Deepika Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Deepika Sharma has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Andras Jakab
Center for MR Research, University Children’s Hospital Zurich
2 shared publications Esra Neufeld
IT'IS Foundation for Research on Information Technologies in Society, Zurich, Switzerland
2 shared publicationsEsther Akinnagbe
Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, 20993, United States of America
2 shared publications- Ethan David Cohen
Department of Anatomy, University of Pennsylvania, Philadelphia 19104
2 shared publications Johanna Wolf
IT'IS Foundation for Research on Information Technologies in Society, Zurich, Switzerland; Swiss Federal Institute of Technology (ETH) Zurich, 8092 Zurich, Switzerland
2 shared publications- Leonardo M. Angelone
U.S. FDA, CDRH, Office of Science and Engineering Laboratories, Division of Biomedical Physics, Silver Spring, MD 20993 USA
2 shared publications
Latest Publications
- Open Access
- 12 June 2021
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 7 (1) , 1-12
Surface-modified elastomeric nanofluidic devices for single nanoparticle trapping
Our work focuses on the development of simpler and effective production of nanofluidic devices for high-throughput charged single nanoparticle trapping in an aqueous environment. Single nanoparticle confinement using electrostatic trapping has been an effective approach to study the fundamental properties of charged molecules under a controlled aqueous environment. Conventionally, geometry-induced electrostatic trapping devices are fabricated using SiOx-based substrates and comprise nanochannels imbedded with nanoindentations such as nanopockets, nanoslits and nanogrids. These geometry-induced electrostatic trapping devices can only trap negatively charged particles, and therefore, to trap positively charged particles, modification of the device surface is required. However, the surface modification process of a nanofluidic device is cumbersome and time consuming. Therefore, here, we present a novel approach for the development of surface-modified geometry-induced electrostatic trapping devices that reduces the surface modification time from nearly 5 days to just a few hours. We utilized polydimethylsiloxane for the development of a surface-modified geometry-induced electrostatic trapping device. To demonstrate the device efficiency and success of the surface modification procedure, a comparison study between a PDMS-based geometry-induced electrostatic trapping device and the surface-modified polydimethylsiloxane-based device was performed. The device surface was modified with two layers of polyelectrolytes (1: poly(ethyleneimine) and 2: poly(styrenesulfonate)), which led to an overall negatively charged surface. Our experiments revealed the presence of a homogeneous surface charge density inside the fluidic devices and equivalent trapping strengths for the surface-modified and native polydimethylsiloxane-based geometry-induced electrostatic trapping devices. This work paves the way towards broader use of geometry-induced electrostatic trapping devices in the fields of biosensing, disease diagnosis, molecular analysis, fluid quality control and pathogen detection.
- 12 June 2021
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 7 (1) , 1-12
Open AccessSurface-modified elastomeric nanofluidic devices for single nanoparticle trapping
Our work focuses on the development of simpler and effective production of nanofluidic devices for high-throughput charged single nanoparticle trapping in an aqueous environment. Single nanoparticle confinement using electrostatic trapping has been an effective approach to study the fundamental properties of charged molecules under a controlled aqueous environment. Conventionally, geometry-induced electrostatic trapping devices are fabricated using SiOx-based substrates and comprise nanochannels imbedded with nanoindentations such as nanopockets, nanoslits and nanogrids. These geometry-induced electrostatic trapping devices can only trap negatively charged particles, and therefore, to trap positively charged particles, modification of the device surface is required. However, the surface modification process of a nanofluidic device is cumbersome and time consuming. Therefore, here, we present a novel approach for the development of surface-modified geometry-induced electrostatic trapping devices that reduces the surface modification time from nearly 5 days to just a few hours. We utilized polydimethylsiloxane for the development of a surface-modified geometry-induced electrostatic trapping device. To demonstrate the device efficiency and success of the surface modification procedure, a comparison study between a PDMS-based geometry-induced electrostatic trapping device and the surface-modified polydimethylsiloxane-based device was performed. The device surface was modified with two layers of polyelectrolytes (1: poly(ethyleneimine) and 2: poly(styrenesulfonate)), which led to an overall negatively charged surface. Our experiments revealed the presence of a homogeneous surface charge density inside the fluidic devices and equivalent trapping strengths for the surface-modified and native polydimethylsiloxane-based geometry-induced electrostatic trapping devices. This work paves the way towards broader use of geometry-induced electrostatic trapping devices in the fields of biosensing, disease diagnosis, molecular analysis, fluid quality control and pathogen detection.
