Xiangnan Wang
Xiangnan Wang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Jingkun Yu
School of Metallurgy, Northeastern University, Shenyang, Liaoning, 110819, China
8 shared publicationsLin Li
5 shared publicationsTao Liu
5 shared publicationsMaoyi Yi
Northeastern University
3 shared publications- Tao Liu
College of Urban and Environmental Sciences, Peking University, Beijing, China
3 shared publications Xiaofang Zhang
3 shared publications
Latest Publications
- Open Access
- 5 October 2023
- Published by IOS Press
- p. 130-139
Analysis of Power Fluctuation Characteristics of Tidal Current Energy Generation and Selection of Sampling Interval
With the continuous maturity of tidal current power generation technology, the scientific requirements for testing and evaluation are also increasing. In the process of analyzing the measured power data of tidal current power generation, the selection of sampling interval has a significant impact on the accuracy of power fluctuation analysis. Choosing an appropriate sampling interval can reduce data processing and improve calculation speed while ensuring the accuracy of test data. Based on the measured power data of tidal current power generation in a certain sea area of China during rising and falling tides, this paper calculated and analyzed the power fluctuation of multiple sampling intervals through discrete index analysis and first-order difference component analysis. And based on the entropy weight method, obtained the regularity of power fluctuation with sampling interval, calculated the comprehensive fluctuation coefficient to determine the maximum sampling interval, and proposed a recommended sampling interval of 60 seconds. This has important practical significance for scientifically testing tidal current power generation.
- 5 October 2023
- Published by IOS Press
- p. 130-139
Open AccessAnalysis of Power Fluctuation Characteristics of Tidal Current Energy Generation and Selection of Sampling Interval
With the continuous maturity of tidal current power generation technology, the scientific requirements for testing and evaluation are also increasing. In the process of analyzing the measured power data of tidal current power generation, the selection of sampling interval has a significant impact on the accuracy of power fluctuation analysis. Choosing an appropriate sampling interval can reduce data processing and improve calculation speed while ensuring the accuracy of test data. Based on the measured power data of tidal current power generation in a certain sea area of China during rising and falling tides, this paper calculated and analyzed the power fluctuation of multiple sampling intervals through discrete index analysis and first-order difference component analysis. And based on the entropy weight method, obtained the regularity of power fluctuation with sampling interval, calculated the comprehensive fluctuation coefficient to determine the maximum sampling interval, and proposed a recommended sampling interval of 60 seconds. This has important practical significance for scientifically testing tidal current power generation.
- Open Access
- 5 October 2023
- Published by IOS Press
- p. 40-49
Analysis on the Difference of Tidal Current Measurement in the Field Testing of Tidal Energy Converters
In the field test of tidal energy converters, the measurement of tidal current velocity is one of the key steps to evaluate the power characteristics performance of tidal energy converter. According to the requirements of tidal current velocity measurement specified by the International Electrotechnical Commission, tidal current velocity field measurement work was carried out, and the tidal current field measurement data was processed and analyzed by using the method proposed in this paper, which combines the elaborated division of tidal current velocity bine with standard deviation and correlation coefficient. The results show that: During the flood tide period, there is little difference in the mean value of tidal current velocity between the two measuring locations, but the tidal current velocity measured at the RTI location fluctuates greatly; During the ebb tide period, the mean value of tidal current velocity at the two measuring locations is quite different, and the tidal current velocity that measured at the RTI location also fluctuates greatly; The duration of the flood tide is shorter than that of the ebb tide, but the maximum value of tidal current velocity of the flood tide is greater than that of the ebb tide.
- 5 October 2023
- Published by IOS Press
- p. 40-49
Open AccessAnalysis on the Difference of Tidal Current Measurement in the Field Testing of Tidal Energy Converters
In the field test of tidal energy converters, the measurement of tidal current velocity is one of the key steps to evaluate the power characteristics performance of tidal energy converter. According to the requirements of tidal current velocity measurement specified by the International Electrotechnical Commission, tidal current velocity field measurement work was carried out, and the tidal current field measurement data was processed and analyzed by using the method proposed in this paper, which combines the elaborated division of tidal current velocity bine with standard deviation and correlation coefficient. The results show that: During the flood tide period, there is little difference in the mean value of tidal current velocity between the two measuring locations, but the tidal current velocity measured at the RTI location fluctuates greatly; During the ebb tide period, the mean value of tidal current velocity at the two measuring locations is quite different, and the tidal current velocity that measured at the RTI location also fluctuates greatly; The duration of the flood tide is shorter than that of the ebb tide, but the maximum value of tidal current velocity of the flood tide is greater than that of the ebb tide.
