- 27 May 2022
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 42 (5) , 1074-1091
Open AccessCatastrophe optics theory unveils the localised wave aberration features that generate ghost images
Monocular polyplopia (ghost or multiple images) is a serious visual impediment for some people who report seeing two (diplopia), three (triplopia) or even more images. Polyplopia is expected to appear if the point spread function (PSF) has multiple intensity cores (a dense concentration of a large portion of the radiant flux contained in the PSF) relatively separated from each other, each of which contributes to a distinct image. We present a theory that assigns these multiple PSF cores to specific features of aberrated wavefronts, thereby accounting optically for the perceptual phenomenon of monocular polyplopia. The theory provides two major conclusions. First, the most likely event giving rise to multiple PSF cores is the presence of hyperbolic, or less probably elliptical, umbilic caustics (using the terminology of catastrophe optics). Second, those umbilic caustics formed on the retinal surface are associated with certain points of the wave aberration function, called cusps of Gauss, where the gradient of a curvature function vanishes. However, not all cusps of Gauss generate those umbilic caustics. We also provide necessary conditions for those cusps of Gauss to be fertile . To show the potential of this theoretical framework for understanding the nature and origin of polyplopia, we provide specific examples of ocular wave aberration functions that induce diplopia and triplopia. The polyplopia effects in these examples are illustrated by depicting the multi‐core PSFs and the convolved retinal images for clinical letter charts, both through computer simulations and through experimental recording using an adaptive optics set‐up. The number and location of cores in the PSF is thus a potentially useful metric for the existence and severity of polyplopia in spatial vision. These examples also help explain why physiological pupil constriction might reduce the incidence of ghosting and multiple images of daily objects that affect vision with dilated pupils. This mechanistic explanation suggests a possible role for optical phase‐masking as a clinical treatment for polyplopia and ghosting.
- Open Access
Gullstrand Intracapsular Accommodation Mechanism Revised
More than a century has passed since Allvar Gullstrand proposed his so called “mechanism of intracapsular accommodation” based on the concept that the change in lens power during accommodation can be larger if the lens is modeled by two different refractive indexes (cortex and nucleus) than if it is homogenous. Intracapsular accommodation of the original eye model proposed by Gullstrand is compared with that of a six-surfaces model eye built based on actual experimental data obtained with precise imaging techniques of the lens change during accommodation. The results show that nearly half (42%) of the accommodation of the Gullstrand model eye is produced by said mechanism, while a model eye based on actual data produces a small intracapsular dis-accommodation. The main reason for the discrepancy is the larger change in the radii of curvature of the lens nucleus during accommodation proposed by Gullstrand, which is necessary because his model likely did not take into account the reduction in the change in lens power produced by depth-of-focus.
Open AccessGullstrand Intracapsular Accommodation Mechanism Revised
More than a century has passed since Allvar Gullstrand proposed his so called “mechanism of intracapsular accommodation” based on the concept that the change in lens power during accommodation can be larger if the lens is modeled by two different refractive indexes (cortex and nucleus) than if it is homogenous. Intracapsular accommodation of the original eye model proposed by Gullstrand is compared with that of a six-surfaces model eye built based on actual experimental data obtained with precise imaging techniques of the lens change during accommodation. The results show that nearly half (42%) of the accommodation of the Gullstrand model eye is produced by said mechanism, while a model eye based on actual data produces a small intracapsular dis-accommodation. The main reason for the discrepancy is the larger change in the radii of curvature of the lens nucleus during accommodation proposed by Gullstrand, which is necessary because his model likely did not take into account the reduction in the change in lens power produced by depth-of-focus.
- Open Access
- 19 August 2021
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 41 (5) , 1069-1075
Objective changes in astigmatism during accommodation
Purpose: Previous studies have shown small but clinically significant changes in the power and axis of astigmatism when the eye accommodates. Monocular objective measurements of the eye during accommodation, when the object approaches the eye without convergence, also reveal small astigmatic changes. Moreover, it is known that the eye exhibits ocular cyclotorsion at different gaze angles. Since accommodation and convergence normally occur simultaneously, we studied the change in the magnitude and axis of astigmatism during accommodation for different convergence angles. Methods: The left eye of 15 subjects between 20 and 49 years old (mean 28.5 ± 9.7 years) having ≤1.5 D astigmatism was evaluated. Measurements were made using a Shack‐Hartmann aberrometer for an accommodation range of +0.50 D to −10 D in 0.50 D steps, and for four monocular convergence demands: 0°, 5°, 10° and 15°. Statistical analysis used power vectors to quantify the change in cylinder power and axis for each accommodation and convergence demand with age. Results: Jackson cross‐cylinder component J 45 did not change during accommodation for all vergences tested. However, J 0 changed by an average of −0.02 D per dioptre of accommodation (D/Dacc) for convergence demands of 0°, 5° and 10° and −0.03 D/Dacc for the 15° demand. This corresponds to an average cylinder power change of −0.05 D/Dacc for convergences of 0°, 5° and 10° and −0.08 D/Dacc for 15° of convergence. The cylinder axis always changed towards 90° (against‐the‐rule), and age did not play a significant role. Conclusions: Except for accommodation demands >4 D, we did not find a clinically significant change in astigmatism for convergence angles up to 15º. The small changes in cylinder power and axis may be due to shifts in the position of the crystalline lens during accommodation.