- 20 January 2021
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 38 (2) , 2000275
Optimization of Nanofluidic Devices for Geometry‐Induced Electrostatic Trapping
Nanoparticle trapping in a nanofluidic device utilizing geometry‐induced electrostatic (GIE) potential trap is an efficient and robust way to perform nano‑object confinement and single particle studies. The GIE‑trapping is a passive method that solely depends on the device geometry and device‐particle surface interaction. Therefore, optimization of a nanofluidic device based on experimental requirements, helps to achieve stiffer single‐particle trapping. The efficiency of a GIE‑trapping device is defined in terms of residence time and trapping stiffness of the nanoparticle inside a potential trap. The present study reveals all crucial parameters that affect the device efficiency, particle trapping stiffness, and particle residence time. Furthermore, the trends of particle trapping stiffness are presented as a function of crucial parameters and demonstrate two variants of simulations to estimate the particle trapping efficiency: (a) using charged particle, and (b) using point charge approximation. Simulations with charged particle give more realistic values related to particle trapping whereas simulations with point charge approximation is a faster approach which gives approximate values and a guideline for more rigorous simulations. The results demonstrate a good agreement with experimental observations and hold the key for future developments in this field, wherein a device geometry can be very precisely optimized.
- 20 January 2021
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 38 (2) , 2000275
Optimization of Nanofluidic Devices for Geometry‐Induced Electrostatic Trapping
Nanoparticle trapping in a nanofluidic device utilizing geometry‐induced electrostatic (GIE) potential trap is an efficient and robust way to perform nano‑object confinement and single particle studies. The GIE‑trapping is a passive method that solely depends on the device geometry and device‐particle surface interaction. Therefore, optimization of a nanofluidic device based on experimental requirements, helps to achieve stiffer single‐particle trapping. The efficiency of a GIE‑trapping device is defined in terms of residence time and trapping stiffness of the nanoparticle inside a potential trap. The present study reveals all crucial parameters that affect the device efficiency, particle trapping stiffness, and particle residence time. Furthermore, the trends of particle trapping stiffness are presented as a function of crucial parameters and demonstrate two variants of simulations to estimate the particle trapping efficiency: (a) using charged particle, and (b) using point charge approximation. Simulations with charged particle give more realistic values related to particle trapping whereas simulations with point charge approximation is a faster approach which gives approximate values and a guideline for more rigorous simulations. The results demonstrate a good agreement with experimental observations and hold the key for future developments in this field, wherein a device geometry can be very precisely optimized.
- Top Cited PapersOpen Access
- 22 April 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (4) , e0124126
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Computational modeling and simulations are increasingly being used to complement experimental testing for analysis of safety and efficacy of medical devices. Multiple voxel- and surface-based whole- and partial-body models have been proposed in the literature, typically with spatial resolution in the range of 1–2 mm and with 10–50 different tissue types resolved. We have developed a multimodal imaging-based detailed anatomical model of the human head and neck, named “MIDA”. The model was obtained by integrating three different magnetic resonance imaging (MRI) modalities, the parameters of which were tailored to enhance the signals of specific tissues: i) structural T1- and T2-weighted MRIs; a specific heavily T2-weighted MRI slab with high nerve contrast optimized to enhance the structures of the ear and eye; ii) magnetic resonance angiography (MRA) data to image the vasculature, and iii) diffusion tensor imaging (DTI) to obtain information on anisotropy and fiber orientation. The unique multimodal high-resolution approach allowed resolving 153 structures, including several distinct muscles, bones and skull layers, arteries and veins, nerves, as well as salivary glands. The model offers also a detailed characterization of eyes, ears, and deep brain structures. A special automatic atlas-based segmentation procedure was adopted to include a detailed map of the nuclei of the thalamus and midbrain into the head model. The suitability of the model to simulations involving different numerical methods, discretization approaches, as well as DTI-based tensorial electrical conductivity, was examined in a case-study, in which the electric field was generated by transcranial alternating current stimulation. The voxel- and the surface-based versions of the models are freely available to the scientific community.