- 20 October 2021
- Published by Wiley in Chemnanomat
- Vol. 8 (1)
Micro/Nano‐Scaled Covalent Organic Frameworks: Polymerization, Crystallization and Self‐Assembly
In the past decade, considerable efforts have been extended on covalent organic frameworks (COFs), however, the basic research about the nucleation and crystal growth of COF materials has been greatly ignored. This review aims at providing an overview over the theoretical foundation and experimental observation of the multi‐scale structural engineering of COF materials, which includes complex polymerization, crystallization and self‐assembly processes. In this perspective, we first highlighted the latest advances on basic knowledge about the nucleation and growth of COFs, including classical and non‐classical crystallization mechanism as well as the synthesis of COF single crystals. Subsequently, we surveyed the effects of synthesis conditions, such as catalysts, monomer adding modes, heating methods, modulator and supramolecular interaction on the formation of COF materials. In the last, the research on the synthesis of COF nanoparticles, nanofibers and nanosheets based on the knowledge of crystal growth are reviewed in detail. The understanding related to the polymerization, crystallization and self‐assembly process during COF formation will surely make it easier to realize COFs with designed hierarchical architectures for targeted applications.
- 20 October 2021
- Published by Wiley in Chemnanomat
- Vol. 8 (1)
Micro/Nano‐Scaled Covalent Organic Frameworks: Polymerization, Crystallization and Self‐Assembly
In the past decade, considerable efforts have been extended on covalent organic frameworks (COFs), however, the basic research about the nucleation and crystal growth of COF materials has been greatly ignored. This review aims at providing an overview over the theoretical foundation and experimental observation of the multi‐scale structural engineering of COF materials, which includes complex polymerization, crystallization and self‐assembly processes. In this perspective, we first highlighted the latest advances on basic knowledge about the nucleation and growth of COFs, including classical and non‐classical crystallization mechanism as well as the synthesis of COF single crystals. Subsequently, we surveyed the effects of synthesis conditions, such as catalysts, monomer adding modes, heating methods, modulator and supramolecular interaction on the formation of COF materials. In the last, the research on the synthesis of COF nanoparticles, nanofibers and nanosheets based on the knowledge of crystal growth are reviewed in detail. The understanding related to the polymerization, crystallization and self‐assembly process during COF formation will surely make it easier to realize COFs with designed hierarchical architectures for targeted applications.
- 1 May 2019
- Published by Marine Technology Society in Marine Technology Society Journal
- Vol. 53 (3) , 46-53
Comprehensive Evaluation on Power Quality of Tidal Current Convertors
With the continuous development of testing and evaluation of tidal current convertors, power quality assessment is becoming more and more critical. According to the characteristics of Chinese tidal current power generation and power quality standards, this paper proposes a comprehensive evaluation method of power quality based on K-means clustering and a support vector machine. The fundamental purpose of the method is to automatically select the weights of various indicators in the comprehensive assessment of power quality, by which the influence of subjective factors can be eliminated. In order to achieve the above purpose, K-means clustering is used for automatically classifying the operational data into five different categories. Then, a support vector machine is used to study and estimate the relationship of the operational data and categories. Using the method proposed in the paper, the analysis of operational data of a tidal current power generation shows that calculation results can objectively reflect the power quality of the device, and the influence of subjective factors is eliminated. The method can provide a reference for the testing and evaluation of a large amount of tidal current convertors in the future.
- 1 May 2019
- Published by Marine Technology Society in Marine Technology Society Journal
- Vol. 53 (3) , 46-53
Comprehensive Evaluation on Power Quality of Tidal Current Convertors
With the continuous development of testing and evaluation of tidal current convertors, power quality assessment is becoming more and more critical. According to the characteristics of Chinese tidal current power generation and power quality standards, this paper proposes a comprehensive evaluation method of power quality based on K-means clustering and a support vector machine. The fundamental purpose of the method is to automatically select the weights of various indicators in the comprehensive assessment of power quality, by which the influence of subjective factors can be eliminated. In order to achieve the above purpose, K-means clustering is used for automatically classifying the operational data into five different categories. Then, a support vector machine is used to study and estimate the relationship of the operational data and categories. Using the method proposed in the paper, the analysis of operational data of a tidal current power generation shows that calculation results can objectively reflect the power quality of the device, and the influence of subjective factors is eliminated. The method can provide a reference for the testing and evaluation of a large amount of tidal current convertors in the future.