- 19 August 2021
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 41 (5) , 1069-1075
Open AccessObjective changes in astigmatism during accommodation
Purpose: Previous studies have shown small but clinically significant changes in the power and axis of astigmatism when the eye accommodates. Monocular objective measurements of the eye during accommodation, when the object approaches the eye without convergence, also reveal small astigmatic changes. Moreover, it is known that the eye exhibits ocular cyclotorsion at different gaze angles. Since accommodation and convergence normally occur simultaneously, we studied the change in the magnitude and axis of astigmatism during accommodation for different convergence angles. Methods: The left eye of 15 subjects between 20 and 49 years old (mean 28.5 ± 9.7 years) having ≤1.5 D astigmatism was evaluated. Measurements were made using a Shack‐Hartmann aberrometer for an accommodation range of +0.50 D to −10 D in 0.50 D steps, and for four monocular convergence demands: 0°, 5°, 10° and 15°. Statistical analysis used power vectors to quantify the change in cylinder power and axis for each accommodation and convergence demand with age. Results: Jackson cross‐cylinder component J 45 did not change during accommodation for all vergences tested. However, J 0 changed by an average of −0.02 D per dioptre of accommodation (D/Dacc) for convergence demands of 0°, 5° and 10° and −0.03 D/Dacc for the 15° demand. This corresponds to an average cylinder power change of −0.05 D/Dacc for convergences of 0°, 5° and 10° and −0.08 D/Dacc for 15° of convergence. The cylinder axis always changed towards 90° (against‐the‐rule), and age did not play a significant role. Conclusions: Except for accommodation demands >4 D, we did not find a clinically significant change in astigmatism for convergence angles up to 15º. The small changes in cylinder power and axis may be due to shifts in the position of the crystalline lens during accommodation.
- Open Access
- 18 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (16) , 7566
Measuring Facial Illuminance with Smartphones and Mobile Devices
Introduction: To uncover a relationship between light exposure and myopia is complicated because of the challenging nature of measuring visually relevant illumination experienced by children. Objective: To find a methodology to measure face illuminance using a mobile device. Methods: Accuracy and precision of the mobile device’s built-in ambient light sensor were tested under three different lighting conditions: full-field, a single small light, and one mimicking typical office illumination. Face illuminance was computed in six faces with different skin reflectances using pixel values in face images captured by the device camera placed at 30 cm in front of the face. The results were compared with those obtained with a commercial light meter situated at the face. Results: The illuminance measured by the device’s ambient light sensor showed high linearity (R2 > 0.99) slightly under-estimating or conversely over-estimating face illuminance with full-field or single light sources but accurate for office lighting. Face illuminance measured by the devices’ camera under indoor conditions using the new methodology showed a mean relative error of 27% and a high linearity (R2 > 0.94). Conclusions: Introduction of an app can be used to assess the association between visually relevant environmental light levels and myopia progression.
- 18 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (16) , 7566
Open AccessMeasuring Facial Illuminance with Smartphones and Mobile Devices
Introduction: To uncover a relationship between light exposure and myopia is complicated because of the challenging nature of measuring visually relevant illumination experienced by children. Objective: To find a methodology to measure face illuminance using a mobile device. Methods: Accuracy and precision of the mobile device’s built-in ambient light sensor were tested under three different lighting conditions: full-field, a single small light, and one mimicking typical office illumination. Face illuminance was computed in six faces with different skin reflectances using pixel values in face images captured by the device camera placed at 30 cm in front of the face. The results were compared with those obtained with a commercial light meter situated at the face. Results: The illuminance measured by the device’s ambient light sensor showed high linearity (R2 > 0.99) slightly under-estimating or conversely over-estimating face illuminance with full-field or single light sources but accurate for office lighting. Face illuminance measured by the devices’ camera under indoor conditions using the new methodology showed a mean relative error of 27% and a high linearity (R2 > 0.94). Conclusions: Introduction of an app can be used to assess the association between visually relevant environmental light levels and myopia progression.