- 22 April 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (4) , e0124126
Top Cited PapersOpen AccessMIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Computational modeling and simulations are increasingly being used to complement experimental testing for analysis of safety and efficacy of medical devices. Multiple voxel- and surface-based whole- and partial-body models have been proposed in the literature, typically with spatial resolution in the range of 1–2 mm and with 10–50 different tissue types resolved. We have developed a multimodal imaging-based detailed anatomical model of the human head and neck, named “MIDA”. The model was obtained by integrating three different magnetic resonance imaging (MRI) modalities, the parameters of which were tailored to enhance the signals of specific tissues: i) structural T1- and T2-weighted MRIs; a specific heavily T2-weighted MRI slab with high nerve contrast optimized to enhance the structures of the ear and eye; ii) magnetic resonance angiography (MRA) data to image the vasculature, and iii) diffusion tensor imaging (DTI) to obtain information on anisotropy and fiber orientation. The unique multimodal high-resolution approach allowed resolving 153 structures, including several distinct muscles, bones and skull layers, arteries and veins, nerves, as well as salivary glands. The model offers also a detailed characterization of eyes, ears, and deep brain structures. A special automatic atlas-based segmentation procedure was adopted to include a detailed map of the nuclei of the thalamus and midbrain into the head model. The suitability of the model to simulations involving different numerical methods, discretization approaches, as well as DTI-based tensorial electrical conductivity, was examined in a case-study, in which the electric field was generated by transcranial alternating current stimulation. The voxel- and the surface-based versions of the models are freely available to the scientific community.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Computational platform combining detailed and precise functionalized anatomical phantoms with EM-Neuron interaction modeling
A computational framework including functionalized anatomical phantoms able to simulate electromagnetic (EM)-neuron interactions in complex tissue-structure environments was developed. The anatomic head model distinguishes a large number of structures, particularly in regions relevant to EM-neuron interactions (i.e., ear, eye, deep brain structures). Multimodal Magnetic Resonance (MR) images were acquired together with Diffusion Tensor Imaging (DTI) data to guide neuron model placement and inform about tissue anisotropy. A dedicated EM solver was implemented and coupled with dynamic models of neuronal activity. The topologically conforming, non-self-intersecting, high-element-quality surfaces are suitable for a wide range of numerical methods and solvers, as demonstrated in an application derived from transcranial alternating current stimulation. The platform was validated against literature data, e.g., on the SENN [1] model which was further extended to account for local thermal effects. Additionally, the EM-neuron coupling simulation platform was also applied to investigate MRI gradient coil switching induced nerve stimulation.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Computational platform combining detailed and precise functionalized anatomical phantoms with EM-Neuron interaction modeling
A computational framework including functionalized anatomical phantoms able to simulate electromagnetic (EM)-neuron interactions in complex tissue-structure environments was developed. The anatomic head model distinguishes a large number of structures, particularly in regions relevant to EM-neuron interactions (i.e., ear, eye, deep brain structures). Multimodal Magnetic Resonance (MR) images were acquired together with Diffusion Tensor Imaging (DTI) data to guide neuron model placement and inform about tissue anisotropy. A dedicated EM solver was implemented and coupled with dynamic models of neuronal activity. The topologically conforming, non-self-intersecting, high-element-quality surfaces are suitable for a wide range of numerical methods and solvers, as demonstrated in an application derived from transcranial alternating current stimulation. The platform was validated against literature data, e.g., on the SENN [1] model which was further extended to account for local thermal effects. Additionally, the EM-neuron coupling simulation platform was also applied to investigate MRI gradient coil switching induced nerve stimulation.