- Open Access
- 5 April 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 5745
An application of (4YSZ)0.93(Fe2O3)0.07 in limiting current oxygen sensor
(4YSZ)0.93(Fe2O3)0.07 and 9 mol% Y2O3 stabilized ZrO2 (9YSZ) were synthesized by co-precipitation method and their crystalline structure, microstructure, electronic conductivity, total conductivity were characterized. A limiting current oxygen sensor was assembled with (4YSZ)0.93(Fe2O3)0.07 dense diffusion barrier and 9YSZ solid electrolyte by Pt sintered-paste method. Influences of temperature (T), oxygen concentration (x(O2)) and water vapor pressure (p(H2O)) on sensing characteristics of the limiting current oxygen sensor were investigated. The crystalline structure of (4YSZ)0.93(Fe2O3)0.07 and 9YSZ belong to cubic structure with $${\bf{Fm}}\overline{{\bf{3}}}{\bf{m}}$$ . The total conductivity of (4YSZ)0.93(Fe2O3)0.07 is higher than that of 9YSZ and the electronic and total conductivities of the samples meet the linear relationship with 1000/T. The limiting current oxygen sensor exhibits excellent sensing characteristics under test conditions. The effects of T, x(O2) and p(H2O) are as follows: Log(IL·T) depends linearly on 1000/T, IL depends linearly on x(O2) and IL is not significantly dependent on p(H2O).- 5 April 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 5745
Open AccessAn application of (4YSZ)0.93(Fe2O3)0.07 in limiting current oxygen sensor
(4YSZ)0.93(Fe2O3)0.07 and 9 mol% Y2O3 stabilized ZrO2 (9YSZ) were synthesized by co-precipitation method and their crystalline structure, microstructure, electronic conductivity, total conductivity were characterized. A limiting current oxygen sensor was assembled with (4YSZ)0.93(Fe2O3)0.07 dense diffusion barrier and 9YSZ solid electrolyte by Pt sintered-paste method. Influences of temperature (T), oxygen concentration (x(O2)) and water vapor pressure (p(H2O)) on sensing characteristics of the limiting current oxygen sensor were investigated. The crystalline structure of (4YSZ)0.93(Fe2O3)0.07 and 9YSZ belong to cubic structure with $${\bf{Fm}}\overline{{\bf{3}}}{\bf{m}}$$ . The total conductivity of (4YSZ)0.93(Fe2O3)0.07 is higher than that of 9YSZ and the electronic and total conductivities of the samples meet the linear relationship with 1000/T. The limiting current oxygen sensor exhibits excellent sensing characteristics under test conditions. The effects of T, x(O2) and p(H2O) are as follows: Log(IL·T) depends linearly on 1000/T, IL depends linearly on x(O2) and IL is not significantly dependent on p(H2O). - 1 April 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 285, 391-397
A new application of Ce Zr1-O2 as dense diffusion barrier in limiting current oxygen sensor
- 1 April 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 285, 391-397
A new application of Ce Zr1-O2 as dense diffusion barrier in limiting current oxygen sensor
- Open Access
- 25 February 2019
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 23 (4) , 1249-1256
High Li-ion conductivity of Al-free Li7-3xGaxLa3Zr2O12 solid electrolyte prepared by liquid-phase sintering
- 25 February 2019
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 23 (4) , 1249-1256
Open AccessHigh Li-ion conductivity of Al-free Li7-3xGaxLa3Zr2O12 solid electrolyte prepared by liquid-phase sintering
- 1 December 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 277, 216-223
A limiting current oxygen sensor prepared by a co-pressing and co-sintering technique
- 1 December 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 277, 216-223
A limiting current oxygen sensor prepared by a co-pressing and co-sintering technique
- 1 November 2018
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 768, 838-846
The effect of Fe doping on the electrical conductivities of CaZrO3 and its sensing performance in limiting current oxygen sensor
- 1 November 2018
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 768, 838-846
The effect of Fe doping on the electrical conductivities of CaZrO3 and its sensing performance in limiting current oxygen sensor
- 1 October 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 270, 518-524
A novel limiting current oxygen sensor prepared by slurry spin coating
- 1 October 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 270, 518-524
A novel limiting current oxygen sensor prepared by slurry spin coating