- 1 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21643342,p. 1483-1487
Modeling, effect prediction, and planning for EM-and FUS-based thermal treatment
Thermal therapies are valuable modalities in numerous fields, including cancer treatment, surgery, targeted drug delivery and more. However, numerical modeling is typically required to enable such treatments or to improve their quality. This paper presents the underlying requirements of numerical modeling and an implementation framework, discusses the limitations of current solutions, and identifies various areas warranting further research. Particular emphasis is placed on the need to identify the principal factors influencing treatment effectiveness and dose concepts more closely related to treatment outcome. Progress in these areas will allow for more reliable outcome predictions and decision-making, as well as effectiveness-oriented treatment optimization.
- 1 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21643342,p. 1483-1487
Modeling, effect prediction, and planning for EM-and FUS-based thermal treatment
Thermal therapies are valuable modalities in numerous fields, including cancer treatment, surgery, targeted drug delivery and more. However, numerical modeling is typically required to enable such treatments or to improve their quality. This paper presents the underlying requirements of numerical modeling and an implementation framework, discusses the limitations of current solutions, and identifies various areas warranting further research. Particular emphasis is placed on the need to identify the principal factors influencing treatment effectiveness and dose concepts more closely related to treatment outcome. Progress in these areas will allow for more reliable outcome predictions and decision-making, as well as effectiveness-oriented treatment optimization.
- Top Cited Papers
- 26 November 2012
- Published by AIP Publishing in Applied Physics Letters
- Vol. 101 (22) , 221101
Ultra-thin perfect absorber employing a tunable phase change material
We show that perfect absorption can be achieved in a system comprising a single lossy dielectric layer of thickness much smaller than the incident wavelength on an opaque substrate by utilizing the nontrivial phase shifts at interfaces between lossy media. This design is implemented with an ultra-thin (∼λ/65) vanadium dioxide (VO2) layer on sapphire, temperature tuned in the vicinity of the VO2 insulator-to-metal phase transition, leading to 99.75% absorption at λ = 11.6 μm. The structural simplicity and large tuning range (from ∼80% to 0.25% in reflectivity) are promising for thermal emitters, modulators, and bolometers.
- 26 November 2012
- Published by AIP Publishing in Applied Physics Letters
- Vol. 101 (22) , 221101
Top Cited PapersUltra-thin perfect absorber employing a tunable phase change material
We show that perfect absorption can be achieved in a system comprising a single lossy dielectric layer of thickness much smaller than the incident wavelength on an opaque substrate by utilizing the nontrivial phase shifts at interfaces between lossy media. This design is implemented with an ultra-thin (∼λ/65) vanadium dioxide (VO2) layer on sapphire, temperature tuned in the vicinity of the VO2 insulator-to-metal phase transition, leading to 99.75% absorption at λ = 11.6 μm. The structural simplicity and large tuning range (from ∼80% to 0.25% in reflectivity) are promising for thermal emitters, modulators, and bolometers.
- 24 September 2008
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 129 (12) , 121101
Veering the motion of a magnetic chemical locomotive in a liquid
The motion of micron-sized catalytic polymer beads coated with thin film or nanoparticle form of Ni in aqueous H2O2 is reported herein. In the absence of any magnetic field, the beads moved vertically upward in the medium, owing to sufficient bubbles deposited on them following catalytic decomposition of H2O2 by Ni. However, in the presence of an external magnetic field (perpendicular to the direction of motion), angular deviation in the motion is observed, with the deviations increasing with the strength of the field. The results are explained based on a model involving interaction of the beads with the external magnetic field.
- 24 September 2008
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 129 (12) , 121101
Veering the motion of a magnetic chemical locomotive in a liquid
The motion of micron-sized catalytic polymer beads coated with thin film or nanoparticle form of Ni in aqueous H2O2 is reported herein. In the absence of any magnetic field, the beads moved vertically upward in the medium, owing to sufficient bubbles deposited on them following catalytic decomposition of H2O2 by Ni. However, in the presence of an external magnetic field (perpendicular to the direction of motion), angular deviation in the motion is observed, with the deviations increasing with the strength of the field. The results are explained based on a model involving interaction of the beads with the external magnetic field.